Download Peak brochure 2013 LowRes - Cp

Transcript
CP-ANALYTICA Your Chromatography Provider
www.cp-analytica.at
Gas Generatoren
Wasserstoff, Stickstoff, Luft
Wir liefern die besten Gas Generatoren für Ihre Anwendungen
und sorgen mit perfektem Service für den reibungslosen
Betrieb in Ihrem Labor.
Peak Scientific Gas Generators
CP-ANALYTICA GmbH tel +43 (0)2572/4381 | fax +43 (0)2572/20791 | [email protected] | www.cp-analytica.at
Introducing Peak
All it takes is experience, passion and a dynamic environment
to produce the best gas generators in the world!
We have been around long enough to see all the
changes in the world of laboratory gas. Our expert
knowledge and willingness to continually improve
has allowed us to grow into a global company.
Our product development is based on matching
specific needs. That’s why Peak works hand in hand
with instrument manufacturers to ensure superb
technical performance.
‘Service & Support’ is not just a phrase we use; it’s
a deep rooted belief! To us the relationship with
our customer starts long before our service
engineers come to visit.
Smoother, quieter and more efficient than anything
else on the market; our laboratory gas generators are
well established and will stand the test of time.
Peak Scientific. Go with the flow.
Genius Range
The NM32LA Nitrogen Gas Generator is the building block
of our Genius Products.
Its ingenious design has been proven to be smoother, quieter,
safer and more efficient than anything else on the market today.
“ ...We have nothing
to declare but our
Genius.”
Extensive testing of the generator by Mass Spec Manufacturers
throughout the development process has guaranteed the best
solution for your LC/MS. Through continuous cooperation with
instrument manufacturers, we have been able to design a range
of Genius Products suitable for your specific application.
Nitrogen
32 L/min @ 6.9 bar / 1.13 CFM @ 100 psi
Min/ Max Operating Temperature
5ºC - 35ºC / 41ºF - 95ºF
Max Relative Humidity
80% Non-Condensing
Max Altitude
2000 Metres
Particles
< 0.01µm
Gas Outlets
1x 1/4” BSP Female
Phthalates
None
Suspended Liquids
None
Noise Level
54 dB(A) @ 1m
Electrical Requirements
230v 50/60Hz 7.0A
Power Consumption
1610 Watts
Dimensions (cm/ ins) WxDxH
60 x 75 x 71.2 / 23.6 x 29.5 x 28
Weight (kg/ lbs)
95 / 209
Pictured: Genius 3010 & NM32LA
Features & Benefits:
Model
Gas Outlet
Genius NM32LA
32 L/min N2
Nitrogen generator suitable for most LC/MS instruments including Agilent, Bruker, Perkin Elmer,
Shimadzu, Thermo Scientific, Waters and many more.
Genius N118LA
18 L/min N2
Nitrogen Generator developed for Thermo / Dionex MSQ+
Genius ABN2ZA
12L/min N2
24 L/min Dry Air
8 L/min Dry Air
For use with the AB SCIEX range of LC/MS instruments, up to and including the latest AB5600.
Genius AB3G
12L/min N2
24 L/min Dry Air
8 L/min Dry Air
For use with the AB SCIEX Range of LC/MS instruments, up to and including the latest AB5600.
Premium model including fail safe compressor technology to ensure maximum up time.
Genius NM3G
30 L/min N2
For use with any LC/MS instrument. Premium model including fail safe compressor technology to ensure
maximum up time. Recommended for clinical application where maintaining gas flow is imperative.
Genius 1022
30 L/min N2
Nitrogen generator with pressure requirements of 116psi specifically designed for the
Thermo Q Exactive LC/MS.
Space Saving Design
Maximum use of valuable laboratory floor space
Genius 1023
32 L/min N2
Nitrogen Generator switchable between standard LC/MS grade Nitrogen and the 10% Oxygen rich Nitrogen
required for Agilent Chip Cube.
