Download USER MANUAL - Helios Hud

Transcript
USER MANUAL
for
PROFESSIONAL POWER AMPLIFIERS:
A500 • A700v • A750 • A1000 • A1004 • A1500 • A2000 • A3000 • A4000
A5000 • A5003 • A6000 • Q6 • Q900 • Q1004 • QB1000/600 • Line250 • Line500
CONTENTS
Installation.................................................. 2
Box contents, positioning & power................ 2
Inputs ........................................................... 3
Outputs ........................................................ 4
Speaker power ratings .................................. 5
Speaker impedances ..................................... 5
Mono bridge mode....................................... 6
Bridge input & output wiring ........................ 6
Operation ................................................... 7
Protection systems ........................................ 7
Servicing ....................................................... 7
Front & rear panels ....................................... 8
Specifications.............................................. 14
Warranty & mono bridge loadings .............. 16
Installation
Box contents
In addition to your amplifier and this manual, the carton should contain the following items:
• Neutrik® Speakon® plugs, depending on your amplifier model:
• Line250, Line500
no Speakon plugs
• A700v:
one Speakon plug
• Q6, Q1004, QB1000/600, Q900:
four Speakon plugs
• All other models:
two Speakon plugs
• A500 and A700v only. Detachable power cable with IEC connector.
• Warranty card. Please complete this card and return it to Chevin Research. Failure to
register may result in delays if you require warranty service. See rear cover for warranty.
Positioning
• Your amplifier must have good ventilation. Air is drawn in at the rear panel and is expelled
at the front. It is vital to keep front and rear of unit free from obstruction.
• Your amplifier may be used free-standing or installed in a 19” rack. If installed in a rack,
the rear of the chassis should be supported. Rear rack-mount supports are integral on all
models except the A500 & A700v.
Power
Wiring
• EARTHING: All Chevin amplifiers must be earthed.
• A500 & A700v models connect to the mains supply via a supplied detachable power cable.
• All other models have fixed power cables, colour coded to European standards:
Green/Yellow = Earth Blue=Neutral Brown= Live
• The A5000, A6000 and Q900 have 2 power cables.
• The live connector in certain 115V models is coloured RED.
• The amplifier must be connected to a 3-pin grounded outlet via a 3-pin connector of
sufficient voltage and current rating. If the connector has provision for a fuse, a suitable
fuse must be fitted.
Mains supply
• The power rating of the supply should be at least twice the total audio output of the system.
• VOLTAGE SELECTION: Your amplifier is factory set to your local supply voltage and should
be changed only by an authorised Chevin dealer.
• ELECTRIC SHOCK/FIRE HAZARD: The unit must be connected to an adequately rated
grounded outlet. All related cables, connectors and switch gear must be sufficiently rated
to avoid risk of overheating and fire.
2
Power (continued)
Three phase systems
• IMPORTANT: The neutral current will not balance on three-phase systems.
• Use individual neutral connections from each phase outlet back to the distribution point.
• Alternatively, ensure the neutral conductor is of sufficient capacity to handle a return
current equal to the sum total of the current in the three phases.
Inputs
• XLR connectors are used on all amplifier inputs except for Line250 and Line500 models.
• Do not directly connect any channel to more than one signal source, these are not mixing
amplifiers.
• All inputs are electronically balanced and can accept signals from balanced and unbalanced
sources. Maintain the same phase polarity on all equipment in the signal chain.
Inputs from balanced sources
Use shielded cable with XLR connectors at both ends (except Line250 and Line500):
• Ground/screen: Connect cable braid to XLR pin 1.
• HOT (+) signal: XLR pin 2
• COLD (–) signal: XLR pin 3
Inputs from unbalanced sources
Use shielded cable with an XLR connector at the amplifier end (except Line250 and Line500)
and either a jack plug, phono plug or XLR connector, as appropriate:
• Ground/screen and COLD (–): At the source end, connect the COLD signal wire and cable
braid to the sleeve of jack plug or phono connector, or pin 1 of an XLR connector (if used).
• At the source end of the cable, connect the HOT (+) signal to the tip of the jack plug, the
pin of the phono plug or pin 2 of an XLR connector (if used).
• Connect the XLR at the amplifier end as per ‘Inputs from balanced sources’ above.
Inputs to Line250 and Line500 models
The Line250 and Line500 models use block connectors at the rear panel. Use connections at
the source end as explained above for balanced or unbalanced sources. At the amplifier end,
make wire connections rather than using an XLR connector.
Mono bridging
Various models can have their channels bridged together (except A700v, A5000, A6000,
QB1000/600, Line250 or Line500). For details about the necessary wiring, see page 6.
Speakon is a registered trademark of Neutrik AG
XLR is a registered trademark of ITT Cannon Ltd.
3
Outputs
Connections are made to the amplifier load using Neutrik Speakon sockets (except for Line250
and Line500 models). As with input connectors, maintain phase polarity throughout the system.
