Download T-2S240-2S350-2S500_Manual - ITC Audio

Transcript
PUBLIC ADDRESS SYSTEM
OPERATION MANUAL
T-2S60
2-CHANNEL AMPLIFIER
T-2S60
SIGNAL CLIP PROT TEMP
POWER
CH2
CH 1
VOLUME
CH 2
VOLUME
4
5
4
7
T-2S120
2-CHANNEL AMPLIFIER
SIGNAL CLIP PROT TEMP
CH2
CH 1
VOLUME
CH 2
VOLUME
4
5
6
4
7
9
1
6
7
8
2
9
1
10
0
5
3
8
2
T-2S240
2-CHANNEL AMPLIFIER
8
9
10
0
CH1
3
ON
OFF
7
1
10
SIGNAL CLIP PROT TEMP
POWER
6
2
9
1
5
3
8
2
0
T-2S120
6
3
ON
OFF
SIGNAL CLIP PROT TEMP
CH1
10
0
SIGNAL CLIP PROT TEMP
SIGNAL CLIP PROT TEMP
CH1
CH2
POWER
CH 2
VOLUME
CH 1
VOLUME
4
T-2S240
5
6
3
ON
4
7
2
OFF
1
T-2S350
2-CHANNEL AMPLIFIER
6
7
2
9
0
5
3
8
8
1
10
9
0
SIGNAL CLIP PROT TEMP
10
SIGNAL CLIP PROT TEMP
CH1
CH2
POWER
T-2S350
CH 2
VOLUME
CH 1
VOLUME
4
5
6
3
ON
4
7
2
OFF
1
T-2S500
2-CHANNEL AMPLIFIER
6
7
2
9
0
5
3
8
8
1
10
9
0
SIGNAL CLIP PROT TEMP
10
SIGNAL CLIP PROT TEMP
CH1
CH2
POWER
T-2S500
CH 2
VOLUME
CH 1
VOLUME
4
OFF
5
6
3
ON
4
7
2
1
9
0
10
5
6
3
8
7
2
8
1
9
0
10
2-CHANNEL AMPLIFIER
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS .......................................................................................3
2. GENERAL DESCRIPTION ....................................................................................5
3. FEATURES .............................................................................................................. 5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel(2U) ...................................................................................................... 6
4.2 Rear Panel(2U).................................................................................................... ...7
4.3 Front Panel(3U)....................................................................................................... 8
4.4 Rear Panel(3U).......................................................................................................9
4.5 Rear Panel(3U)......................................................................................................10
5. CONNECTIONS...................................................................................................... 11
6. MACHINE OPERATION ....................................................................................... 12
7. APPLICATIONS .....................................................................................................13
8. BLOCK DIAGRAM ..................................................................................................15
9. SPECIFICATIONS ................................................................................................16
10.DIMENSIONAL DIAGRAM .................................................................................18
2
1. SAFETY PRECAUTIONS
Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When the Unit is in Use
When Installing the Unit
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest ITC dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest ITC dealer.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
3
SAFETY PRECAUTIONS
When the Unit is in Use
When Installing the Unit
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your ITC dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
Due to product upgrades, while some of the features and specification in the user manual does not
match the actual functions, sorry for any inconvenience and thanks for your kind understanding!
4
2. GENERAL DESCRIPTION
With two separate power amplififers in a single chassis and power ratings from 60 to 500
watts RMS, these sleek, attractive units provide a compact solution for ITC system
amplification and distribution.Both balanced and unbalanced line inputs make it selectable
for installer, balanced line output feeds to another power amplifier as well as secures the
signal transmission is less noise and longer distance. 70V, 100V and 4ohm speaker outputs
are convenient for installation when selection different speaker matching. A master volume
control is included. Complete protection includes clip, short circuit, high temp and overload.
Indications for power, signal, clip, protection and temp.
3. FEATURES
1. Rated outputs : 60W to 500W.
2. 100V/70V line transformer-isolated speaker outputs, low impedance 4 ohms speaker outputs.
3. 2 independent amps in a singale chassis.
