Download G90 GSM & MMS ALARM
Transcript
G90 GSM & MMS alarm manual Quick programming Installation 1、Insert SIM card, which MMS is activated, without PIN code. 2、Plug in power, +12V, and turn on. It sounds 2 beeps and 1 beep around 20 seconds later to indicate system is ready. If 2 beeps not heard, remove the power, check, re-insert the SIM, and re-power after 3 minutes. 3、You can ask your operator for correct mms setting 4、Follow the examples to program system Send sms:“000000M#090012345,090123455 [email protected]” to the SIM card number in G90. Key in: “000000 M#0932345678,0935111111,0930333333 [email protected]“ Send this short message to console phone number Confirmation: administrator will receive a SMS for confirmation as “M: #0932345678,0935111111,0930333333 [email protected]“to indicate programming is successful. #0932345678 represents this is the administrator phone number. ,09351111111 and 0930333333 are general user. (Note: Administrator does not need password to program and operate the system; password is necessary for other user(s) to perform the work. Commands 1. The commands in the table to operate the system (1) (3) (5) (7) (9) N - Program password E - Program receiver email address D - Check System Settings <m><n> -SMS to check images U –Accessories alarm (2) (4) (6) (8) M –Program receiver phone number A1/A0 –Arm/Disarm T - Listen-in C - Default settings 2、Setting examples N: To Program Password (default password 000000) Send“000000N111111”SMS to main unit phone number Confirmation: user will receive a SMS for confirmation as N: 111111 M: To Program Receiver’s Phone Number Send“000000M#0932345678, 0935111111”SMS to main unit phone number 2 G90 GSM & MMS alarm manual Confirmation: user will receive a SMS for confirmation as “M:#0932345678,0935111111” to indicate programming is successful. Send“000000M” SMS to main unit phone number Confirmation: user will receive a SMS for confirmation as M-deleted E: To Program Email Address Send“[email protected],[email protected]”SMS to main unit phone number Confirmation: user will receive a SMS for confirmation as “E:[email protected],[email protected]” to indicate programming is successful. Send“000000E” SMS to main unit phone number, users will receive a SMS for confirmation as E-deleted To Activate/Release the System Send“000000A1” SMS to main unit phone number Confirmation: user will receive a SMS for confirmation as “detector on” to indicate programming is successful. Send“000000A0” SMS to console phone number Confirmation: user will receive a SMS for confirmation as “detector off” To check the pictures by sending SMS Password+m+n The main unit will send mms to user’s mobile phone and E-mail. M refers to one of video input.(There are 4 in total and it is from 1 to 4) N refers to 1-7 pictures. Ex.: Sending 00000011 to the SIM card number in the system. User’s will receive 1 picture taken by video 1.It will display the information in the mms. D: To Check System Settings Send“000000D” SMS to main unit phone number Confirmation: user will receive a SMS for confirmation of what you have programmed. T: To listen in (need to connect one Mic.) Send“000000T+phone number” SMS to main unit phone number In 1 minute, system will call the phone number and the users can listen in the premise. If you just send 000000T, the system will call the phone which sends the sms. 3 G90 GSM & MMS alarm manual Ⅰ、Products introduction 1、1 Introduction This system is a brand new Hi-Tech product in the wireless communication era, it has integrated mobile transmission technology and IR image monitoring and thermo detection such kinds of security technologies. It has breaking thru the limitation of conventional CCTV system that transmitting by hardwire cable/modem which is difficult to install and has higher cost and limited by the installation environment, it also has problem of easy to be invaded. This product combines the future mobile user’s needs to let any mobile phone user (must have GPRS/MMS/SMS function) can use their mobile phone and mailbox function to back up the image information (to avoid the destroy of evidences), can real-time receives the alarm messages from any remote location by the devices or monitoring the real-time voice and image from the site for immediate identification. It meets various demands from sectors of household, office, factory, stores….etc. 1、2 Features IR & camera detecting, the double detection technology can eliminate the false alarm caused by environmental reasons. Can connect one to four cameras Send pictures to your mobile phone or E-mail when it alarms. Use