IMPORTANT: High voltages are present at output terminals during operation and for
a period afterwards. Do not connect the amplifier to any other amplifier output or to
any equipment other than a speaker system.
Take great care to note the wiring specifications particular to your amplifier model:
A700v
One Speakon socket per channel, wired as follows:
1+ = HOT
1– = COLD (not Ground)
2+ = NO CONNECTION
2– = NO CONNECTION
WARNING: The A700v output is permanently connected in bridge mode. Both hot and cold
outputs carry high level signal. Further bridging is impossible. No terminal of the speaker
socket is connected to ground. Do not connect any part of the speaker system to ground.
A500 • A750 • A1000 • A1004 • A1500 • A2000 • A3000 • A4000 • A5003 • Q900
Two parallel-connected Speakon sockets (A500: one socket) per channel, wired as follows:
1+ = HOT
1– = GROUND
2+ = NO CONNECTION
2– = GROUND
A5000 • A6000
Two parallel-connected Speakon sockets per channel, wired as follows:
1+ = HOT
1– = COLD (not Ground)
2+ = NO CONNECTION
2– = COLD (not Ground)
WARNING: The A5000 / A6000 outputs are permanently connected in bridge mode. Both hot and
cold outputs carry high level signal. Further bridging is impossible. Do not connect any part of the
A5000 or A6000 outputs to ground. Take care when using loudspeaker controllers or processors.
Q6 • Q1004
One Speakon socket per channel, parallel connected in channel pairs: A & B, C & D.
Each socket in the pair carries the output of both channels, wired as follows:
Channel A & B sockets:
1+ = HOT A
2+ = HOT B
1– = GROUND
2– = GROUND
Channel C & D sockets:
1+ = HOT C
2+ = HOT D
1– = GROUND
2– = GROUND
QB1000/600
One Speakon socket per channel, parallel connected in pairs: A & B, C & D.
Each socket in the pair carries the output of both channels, wired as follows:
Channel A & B sockets:
1+ = HOT B 1000W 2+ = HOT A 600W
1– = GROUND
2– = GROUND
Channel C & D sockets:
1+ = HOT C 1000W 2+ = HOT D 600W
1– = GROUND
2– = GROUND
Line250 • Line500
Connect load to output connector blocks using the 0v terminal and either the 70v or 100v
HOT terminals, as appropriate to the system.
4
Speaker power ratings
Suggested speaker ratings per amplifier channel, in watts.
Model
16Ω
8Ω
4Ω
2Ω
A500
A700v
A750
A1000 • Q6
A1004 • Q1004
A1500
QB1000/600 A&D
B&C
A2000
A3000
A4000
A5000 • A5003
A6000
Q900
115
450
160
230
400
500
230
400
230
350
450
500
800
350
230
900
300
450
750
1000
450
750
500
650
800
1000
1200
650
460
–
600
900
1500
1900
900
1500
1000
1300
1500
2000
2600
1300
–
–
–
–
–
–
–
–
1800
2300
3000
3600
4500
2300
Speaker impedances
Correct loadings for all models are shown here. Multiple speakers are connected in parallel.
A700v
WARNING: Do not use a system with a total impedance less than 8Ω.
The A700v can be used to drive a 70 volt distribution system (maximum loading 600W) or a
100 volt line system at a reduced output. Note: Do not connect a transformer between the
A700v output and distribution system. Where line transformers are used to match speakers to
the distribution system, adjust to suit the characteristics of the speaker.
A500 • A750 • A1000 • A1004 • A1500 • Q6 • Q1004 • QB1000/600 (per channel)
WARNING: Do not use a system with a total impedance per channel less than 4Ω.
4 or less
speakers of 16Ω
OR
2 or less
speakers of 8Ω
OR
1 speaker
of 4Ω
A2000 • A3000 • A4000 • A5000 • A5003 • A6000 • Q900 (per channel)
WARNING: Do not use a system with a total impedance per channel less than 2Ω.
8 or less
speakers of 16Ω
OR
4 or less
speakers of 8Ω
OR
2 or less
speakers of 4Ω
OR
1 speaker
of 2Ω
Note: The A5000 and A6000 models both incorporate an adjustable output limiting control,
concealed behind the front panel. Consult an authorised Chevin dealer to enable this feature.
5
Mono bridge mode
WARNING: You cannot bridge the A700v, A5000, A6000, QB1000/600, Line250 or Line500.