Outstanding Service Capabilities
Genius 1050
32 L/min N2
Nitrogen generator utilising CMS technology.
Genius 1052
32 L/min N2
Nitrogen generator for LECO modulators.
Genius 3010
64 L/min N2
Nitrogen generator developed for Agilent iFunnel Technology LC/MS 6490 & LC/MS 6550.
Minimum Service Requirements
Only one annual service required
Genius 3013
64 L/min N2
Nitrogen Generator developed for Agilent iFunnel Technology LC/MS 6490 & LC/MS 6550, switchable
between standard LC/MS grade Nitrogen and the 10% Oxygenrich Nitrogen required for Agilent Chip Cube.
Simple Installation
Generator designed as a plug and
play system
Genius 3020
2 x 32 L/min N2
Nitrogen generator developed to supply two LC/MS systems, with independent control.
Genius 3022
2 x 32 L/min N2
Nitrogen generator developed to supply two Thermo Q Exactive LC/MS, with independent control.
Genius 3023
2 x 32 L/min N2
Nitrogen generator developed to supply two Agilent LC/MS, with independent control, switchable between
standard LC/MS grade Nitrogen and the 10% Oxygen rich Nitrogen required for Agilent Chip Cube.
Genius 3030
2 x 12L/min N2
2 x 24 L/min Dry Air
2 x 8 L/min Dry Air
Genius 3031
16 L/min N2
25 L/min Dry Air
24 L/min Dry Air
Genius 3040
1 x 12 L/min N2
1 x 32 L/min N2
24 L/min Dry Air
2 x 8 L/min Dry Air
Genius 3045
32 L/min N2
50 L/min Dry Air
Convenience
Gas on demand
Easy to move
Features
No need to wait for cylinder delivery
Mass Spec manufacturer approved
Rigorously tested by manufacturers to ensure
purity requirements are met
Complimented on outstanding reliability
Low Noise & Vibration
Separate insulated compressor
compartment
Anti vibration compressor mounts
We aim to provide an instant response by
telephone or email
Engineer on-site expected between 48h-72h for
contract customers
95% first time fix rate
Nitrogen generator developed to supply two AB SCIEX LC/MS instruments, with independent control.
Nitrogen generator designed to supply AB SCIEX 6500 or other AB SCIEX LC/MS with high flow requirement.
Designed to supply one AB SCIEX LC/MS system, up to and including the 5600. In addition the generator
includes a separate 32L/min of LC/MS grade Nitrogen available for a second LC/MS instrument.
The Genius 3045 Nitrogen Generator is specifically designed for use with the Bruker EVOQ Triple Quad. This
generator will supply a single application and provide Nitrogen gas as well as a separate Dry Air output.
4
2
Infinity Range
The Infinity series delivers performance and value far beyond
expectations. Offering a pure and reliable source of gas,
these perpetual flow Nitrogen generators are suitable for
a variety of applications in your laboratory.
Expertly designed by Peak Scientific’s knowledgeable
Engineering team, the Infinity 50 series will offer a single
generator solution for up to 16 LC/MS instruments whereas the
Infinity 90 series offers a single generator solution for one or
multiple Nitrogen evaporators.
“ One Peak Infinity generator
will supply multiple applications
and remove the need for costly
cylinders and reduce your
carbon footprint enormously.”