4. LED status indicators.
5. Volumre controls for each channel.
6. Short-circuit, clipping and high-temp protection.
5
4. NOMENCLATURE AND FUNCTIONS
4.1 FRONT PANEL(2U)
7
6 5 4
3
6 5 4
SIGNAL CLIP PROT TEMP
SIGNAL CLIP PROT TEMP
CH2
CH1
CH 1
VOLUME
POWER
4
5
OFF
CH 2
VOLUME
6
4
7
3
ON
1
6
7
8
2
9
1
5
3
8
2
0
3
9
1
10
0
10
2
1. POWER SWITCH
On top of the opening Power Press the end, power shut down
2. CH1\CH2 VOLUME
volume control
3. TEMP (CH1\CH2)
Device when the internal temperature is too high, the indicator light and disconnect the
output protection device. When the device internal temperature drops to a safe temperature (90 degrees) the following is to lift the protection, the device starts normal operation
4. PROT (CH1\CH2)
Equipment, normal working hours, lights out, when the output connection overload (more than 1.6 times
the rated output power) will disconnect the output protection device
5. CLIP (CH1\CH2)
Clip lit when max wattage output & output signal distortion.
6. SIGNAL (CH1\CH2)
Signal indicator When lit input signal is detected.
7. POWER
Power indicator
6
NOMENCLATURE AND FUNCTIONS
4.2 REAR PANEL(2U)
16
INPUTS
2
CH 2 INPUTS
CH 2 LINK
CH 1 INPUTS
CH 1 LINK
1
3
4
70V
OUTPUTS 1
¦¸
100V
4
70V
100V
COM
OUTPUTS 2
COM
GND
LIFT
LINK
XLR BAL
1-GND
2-HOT+
3-COLD-
¦¸
2
1
3
8
9
10
11
12
13
14
15
8. ~220-240V 50/60Hz POWER INPUT
9. OUTPUTS2
Connectors for 4 ohms or 70V and 100V
speaker
10. OUTPUTS1
Connectors for 4 ohms or 70V and 100V
speaker
11. LINE INPUT (XLR)
Music signal input balance
12. LINE INPUT (6.35TRS)
Balanced or unbalanced input music signal (unbalanced input, use of non-equilibrium
6.35TRS jack)
13. LINK OUTPUT (6.35TRS)
Balanced or unbalanced output music signal (unbalanced output, use of non-equilibrium
6.35TRS jack)
14. LINE CASCADE OUTPUT (CORLEONE SOCKET)
XLR, output signal of power amplifier
15. COOLING FANS
16. GROUND LIFTER
Earth line ground or lift switch. Enable the switch to "GND" position when one unit is used,
disable the switch "LIFT" when several units are used to avoid noise caused by several earth
line grounded.
7
NOMENCLATURE AND FUNCTIONS
4.3 FRONT PANEL(3U)
7
6 5 4
3
6 5 4
SIGNAL CLIP PROT TEMP
3
SIGNAL CLIP PROT TEMP
CH1
CH2
POWER
CH 2
VOLUME
CH 1
VOLUME
4
5
3
ON
1
4.
5.
6.
7.
7
8
1
9
0
6
2
8
1
5
3
7
2
OFF
1. POWER SWITCH
On top of the opening Power
2. CH1\CH2 VOLUME
Channel volume control
3. TEMP (CH1\CH2)
4
6
9
0
10
10
2
Press the end, power shut down
The protection indicator will be light on when the inside temperature is over 90 , the output will be
cut to protect the amplifier from damage. It will resume to work after cooling down
PROT (CH1\CH2)
The protection indicator will be light on when the constant output is 160% higher than the rated
output, the output will be cut to protection the amplifier from damage. This indicator will be extinguished when amplifier is under normal working conditions.
CLIP (CH1\CH2)
Clip lit when max wattage output & output signal distortion.
SIGNAL (CH1\CH2)
Signal indicator LED When lit input signal is detected.
