Download Loop-IP6810 Self-Healing Ring Network Termination Unit
Transcript
Loop-IP6810 Self-Healing Ring Network Termination Unit Description Features y y y y y y y y y y y y y y y y y y Full front access (ETSI) unit comply with IP30 standard Desktop, wall, or DIN Rail mounting Compact intelligent FX packet optical ring with layer-2 switch capability WAN port with OA&M function y Dual optical Fast Ethernet interfaces or y Dual SFP optical housing interfaces Tributary ports y 3 ports 10/100 BaseT Ethernet (with PoE option available in DC 48 only) y 2 ports RS232/485 Interfaces, user selectable via 2-port DIP switch y 2 Dry-Contact for input and 2 Dry-Contact for output; support point-to-point and point to multi-point Power modules y On-board fixed single AC supply y On-board fixed single/dual DC modules with dual feed Auto-discovery topology, auto-diagnostic and remote-configure for easy plug-and-install (up to 64 units) Ethernet Function: y LEAPS y IEEE 802.1w RSTP, 802.1s MSTP* y IEEE 802.3x Flow Control, 802.1q Port Base VLAN/ Port Isolation Up to 1024 MAC address High speed, asynchronous RS232/RS485 for point-to-point, point to multi-point, or Omni-bus-like applications Master/Slave units setting by using DIP switch Auto-negotiating or forced speed for speed and Full/Half Duplex for Ethernet ports Full/Half Duplex for tributary Ethernet ports Alarm Relay and ACO (Alarm Cutoff) button Remote firmware download via TFTP & Z modem Remote configuration upload & download via TFTP Management port and interface y In-band management y RS232 console via DB9 connector y SNMP v1, v2, v3 y SSH v2 y Telnet y LoopView GUI EMS RoHS Compliance The Loop-IP6810 is a self-healing ring network termination unit (NTU) with a built-in L2 switch. It can be desktop, wall or DIN Rail mounted. LEAPS, RSTP, or MSTP* Ethernet Ring protection or point-to-point protection is facilitated in 100 Base-FX. All end equipments can be either in packet format via Ethernet ports or serial data via RS232/485 interfaces which will be converted into packet format within IP6810. The IP6810 has two WAN optical interfaces, two RS232/485 DTE interfaces, three Ethernet LAN interfaces, two sets of dry contact IN/OUT interfaces, and one alarm relay connector. TheIP6810 has a hardening option which will support –20°C to 70°C. The IP6810 supports auto-discovery to discover all units on the ring, and also supports remote-configure for the ease of installations. The IP6810 supports single AC, single DC or dual DC to field requirement. PoE option is also available. The IP6810 facilitates automation systems, SCADA systems, surveillance systems, traffic control systems, transportation systems and IP networking with robust protection in ring, point-to-point, or Omni-bus-like topology. Easy installation and configuration also make maintenance or further expansion more efficient and cost-effective. * Future Option *Future Option 1 Ordering Information To specify options, choose from the list below. Note: RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code. Model Main Unit Loop-IP6810-CS-SFPC -ipp1-ipp2-add1 -G Description Note Self-healing NTU Device with dual SFP(mini-GBIC) optical housing daughter card for WAN port (SFP optical module not included). Temperature range 0°C to 50°C (Available in Phase 2) Loop-IP6810-IS-SFPC -ipp1-ipp2-add1 -G Self-healing NTU Device with dual SFP(mini-GBIC) optical housing daughter card for WAN port (SFP optical module not included). Temperature hardening optional rage –20°C to 70°C –Where