Inputs
A500
1 Make a lead from the source with two XLR plugs at the amplifier end.
2 HOT output from the source goes to pin 2 of Channel A XLR and pin 3 of Channel B XLR.
3 COLD output from the source goes to pin 3 of Channel A XLR and pin 2 of Channel B XLR.
4 The cable screen goes to pin 1 of both XLR plugs.
Q6 • Q1004
1 Make two leads, one for each source channel. Each lead needs 2 XLR plugs at the amplifier end.
2 In each lead, HOT output from the source goes to pin 2 of the first XLR & pin 3 of the second XLR.
3 In each lead, COLD output from the source goes to pin 3 of first XLR & pin 2 of second XLR.
4 The cable screen goes to pin 1 of both XLR plugs.
5 In each lead, first XLR goes to INPUT A (INPUT C) and second XLR goes to INPUT B (INPUT D).
A750 • A1000 • A1004 • A1500 • A2000 • A3000 • A4000 • A5003 • Q900
1 Bring the input signal into channel A as usual.
2 Make a lead with an inline XLR socket to go to the Channel A LINK connector and an XLR plug
to go to the Channel B INPUT socket.
3 Connect socket pin 2 to plug pin 3 and similarly, socket pin 3 to plug pin 2.
Q900: Make a second lead as above for channels C & D.
Outputs
A500 • A750 • A1000 • A1004 • A1500 • A2000 • A3000 • A4000 • A5003 • Q900
1 Split the speaker cable by separating the two conductors for a distance of 20cm along
cable.
2 Connect the red conductor to terminal 1+ of the Channel A Speakon connector.
3 Connect the black connector to terminal 1+ of the Channel B Speakon connector.
Do not make connections to any other terminals. Q900: Repeat the above for channels C & D.
Q6 • Q1004
1 Connect the red conductor of the speaker cable to terminal 1+ of channel A (C) Speakon conn.
2 Connect the black conductor of the speaker cable to terminal 2+ of channel B (D) Speakon conn.
WARNING: Do not make connections to terminals 1– or 2–.
Operation
Set the gain controls of both channels in the same position (preferably at maximum), and control
the gain from elsewhere in the system. This ensures the load is shared equally between channels.
Loading and power output
Please see the rear page for mono bridge loading and power output values.
6
Operation & Servicing
Switching on
1 Turn the gain controls to the minimum positions.
2 Connect the unit to a mains supply of sufficient power and click the front panel switch(es)
to the ON position. Depending on the internal temperature, the fans may run.
• The green Power indicators will illuminate.
• The red Clip indicators will illuminate if overdriving is imminent.
WARNING: Keep sound levels down. High levels of sound can damage hearing.
Switching off
• Turn the gain control(s) to the minimum position(s). Click the front panel switch(es) to the
OFF position and disconnect from the mains supply.
WARNING: High voltages are present at output terminals for a period after switching off.
Protection systems
• Mains power supply failure: When power is restored, the amp will AutoMute for five seconds.
Do not increase gain settings during this period. Note: A500, A700v, Line250 and Line500
do not AutoMute.
• Shorted output: The unit can operate indefinitely into a shorted output. Normal operation
will resume upon removal of the short circuit.
• Low load impedance: Protection is immediate.
• Clipping: The affected channel’s red Clip indicator will illuminate shortly before clipping.
A further increase in signal level will activate the SoftClip circuit.
• RF, DC or very low frequency signal at output: A self resetting circuit will activate to
protect the load.
• Cooling systems: The internal fans react to both high signal level and temperature inside
the unit. If the ambient temperature is high, fan speed will increase even in the absence of
a signal.
Servicing
WARNING: All servicing and internal maintenance must be referred to an authorised Chevin
dealer. Chevin Research accepts no responsibility or liability relating to injury or damages
suffered as a result of misuse or unauthorised tampering with amplifiers.
• Do not remove any covers or touch any internal parts. Do not allow any objects (e.g.
screwdrivers, cable ends, etc.) to enter the unit.
• If the unit of any other electrical equipment in the system becomes wet during operation,
disconnect the power source immediately. Do not touch the amplifier. Consult a qualified
engineer.
• If there are any signs of mechanical damage, disconnect the power source and consult a
qualified engineer.