POWER
Power indicator LED
8
NOMENCLATURE AND FUNCTIONS
4.4 REAR PANEL(3U)
16
GND
INPUTS
LINK
XLR BAL
1-GND
2-HOT+
3-COLD-
2
CH 2 INPUTS
CH 2 LINK
CH 1 INPUTS
CH 1 LINK
1
3
4
70V
OUTPUTS 1
¦¸
100V
4
70V
100V
COM
OUTPUTS 2
COM
LIFT
¦¸
2
1
3
8
9
10
11
12
13
14
15
8. ~220-240V 50/60Hz POWER INPUT
9. OUTPUTS2
Connectors for 4 ohms or 70V and 100V
speaker
10. OUTPUTS1
Connectors for 4 ohms or 70V and 100V
speaker
11. LINE INPUT (XLR)
Music signal input balance
12. LINE INPUT (6.35TRS)
Balanced or unbalanced input music signal (unbalanced input, use of non-equilibrium
6.35TRS jack)
13. LINK OUTPUT (6.35TRS)
Balanced or unbalanced output music signal (unbalanced output, use of non-equilibrium
6.35TRS jack)
14. LINE CASCADE OUTPUT (CORLEONE SOCKET)
XLR, output signal of power amplifier
15. COOLING FANS
16. GROUND LIFTER
Earth line ground or lift switch. Enable the switch to "GND" position when one unit is used,
disable the switch "LIFT" when several units are used to avoid noise caused by several earth
line grounded.
9
NOMENCLATURE AND FUNCTIONS
4.5 REAR PANEL(3U)
16
GND
INPUTS
LINK
XLR BAL
1-GND
2-HOT+
3-COLD-
2
CH 2 INPUTS
CH 2 LINK
CH 1 INPUTS
CH 1 LINK
1
3
4
70V
OUTPUTS 1
¦¸
100V
4
70V
100V
COM
OUTPUTS 2
COM
LIFT
¦¸
2
1
3
8
9
10
11
12
13
14
15
8. ~220-240V 50/60Hz POWER INPUT
9. OUTPUTS2
Connectors for 4 ohms or 70V and 100V
speaker
10. OUTPUTS1
Connectors for 4 ohms or 70V and 100V
speaker
11. LINE INPUT (XLR)
Music signal input balance
12. LINE INPUT (6.35TRS)
Balanced or unbalanced input music signal (unbalanced input, use of non-equilibrium
6.35TRS jack)
13. LINK OUTPUT (6.35TRS)
Balanced or unbalanced output music signal (unbalanced output, use of non-equilibrium
6.35TRS jack)
14. LINE CASCADE OUTPUT (CORLEONE SOCKET)
XLR, output signal of power amplifier
15. COOLING FANS
16. GROUND LIFTER
Earth line ground or lift switch. Enable the switch to "GND" position when one unit is used,
disable the switch "LIFT" when several units are used to avoid noise caused by several earth
line grounded.
10
5. CONNECTIONS
SPEAKER CONNECTIONS
COM
4
70V
100V
COM
70V
4
100V
81
41
20
4
(T-2S60)
(T-2S120) 14
(T-2S240) 9.8
(T-2S350)
(T-2S500)
(T-2S60)
(T-2S120) 28
(T-2S240) 20
(T-2S350)
(T-2S500)
70V LINE
COM
4
70V
100V
166
83
42
100V LINE
70V/
11
6. MACHINE OPERATION
MIC INPUT CHANNEL 1~3
This is a special connector which will accept 3-conductor XLR.
These inputs are suitable to receive signal from microphones level devices.
MIC JACK (XLR JACK)
LINE JACK (TRS PHONE JACK)
Pin 1:GROUND
Sleeve:GROUND
Pin 2:HOT(+)
Tip:HOT(+)
Pin 3:COLD(-)
Ring:COLD(-)
1.GROUND
2
3
1
1
2.HOT
3
2
3.COLD
CH1/CH2 INPUTS
COLD
1.GROUND
2.HOT
3.COLD
GROUND
HOT
CH1/CH2 LINKS
3
1
2
3
2
1
CH1/CH2 LINKS
CH1/CH2 INPUTS
OPERATION ATTENTION
= It indicate signal distortion when the panel's
= Do not open and close the machine frequently.
Reopen should be after 10 seconds
CLIP LED is lighting red and it may caused
by:
1. If there is excess signal input, the power
= Power supply should match up to the machine.
= The machine outfit with ground line, so please
plug on the connected-ground wire-net
LED will light,in this case,please turn signal
to the minimum.
= As formidable shock or impact on machine such
as (thunder shock, halfway signal pause,excess
2. There is overload output if the LED is not
ligh-ting, please check the input circuit.
rated signal input or other interference), the ma
= When you start the machine, it will run into
-chine will auto-check and reopen automatically.
auto-checking condition, its protection LED
= Please switch off the switch till there is no noise
(yellow) will shine 3 seconds.If the protection
if there is a badly power abnormality or interfe-
time is too long, please check the machine or
rence.
contact with our distribution of your local
= Contact with our local distributions if machine
is failure to work.
place.
