Download 6750 BRTU

Transcript
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
Application Guide for
Model 6750 BRTU DS3 TAD Interface
with Lucent DMX
Spirent Communication
Revision
Author
Approval Date
A
Victor Afable
Dec 4, 2008
B
Victor Afable
Dec 9, 2008
Rev. B
Page 1
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
Table of Contents
1.0
BRTU-99 and DCS Introduction and Preparation --------------------------------------------------------- 3
1.1
Objective ----------------------------------------------------------------------------------------------------- 4
1.2 Description ---------------------------------------------------------------------------------------------------- 4
1.2 Equipment Drawings and Cable Running List----------------------------------------------------- 5-8
2.0
BRTU-Shelf Configuration ------------------------------------------------------------------------------------ 10
3.0
DS1 Circuit Access Test--------------------------------------------------------------------------------------- 16
4.0
REACT TEST RESOURCE Example ---------------------------------------------------------------------- 22
Spirent Communication
Rev. B
Page 2
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
Section 1.0
BRTU-99 and Lucent DMX DCS Introduction and Preparation
Spirent Communication
Rev. B
Page 3
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
1.0
Objective
This document is made to use as an application guide for setting up the Model 6750 BRTU and REACT
for accessing DS1 circuit using BRTU DS3 TAD Interface card from Lucent DMX.
This document does not cover the overall acceptance/verification and focused only in configurations
of Spirent Model 6750 BRTU-99 and REACT to access DS3 circuits from Lucent DMX. Additional
information may be obtained in the following documents for the purpose of troubleshooting, maintenance,
operation requirements, etc.
•
•
•
•
ATP-6700-085
6750 Acceptance Test Procedure
HKMN-6750-101 6750 Application Drawings.
PN-6750-104
Spirent Digital Test System Command Manual
Lucent DMX User Manual
Spirent documentation maybe obtain via web using the address shown below. Username and password
is required.
http://assure.spirentcom.com/extranet/authenticate.asp
Note
The Test Identifier, IP address, and test circuit used in this document are examples only.
Please refer to central office engineer for the assigned information’s
1.1
Description
This document consist of six sections
Spirent Communication
Section 1
Introduction and Preparation
Section 2
Model 6750 BRTU
Section 3
Circuit Access Test
Section 4
React Test Resource Example
Rev. B
Page 4
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
1.2
Equipment Drawings
1
2
LO C K
L OC K
DS3
TEST
F A
L
L O C K
DS3
TEST
DS3
TEST
F A IL
FA I L
B U SY
B U SY
F
3
F
E
4
DS3
TEST
L O CK
B US Y
E
F
7
L OC K
FA I L
B U S Y
F
E
6
DS3
TEST
F A IL
B U SY
F
E
5
LO C K
L O CK
DS3
TEST
DS3 TAD
INTFC
DS3 TAD
INTFC
F A IL
F A IL
FA I L
B U S Y
E
8
L O C K
B US Y
B US Y
S IG
S IG
E
F
9
LO C K
10
LO C K
11
DS1 FAD DS1 FAD+
INTFC
INTFC
F A L
FA
B U SY
LO C K
PVS
INTFC
F A
L
BU S Y
1
1
2
2
LO C K
13
PCM
TEST
L
F A
B US Y
1
2
3
12
L O C K
14
PCM
TEST
L
B U S Y
LO C K
15
PCM
TEST
LO C K
16
DATA
TEST
L O C K
17
DATA
TEST
L O C K
18
DS1
TEST
LO C K
19
20
LO C K
L O C K
21
L O C K
DS1
TEST
DS1
TEST
DS1
TEST
F AIL
F A IL
FA I L
FA L
FA I L
FA L
I
F AI L
F AI L
F A
B U S Y
B US Y
BUS Y
BU S Y
B US Y
BU S Y
B U SY
B US Y
B US Y
22
DS1
TEST
L
23
L O C K
L O C K
24
25
L O CK
SYSTEM
CTRL
L O CK
DS1
TEST
COMM
CTRL
F A L
F A IL
FA L
POWER
SUPPLY
F A IL
B US Y
B U S Y
B US Y
AL M
AC O
3
F
F
E
E
4
+ 5V
HD LC
L AM P
L C L
TE S T
A C T
P W R
P W R
P W R
P W R
P WR
P W R
P W R
PW R
P W R
PW R
P W R
P WR
P W R
P WR
P W R
P W R
P W R
PW R
PW R
P W R
P W R
P W R
PW R
PW R
P W R
C LK
LC L P O R T
EX P
6726-51
6726-51
1
2
6726-51
3
6726-51
4
6726-51
5
6726-51
6725-51
6
6725-51
7
8
6714-51
9
6714-54
10
Figure 1-1
6719-52
6718-51
12
11
6718-51
13
6718-51
14
6717-53
15
6717-53
16
6716-51
17
6716-51
18
6716-51
6716-51
19
20
6716-51
21
6716-51
6713-51
22
23
F1
7 .5 A
G M T
6712-58
6711-51
24
25
Model 6750 BRTU-99 Front View
E3
1
2
IN R
3
IN R
O U TR
EXP
SHF
O U TT
6
A SYNC C ONTROL
232/V .24 ( RJ45)
(11 PORT S) <9 .6 KBPS
1
J25 - J33
J39, J40
PVS IN TER FACE
530/V.11 (DB-25S )
E2
J20, J37
J44, J45
1
AN C
2
AC OM
E1
T B1
T B2
- 48 V D C
TB2
4 2 -5 6V D C
( 4 .8 A )
J1 9
SY N C
J 27
P IN1
J32
J 31
D ATA OUT
5
PO RT READY IN
6
DA TA IN
7
HA N DSHA K E OUT
8
FRA ME GN D
J 25
J37
PV S 2
J 44
PV S 3
J 45
PVS 4
J 30
M ADE IN TH E U.S.A.