mobile phone or computer to check the picture anytime wherever. With IR night vision camera, it provides full time 24 hours day and night monitoring function. Remote listen in function Send pictures and auto-dial to inform the users when it alarms. Remote control the system, easy to operate 4 G90 GSM & MMS alarm manual 1、3 Products pictures 1、Remote control antenna 6、Power indicate light 2、GSM antenna 7、Power input 3、COM1 port 8、GSM Network indicate light 4、4 video input connection 9、COM2 port 5、SIM socket 1、4 Package List Standard packing: (1) One Main unit (2) Two Antennas (3) One adaptor (4) Two remote controls (5) One user manual Optional: (1) 1-4 box cameras (2) PIR (3) Other sensors/detectors (4) Remote control (At most can match 10 pcs) Please check all components in the package. 5 G90 GSM & MMS alarm manual 1 、5 Major Technical Parameters PIC Format JPEG Resolution 320×240 Remote Effective Range < 100 m Working Temperature 0-50℃ Relative Humidity 10-90%,non-condense 2、Operation 2、1 Major Function 2、1、1 Active reviewing function ( 1) By Calling Make sure the feature of MMS is activated for both caller and the main unit. You just call the unit phone number, and it will hang up the call. After taking a picture of the premise, it will send the picture to the caller and the first email address if any email address has been programmed. Note: You can only check the main unit by calling. If you want to check other cameras, you need to send sms to check it. If the user already sends sms to check different cameras, the default checking route by sms will be changed. Ex.: The you sent sms 00000021 to the main unit, you will see one picture from video-2. (2) By Sending SMS SMS content: Password+Video1+picture quantity EX.: sending 00000012 to the main unit SIM card number 000000 is the factory default password,1 stands for Video 1. 2 stands for sending 2 pictures to the user’s mobile phone and mail box. Note: If none phone number is programmed as alert receiver, any mobile phone with feature of MMS activated can perform this function. Only the administrator and user(s) can do so when receiver phone numbers are programmed, while SMS plus password for other user(s). 2、1、2 Infrared Heat & Motion Detection Infrared heat & motion is active under system arming mode to detect any motion object in the premise. If any motion object, i.e. intruder, is detected, system will send 3 pictures to designated receiver (The first mms is 1 picture, and two 6 G90 GSM & MMS alarm manual in the second mms). After sending pictures, system calls receiver and it will call for 5 times if nobody answers the phone. It will alarm again in 10 minutes when it detects the intruders. 2、1、3Listen in(Need to connect a Mic.) You just need to send the SMS to the console, and you will receive call back for the receiver to listen in the sound of premise. You can send SMS: “T+ telephone number or mobile phone number,” in one minute console will phone the number behind of the “T”. Users answer it and they can monitor the voice of the scene. Send SMS: “T”, console will call the mobile phone number which sends SMS. 2、2 Remote control guide 2、2、1 Button instruction 1.Arm 2.Disarm 3.Test Button 1: Arm You should operate the remote control unit within 100 meters, transmission range, to activation the system. Once the button pressed, the console will sound continuous two beeps, and system enter armed mode after 1 minute. Button 2: Disarm You should operate the remote control unit within 100 meters, transmission range, to release the system. Once the button pressed, the console will sound a long beep, and system enter disarmed mode. Button 3: Testing You should operate the remote control unit within 100 meters, transmission range, to release the system. Once the button pressed, the console will sound 7 G90 GSM & MMS alarm manual beep a twice, and system enter disarmed mode. If press and hold the button for 3 seconds, system will enter or exit factory testing mode. In testing mode, the system will beep one time when receive the sms, and will beep twice when send the mms. 2、2、2 Enrollment If you are not able to operate the remote control unit(s) normally after System resetting or adding new one(s), you need to re-enroll the remote control unit (s) to system. Instruction is shown as follows. (1) Connect the input Power to the system. (2) After two beeps, press any button within 15 seconds. You will hear one beep to indicate that it is successful. It can match 10 controls at most. (3) If the remote control lost or you want to one of them to be disabled. You can reset the controllers. Sending sms password+C to the system and follow the ways of (2). (4) Note: We suggest that the users disarm the system when the system is off. Because if it is armed, the system will detect the users and alarm immediately when power on the alarm. 