Pictured: Infinity 1031 & Infinity 5010
Features & Benefits:
Model
Gas Output
Application
Infinity 1031
1 x 18 L/min N2
1 x 26 L/min Dry Air
1 x 25 L/min Dry Air
1 x AB Sciex - Full Range
Single Source Solution
One generator can cater for the requirements of
multiple applications and multiple laboratories
on site
Infinity 1032
1 x 36 L/min N2
1 x 52 L/min Dry Air
1 x 50 L/min Dry Air
2 x AB Sciex - Full Range
Infinity 1033
1 x 54 L/min N2
1 x 78 L/min Dry Air
1 x 75 L/min Dry Air
4 x AB Sciex - Full Range
Quiet
Completely silent in operation
Infinity 1034
1 x 72 L/min N2
1 x 104 L/min Dry Air
1 x 100 L/min Dry Air
6 x AB Sciex - Full Range
Infinity NM18L
18 L/min N2
LC/MS
Infinity NM32L
32 L/min N2
LC/MS
Infinity 5010
60 L/min N2
LC/MS
Simple Installation
Commission Peak Scientific’s expert installation
engineers, let us do the work for you
Infinity 5020
120 L/min N2
LC/MS
Infinity 5030
180 L/min N2
LC/MS
Economical
More cost effective than any other gas
supply method
Infinity 5040
240 L/min N2
LC/MS
Infinity 5050
300 L/min N2
LC/MS
Convenient
Gas on demand, no health hazards, no need to
worry about running out of gas
Infinity 5060
360 L/min N2
LC/MS
Infinity 5070
420 L/min N2
LC/MS
Infinity 5080
480 L/min N2
LC/MS
Infinity 9010
140 L/min N2
Turbovap
Infinity 9020
280 L/min N2
Turbovap
Infinity 9030
420 L/min N2
Turbovap
Infinity 9040
560 L/min N2
Turbovap
Infinity 9050
700 L/min N2
Turbovap
Infinity 9060
840 L/min N2
Turbovap
Infinity 9070
980 L/min N2
Turbovap
Infinity 9080
1120 L/min N2
Turbovap
Durable
Few moving parts with minimum maintenance
requirements
Mobile
Flexibility to position generator where required,
the generator is supplied with caster wheels for
easy mobility
Eco- Friendly
Onsite gas generation considerably reduces your
carbon footprint
Experience
Preferred choice supplier of many instruments
manufacturers
Outstanding Service Capabilities
We aim to provide an instant response by
telephone or email
Engineer on-site expected between 48h-72h
for contract customers
95% first time fix rate
6
Hydrogen Generators
“ Peak Scientific has a presence
on every continent and
we export to 126 countries
worldwide.”
Our Hydrogen generators have been specifically designed
to cater for the requirements of any GC user. The PH Range
offers a robust and reliable solution for FID.
The Precision 500 has been developed to offer ultra high
purity hydrogen for your GC carrier gas requirements.
Hydrogen Generator PH Range
Technical Specifications
PH 200
PH 300
PH 600
Hydrogen
200 cc/min
300 cc/min
600 cc/min
Purity
99.9995%
99.9995%
99.9995%
Hydrogen Generator Precision 500
Technical Specifications
Precision 500
Hydrogen
500 cc/min
Purity
99.9999%
Moisture
<1ppm
Pictured: PH Range & Precision 500
Features & Benefits:
Improved Analysis Results
Hydrogen as a carrier gas allows lower
detection limits
Cost
Hydrogen is a less expensive alternative
to Helium
Efficiency
Allows up to 35% faster analysis
Safety
No pressurised Hydrogen storage and
automatic shutdown safety features
Hydrogen Detector
Optional detector to monitor Hydrogen and
ensure no gas build up inside a GC oven
Purity
99.9995% for PH and 99.9999% for
Precision 500
About Helium and Hydrogen…
Are we running out of Helium? No, not quite.
However, there is a shortage causing supply
issues and a significant increase in cost.
Many leading GC Manufacturers understand
the impact on your laboratory and have started
to actively recommend switching your carrier
gas from Helium to Hydrogen.
There are major benefits of using Hydrogen
as your carrier gas:
• Increased speed: increasing the linear flow rate
allows for shorter run times, thereby increasing
the throughput of your laboratory
• Lower temperature separations: at the faster
elution times, it may not be necessary to increase
the column temperature run rate. It may even
be possible to lower the maximum temperature
needed for the analysis
• Longer column life: lower temperatures lead
to less column bleed, which in turn can mean
a longer column life. In addition, hydrogen is
a reducing gas and can remove potential acidic
sites off the column, further increasing column life!