SH LD
FR G N D
PIN
FR G N D
1/26
W /BL
J37
FR G N D
2/27
W /O
FA D 1 EQPT
J44
FR G N D
3/28
W /G
TAD 2 OR FAD 2 FAC
4/29
W /BR
5/30
W /S
6/31
R /BL
7/32
R /O
8/33
R /G
9/34
R /BR
10/35
R /S
11/36
B K/BL
12/37
B K/O
DS1/E1 SIGNA L - J21 (IN ) AN D J22 (OU T)
FR G N D
E5
PIN
J3 3
1200 B PS
8 DA T A
NO P ARITY
1 ST O P
E6
T
7
2
3
8
9
4
10
5
6
11
12
COM M
T A LK /M O N
Figure 1-2
HEK IMI AN LABS, IN C
15200 OM
OMEGA DRIVE
ROCKVILLE, MD 20850-3240
U.S.A.
TEL. +1- 301-590-3500
FAX. +1- 301-590-3680
J33
1200 BPS
8 DAT BIT
NO PA R ITY
1 S TOP BIT
FR G N D
J 26
J 28
S E RIA L NO .
J20
1
J 29
PORT RE ADY OUT
4
J19
R
J33
3
E XPANSION/BITS CLO CK
J18
J45
J46
SIGNAL G ND
E4
J1 8
SYN C
BAT RTN
J 39
2
R ESE T
TALK/MO N
12 LIN ES LO OP START ONLY
E5
E6
J2 0
PVS 1
VC OM
VN O
MODEL 6705-99
BROADBAND REMOTE
REMOT E TEST UNIT SHELF
FUNC TION
1
A LARM (AUD/VIS)
E3
P O WER - 48V DC
200W /4.8A
E1
J40
6705
P IN
DS3 IN/O UT (BNC )
AN O
VN C
5
6
( REAR PA NEL VIE W )
J46
ETH ER NET 10BASE -T
RST
A LARM S 3
4
Spirent Communication
HE K IM IAN
D S1/E1 O UT
UT (25/12 PAIR)
J47 - J78
E2
5
6
P ow e r
TB1
D S1/E1 IN (25/12 PA IR)
J18
J19
J22
IN T
4
5
8
J21
SYNC X.25 CONTROL
530/V.11 OR 232/V.24
(DB-25P) <64
< 64 KBPS
BI T S
C LK
IN T
E6
PIN
R
FUNCTION
T
TALK/MONITOR
R
T
1
7
LS TEST UNIT 11 DIAL LINE
2
8
LS TEST UNIT 12 DIAL LINE
3
9
LS TEST UNIT 13 DIAL LINE
4
10
LS TEST UNIT 14 DIAL LINE
5
11
LS TEST UNIT 15 DIAL LINE
6
12
LS TEST UNIT 16 DIAL LINE
1
7
LS TEST UNIT 17 DIAL LINE
2
8
LS TEST UNIT 18 DIAL LINE
3
9
DIAL LINE
LS TEST UNIT 19 DIAL
4
10
LS TEST UNIT 20 DIAL LINE
5
11
LS TEST UNIT 21 DIAL LINE
6
12
LS TEST UNIT 22 DIAL LINE
CO LOR CO DE
FUNC TIO N
TAD 1 OR FAD 1 FAC
FA D 3 EQPT
TAD 4 OR FAD 4 FAC
FA D 4 EQPT
TAD 5 OR FAD 5 FAC
FA D 5 EQPT
TAD 6 OR FAD 6 FAC
8
7
W15
W1 3
J75
J71
F A C IN
F A C IN
FA C O U T
FAC O U T
J76
J21
J2 2
T
7
2
3
8
9
4
10
5
6
11
12
C OM M
TA LK /M O N
J67
J 63
F AC IN
FA C O U T
J72
W16
J73
F A C IN
F AC O U T
FA C O U T
EQ P T I N
E QP T IN
E QP T O U T
E Q PT O U T
EQ P T O U T
E QPT O U T
W1-W16
J70
NORMAL
W8
J 65
E Q PT IN
J74
J60
W10
EQ P T IN
J78
IN
W12
J69
J59
F A C IN
J 64
J68
W1 4
J77
1
H IG H S PE ED
T E S T U NIT
6
5
4
W11
W9
W7
FA D 6 EQPT
E5
R
FOR DS3 TAD UNIT
USE FAC IN AND
FAC OUT
FA D 2 EQPT
TAD 3 OR FAD 3 FAC
J61
E Q P T IN
3
2
W5
J55
F A C IN
FAC O UT
J56
W6
J57
E Q P T IN
1
W3
J51
W1
J47
F A C IN
FA C IN
FAC O UT
FAC O UT
J52
W4
J53
E Q P T IN
J48
W2
J49
E Q P T IN
E QP T O U T EQ P T O U T EQ P T O U T E Q P T O U T
J 66
J62
J58
J54
J50
GND
OUT
Model 6750 BRTU-99 Rear View
Rev. B
Page 5
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
DS1
TE ST
DS1
TE ST
DS1
TE ST
DS1
TE ST
DS1
TE ST
DS1
TE ST
DS3
TE ST
DS3
TE ST
F AI L
F A IL
FA L
F A L
F A IL
F AIL
FA L
FA IL
F A IL
F A L
F AI L
FA IL
FA I L
F A IL
B US Y
BUSY
BUSY
B US Y
BUSY
B US Y
BUSY
BU S Y
B US Y
B US Y
B US Y
BU S Y