2、3 Extension units operations You can install 9 extension units within 100 meters of the main unit. The extension units can be wireless smoke detectors and wireless door/window sensor. It will send sms to the user when it alarms. The users should match the extension units to the main unit first. After power on the main unit and heard two beeps, power on the wireless detectors and trigger it within 15 seconds. A beep from the main unit indicates that it matches successfully. 3、Important notice 3、1 SMS setting (1) Administrator does not need password to program and operate the system, while password is necessary for other user(s) to perform. (2) When the SMS content edited in English, it is within 140 bytes. In Chinese, within 70 words (including figure, letter and other signs), or it will make 8 G90 GSM & MMS alarm manual settings false. (3) It doesn’t matter whether the letter in the SMS command is capital or not. (4) Password is 6 digits from 0-9. (5) Receivers for phone are 6 and 3 for E-mail at most. (6) When program several phone numbers and E-mail at the same time, there must be a space or, or * between them. (Make sure that all these be input in English) (7) User can set several functions at the same time and also can set the system one by one. (8) The E-mail address must be English letters, digits or underline. With an interval sign can program others after the mail address. The users can set at most 3 mail box. The new mailbox will replace the former mail programmed before. If you program more than one mailbox, programming them at the same time. 3、2 MMS Access Method ( 1) Follow the below stated sms format in order to make the system work in different countries. ( 2) Short message form: Password g Homepage(PORT),IP address,APN,( IP Port),(User Name),(Password), Be careful that: Content in bracket is default number, ,it is ignorable if not have. The ‘,’can not be ignored. eg: The Establish content of short message for New World of HONG KANG: 000000ghttp://mmsc.nwmobility.com:8002/,192.168.111.1,mms,9201,,, The short massage content reference to parameters provided by telecommunic- ation company. The parameters maybe different in different country and different area,it depend on the telecommunication company corresponding to the SIM card in it. New World Operator New World Access Point (APN) mms Homepage http://mmsc.nwmobility.com:8002 IP address 192.168.111.1 Login name \ Password \ IP Port 9201 9 G90 GSM & MMS alarm manual (3) Explain of the short message: 1: “000000” is the default password of host monitor; 2: “g” is command character 3: “http://mmsc.nwmobility.com:8002/” is the Homepage, some times call the MMSC URL “8002” as the http port, when the port is “80”, it can be ignored. 4: “192.168.111.1” is IP address, Gateway IP address. 5: “mms” is APN, APN is abbreviate of Access point name 6: If the port is “9201”,it can be ignored, but the’,’ followed can not be ignored. So the short massage above can also be written as: 000000ghttp://mmsc.nwmobility.com:8002/,192.168.111.1,mms,,,, 7: User Name and Password can be ignored if not have, but the’, ’followed cannot be ignored. 4、Port 4、1 Port Power: 12V power supply Center positive GSM Antenna Antenna: Remote antenna SIM Card: SIM socket 10 G90 GSM & MMS alarm manual ISP: Program updating port Vide o1-Video 04 LED1: Power LED indicate light LED2: GSM network Light COM1 definition: 1, 2:Mic. Input connection 3, 4: Flash light driver connection,2 positive,3 negative( Alarm light connection) 5, 6: Siren connection, 5 positive,6 negative 7, 8: Backup battery connection,7 positive,8 negative COM2 definition: 1:12V power 2: Negative CH1 3: PIR input 4: PIR input 5:12V Power 6: Negative CH2 7: PIR input 8: PIR input 9:12V Power 10: Negative 11: PIR input 12: PIR input 13:12V Power 14: Negative 15: PIR input 16: PIR input CH3 CH4 4、2 Port parameter 4.2.1 Main parameter Power: 12V/DC, 1A Backup battery: 12V, 3.5A plumbic acid battery Standby current: 40mA (without including extension units) Max work current: 0.35A (By average, without including flash and siren) Video signal requirements: Input CVBS (complex video signals, support PAL, NTSC) IR requirements: 12V DC Output form: dry contact, N.C Smoke detector: Voltage: 12V/ DC Output form: Dry contact ,N.C Flash light: Voltage: 12V/DC 11 G90 GSM & MMS alarm manual Siren: Voltage: 12V/DC 12