7
A500
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
POWER
SIGNAL
CLIP
CHANNEL A
A500 LINEAR AMPLIFIER
Channel A
gain
control
POWER
CHANNEL B
Power, Clip
and Signal
indicators
Channel B
gain
control
A700v
Power switch
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
POWER
SIGNAL
CLIP
POWER
GAIN
A700v LINEAR AMPLIFIER
Power, Clip
and Signal
indicators
Q1004
Q1004 • QB1000/600
POWER
1
QB1000/600
CLIP
SIGNAL
0
INF
CHANNEL B
CHANNEL A
10
00 600
POWER
1
20
CLIP
SIGNAL
0
INF
ATTENUATION dB
600W
Power, Clip
and Signal
indicators
0
INF
INF
ATTENUATION dB
CHANNEL D
ATTENUATION dB
1000W
1000W
(Channel B)
gain control
Channel D
gain
control
6
3
POWER
1
20
0
INF
ATTENUATION dB
1000W
1000W
(Channel C)
gain control
Power
switch
CHANNEL D
6
1
20
0
Power, Clip
and Signal
indicators
10
POWER
1
20
CHANNEL C
Channel C
gain
control
3
10
CHANNEL C
3
10
CLIP
SIGNAL
ATTENUATION dB
6
3
10
1
0
INF
CHANNEL B
6
QB
Q1004
Channel B
gain
control
Power, Clip
and Signal
indicators
POWER
20
0
ATTENUATION dB
3
10
1
20
CHANNEL A
6
6
3
10
INF
ATTENUATION dB
600W
(Channel A)
gain control
8
6
3
20
Power switch
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANELS
6
10
Channel A
gain
control
Gain
control
CLIP
SIGNAL
3
10
POWER
1
20
0
INF
ATTENUATION dB
600W
Power, Clip
and Signal
indicators
600W
(Channel D)
gain control
Power
switch
A500
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
CHANNEL B
O
U
T
P
U
T
I
N
P
U
T
Channel B
Output
connector
CONNECTOR WIRING
INPUT
2 HOT 3 COLD 1 GND
OUTPUT
1+HOT 1-COLD
MINIMUM LOAD 4 OHMS
FUSE
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
LINEAR AUDIO POWER
AMPLIFIER MODEL: A500
Channel B
Input
connector
A700v
CHANNEL A
FUSE RATING
110-120V = 16A
220-240V = 7A
PLEASE SEE
MANUAL
DANGER OF
ELECTRIC SHOCK
WHEN COVERS REMOVED
SN:
Fuse
Mains input
CONNECTOR WIRING
INPUT
2 HOT 3 COLD 1 GND
OUTPUT
1+HOT 1-COLD
MINIMUM LOAD 4 OHMS
I
N
P
U
T
Channel A
Input
connector
O
U
T
P
U
T
Channel A
Output
connector
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
O
U
T
P
U
T
Output
connector
I
N
P
U
T
FUSE
CONNECTOR WIRING
INPUT
2 HOT 3 COLD 1 GND
OUTPUT
1+HOT 1-COLD
MINIMUM LOAD 4 OHMS
FUSE RATING
110-120V = 16A
220-240V = 7A
PLEASE SEE
MANUAL
Input
connector
Q1004 • QB1000/600
DANGER OF
ELECTRIC SHOCK
WHEN COVERS REMOVED
SN:
Fuse
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
LINEAR AUDIO POWER
AMPLIFIER MODEL: A700v
Mains input
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANELS
CHANNEL C+D
INPUT D
INPUT C
CHANNEL A+B
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
INPUT B
INPUT A
FUSE RATING
220-240V = 40A
Q1004
PLEASE SEE MANUAL
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
OUTPUTS
OUTPUTS
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
LOAD 4 OHMS MINIMUM
CONNECTOR WIRING
Vari speed
cooling fan
Channel C & D
input XLR
sockets
CH.A:1+ HOT 1- COLD
CH.B:2+ HOT 2- COLD
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
SN
Channel C & D
output Speakon
sockets (1 per ch)
Fuse
Channel A & B
output Speakon
sockets (1 per ch)
CHANNEL C+D
QB1000/600
INPUT D
INPUT C
Channel A & B
input XLR
sockets
Vari speed
cooling fan
Channel A & B
input XLR
sockets
Vari speed
cooling fan
CHANNEL A+B
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
INPUT B
INPUT A
FUSE RATING
220-240V = 20A
110-120V = 40A
PLEASE SEE MANUAL
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
OUTPUT C/D
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
OUTPUT C/D LOAD 4 OHMS MINIMUM OUTPUT A/B
CONNECTOR WIRING
CH.D:2+ HOT 2- COLD (600W)
CH.C:1+ HOT 1- COLD (1000W)
LINEAR AUDIO
POWER AMPLIFIER
MODEL: QB1000/600
Vari speed
cooling fan
OUTPUTS
CONNECTOR WIRING
CH.D:1+ HOT 1- COLD
CH.C:2+ HOT 2- COLD
LINEAR AUDIO
POWER AMPLIFIER
MODEL: QB1004
OUTPUTS
Channel C & D
input XLR
sockets
CONNECTOR WIRING
CH.D:2+ HOT 2- COLD (600W)
CH.C:1+ HOT 1- COLD (1000W)
CH.A:2+ HOT 2- COLD (600W)
CH.B:1+ HOT 1- COLD (1000W)
CH.A:2+ HOT 2- COLD (600W)
CH.B:1+ HOT 1- COLD (1000W)
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
SN
Channel C & D
dual output
Speakon sockets
OUTPUT A/B
Fuse
Channel A & B
dual output
Speakon sockets
9
A750 • A1000 • A1004 • A1500 • A2000 • A3000
6
6
3
10
1
20
POWER
CLIP
SIGNAL
0
INF
3
10
1
20
0
INF
ATTENUATION dB
Axxxx LINEAR AMPLIFIER
SEE PAGE 6 • FRONT PANEL
ATTENUATION dB
CHANNEL A
POWER
CHANNEL B
Power, Clip
and Signal
indicators
Channel A
gain
control
Channel B
gain
control
A4000 • A5003
Power switch
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
POWER
6
6
10
3
1
20
INF
POWER
CLIP
SIGNAL
0
0
ATTENUATION dB
CHANNEL A
Channel A
gain
control
1
INF
ATTENUATION dB
Axxxx LINEAR AMPLIFIER
3
10
20
CHANNEL B
Power, Clip
and Signal
indicators
A5000 • A6000
Channel B
gain
control
Power switch
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
Model shown is A6000. Signal indicator values are different for A5000.