B US Y
S IG
SI G
2
F
E
F
BU S Y
SPIRENT
20
L O CI K
LO C K
21
LO C K
DS1
TE ST
DS1
TE ST
DS1
TE ST
DS1
TE ST
F A L
F AI L
FA I L
FA L
F A L
FA I L
F AI L
BUSY
BUSY
B US Y
BUSY
B US Y
BUSY
BUSY
DS1
TE ST
DS1
TE ST
DS1
TE ST
22
LO C K
23
LO C K
I
L O CK
24
I
P VS
I NT FC
COM M
CTRL
S YS TEM
CTRL
P OWER
S UP PLY
F AI L
F A IL
FA L
BUSY
B US Y
AL M
FA L
BU S Y
1
E
F
E
F
LO C K
I
25
I
I
SPIRENT
19
I K
LOI C
SPIRENT
18
LO C K
SPIRENT
17
LO C K
SPIRENT
16
SPIRENT
DS1
TE ST
1
DS3 TA D
I NT FC
LO C K
I
15
LO C K
SPIRENT
14
L O C KI
SPIRENT
DS3 TA D
I NT FC
13
I
SPIRENT
DS3
TE ST
L OCK
12
I
SPIRENT
DS3
TE ST
LO C K
11
SPIRENT
L O CI K
SPIRENT
P VS
I NT FC
10
SPIRENT
LO C K
SPIRENT
9
SPIRENT
LO C K
SPIRENT
8
SPIRENT
L O CK
I
7
SPIRENT
LO C K
6
SPIRENT
SPIRENT
LO C K
5
SPIRENT
LO C K
I
4
SPIRENT
SPIRENT
LO C K
I
3
SPIRENT
LO C K
2
SPIRENT
L OC K
1
ACO
2
E
3
3
4
4
+ 5V
HDL C
LA M P
LC L
T EST
AC T
PW R
PWR
PW R
PW R
PW R
PW R
PWR
PW R
PWR
PWR
PWR
PW R
PWR
PW R
PW R
PWR
PW R
PWR
PWR
PW R
PW R
PWR
PWR
PW R
P WR
C LK
L CL P O RT
E XP
6716-51 6716-51
6716-51
6716-51
1
3
4
2
6716-51
5
6716-51
6716-51
6719-52
6
7
8
6726-51
9
6726-54
10
Eigh t Low Speed Test Cards
6725-51
11
6725-51
12
6726-51
67 26-51
13
6716-51
14
15
6716-51
16
Six High Sp eed Te st Car ds
Figure 1-3
6716-51
17
6716-51 6716-51 6716-51
18
19
20
6716-51
6719-52
6713-51
21
22
23
F1
7 5A
G MT
6712-58
24
6711-51
25
Eigh t Low Speed Test Cards
Model 6750 BRTU-95 Front View
E3
1
IN R
2
IN T
3
IN R
4
IN T
5
OU T R
SYNC X. 25 CON TRO L
53 0 /V. 11 O R 23 2/V. 24
(DB- 25 P) < 64 KBP S
BIT S
C LK
EXP
SHF
DS 3 IN /OUT ( BNC)
( W1 -W1 2)
E5
E5
E6
TAL K/MO N
16 LIN ES LO OP ST ART ON LY
J2 0, J37 , J4 4, J4 5
J7 9, J80 , J 81, J8 2
8
1
E1
E2
R ST
1
A LA RM S
TB 1
T B1
T B2
RE SET
E3
EXPANSIO N/BIT S CL OCK
PIN- 67 50
2
A CO M
3
A NO
4
V NC
5
V CO M
J1 8 S Y NC
J 79
PVS 5
J 19 S Y NC
PIN 1
E1
BAT RT N
J3 3
J3 2
J27
J29
J31
9
R
J 82
PVS 8
J 25
J2 6
J2 8
J3 0
T
LS TEST UNI T 1 DI AL LINE
2
3
10
11
LS TEST UNI T 2 DI AL LINE
LS TEST UNI T 3 DI AL LINE
4
12
LS TEST UNI T 4 DI AL LINE
5
13
LS TEST UNI T 5 DI AL LINE
6
14
LS TEST UNI T 6 DI AL LINE
7
15
LS TEST UNI T 7 DI AL LINE
8
16
1
9
LS TEST UNI T 8 DI AL LINE
LS TEST UNI T 15 DI AL LINE
SIG NAL G ND
2
10
LS TEST UNI T 16 DI AL LINE
PORT R EADY OUT
3
11
LS TEST UNI T 17 DI AL LINE
4
D A TA O UT
4
12
LS TEST UNI T 18 DI AL LINE
5
PO RT READY I N
6
DA T A IN
5
6
13
14
LS TEST UNI T 19 DI AL LINE
LS TEST UNI T 20 DI AL LINE
2
3
1
7
7
HAND SHAKE O UT
7
15
LS TEST UNI T 21 DI AL LINE
2
8
8
F R AME GND
8
16
LS TEST UNI T 22 DI AL LINE
3
9
4
10
6
J4 6
J8 1
PV S 7
T AL K /M O NI TO R
T
1
SH LD
5
TB 2
4 2 - 56 Vd c
( 4 .8 A)
J3 9
J 80
PVS 6
E4
V NO
J 40
F UNCT ION
FUNCTI ON
P IN
R
1
- 48 V DC
J3 3
1 20 0 B P S
8 DA T A
N O P A R I TY
1 S TO P
11
SPIRENT
MOD EL 6705-95
BR OADBAND R EM OT E TEST UNI T SHELF
S E RI A L NO .
