Download User Manual

Transcript
Purpose:
Collecting particles on filter
Where:
Nuclear power plants, under ground mines, in emergency
situations etc. where fast responce and independent operations
are needed.
Portable battery operated sampler from SENYA Oy
SENYA
FINLAND
LILLIPUT
EASY TO CARRY on
GENERAL SPECIFICATIONS FOR SENYA Oy LILLIPUT SAMPLER
SIZE
WEIGHT
MATERIAL
FILTERS
300 x 175 x 165mm ( l x h x w )
approx. 10kg
Anodized aluminum
Ø110mm, Ø100mm, standard filters
System STUK Ø77mm laminated filters
With adapter Ø47mm filters
With adapter activated carbon filters
Battery status indicator, 3-colour LED
Automatic switch OFF when battery power too low
Timer function NOT yet available
Sampler can be run from 230V/50Hz electrical net with Battery Charger
if Battery Pack is low:
HOWEVER BATTERY PACK MUST BE IN NORMAL POSITION IN NET RUNNING.
VOLUME FLOW
CONTROLS
DISPLAY
(Ø90 active area )
Ø110, Ø100mm glass fiber 12m3/h
STUK Ø77mm
10m3/h
9m3/h
7m3/h
Battery duration
approx. 1,5h
“
1,5h
“
2,5h
“
4h
3-stage flow speed control
Pressure difference
Airflow
Cumulative volume
Cumulative time
Pascal
m3/h
m3
hh:mm:ss
MEASURING PRINCIPLE
Pressure difference over orifice, no moving parts
DATA STORAGE
POWER SUPPLY
BATTERY CHARGER
ACCESSORIES
Cumulative volume,
Cumulative time,
One sampling
One sampling
24VDC, 2 x 12V/7Ah closed lead acid batteries in series
Max current used 4,5A
24VDC, 5A, 3-step charger with 3-colour LED indicators
Tripod
Carrying belt
Delivery case
0 I
A2
A3
A4
M1
M2
Conf
1
0/R
HOW TO USE
1. Insert filter laminate into sampling head.
2.PUSH to I to connect POWER
3.Check different display readings by PUSHING .
- you can see how signal lights change A1, A2, A3, A4.
4.RESET panel meter memory by PUSHING RESET.
- you can see that values in A3 ( Total volume ) and
A4 ( Total time ) has changed to 00.00.00.
5.TURN FLOW CONTROL CW and stop turning when you
have got desired flow rate, see A2.
6.When you have collected your sample, depending whether
on desired volume, m3 or desired time, hours/minutes
- TURN potentiometer CCW all the way to the left.
Pump stops and also your panel meter stops.
Panel meter starts calculations when Pascal value is higher than
50Pa and it pauses calculations when value is lower than 50Pa.
13.10.88
A1
5.PANEL METER display
A1, Pressure difference,Pascal
A2, Volume flow,m3/h
A3, Total volume,m3
A4, Total time,hh:mm:ss
3.CHARGE CONNECTOR
- When batteries are empty,
charge
4.STOP / FLOW CONTROL
- Changes pump speed
1.POWER
- Connects batteries to unit
2.RESET
- Resets panel meter memory
1
3
2
4
BATTERY INDICATOR
Battery fully charged
Battery half charged
Battery is empty
3
If battery goes empty
during sampling, the
pump will automatically
stop.
To RESET this you have
to turn FLOW CONTROL
to 0/R.
2
HOW-TO-USE LILLIPUT
1.
Charge battery by connecting charger to
connector.
When 3-step charger light has turned to greeen
then battery is full.
When not in use keep battery fully loaded.
2
A1
A3
A4
M1
M2
13.10.88
3
1
A2
Conf
1
0/R
0 I
1.POWER
- Connects batteries to unit
2.RESET
- Resets panel meter memory
3.CHARGE CONNECTOR
- When batteries are empty,
charge
4.STOP / FLOW CONTROL
- Changes pump speed
5.PANEL METER display
A1, Pressure difference,Pascal
A2, Volume flow,m3/h
A3, Total volume,m3
A4, Total time,hh:mm:ss
HOW TO USE
1. Insert filter laminate into sampling head.
2.PUSH to I to connect POWER
3.Check different display readings by PUSHING .
- you can see how signal lights change A1, A2, A3, A4.
4.RESET panel meter memory by PUSHING RESET.
- you can see that values in A3 ( Total volume ) and
A4 ( Total time ) has changed to 00.00.00.
5.TURN FLOW CONTROL CW and stop turning when you
have got desired flow rate, see A2.
6.When you have collected your sample, depending whether
on desired volume, m3 or desired time, hours/minutes
- TURN potentiometer CCW all the way to the left.
Pump stops and also your panel meter stops.
Panel meter starts calculations when Pascal value is higher than
50Pa and it pauses calculations when value is lower than 50Pa.
2
3
4
BATTERY INDICATOR
Battery fully charged
Battery half charged
Battery is empty
If battery goes empty
during sampling, the
pump will automatically
stop.
To RESET this you have
to turn FLOW CONTROL
to 0/R.
2.
Open filter cover
Insert filter into sampling head.
you can use Ø100mm round filters
or you can use filter laminates.
Close filter cover.