What about safety?
Hydrogen gas is already being used commonly in the
laboratory for a variety of purposes. It is the fuel used
on the most commonly used detectors (FID) and
therefore already present in most GC Labs.
Nevertheless we understand any concerns you may
have and have therefore incorporated numerous
safety features in our Hydrogen Generators’ design:
• No storage of hydrogen
• Automatic shut down on leak detection
• Mechanical shut down fail safe
• Hydrogen generation on demand
For extra peace of mind, Peak Scientific have further
developed a Hydrogen Detector, which can be
connected to your GC, measuring the Hydrogen
content within the GC oven and alerting you should
there be a critical build up.
• Availability: Hydrogen is readily available through
the electrolysis of water and with a Peak Gas
Generator can be generated on demand
• Environmental concerns: because of its availability,
Hydrogen is widely regarded as a green gas
N2
1.00
He
0.75
H
0.50
H2
0.25
10
20
30
40
50
60
u (cm/sec)
8
2
PSA Nitrogen Generators
Pressure Swing Adsorption (PSA) has been employed for
decades and is the preferred choice for generating Ultra
High Purity Nitrogen at low flow rates.
The technology is self- regenerating, offering you a reliable
and durable source of Ultra High Purity Nitrogen with little
need for attention.
Peak Scientific also produces a range of combi-systems,
which supply you with a source of dry, clean Air, as well
as UHP Nitrogen.
In addition, we can make our systems available with
or without an internal air compressor.
“ We are proud to support
advances in science with
over 10,000 of our products
in your laboratories.”
Pictured: PSA Nitrogen
Features & Benefits:
They just work, and work, and work, and work ...
Regenerative PSA Technology makes this
possible: the purity of nitrogen generators
is always as stated and does not decrease
over time - not to mention Peak’s long record
of reliability.
Purity
Although PSA generated Nitrogen may still
contain traces of argon, the output purity
exceeds UHP cylinder gas specifications - and it
is more cost effective as well!
Single Source Solution
One generator can cater for the requirements of
multiple applications.
High Purity Nitrogen Generators NG Range
NG250(A)
NG600(A)
NG1000(A)
NG2000(A)
NG3000(A)
NG4000(A)
NG5000(A)
UHP Nitrogen
250 cc/min
600 cc/min
1,000 cc/min
2,000 cc/min
3,000 cc/min
4,000 cc/min
5,000 cc/min
Nitrogen Purity*
99.9995%
99.9995%
99.9995%
99.9995%
99.9995%
99.9995%
99.9995%
80psi / 0.5 bar
80psi / 0.5 bar
80psi / 0.5 bar
80psi / 0.5 bar
80psi / 0.5 bar
80psi / 0.5 bar
80psi / 0.5 bar
Pressure**
High Purity Nitrogen Generators
and Dry Air Combi-Systems ANG Range
Simple but Effective
They are easy to install, easy to maintain, easy
to use and easy on the eye as they are small
enough to be placed anywhere in your lab.
A Real Cost Saver
No more reordering, storing and changing
of cylinder gas- saving you money all along
the way.
Support
Our world class after sales service comes
as standard.
ANG250(A)
ANG600(A)
ANG1000(A)
ANG2000(A)
250 cc/min
600 cc/min
1,000 cc/min
3,000 cc/min
1,200 cc/min
1,500 cc/min
1,500 cc/min
3,000 cc/min
99.9995%
99.9995%
99.9995%
99.9995%
80psi / 0.5 bar
80psi / 0.5 bar
80psi / 0.5 bar
80psi / 0.5 bar
UHP Nitrogen
Dry Air
Nitrogen Purity*
Pressure**
*Nitrogen content is devoid of Oxygen.