M A DE I N T HE U. S . A .
J20
PVS 1
J 37
PVS 2
J44
PVS 3
J4 5
PV S 4
E7
HI G H S P E E D T E S T UN IT
12
14
E6
R
13
12
11
10
W9
W7
W5
W3
W1
J6 7
J63
J59
J55
J51
J47
F AC IN
F A C IN
F AC IN
F AC O UT
FAC OU T
F A C IN
F A C OU T
T
PI N 1
SHL D
1
9
J1 8
F R G ND
2
10
J1 9
F R G ND
FA C I N
FA C I N
F AC O U T
F AC OU T
J6 8
J64
J60
J56
J52
J48
W12
W 10
W8
W6
W4
W2
3
11
J7 9
F R G ND
4
12
J8 0
F R G ND
5
13
J8 1
F R G ND
6
14
J8 2
F R G ND
7
15
8
16
J6 9
J 65
EQ PT I N
E QP T IN
E Q PT O UT
EQ PT OU T
J7 0
J 66
J61
EQ PT IN
J57
E Q PT I N
J53
E Q PT I N
J49
E5
FO R D S 3 T A D UN IT
US E F A C IN A ND
FA C OU T
J58
J54
EQ PT IN
J50
R
NO RMA L
G ND
T
1
9
2
10
3
11
4
12
5
13
6
W 1 -W12
6
3
7
8
E7
E Q PT O U T EQ PT O UT EQ PT O UT E QP T O UT
J62
5
2
9
W11
F AC O UT
1
4
E4
PI N 1
SH LD
J 20
F R G ND
J 37
F R G ND
J 44
F R G ND
J 45
F R G ND
14
7
15
8
16
C O MM
TA L K/M O N
C O MM
T A LK /M O N
Figure 1-4
Spirent Communication
(R EAR PANEL VIEW)
E2
P OWER -4 8VDC
20 0 W/4 .8A
A NC
6
Po we r
AL AR M (AUD /VIS)
J4 6
ET HER NET 1 0BASE- T
5
6
E6
PIN
J2 5 - J3 3
J3 9, J40
PVS I NT ER FACE
5 30 /V.1 1 (D B-25 S)
OU T T
6
J47 - J70
J18 , J1 9
ASYN C CON TRO L
2 32/V .2 4 ( RJ4 5)
( 11 PORT S) <9 .6 KBPS
Model 6750 BRTU-95 Rear View
Rev. B
Page 6
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
11’6”
73
70
70
65
65
60
60
55
55
50
l
50
45
Note:
45
BRTU-99 Relay Rack Configuration.
7’
Filtered Fuse Panel
40
40
35
35
Heat Baffle is a part of the unit
30
Controller Shelf
25
30
BRTU-99
25
Heat Baffle is a part of the unit
20
20
15
15
10
10
5
5
0
0
6” Box
2” SPACING
Figure 1-5
Spirent Communication
Typical Rack Elevation (7’ X 1” X 23”) for 6750 BRTU-99 and BRTU-99
Rev. B
Page 7
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
Ethernet
Tellabs
LUCENT
DMX
Tellabs
T6500
T6500
Ethernet Hub
DS3
TAD
OC12
OC12 TAP Signal
LGX Patch
DS3
PatchPanel
Panel
X-Connect to BRTU-99
IP
NETWORK
Patch
Panel
DS3LGX
Patch
Panel
REACT and TSC
Control
Ethernet
COAX DS3 Test Bus
DS3 TAD
OC12
Card
FAC
(IN)
(OUT)
IN OUT
J46
Ethernet
7121-66P
TB1
TB2
-48Vdc
6705-99
6750
BRTU
BRTU
REACT
Figure 1-6
Spirent Communication
Model 6750 BRTU-99
Rev. B
Page 8
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
Cable Running List
Run
No.