LIMITER
RMS
OUTPUT
VOLTS
84
72
60
48
36
24
12
CHANNEL A
POWER
POWER ON
A6000
LINEAR
POWER
AMPLIFIER
LIMITER
RMS
OUTPUT
VOLTS
84
72
60
48
36
24
12
CHANNEL B
POWER
POWER ON
The Limiter indicator lights when amp is being
driven into clip and shows SoftClip system is active.
If clip threshold is exceeded, the intensity of this LED
gives an indication of the degree of overdrive.
10
Power, Signal
& Limiter
indicators
Channel A
gain
control
Channel B
gain
control
Channel A and B
Power switches
A750 • A1000 • A1004 • A1500 • A2000 • A3000
FUSE
CHANNEL B
INPUT
LINK
OUTPUTS
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
Vari speed
cooling fan
Channel B
input and link
connectors
LINEAR AUDIO
POWER AMPLIFIER
MODEL: Axxxx
OUTPUTS
PLEASE SEE MANUAL
OUTPUTS
CONNECTOR WIRING
1+ HOT 1- COLD
FUSE RATING
SEE LEGEND ON AMPLIFIER
Channel B
dual output
connectors
A4000 • A5003
CHANNEL A
OUTPUTS
CONNECTOR WIRING
1+ HOT 1- COLD
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
SEE PAGES 3, 4 & 5 • REAR PANEL
LINK
INPUT
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
SN
Fuse
Channel A
dual output
connectors
Channel A
input and link
connectors
Vari speed
cooling fan
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
CHANNEL B
INPUT
LINK
CHANNEL A
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
LINK
INPUT
FUSE RATING
220-240V = 30A (40A)
PLEASE SEE MANUAL
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
OUTPUT
OUTPUT
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
LOAD 2 OHMS MINIMUM
CONNECTOR WIRING
1+ HOT 1- COLD
LINEAR AUDIO
POWER AMPLIFIER
MODEL: Axxxx
Vari speed
cooling fan
Channel B
input and link
connectors
OUTPUT
CONNECTOR WIRING
1+ HOT 1- COLD
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
SN
Channel B
dual output
connectors
A5000 • A6000
OUTPUT
Fuse
Channel A
dual output
connectors
Channel A
input and link
connectors
Vari speed
cooling fan
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
FUSE
CHANNEL A INPUT
INPUT
LINK
CHANNEL A OUTPUT
OUTPUTS
FUSE RATING
SEE LEGEND ON AMPLIFIER
OUTPUTS
PLEASE SEE MANUAL
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
WARNING
CONNECTOR WIRING
1+ HOT 1- COLD
THE 2 CHANNELS OF THIS AMPLIFIER
MUST NOT BE BRIDGED
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
LOAD 2 OHMS MINIMUM
FUSE
CHANNEL B INPUT
INPUT
LINK
FUSE RATING
SEE LEGEND ON AMPLIFIER
CHANNEL B OUTPUT
OUTPUTS
OUTPUTS
PLEASE SEE MANUAL
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
Vari speed
cooling fans
Channel A
input and link
connectors
LINEAR AUDIO
POWER AMPLIFIER
MODEL: Axxxx
DANGER
OF ELECTRIC SHOCK
WHEN COVERS REMOVED
CONNECTOR WIRING
1+ HOT 1- COLD
LOAD 2 OHMS MINIMUM
Channel B
input and link
connectors
Fuses
SN
Channel B
dual output
connectors
Channel A
dual output
connectors
Vari speed
cooling fans
11
Q6
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
6
10
6
3
1
20
INF
POWER
CLIP
SIGNAL
0
ATTENUATION dB
0
Q-6
Channel B
gain
control
CLIP
SIGNAL
0
INF
CHANNEL B
POWER
1
20
ATTENUATION dB
Power, Clip
and Signal
indicators
6
3
10
1
INF
CHANNEL A
Channel A
gain
control
6
3
10
20
3
1
INF
ATTENUATION dB
0
ATTENUATION dB
CHANNEL C
CHANNEL D
Channel C
gain
control
Q900
10
20
Power, Clip
and Signal
indicators
POWER
Channel D
gain
control
Power
switch
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
POWER
CLIP
SIGNAL
POWER
CHANNEL A
CHANNEL B
Q900
POWER
CLIP
SIGNAL
POWER
CHANNEL C