12
INSIDE AC/DC
FUSE 220VAC
DC POWER
24V MAX 0.6A
2--OUTPUTS--1
REC
LINE 10
LINE 9
LINE 8
LINE 7
LE
FT
LIFT
GND
10
9
8
2
3
1
OUTPUTS 2
MIC INPUTS
4
LINK
70V
INPUTS
COM
1
3
2
OUTPUTS 1
¦¸
LINK
SERIAL NO:
3
2
GND
PRIORITY
CHIME
LED PWR
7
6
1
3 1
524
2
3
MIC INPUT
2
2
3
3
CHIME
REMOTE
P.T.T 1
4
5
6
7
13
DC POWER
24V MAX 0.6A
2--OUTPUTS--1
INPUTS
CH 1 INPUTS
CH 2 INPUTS
INSIDE AC/DC
FUSE 220VAC
230V/50Hz
MAX 9.9W
1
1
AMPLIFIER
MODEL NO: T-2S01
4
MIC/LINE INPUTS
PRE AMPLIFIER
5
XLR BAL
1-GND
2-HOT+
3-COLD-
PUBLIC ADDRESS S YSTEM
6
1
OUTPUTS
INPUTS
¦¸
7
XLR BAL
1-GND
2-HOT+
3-COLD
4
3
70V
2
COM
INPUTS
100V
HT
RIG
100V
POWER AMPLIFIER
REC
LINE 10
LINE 9
LINK
LINE 8
LINE 7
CH 1 LINK
CH 2 LINK
10
9
MIC INPUTS
8
2
3
1
2
3
1
7
INPUTS
1
3
2
OUTPUTS
PUBLIC ADDRESS S YSTEM
6
XLR BAL
1-GND
2-HOT+
3-COLD
4
SERIAL NO:
3
2
GND
PRIORITY
CHIME
LED PWR
7
6
1
3 1
524
2
3
MIC INPUT
CHIME
REMOTE
P.T.T 1
4
5
6
7
AMPLIFIER
MIC/LINE INPUTS
PRE AMPLIFIER
5
POWER AMPLIFIER
7. APPLICATIONS
REAR PANEL CONNECTIONS
LE
FT
INSIDE AC/DC
FUSE 220VAC
DC POWER
24V MAX 0.6A
LINE 10
LINE 9
LINE 8
LINE 7
LE
FT
LIFT
GND
INPUTS
9
MIC INPUTS
OUTPUTS 2
10
4
REC
70V
2--OUTPUTS--1
¦¸
8
2
1
3
1
1
3
2
OUTPUTS
LINK
6
XLR BAL
1-GND
2-HOT+
3-COLD
OUTPUTS 1
XLR BAL
1-GND
2-HOT+
3-COLD-
3
2
7
4
LINK
COM
INPUTS
70V
INPUTS
COM
14
¦¸
100V
HT
RIG
100V
5
4
MIC/LINE INPUTS
2
2
3
3
1
1
3
4
5
6
7
7
6
1
3 1
524
2
3
MIC INPUT
CHIME
REMOTE
P.T.T 1
INSIDE AC/DC
FUSE 220VAC
230V/50Hz
MAX 9.9W
CH 1 INPUTS
CH 2 INPUTS
2
GND
PRIORITY
CHIME
LED PWR
AMPLIFIER
POWER AMPLIFIER
DC POWER
24V MAX 0.6A
2--OUTPUTS--1
INPUTS
CH 1 LINK
CH 2 LINK
REC
LINE 10
LINE 9
LINK
LINE 8
LINE 7
10
9
MIC INPUTS
8
2
3
1
2
3
1
7
INPUTS
1
3
2
OUTPUTS
PUBLIC ADDRESS S YSTEM
6
XLR BAL
1-GND
2-HOT+
3-COLD
4
3
2
GND
PRIORITY
CHIME
LED PWR
7
6
1
3 1
524
2
3
MIC INPUT
CHIME
REMOTE
P.T.T 1
4
5
6
7
AMPLIFIER
MIC/LINE INPUTS
PRE AMPLIFIER
5
POWER AMPLIFIER
APPLICATIONS
REAR PANEL CONNECTIONS
LE
FT
CH1 INPUTS
CH1 LINK
CH2 INPUTS
CH2 LINK
EB
EB
15
Z
POWER
PA
PA
PT
TO
TO
~220-240V 50/60Hz
COM
4
70V
100V
COM
4
100V
70V
8. BLOCK DIAGRAM
9. SPECIFICATIONS
MODEL
T-2S60