wan1, wan2, pp1, pp2, ipp1, ipp2,add1, and SFP modules are defined in the tables below. – –Add1 only available on DC48 option. Accessories Software Loop-IP6810-UPGRLEAPS Power Cord Loop-ACC-PC-USA Loop-ACC-PC-EU Loop-ACC-PC-UK Loop-ACC-PC-AUS Loop-ACC-PC-CH Tray 81.TRAY19.0000G User’s Manual Loop-IP6810-S-UM Activation code for LEAPS function AC power cord for Taiwan/America AC power cord for Europe AC power cord for UK AC power cord for Australia AC power cord for China 19” Tray (One tray for two base units) User’s Manual (optional, paper copy). A CD version of the manual is already included as standard equipment. SFP Optical Module (temperature range from 0°C to 50°C) Tables for Fast Ethernet (Available in Phase 2) Multi mode optical module with dual uni-directional fiber, MHBTW 155M, 1310nm, 2Km, LC connector w/o DDM, Fast Ethernet and compliant with ITU G.957 Single mode optical module with dual uni-directional fiber, PHB2W 155M, 1310nm, 15~20Km, LC connector w/o DDM, S-1.1/IR1 Single mode optical module with dual uni-directional fiber, PHB3W 155M, 1310nm, 30Km, LC connector w/o DDM, S-1.1/IR1/Fast Ethernet Single mode optical module with dual uni-directional fiber, PHB5W 155M, 1310nm, 50Km, LC connector w/o DDM, L-1.1/LR1/Fast Ethernet Single mode optical module with dual uni-directional fiber, PHC8W 155M, 1550nm, 80Km, LC connector w/o DDM, L-1.2/LR2 Single mode optical module with dual uni-directional fiber, z Temperature ranges from 0°C to PHCUW 155M, 1550nm, 100Km, LC connector w/o DDM, SFP 50°C L-1.2/LR2Fast Ethernet 155 Mbps z Use 2 fibers for all SFP optical Single mode optical module with dual uni-directional fiber, (mini GBIC) modules. PHCXW 155M, 1550nm, 120Km, LC connector w/o DDM, L-1.2 Dual Fiber extended distance Single mode optical module with dual uni-directional fiber, PHB3D 155M, 1310nm, 30Km, LC connector with DDM, S-1.1/IR1/Fast Ethernet Single mode optical module with dual uni-directional fiber, PHB5D 155M, 1310nm, 50Km, LC connector with DDM, L-1.1/LR1/Fast Ethernet Single mode optical module with dual uni-directional fiber, PHC8D 155M, 1550nm, 80Km, LC connector with DDM, L-1.2/LR2 Single mode optical module with dual uni-directional fiber, PHCUD 155M, 1550nm, 100Km, LC connector with DDM, L-1.2/LR2/Fast Ethernet Single mode optical module with dual uni-directional fiber, PHCXD 155M, 1550nm, 120Km, LC connector with DDM, L-1.2 extended distance 2 SFP Optical Module (temperature range from -40°C to 85°C) Plug-in Tables for Fast Ethernet MHTTW Multi mode optical module with dual uni-directional fiber, 155Mbps, 1310nm, 2Km, LC connector w/o DDM, Fast y Temperature ranges from Ethernet and compliant with ITU G.957 SFP -40°C to 85°C PHT3W Single mode optical module with dual uni-directional fiber, 155 Mbps 155Mbps, 1310nm, 30Km, LC connector w/o DDM, y (mini GBIC) S-1.1/IR1 y Use 2 fibers for all SFP optical Dual Fiber modules PHT6W Single mode optical module with dual uni-directional fiber, 155Mbps, 1310nm, 60Km, LC connector w/o DDM, L-1.1/LR1 NOTE: For other special optical modules, please contact your nearest Loop sales representative. st Where ipp1 is used to select the 1 industrial power supply (temperature hardening optional rage –20°C to 70°C): ipp1 = Description Note y Please choose appropriate power cord Single AC power supply IAC for AC version. (100 to 240 Vac, 50/60 Hz) y It would not support power redundancy. y For redundancy purposes, ordering a Single DC power supply IDC24 second power module will provide dual (-24 Vdc: -18 to -36 Vdc) DC