Cable
Type
Code
From
Equipment
To
Equipment
Remarks
20AWG
Red/Black
BRTU-99
Connectors
TB1 (Black)
TB2 (Red)
-48V Fuse Panel
-48VDC Power Supply
2
7121-66P
Ethernet Hub
IP Communication to REACT
3
6750-C5
BRTU-99
J46
LDMX DS3 TAP
Port (FAC)
BRTU TAD card Module installed
in Slot #1
J47 - IN
J48 - OUT
DS3 TAD connection – to be X-connect to DMX DS3 TAD
Port
EQPT
PWR
1
COMM/
TEST
BUS
Refer to Figure 1-6 for more information
Spirent Communication
Rev. B
Page 9
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
2.0
Model 6750 BRTU Shelf Configuration:
VBATT EN 1-2
VBATT DIS 2-3
Battery
Pull the 6750 SCU card and ENABLE the battery backup by placing the BLUE JUMPER to pin 1 and pin 2
of J1 connector. If the BRTU is equipped with eSCU the battery backup is jumper is J3 enable the battery
by placing the BLUE jumper in pin 1 and pin 2.
J3
12 3
Set up a VDT (VT100) or a laptop PC for direct connection to the fixed port at 9600 bps, 8 data bits, no parity, and
1 stop bit (9600, 8, N, 1).
Using the 9-pin male/ female Straight Cable, connect the PC to the craft port at the front of the BRTU-99 unit.
2.1
Login to the BRTU-99
Enter Command:
2.2
ACT-USER::SUPER:CTAG::SUPER;
Edit Date and Time
Enter Command:
ED-DAT:::CTAG::050906,101500;
YRMMDD,HHMMSS
2.3
Edit Site Identifier (SID)
Enter command:
ED-SID:HEKIMIAN-6700::CTAG::HKMN-6750;
OLD/CURRENT SID
Spirent Communication
NEW SID
Rev. B
Page 10
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
2.4.
2.5.
Edit BRTU-99 Equipment Table
Enter Command:
ED-ATTR-EQPT:::CTAG::TSC=ON;
Enter Command:
ED-ATTR-EQPT:::CTAG::TMO=5000;
Retrieve the Equipment table and response should be as shown below:
Enter command:
RTRV-ATTR-EQPT:::CTAG;
Response:
HEKIMIAN-6750 00-02-25 05:57:57
M D COMPLD
"SHELF=99 TSC=ON REPORT=FULL EQLR=0 TMO=500SECS LEV=ABS"
"IDLE=TC CYCLETEST=ON DS1DS3=OFF IPCHECK=0MINS"
2.6
Retrieve the BRTU firmware version
Enter Command:
RTRV-VRSN-EQPT:::CTAG;
HEKIMIAN-6750 00-02-25 05:57:57
M D COMPLD
/*CARD
APPL/PGM1 BOOT/PGM2 DSP
HW ASSY
" TD3-01-01: RA02.20 RA02.20
6700-1472-02 REV B3 OPT
" DS1-01-11: RG08.10 RF03.30
6700-1280-03 REV F OPT
" DS1-01-12: RG08.10 RF03.30
6700-1280-03 REV F OPT
" DS1-01-13: RG08.10 RF03.30
6700-1280-03 REV F OPT
" SCU-01-24: RH14.20 RH14.18
6700-1652-01 REV B7 OPT
" PSU-01-25:
3500-1624-09 REV F2 OPT "
*/
"
"
"
"
"
Results shown above are the latest firmware version of the BRTU-99. Ensure that TD3 card
and DS1 cards shows up in the response.
HEKIMIAN-6750 00-01-01 00:00:00
M FDSA COMPLD
/*CARD
APPL/PGM1 BOOT/PGM2 DSP
HW ASSY
" DS1-01-01: RA07.70 RE03.10
6700-1280-01 REV C9 OPT
" DS1-01-02: RA07.70 RE03.10
6700-1280-01 REV C9 OPT
" TD3-01-09: RA02.20 RA02.20
6700-1472-02 REV C3 OPT
" SCU-01-24: RH14.20 RH14.18
6700-1652-01 REV B8 OPT
" PSU-01-25:
3500-1624-09 REV F8 OPT "
*/
"
"
"
"
Results shown above are the latest firmware version of the BRTU-95. Ensure that TD3 card
and DS1 cards shows up in the response.
The eSCU firmware should be at least version 14.20 or higher.
Spirent Communication
Rev. B
Page 11
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
2.7
Edit the BRTU-99 IP address as required.
Enter Command:
ED-ATTR-IP::J46:CTAG::ADDR=172.25.44.181; --- IP Address
Enter Command:
ED-ATTR-IP::J46:CTAG::MASK=255.255.255.128; --- Subnet Mask
Enter Command:
ED-ATTR-IP::J46:CTAG::GATEWAY=172.25.44.180; --- Gateway
NOTE:
2.10
Changes to the TCP/IP parameters will take effect only after the BRTU-99 has been
rebooted. You need to issue the INIT-SYS:::CTAG::4; command for the TCP/IP
changes to take effect.
Enter Command:
INIT-SYS:::CTAG::4;
To Reboot the BRTU
Enter Command:
ACT-USER::SUPER:CTAG::SUPER;
To login after reboot
Edit the BRTU-99 TAU
2.10.2 TAU table set up for the Lucent DMX:
Note: The Test Identifier (TID) that is used in this document are examples only refer to REACT
administrator for the assigned TID.
The TAU is identified by its unique TID. You have to create the TAU follow by the TAP table. Once the
TAU is created, then TAP can be created for that TAU. The following commands are to set the TAU
table.