You can:
Use LILLIPUT laminated
filters:
- max diameter Ø90mm
- min diameter Ø47mm
Use standard round filters:
- max diameter Ø110mm
-min diameter Ø100mm
Use with adapter:
- Ø47mm filters
- carbon cartridges
- .....
Adpter for Ø47mm geometry consist of similar base plate as normal
filter plate.
It has a adapter part where you can fit Ø47mm activated carbon cartiridges;
this adapter is based on HI-Q company elements and fits their cartridges.
In the same adapter there is also a place for Ø47 particle filters.
CODING OF SIGNAL LIGHTS IN PANEL METER
A1= Pressure difference on orifice:
Pascal
A1
A2
A3
A4
M1
M2
Conf
850
Pascal
A2= Air flow in: m3 / h
A1
A2
A3
A4
A1
A2
A3
A4
M1
M2
Conf
M1
M2
Conf
9,5
m3/h
A3= Total air volume in: m3
8,8
m3
A4= Total time in: hh:mm:ss
Move on by pressing downward
arrow. You can also move by
upward arrow.
This can be done also during
sampling.
hh:mm:ss
A1
A2
A3
A4
M1
M2
Conf
10:26
FLOW SPEED CONTROL
A1
A2
A3
A4
M1
M2
13.10.88
Conf
1
2
3
0/R
0 I
4
BATTERY INDICATOR
Battery fully charged
Battery half charged
Battery is empty
If battery goes too low
during sampling, the
pump will automatically
stop.
To RESET this you have
to turn FLOW CONTROL
to 0/R.
F rev.
C rev.
E rev.
B rev.
D rev.
A rev.
2
3
BATTERY
MALE PLUG
CON2
F2
6A
17
PRESS1
2
3
19
20
21
7
8
9
1
23
SLOT A
2000SEN-I/O-24V
SUPPLY
S1
22
2
24VDC
24
A
1 2 3 4
B
5 6 7 8
25
SENYA OY
schematics
SLOT B
26
28
RESET S1
27
3
1
29
Plan.
30
32
RED
GRN/GRAY
BLACK
Circuit
23042006
9
8
6
7
5
4
2
3
1
31
34
35
36
02.05.2011 jle
VACUUM PUMP
M
-
Older: 3=pink
5=Yellow
33
37
O
N
M
L
K
J
H
G
F
E
D
C
B
A
S
Check
Draw.
Sheet
1 / 1
Drawing no.
Project
Lilliputti V2
Centre
S
R
DPT1000-R4-AZ
1
18
0
R
SUPPLY/RECHARGE
FEMALE JACK
1
GND
16
YLW
P
CON1
+24VDC
MAIN SWITCH
F1
6A
15
RED
P
O
N
M
L
K
J
H
G
F
E
D
C
B
A
14
4-20mA
13
RED
YLW
RED
12
RED
BLCK
YLW
GND
3
GRN
YLW
GRN
BLE
1
2
3
4
5
6
GRY
WHT
11
YLW
1
2
3
4
5
6
BLACK
23.4.2006
Kuva1
PCB
ATTENTION! IF BATTERY PACK IS SWOLLEN, CHANGE
IT IMMEDIATELY.
EQUIPMENT SELF PROTECTION
Fuse 1.
Fuse 2.
1.
2.
3.
4.
AUTOMATIC FUSE, cuts OFF charging in over current situation:
- check what caused over current; possible cause -broken battery
AUTOMATIC FUSE, cuts OFF if too much current is drawn from battery
- check wha caused over current; possible cause short circuit in electronics
Automatic cut OFF if pump warms too much, let pump cool
- intake may be fully blocked, example too filled filter.
If battery voltage drops under 20,3V pump is cut OFF; load battery.
STUK77
Pascal
176
540
694
LILLIPUT TESTING
Date:05.04.2011
Serial nr:STUK2011-001
Person: M. Terho
47glass fiber
47glass/carbon
m3/h
Pascal
m3/h
Pascal
m3/h
6.2
40
3
32
2.7
10.7
151
5.8
119
5.1
12
169
6.1
130
5.4
STUK77
m3/h
6.2
10.7
12
47glass fiber 47glass/carbon
m3/h
m3/h
3
2.7
5.8
5.1
6.1
5.4
LILLIPUT STUK2011-001
14
12
m3/h
10
STUK77
47glass
47glass/carbon
8
6
4
2
0
1
2
3
Tehoasetus
LILLIPUT STUK2011-001
14
12
m3/h
10
Series1
47glass
47glass/carbon
8
6
4
2
0
0
200
400
Pascal
600
800
LILLIPUT
Use LILLIPUT
- outdoors, but not in heavy rain
- on heavy duty tripod
- or use shoulder carrying belt
- or on some level surface
Operation interface is simple
and easy to use:
You can:
Use LILLIPUT laminated
filters:
- max diameter Ø90mm
- min diameter Ø47mm
EASY TO CARRY on
Use standard round filters:
- max diameter Ø110mm
-min diameter Ø100mm
Purpose:
Where:
Collecting particles on filter
Nuclear power plants, under ground mines, in emergency
situations etc. where fast responce and independent operations
are needed.
Portable battery operated sampler from SENYA
SENYA
FINLAND
Use with adapter:
- Ø47mm filters
- carbon cartridges
- .....