power. Single DC power supply IDC48 (-48 Vdc: -36 to -72 Vdc) nd Where ipp2 is used to select the 2 DC power supply for pp1 (temperature hardening optional rage –20°C to 70°C) : ipp2 = Description Note It is applicable to IDC24 in ipp1 only. Single DC power supply IDC24 (-24 Vdc: -18 to -36 Vdc) It is applicable to IDC48 in ipp1 only. Single DC power supply IDC48 (-48 Vdc: -36 to -72 Vdc) NOTE: Your selection for pp2 must be the same as pp1. Where add1 is used to select enclosure types: Add1 = Description PoE Note Only available on DC48 option only Power over Ethernet 3 Examples 1: Main unit: Loop-IP6810-IS-SFPC-IDC24-IDC24-G Description: Industrial standard unit with 2 SFP optical housing daughter card, two -24 Vdc industrial power modules. Examples 2: Main unit: Loop-IP6810-CS-SFPC-IAC-G (Phase 2) Description: Commercial standard unit with 2 SFP optical housing daughter card, one 100 to 240 Vac industrial power module. Examples 3: Main unit: Loop-IP6810-IS-SFPC-IDC48-IDC48-PoE-G Description: Industrial standard unit with 2 SFP optical housing daughter card, two-48 Vdc industrial power modules, and PoE option. Loop-IP6810 RTU Ethernet Ring -Standalone Product Specification WAN-Network Side Interface Number of Ports Up to 2 Aggregate Lines - SFP Optical Module Characteristics(Commercial Standard, 155Mbps Max. Available in Phase 2) SFP Optical Direction Wavelength (nm) Connector Distance (km) Module MHBTW Dual uni-directional fiber 1310nm LC ( without DDM) 2 PHB2W Dual uni-directional fiber 1310nm LC ( without DDM) 15~20 PHB3W Dual uni-directional fiber 1310nm LC ( without DDM) 30 PHB5W Dual uni-directional fiber 1310nm LC ( without DDM) 50 PHC8W Dual uni-directional fiber 1550nm LC ( without DDM) 80 PHCUW Dual uni-directional fiber 1550nm LC ( without DDM) 100 PHCXW Dual uni-directional fiber 1550nm LC ( without DDM) 120 PHB3D Dual uni-directional fiber 1310nm LC ( with DDM) 30 PHB5D Dual uni-directional fiber 1310nm LC ( with DDM) 50 PHB8D Dual uni-directional fiber 1550nm LC ( with DDM) 80 PHCUD Dual uni-directional fiber 1550nm LC ( with DDM) 100 PHCXD Dual uni-directional fiber 1550nm LC ( with DDM) 120 Note: For industrial standard please contact your nearest Loop sales representative. Aggregate Lines - SFP Optical Module Characteristics(Industrial Standard, 155Mbps Max.) SFP Optical Direction Wavelength (nm) Connector Module MHTTW Dual uni-directional fiber (multi mode) 1310nm LC ( without DDM) PHT3W Dual uni-directional fiber 1310nm LC ( without DDM) PHT6W Dual uni-directional fiber 1310nm LC ( without DDM) Note: For industrial standard please contact your nearest Loop sales representative. Distance (km) 2 30 60 Tributary- Customer Side Interface RS232 Interface Number of Ports Electrical Baud Rate Function Connector RS485 Interface Number of Ports Electrical Baud Rate Function Connector Up to 2 Note: Interface changed by DIP switch from RS485 RS232, DCE 200, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps, asynchronous Up to 16 remote IP address each port Flow control: RTS/CTS, XON/XOFF RTS forwarding DB9, female Up to 2 Note: Interface changed by DIP switch from RS232 RS485, DCE 200, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps, asynchronous DB9, female 4 Ethernet Interface Number of ports Ethernet functions QoS Functions 3 100 Base-FX 10/100BaseT, IEEE 802.3, 802.3u LEAPS (Loop Ethernet Automatic Protection Switching 802.1q Port Base VLAN, Port Isolation 802.3x Flow Control Auto-negotiation (10/100M) Auto MDI/MDIX Full or half duplex Up to 1024 MAC addresses