**Compressor based systems only.
10
Fusion 1010
Peak’s Fusion 1010 ingeniously provides two high purity
gases from one system and has a unique ‘rapid restart’
control allowing it to be operational again after any power
cut in a fraction of the time normally required. A huge benefit
in areas where power supply is erratic, Fusion 1010 delivers
reliable high performance in the laboratory. Designed
specifically for use with GC- ECD and GC- FID. It may also
be used with THA applications.
Zero Nitrogen
0.6 L/min @ 7.6 bar - 0.021 CFM @ 80 psi
Zero Nitrogen Purity (O2 content)
99.9995%
Zero Nitrogen Hydrocarbon Content
(as Methane)
< 0.1ppm
Zero Air
1.5 L/min @ 60 psi - 0.052 CFM @ 4.14 bar
Zero Air Hydrocarbon Content (as Methane)
< 0.1ppm
Internal Air Compressor
Yes
“Peak exclusively source robust,
high performance parts to
ensure our generators are
safe, reliable and meet your
performance needs in the lab.”
Pictured: Fusion 1010
Features & Benefits:
Zero Nitrogen & Zero Air
Catalyst chamber ensures removal
of Hydrocarbons to < 0.1ppm
Unique Design
Only gas generator to supply Zero Nitrogen
and Zero Air from two separate outlets
whilst the internal air compressor ensures
independence from external air sources
Optimum Analysis
Zero Nitrogen and Zero Air for improved
stability and greater reproduction of results
with guaranteed purity
Rapid Restart
Fusion 1010 has been designed to allow for
almost immediate supply of Zero Nitrogen and
Zero Air after power- cuts of up to 20 minutes
Quiet in Operation
Not audible in normal working lab environment
Mobile
Flexibility to position generator where
required, even under standard lab bench,
our generators are supplied with caster
wheels for easy mobility
Support
Our world class after sales service comes
as standard
Ryan Scott (Peak Technician)
12
Zero Air Generators
The catalyst chambers inside our Zero Air Generators make
sure compressed air is stripped of all hydrocarbons before
it is fed into your application.
Available in different shapes and sizes, dependent or
independent from external air supplies, Peak Zero Air
Generators can fulfill all of your requirements.
Of course, minimal maintenance and a long, trouble-free
Generator life come as a Peak standard.
“At Peak, we work as a team
to help ensure the best
solution for our customers.
The robust designs, simple
installation and minimal
maintenance mean we can
offer you long-term value
for money.”
Pictured: ZA015 & ZA300
Features & Benefits:
Complete Convenience
No more changing cylinders! Save not only
the time and money, but also the need to
recalibrate your instrument.
So much more than an Air Purifier
Our zero air generators produce air with a
total hydrocarbon concentration of less than
0.1 ppm.
Plug & Play
The generator is very easy to install and
does what you want it to do - with minimum
maintenance requirements.
Compact
Most of our zero air generators are very
compact in size and nicely fit anywhere in your
laboratory. Others are so small and light they
can be attached to the lab wall, not taking any
laboratory space.
ZA015
ZA035(A)
ZA070(A)
ZA180(A)
ZA300
FID, FPD, ECD, THA
GC, TGA, TMA, TOD
GC, TGA, TMA
GC, TGA, TMA, TOD
GC, TGA, TMA, TOD
1,500 cc/min
3,500 cc/min
7,000 cc/min
18,000 cc/min
30,000 cc/min
Outlet CH4 Concentration
< 0.1 ppm
< 0.1 ppm
< 0.1 ppm
< 0.1 ppm
< 0.1 ppm
Max Inlet CH4 Concentration
100 ppm
100 ppm
100 ppm
100 ppm
100 ppm
Particles
< 0.01 µm
< 0.01 µm
< 0.01 µm
< 0.01 µm
< 0.01 µm
- units without internal compressor
125 psi / 8.6 bar
125 psi / 8.6 bar
125 psi / 8.6 bar
125 psi / 8.6 bar
125 psi / 8.6 bar
- units with internal compressor
80 psi / 5.5 bar
80 psi / 5.5 bar
80 psi / 5.5 bar
80 psi / 5.5 bar
80 psi / 5.5 bar
Application
Zero Air
Max Outlet Pressure
Support
Our world class after sales service comes
as standard.