Channel A
gain
control
Channel C
gain
control
CHANNEL D
Power, Clip
and Signal
indicators
Line250 • Line500
6
10
INF
3
SIGNAL
CLIP
1
0
ATTENUATION dB
CHANNEL A
12
Channel A/B
and C/D Power
switches
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
20
Channel A
gain
control
Channel B
gain
control
Channel D
gain
control
Power, Clip
and Signal
indicators
SIGNAL
CLIP
POWER
6
10
3
1
20
INF
0
Line
line amplifier
ATTENUATION dB
CHANNEL B
Channel B
gain
control
Power switch
Q6
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
FUSE
CHANNEL C+D
INPUT D
INPUT C
OUTPUTS
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
CONNECTOR WIRING
CH.C: 1+ HOT 1- COLD
CH.D: 2+ HOT 2- COLD
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
LINEAR AUDIO
POWER AMPLIFIER
MODEL: Q6
Channel
C & D input
connectors
Vari speed
cooling fan
OUTPUTS
PLEASE SEE MANUAL
OUTPUTS
CONNECTOR WIRING
CH.A: 1+ HOT 1- COLD
CH.B: 2+ HOT 2- COLD
FUSE RATING
SEE LEGEND ON AMPLIFIER
Channel C+D
dual output
connectors
Q900
CHANNEL A+B
OUTPUTS
INPUT B
INPUT A
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
SN
Fuse
Channel A+B
dual output
connectors
Channel
A & B input
connectors
Vari speed
cooling fan
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
FUSE
CHANNEL B
INPUT
LINK
OUTPUT
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
OUTPUT
CONNECTOR WIRING
1+ HOT 1- COLD
OUTPUT
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
OUTPUT
PLEASE SEE MANUAL
Vari speed Channel B Channel D
Channel B
cooling fans input & link input & link & channel D
connectors connectors dual output
connectors
Line250 • Line500
Fuses
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
OUTPUT
CONNECTOR WIRING
1+ HOT 1- COLD
FUSE RATING
SEE LEGEND ON AMPLIFIER
LINEAR AUDIO
POWER AMPLIFIER
MODEL: Q900
INPUT
CHANNEL C
OUTPUT
CONNECTOR WIRING
1+ HOT 1- COLD
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY LS21 3LP
LINK
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
SN
FUSE
CHANNEL D
LINK
OUTPUT
CONNECTOR WIRING
1+ HOT 1- COLD
FUSE RATING
SEE LEGEND ON AMPLIFIER
PLEASE SEE MANUAL
INPUT
CHANNEL A
OUTPUT
LINK
INPUT
CONNECTOR WIRING
2 HOT 3 COLD 1 GND
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
SN
Channel A
& channel C
dual output
connectors
Channel C Channel A Vari speed
input & link input & link cooling fans
connectors connectors
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
CHANNEL B
CHANNEL A
0v 70v 100v
0v 70v 100v
OUTPUT
OUTPUT
FUSE
INPUT
1 GND
2 HOT
3 COLD
LINE AMPLIFIER
MODEL: LINE 500/250
Vari speed
cooling fan
1
2
3
FUSE RATING
500
LINE
110 - 120v
20A
220 - 240v
16A
1
2
3
INPUT
1 GND
2 HOT
3 COLD
MADE IN ENGLAND BY
CHEVIN RESEARCH LTD
OTLEY
LS21 3LP
250
10A
7A
SN
Channel B output
connector block
Channel B input
connector block
Fuse
Channel A input
connector block
Channel A output
connector block
Vari speed
cooling fan
13
14
General specifications
A500
RMS power output
into 4Ω (per chan.)
350W
into 8Ω (per chan.)
200W
No. of channels
2
Power bandwidth +0dB, -3dB
2Hz - 40kHz
Slew rate in excess of
40V/µS
Gain
x37.5
Total harmonic distortion
typical @ 1dB below clip
0.06%
20kHz @ 1dB below clip
0.08%
Signal to noise ratio
typ. ref. full output, unweighted
-120dB
Worst case 10Hz - 30kHz
-95dB
Crosstalk
typical
-115dB
worst case 10Hz - 30kHz
-95dB
Damping factor
400
Input impedance
electronically balanced
10kΩ
Common mode rejection (typ.)