Enter Command:ED-DB-TAU::TESTDMX:CTAG::TYPE=LDMX,JID=J46,ADDRESS=10.1.197.181-3082
,CTYPE=SOCKET,PERSIST=YES;
Enter Command:
Enter Command:
TESTDMX =
TYPE =
JID =
ADDRESS=
CTYPE=
UID =
PID =
Spirent Communication
ED-DB-TAU::TESTDMX:CTAG::UID=ossdev,PID=password,
ED-DB-TAU::TESTDMX:CTAG::REVISION=06.00
is the given Test Identifier for the ADM (TESTDMX is use as en example only
contact your REACT admin for the assigned TID to use). This should match with the
TID in REACT test resource set for that ADM and BRTU-99.
Access Type enter LDMX for Lucent DMX
J46 as the TSC port
Address of the Lucent DMX and default port. The default port for DMX is 3082
Connection Type (TELNET)
ossdev (just an example can be case sensitive)
password (just an example can be case sensitve)
Rev. B
Page 12
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
2.10.3 Retrieve the TAU Table:
Enter Command:
RTRV-DB-TAU::ALL:CTAG;
HEKIMIAN-6750 00-02-25 05:57:41
M D COMPLD
/* TID
TYPE
REVISION AIDFMT ROUTE
/* JID ADDRESS
CTYPE PERSIST MAXCONN
/* UID
PID
LOGIN
*/
" TESTDMX
LDMX
00.00 000 0
J46 10.1.197.181-3082
SOCKET YES
ossdev
password
Y "
Spirent Communication
*/
*/
1
Rev. B
Page 13
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
2.11
TAP Table Set Up
Edit the BRTU TAP table for Lucent DMX by entering the following commands:
In our example, the BRTU DS3 TAD card is inserted in slot 1 of the BRTU-99 shelf. Therefore, when
setting the TAP for the aforementioned DS3 card TPID #1 should be use. Shown below is the TPID
assignment per slot use for BRTU-99 and BRTU-95 also see figure 2-1 (next page) for more information
BRTU-99
BRTU-95
Slot 1 = TPID=1
Slot 2 = TPID=3
Slot 3 = TPID=5
Slot 4 = TPID=7
Slot 5 = TPID=9
Slot 6 = TPID=11
Slot 7 = TPID=13
Slot 8 = TPID=15
Slot 9 = TPID=1
Slot 10 = TPID=3
Slot 11 = TPID=5
Slot 12 = TPID=7
Slot 13 = TPID=9
Slot 14 = TPID=11
Enter Command:
ED-DB-TAP::1:CTAG::TID=TESTDMX,TAPID=A1-1-1-1,
TPA=FFFFFFFFFFFFFF,TCA=TTTTTTTTTTTTTT;
TAPID=A1-1-1-1 –
Enter Command:
2.12
This is the DMX TAP port number
ED-DB-TAP::1:CTAG::FR=M23,LC=B3ZS;
Retrieve the TAP table:
Enter Command:
RTRV-DB-TAP::ALL:CTAG;
HEKIMIAN-6750 00-02-25 05:57:46
M CTAG COMPLD
/* TPID TID
STATUS TAPID
TAPID2
*/
/*
TYPE
FR LC EQ
TPA
TCA
*/
/*
CONCAID
ACCESSRATE TAPTYPE TIMING S-TRACE
/*
OPTIONS
"
1 TESTDMX
F
A1-1-1-1
0
LDMX
M23 B3ZS 1
FFFFFFFFFFFFFF
1
0
0
0 01
Spirent Communication
*/
TTTTTTTTTTTTTT
Rev. B
Page 14
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
12 13 14
18 19
20 21
LS Test
LS Test
16 17
LS Test
15
LS Test
11
LS Test
10
LS Test
9
LS Test
LS Test
HS
8
LS Test
LS Test
7
HS
LS Test
6
HS
LS Test
5
HS
LS Test
4
HS
LS Test
3
9 11
10 12
22 23
eSCU
2
7
8
POWER SUPPLY CARD
1
5
6
COM
LS Test
3
4
LS Te
Test
st
1
2
HS
BRTU-95 TPID Assignment:
24 25
BRTU-99 TPID Assignment:
BRTU-99 Main Shelf (ED-ATTR-EQPT:::CTAG::SHELF=99;)
LS Test
LS Test
LS Test
LS Test
LS Test
LS Test
LS Test
COM
eSCU
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24 25
PSU
LS Test
7
LS Test
6
LS Test
5
LS Test
4
LS Test
3
20
21
22
LS Intfc
2
17
18
19
LS Intfc
1
15
16
HS
HS
13
14
HS
11
12
HS
9
10
HS
7
8
HS
5
6
HS
3
4
HS
1
2
(8) Test Bus Max.
Figure 2-1 BRTU-95 and BRTU-99 TPID Assignment
Spirent Communication
Rev. B
Page 15
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
3.00 DS1 Circuit Access Test
1. Assure that the signal in BRTU TAD are present by checking if the TAD LED are lit. If the
signal is not present fix it before moving on.
2. Ask the office engineer for a test circuit that you can access and split. Be sure that the digroup that you
are about to split is not in service. If they can’t find a circuit for you just make a monitor access
but DO NOT split that circuit.
3. The circuits use in this example will come in the form of B1-6-1-1 and A1-2-1-1. See Lucent DMX manual for
more information on pre and post 06.000 release Access Identifier information channel and path protection
groups
4. You need to have two digroups that are cross-connected together in order to test both directions of the of the
circuit. See Drawing below for more detail.