14
Our other Gas Generators
Over the years Peak Scientific has developed a wide range
of air purifiers which cater for the requirements of various
applications, such as FT-IR, TOC and CO2 Analyzers.
Most of these products offer gas free of organic contaminants,
such as Carbon Oxides and Hydrocarbons making them ideal
for environmental analysis.
We also manufacture a range of basic air dryers that can
be used to prevent moisture contamination through in house
air or other air sources.
“All of our generators
offer superb technical
performance in the lab
and, of course our world
class after sales service
comes as standard!”
Pictured: STOCA & TOC1500
Features & Benefits:
TOC1500
TOC1500HP
SCTOCA
1,500 cc/min
1,500 cc/min
500 cc/min
CH4 Content as methane
<2.0 ppm
<0.1 ppm
<0.1 ppm
CO2 Content
<1.0 ppm
<1.0 ppm
<1.0 ppm
CO Content
n/a
n/a
<1.0 ppm
SOX Content
n/a
n/a
<1.0 ppm
Input dependant
Input dependant
80 psi / 5.5 bar
PG14L
PG28L
PG85L
Purge Gas
14 L/min
28 L/min
85 L/min
CO2 Content
< 1.0ppm
< 1.0ppm
< 1.0ppm
100psi / 6.9 bar
100psi / 6.9 bar
100psi / 6.9 bar
TOC
Reliability
Sturdy design ensures maximum uptime
of your application
TOC
Purity
Clean, dry carbon dioxide and hydrocarbon
free air
Mobile
Flexibility to position generator where required
Max Outlet Pressure
Simple Installation
Designed as plug & play system
Economical
More cost effective than any other gas
supply method
Purge Gas
Convenient
Gas on demand, no health hazards, no need to
worry about running out of gas
Max Outlet Pressure
Calibration
Gas
CG15L
CG22L
Calibration Gas
15 L/min
22 L/min
CO2
1.0ppm
1.0ppm
CO
1.0ppm
1.0ppm
THC
0.1ppm
0.1ppm
AD70L
AD140L
AD302L
AD1010L
Air Dryer
70 L/min
140 L/min
302 L/min
1010 L/min
Dewpoint
- 70*c/- 94*f
- 70*c/- 94*f
- 70*c/- 94*f
- 70*c/- 94*f
Air Dryers
16
Accessorize with Peak
Gas generators are very straight forward and need very little
in the way of accessories. There are just a couple of things you
may want to consider for your laboratory:
Hydrogen Detector
“ We test all Peak gas generators
under strict conditions to ensure
you receive the highest quality
as well as value for money.”
Hydrogen is a combustible gas and we understand the safety
concerns associated. To offer that extra peace of mind we
developed a Hydrogen Detector, which can be wall mounted
above your GC and can detect a potentially dangerous build-up
of Hydrogen inside the GC Oven.
Hydrogen Interconnection Cable
If you would like multiple Precision 500 Generators to work
together to offer a source of hydrogen to meet your lab
requirements you will require this Interconnection Cable. One
cable is required for every pair of Precision 500 Generators to
work in series mode.
Boost Transformers
If your power supply does not quite offer the voltage required
by our gas generators, you can use these Peak approved Boost
Transformers to ensure the technical requirements are met.
Service Kits
Our service kits are not really accessories for our generators,
but a vital part in maintaining the system’s performance.
We recommend for every Peak Generator user, who has not
opted in to one of our service plan options, to purchase these
Service Kits on an annual basis. Your User Manual should
highlight the appropriate service kit for your generator,
but please feel free to contact our service team for advice.
Pictured: Precision 500 + Hydrogen Detector Centre