-70dB
Input sensitivity
ref. full output into 4Ω
1V RMS
Protection
clipping
soft
load below 2.4Ω
dynamic linear
shorted output, DC or RF at output
immediate
Power consumption
1.2kVA
50/60Hz AC in volts
220-240V
internally selectable for
100-120V
Dimensions/weight
rack units
1U
height x width x depth (inches)
1.75x19x8.5
height x width x depth (mm)
44x483x215
gross weight
5.2kg/11.5lbs
net weight
4.7kg/9lbs
-115dB
-95dB
400
10kΩ
-70dB
1V RMS
n/a
n/a
400
10kΩ
-70dB
1V RMS
1V RMS
10kΩ
-70dB
-115dB
-95dB
400
-125dB
-95dB
2U
3.5x19x15
88x483x381
10kg/22lbs
8.5kg/19lbs
2U
3.5x19x15
88x483x381
10kg/22lbs
8.4kg/18.5lbs
125dB
-95dB
-120dB
-95dB
0.04%
0.07%
1U
1.75x19x8.5
44x483x215
5.1kg/11.2lbs
4kg/8.8lbs
0.04%
0.07%
0.06%
0.08%
600W
350W
2
2Hz - 80kHz
75V/µS
x50
soft
soft
dynamic linear dynamic linear
immediate
immediate
1.5kVA
2kVA
220-240V
220-240V
100-120V
100-120V
425W
250W
2
2Hz - 80kHz
75V/µS
x40
n/a
600W
1
2Hz - 40kHz
40V/µS
x70
A1000
soft
dynamic linear
immediate
1.2kVA
220-240V
100-120V
A750
A700v
2U
3.5x19x15
88x483x381
13.3kg/29lbs
11.7kg/26lbs
soft
dynamic linear
immediate
3.3kVA
220-240V
100-120V
1V RMS
10kΩ
-70dB
-115dB
-95dB
400
-125dB
-95dB
0.04%
0.07%
1000W
600W
2
2Hz - 80kHz
75V/µS
x65
A1004
2U
3.5x19x15
88x483x381
14kg/31lbs
12.4kg/27lbs
soft
dynamic linear
immediate
4kVA
220-240V
100-120V
1V RMS
10kΩ
-70dB
-115dB
-95dB
400
-125dB
-95dB
0.04%
0.07%
1250W
650W
2
2Hz - 80kHz
60V/µS
x70
A1500
QB1000/600
1V RMS
10kΩ
-70dB
-115dB
-95dB
400
-125dB
-95dB
0.04%
0.07%
2U
3U
3.5x19x15
5.25x19x15
88x483x381 132x483x381
14kg/30.9lbs 16kg/34lbs
12.3kg/27lbs 14kg/29.6lbs
3U
5.25x19x15
132x483x381
20kg/44lbs
18kg/40.5lbs
soft
dynamic linear
immediate
5.2kVA
220-240V
100-120V
1V RMS
10kΩ
-70dB
-115dB
-95dB
400
-125dB
-95dB
0.04%
0.07%
1000W
2x1000W/2x600W
600W
2x600W/2x350W
4
4
2Hz - 80kHz
2Hz - 80kHz
75V/µS
75V/µS
x65
x65 / x50
Q1004
soft
soft
dynamic linear dynamic linear
immediate
immediate
4kVA
6.6kVA
220-240V
220-240V
100-120V
n/a
1V RMS
10kΩ
-70dB
-115dB
-95dB
400
-125dB
-95dB
0.04%
0.07%
600W
350W
4
2Hz - 80kHz
75V/µS
x50
Q6
15
General specifications
Q900
RMS power output (10Hz-20kHz)
into 2Ω (per chan.)
1600W
into 4Ω (per chan.)
900W
into 8Ω (per chan.)
500W
No. of channels
4
Power bandwidth +0dB, -3dB
2Hz - 80kHz
Slew rate in excess of
50V/µS
Gain
x60
Total harmonic distortion
typical @ 1dB below clip
0.04%
20kHz @ 1dB below clip
0.07%
Signal to noise ratio
typ. ref. full output, unweighted
-125dB
Worst case 10Hz - 30kHz
-95dB
Crosstalk
typical
-115dB
worst case 10Hz - 30kHz
-95dB
Damping factor
400
Input imped. electronically balanced
10kΩ
Common mode rejection (typ.)