Rate limiting for LAN port Four priority queue Connector RJ45 Dry Contact I/O Interface Connector 2-channel Inputs Internal Resistance Activation Current Deactivation Current Allowable Current 2-channel Outputs Initial Insulation Resistance Allowable Short-circuit Rating Current DB9, Female 1 K ohm 3.3 mA 1.5 mA 4 mA Min. 100M ohm (at 500 Vdc) 5 mA (at maximum) Protocol IEEE 802.1w RSTP, 802.1s MSTP*, LEAPS SNMP Alarm Control Alarm relay Connector Alarm cut off Management LEDs Console port Telnet SSH SNMP LoopView GUI EMS Performance Monitor Alarm Queue OA&M Power Power PoE (Power over Ethernet) Power consumption Protection NO, COM, NC Terminal block ACO button Multi-color LEDs Protocol: Menu driven VT-100 Electrical: RS232, DCE Connector: DB9S, female v2 v1, v2, v3 Contains up to 500 alarm records which record the latest alarm type,alarm severity ,and date & time Link Status Update, Link Status Monitoring AC: Full range supports 100 to 240 Vac, 50/ 60Hz DC24: -18 to -36 Vdc DC48: -36 to -72 Vdc Both DC24 and DC48 are on-board fixed single/dual DC modules with dual feed DC input range: -44 to -57 Vdc (PSE for indoor only) 10 Watts maximum Over current protection fuse *Future Option 5 Physical and Environmental Dimensions 215 x 41.5 x 156 mm (WxHxD), 1U height Temperature range -20 to 70 °C Humidity 0 to 95% RH (non-condensing) Mounting Desk-top, wall mount , DIN rail Enclosure Type IP30 enclosure Standard Compliance IEEE 802.3, 802.3u, 802.3x, 802.1d, 802.1w, 802.1p, 802.1q Certification EMI/EMC Safety FCC15 subpart B class A, EN55022 class A, EN55024, EN300 386 IEC60950-1, EN60950-1 Front Panel View: IP6810 (dual 48Vdc with PoE option) IP6810 (dual 24Vdc without PoE option) IP6810 (AC power) 6 Application Illustrations: Point to Multipoint Application Half Duplex RS-485 Bus Mode Local SCADA Applications 7 Traffic Light Management Applications Video Surveillance Applications Remote SCADA Applications 8 (1) Up Upto to64 64remote remoteunits units (2) Master same installation as site #1 (4) Site #5 (3) Site #1 (5) Site #4 same installation as site #1 Site #2 same installation as site #1 Site #3 same installation as site #1 Master-to-slave Message Broadcast Optical Fast Ethernet Ring No Configuration Necessary in Advance for Installation Setup Procedure: (1) Set DIP switch to Master, connect both WAN ports and power up the unit (2) On VT100, set the master unit’s Auto-Discovery function to ENABLE (3) On remote site, set the unit’s DIP switch to Slave, connect both WAN ports and power up the unit (4) The master unit will automatically detect the slave unit and show the information on VT100 screen (5) BC LED will turn GREEN, which indicates the Link between Master and Site 1 is ON Auto-Configure (Plug-and-Play) Application LoopTelecom.com Worldwide LOOP TELECOMMUNICATION INTERNATIONAL, INC. ISO 9001/ISO 14001 8F, No. 8, Hsin Ann Road, Science-Based Industrial Park Hsinchu, Taiwan 300 Tel:+886-3-578-7696 Fax:+886-3-564-6272 www.LoopTelecom.com [email protected] Taipei, Taiwan North America 6F, No. 36, Alley 38, Lane 358, Rueiguang Road, Neihu, Taiwan 11492 Tel:+886-2-2659-0399 Fax:+886-2-2659-2325 [email protected] 8 Carrick Road Palm Beach Gardens Florida 33418, U.S.A. Tel:+1-561-627-7947 Fax:+1-561-627-6615 [email protected] © 2009 Loop Telecommunication International, Inc. Version 1 19 Nov 2009 Tianjin China No. 240 Baidi Road Nankai District Tianjin 300192 China Tel:+86-22-8789-4027 Fax:+86-22-8789-0344 [email protected] All Rights Reserved Subject to change without notice 9