Note:
The Test Circuit that are shown below and are examples only. Please
refer to Office Engineer for the assigned test circuit to use
Lucent DMX
Hardwire Loop
B1-6-1-1
A1-2-1-1
DS3 TAD
Hardwire Loop
BRTU
Spirent Communication
Rev. B
Page 16
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
DS1 Circuit Access Test
3.0.3.1 Enter the following command to access DS1 circuit
Enter command: CONN-TACC-T1:TESTDMX:A1-2-1-1:ATP:999:MONE;
Response:
TESTDMX 07-08-27 15:11:05
M ATP COMPLD
Note:
Verify the response from the access command is similar to the response as shown above. This is
an indication of a successful access.
3.0.3.2 Split the access with direction towards looking at the F direction
Enter Command:
CHG-ACCMD-T1::999:D:SPLTF;
Response:
TESTDMX 07-08-27 15:11:56
M D COMPLD
3.0.3.3 Insert test signal
Enter Command:
CHG-TSTSIG-T1::999:AAA:10101010,S,A;
TESTDMX 07-08-27 14:59:09
M D COMPLD
3.0.3.4 Start the test by entering the following command:
Enter Command:
Spirent Communication
MEAS-SIG-T1::999:AAA:9999-59,S,O-10101010,S,A;
Rev. B
Page 17
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
3.0.3.5 Display the test results by entering the following command:
Enter Command:
REPT-RSLT::999:CTAG;
TESTDMX 07-08-27 14:59:34
M CTAG COMPLD
0-06, 0
BPV ES=NA, TE=NA
PAT ES=0, TE=0
PAT SES=0
CBIT ES=NA, TE=NA
FMBIT ES=0, TE=0
FEBE ES=NA, TE=NA
PBIT ES=0, TE=0
PSL=0, PSLS=0
FSL=0, FSLS=0
UAS=0, %AS=100
DGRM=0, %DGRM=0
%EFS=100, BITS=1.853e+07
Verify the test results returns with no error
3.0.3.6 Insert Bit error by entering the following command:
Enter Command:
TST-INSERRBITS::999:D:45,,BIT;
Note – This command injects 45 bit error in the test. Verify the error by displaying the results by
entering the command in the next step.
Spirent Communication
Rev. B
Page 18
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
3.0.3.7 Display the test results by entering the following command:
Enter Command:
REPT-RSLT::999:CTAG;
TESTDMX 07-08-27 14:59:53
M CTAG COMPLD
0-26, 0
BPV ES=NA, TE=NA
PAT ES=1, TE=45
PAT SES=0
CBIT ES=NA, TE=NA
FMBIT ES=0, TE=0
FEBE ES=NA, TE=NA
PBIT ES=0, TE=0
PSL=0, PSLS=0
FSL=0, FSLS=0
UAS=0, %AS=100
DGRM=0, %DGRM=0
%EFS=96, BITS=1.2536E9
Verify results return with 45 Bit Error
3.0.3.8 Stop the test by entering the following command:
Enter Command:
DISC-MEAS::999:CTAG;
3.0.3.9 Change the direction of the test to EQUIPMENT direction by entering the following command:
Enter Command:
CHG-ACCMD-T1::999:D:SPLTE;
TESTDMX 07-08-27 15:13:09
M D COMPLD
Spirent Communication
Rev. B
Page 19
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
3.0.3.10
Initiate the measurement by entering the following command:
Enter Command:
3.0.3.11
MEAS-SIG-T1::999:AAA:9999-59,S,O-10101010,S,A;
Display the test results by entering the following command:
Enter Command:
REPT-RSLT::999:CTAG;
TESTDMX 07-08-27 14:59:34
M CTAG COMPLD
0-34, 0
BPV ES=NA, TE=NA
PAT ES=0, TE=0
PAT SES=0
CBIT ES=NA, TE=NA
FMBIT ES=0, TE=0
FEBE ES=NA, TE=NA
PBIT ES=0, TE=0
PSL=0, PSLS=0
FSL=0, FSLS=0
UAS=0, %AS=100
DGRM=0, %DGRM=0
%EFS=100, BITS=1.6397E9
Verify the test results returns with no error
Spirent Communication
Rev. B
Page 20
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
3.0.3.12
Insert Bit error by entering the following command:
Enter Command:
TST-INSERRBITS::999:D:70,,BIT;
Note – This command injects 70 bit error in the test. Verify the error by displaying the results by
entering the command in the next step.
3.0.3.13
Display the test results by entering the following command:
Enter Command:
REPT-RSLT::999:CTAG;
1-45, 0
BPV ES=NA, TE=NA
PAT ES=1, TE=70
PAT SES=0
CBIT ES=NA, TE=NA
FMBIT ES=0, TE=0
FEBE ES=NA, TE=NA
PBIT ES=0, TE=0
PSL=0, PSLS=0
FSL=0, FSLS=0
UAS=0, %AS=100
DGRM=0, %DGRM=0
%EFS=99, BITS=1.6397E9
Verify the error injected of 70 bit error appears in the test result
3.0.3.14
Stop the test by entering the following command:
Enter Command:
3.0.3.15
Release the access by entering the following command:
Enter Command:
Spirent Communication
DISC-MEAS::999:CTAG;
DISC-TACC::999:CTAG;
Rev. B
Page 21
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
4.0
REACT TEST RESOURCE CONFIGURATION USING OLD RESOURCE SERVER
FOR BRTU DS3 TAD INTERFACE WITH THE LUCENT DMX DCS.