-70dB
Input sensitivity
ref. full output into 4Ω
1V RMS
Protection
clipping
soft
load below 1.2Ω
dynamic linear
shorted output, DC or RF at output
immediate
Power consumption
5.3kVA per pair
50/60Hz AC in volts
220-240V
internally selectable for
100-120V
Dimensions/weight
rack units
4U
height x width x depth (inches)
7x19x15
height x width x depth (mm)
178x483x381
gross weight
23.5kg/59lbs
net weight
21.5kg/47.4lbs
-115dB
-95dB
400
10kΩ
-70dB
1V RMS
-115dB
-95dB
400
10kΩ
-70dB
1V RMS
1V RMS
-115dB
-95dB
400
10kΩ
-70dB
-125dB
-95dB
1V RMS
-115dB
-95dB
400
10kΩ
-70dB
-125dB
-95dB
0.04%
0.07%
1V RMS
-115dB
-95dB
400
10kΩ
-70dB
-125dB
-95dB
0.04%
0.07%
2500W
1500W
900W
2
2Hz - 80kHz
65V/µS
x70
Line250
3U
4U
3U
5.25x19x15
7x19x15
5.25x19x15
132x483x381 178x483x381 132x483x381
16kg/34lbs
23.5kg/59lbs
16kg/34lbs
14kg/29.6lbs 21.5kg/47.4lbs 14kg/29.6lbs
Line500
1V RMS
-115dB
-95dB
400
10kΩ
-70dB
-125dB
-95dB
0.04%
0.07%
1V RMS
-115dB
-95dB
n/a
10kΩ
-70dB
-120dB
-95dB
0.04%
n/a
4U
7x19x15
178x483x381
23.5kg/59lbs
21.5kg/47.4lbs
3U
5.25x19x15
132x483x381
18kg/40lbs
16kg/36lbs
3U
5.25x19x15
132x483x381
22kg/50lbs
20kg/45lbs
soft
n/a
immediate
1.6kVA
220-240V
100-120V
1V RMS
-115dB
-95dB
n/a
10kΩ
-70dB
-120dB
-95dB
0.04%
n/a
3000W
Line operation: Line operation:
2000W
70V
100V 70V
100V
1200W 175W 250W 350W 500W
2
2
2
2Hz - 50kHz 30Hz - 16kHz
30Hz - 16kHz
50V/µS
40V/µS
40V/µS
x90
n/a
n/a
A6000
2U
3.5x19x15
88x483x381
14kg/31lbs
12.4kg/27lbs
-125dB
-95dB
-125dB
-95dB
0.04%
0.07%
2500W
1500W
900W
2
2Hz - 50kHz
50V/µS
x70
A5003
2U
3.5x19x15
88x483x381
13.3kg/29lbs
11.7kg/26lbs
0.04%
0.07%
0.04%
0.07%
2000W
1000W
600W
2
2Hz - 80kHz
65V/µS
x65
A5000
soft
soft
soft
soft
soft
soft
dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear
n/a
immediate
immediate
immediate
immediate
immediate
immediate
5.3kVA
6.6kVA
4kVA per chan.
8kVA
5.3kVA per chan.
1kVA
220-240V
220-240V
220-240V
220-240V
220-240V
220-240V
100-120V
n/a
100-120V
n/a
100-120V
100-120V
1600W
900W
500W
2
2Hz - 80kHz
50V/µS
x60
1200W
650W
350W
2
2Hz - 80kHz
75V/µS
x50
A4000
soft
dynamic linear
immediate
3.9kVA
220-240V
100-120V
A3000
A2000
Mono bridge loading and power outputs (see page 6 for details)
Model
Minimum load
Power output
A500
A750
A1000
A1004
A1500
A2000
A3000
A4000
A5003
Q900
Q6
Q1004
1 load of 8Ω
1 load of 8Ω
1 load of 8Ω
1 load of 8Ω
1 load of 8Ω
1 load of 4Ω
1 load of 4Ω
1 load of 4Ω
1 load of 4Ω
1 load of 4Ω per channel pair
1 load of 8Ω per channel pair
1 load of 8Ω per channel pair
650W
850W
1200W
2000W
2500W
2400W
3000W
4000W
5000W
3000W per channel pair
1200W per channel pair
2000W per channel pair
Warranty
This precision engineered CHEVIN product is guaranteed against defects due to faulty materials and
workmanship for a period of twenty four (24) months from the date of the original purchase, subject to
the following restrictions:
• This warranty is only valid in the country of purchase
• The equipment has not been abused or operated in conjunction with unsuitable or faulty apparatus.
The equipment has not been disassembled, modified or tampered with by any person other than our
CHEVIN staff or overseas by our own or distributors’ staff.
• The equipment has not suffered damage in transit.
Should service be required, notify the dealer from whom you purchased the equipment to arrange for an
authorised CHEVIN agent to confirm the need for attention.
• Do not dispatch the goods without the prior approval of CHEVIN or its authorised agents. If asked to
return the goods, pack them carefully (preferably in the original carton) and return pre-paid. Insurance
is recommended as goods are returned at owner’s risk.
• Packing insurance and freight on the return journey will be paid for by CHEVIN or its authorised agents
only if warranty work proves necessary. If warranty work proves unnecessary, goods will be released
upon payment by the owner for charges for non-warranty repair work and return packing, insurance
and freight.
• The attached warranty card should be completed and returned to CHEVIN RESEARCH LTD.
• Failure to register by not returning the warranty card in no way limits or invalidates the warranty, but
in the event of service being required, delay may result since warranty work cannot begin until the
original sale has been verified.
• In case of difficulty, contact CHEVIN RESEARCH LTD. This warranty in no way affects your statutory
rights.
Chevin Research Ltd., 41a Ilkley Road, Otley, West Yorkshire LS21 3LP ENGLAND
Tel: +44 (0)1943 466060 • Fax: +44 (0)1943 466020
www.chevin-research.com • [email protected]
This manual is intended for informational purposes only. All details included herein are subject to change
without notice. Chevin Research Ltd. shall not be held responsible for any damages, direct or indirect,
arising from or relating to the use of this manual.
© Chevin Research Ltd. 2004. All rights reserved.
Range guide • 1.0c • Dec 2004