T-2S120
T-2S240
RATED POWER OUTPUT
2X60W
2X120W
2X240W
SPEAKER OUTPUTS
4
,70V/100V
INPUT SENSITIVITY
775mV/0dB
FREQUENCY RESPONSE
50Hz~15KHz +
-3dB
S/N RATIO
>90dB
T.H.D
<1%
Compulsive wind cooling
RADIATOR METHOD
INDICATORS
Power, Signal, Protection and Overheat
PROTECTION
Power,Overheat, Overload and short-circuit
POWER REQUIREMENTS
POWER CONSUMPTION
~220-240V 50/60Hz
200W
400W
484X358X88
DIMENSION(mm)
720W
484X359X132
NET WEIGHT
11.3Kg
14.3Kg
24.3Kg
GROSS WEIGHT
12.5Kg
16.5Kg
26.5Kg
16
SPECIFICATIONS
MODEL
T-2S350
T-2S500
RATED POWER OUTPUT
2X350W
2X500W
SPEAKER OUTPUTS
4
,70V/100V
INPUT SENSITIVITY
775mV/0dB
FREQUENCY RESPONSE
50Hz~15KHz +
-3dB
S/N RATIO
>90dB
T.H.D
<1%
Compulsive wind cooling
RADIATOR METHOD
INDICATORS
Power, Signal, Protection and Overheat
PROTECTION
Power,Overheat, Overload and short-circuit
POWER REQUIREMENTS
POWER CONSUMPTION
~220-240V 50/60Hz
1000W
1500W
484X359X132
DIMENSION(mm)
NET WEIGHT
22.5Kg
24.3Kg
GROSS WEIGHT
23.4Kg
26.5Kg
17
10. DIMENSIONAL DIAGRAM
UNIT :mm
484
CH2
CH 1
VOLUME
CH 2
VOLUME
4
5
6
7
1
9
6
7
3
8
8
2
9
1
10
0
5
4
3
2
94
POWER
ON
OFF
SIGNAL CLIP PROT TEMP
CH1
88
SIGNAL CLIP PROT TEMP
10
0
436
INPUTS
CH 2 INPUTS
CH 2 LINK
CH 1 INPUTS
CH 1 LINK
1
3
84
¦¸
2
4
70V
COM
OUTPUTS 1
100V
4
70V
COM
OUTPUTS 2
100V
LIFT
LINK
XLR BAL
1-GND
2-HOT+
3-COLD-
GND
¦¸
2
1
3
322
84
316
6
UNIT :mm
SIGNAL CLIP PROT TEMP
CH2
CH1
CH 1
CH 2
VOLUME
5
4
6
0
10
VOLUME
5
7
3
ON
OFF
Over 100
SIGNAL CLIP PROT TEMP
POWER
9
1
Over 100
6
0
10
7
3
8
2
4
8
2
9
1
Over 100
18
DIMENSIONAL DIAGRAM
UNIT:mm
484
SIGNAL CLIP PROT TEMP
SIGNAL CLIP PROT TEMP
CH1
CH2
CH 2
VOLUME
CH 1
VOLUME
5
4
7
2
8
1
6
3
7
2
8
1
9
0
5
4
6
3
ON
OFF
138
132
POWER
9
0
10
10
GND
INPUTS
LINK
XLR BAL
1-GND
2-HOT+
3-COLD-
¦¸
CH 2 INPUTS
CH 2 LINK
CH 1 INPUTS
CH 1 LINK
1
3
4
70V
OUTPUTS 1
COM
4
70V
COM
100V
OUTPUTS 2
2
100V
LIFT
128
436
¦¸
2
1
3
423
417
128
25
6
SIGNAL CLIP PROT TEMP
Over 100
UNIT:mm
SIGNAL CLIP PROT TEMP
CH1
CH2
POWER
CH 2
VOLUME
CH 1
VOLUME
4
ON
OFF
5
4
6
3
7
1
9
2
0
5
6
3
8
10
Over 100
7
2
8
1
9
0
10
Over 100
19
PUBLIC ADDRESS SYSTEM
PUBLIC ADDRESS SYSTEM
VersionV0.4