4.0.1
Set the Telnet Database to include the address of the BRTU
%*BRTU 878 TCPIP_172.25.44.181_7010
Note:
IP address for BRTU
Address and ports used are examples only; refer to REACT Admin for the
REACT Test resource for DS1 Test:
4.0.2
From REACT Administration click on EDIT then click on Test Resources (Old) and Edit Resources as
shown in the example below.
4.0.3
Edit Resources should appear as shown below. Enter “2” to insert new test resource.
Spirent Communication
Rev. B
Page 22
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
Enter the following information to create one DS1 Test Resource
Enter COM-LINK Direct/Modem/Remote/PAD X28 (D/M/R/P): R
6439 module, DATS, DC/B, ADM, none (6439/DATS/D/A/N): N
Enter ABILITY: ANALOG,CHANNELIZE,PERFORMANCE,ANALOG/CHANNELIZE,DDS,
DS3/E3,CELLSITE,ISDN,ADM LOOP,DSLAM,ICON,ATM SW,ADSL RTR,IP TPUT,FR
SW,STM,PON,STS1,STS3C,STS12C,VC3,STM1,STM4,IP_NA/C/P/(A/C)/DDS/3/S/I/ADML/D/ICON/SW/R/IP/F/M
/PON/S1/S3/S12/VC3/STM1/STM4/IP_TLS/IP_VPN): P
Is this a TR834 , natively supported , or foreign site (T/N/F): T
Enter Modem number: %*BRTU
Enter name (15 chars. max): TESTDMX
Is this a CEPT device(Y/N)?: N
Is this a Hekimian BRTU (Y/N)?: Y
Is this resource a 6750 RTU or 6750 TSC? (R/T): T
Enter FAD/TAD hardware number, 0 disables FAD locking (00-99)?: 0
Is this a STSx TAD or other access(T/O)?: O
Is this a DS3 FAD, DS3 TAD, or other access(F/T/O)?: T
Enter DS1 test port in the DS3 TAD (1-14)?: 1
Individual DCS port, 6439 port (I/C): I
Enter type of DCS/EDSX: WECO,WESCOM,DXCS,TELLABS,ATT3,TA203,D3-1,RDX,
TAIU,TITAN-S,TITAN-D,NTEL,DCSF,RTU,TDAX,NORTEL,DSXpert,TDAX NB,OTHER
(W,S,D,T,A,2,3,R,+,I,5,N,F,U,X,E,P,B,O): 5
Enter DCS port:
Enter DCS link number, 0 to ignore: 0
Enter digroup/fad for test set: 1
Do you have a Remote controlled Reset Box for this resource (Y/N): N
Enter REACT 2001 primary test server host: HOST
Enter REACT 2001 secondary test server host: HOST
Enter REACT 2001 RTU Label: RTU
Display only this position? (y/n): Y
Spirent Communication
Rev. B
Page 23
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
4.0.4
Example of REACT Test Resource
TEST RESOURCE STATUS
TYPE
POS. TP/SIDE ABILITY LINK
LONG TERM
DEV. 3965 3705 MODEM/PORT1 PORT2
PASSWORD DCS/LNK D-PORT STATUS TEST NAME
--------------------------------------------------------------------------------------------------------------------------------192 001/- DS1
4.0.5
REMOTE ---- TSC
%*BRTU
TA/DPU
TA/DPU
FREE
FREE TESTDMX
Establish the access using the REACT and verify a successful access from the REACT.
Spirent Communication
Rev. B
Page 24
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
4.1
REACT TEST RESOURCE CONFIGURATION USING NEW RESOURCE SERVER
FOR BRTU DS3 TAD INTERFACE WITH THE LUCENT DMX DCS.
4.1.1
Login to REACT Administration. Click on Edit, Test Resources, and Edit Resource as shown below.
4.1.2
Start on setting the Communication link information by choosing “Commlink”. Enter the Link ID “BRTU”
(as our sample). Enter the IP address of the BRTU and port number of 7010. Enter comment in the
comment box; the comment box is used for reference only. When the information’s are entered as shown
below click on the Save button.
Spirent Communication
Rev. B
Page 25
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
4.1.3
Enter the test set information by choosing the test set. Enter the SID for the BRTU. Enter “SPIRENT” for
vendor and “6750” for model. Enter the CommLink ID “TESTDMX” is the example entry. This is the
commlink ID you have entered in previous step (4.1.2). Click on the save button to save the new entry.
4.1.4
Create the Network Element – Enter the Target Identifier of the ADM. The TID should be identical with
the SID of the ADM and the TID in the BRTU TAP and TAU table. Enter the information as shown below
followed by the Save button.
Note:
Spirent Communication
For REACT prior release 4.000 select Tellabs as Vendor and T5500 as model
Rev. B
Page 26
Application Guide for Model 6750-99 and 6750-95
with Lucent DMX DCS
4.1.5
Set the Network Element for BRTU and Lucent DMX as shown below. You need to create one Network
Element table per DS1 test.
4.2
Contact REACT administrator and establish the access using the REACT and verify a successful access
from the REACT.
END
Spirent Communication
Rev. B
Page 27