Download User Manual Smart Power Transducer PD1000

Transcript
User Manual
Smart Power Transducer
PD1000
UMPD1000A
Brainchild Electronic Co., Ltd.
V1.0, 05/2007
Content
Chapter 1 Introduction……………………………………………………………………4
1.1 Product Introduction………………………………………………………………………………………………………………….4
1.2 Caution……………………………………………………………………………………………………………………………………….5
1.2.1 Danger……………………………………………………………………………………..…………………….…………………5
1.2.2 PRODUCT WARRANTY & CUSTOMER SUPPORT……………………………………………………………….5
1.2.3 LIMITATION OF WARRANTY……………………………………………………………………………………………..5
Chapter 2 Detail Specification……………………………………………………….….6
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
Power parameters measure………………………………………………………………………………………………….……..6
Energy measure……………………………………………………………………………………………………………………….…..6
Demand measure…………………………………………………………………………………………………………………….…..6
Power Quality measure…………………………………………………………………………………………………………….….6
Report and event logging……………………………………………………………………………………………………………..6
Display and input/output……………………………………………………………………………………………………………..6
Communication…………………………………………………………………………………………………………………………….6
Environmental & Physical…………………………………………………………………………………………………….……….6
Ordering Code……………………………………………………………………………………………………………………..……….7
Chapter 3 Installation…………………………………………………………….………..8
3.1 Safety……………………………………………………………………………………………………………………………...……………8
3.2 Mounting.……………………………………………………………………………………………………………………………………..8
Chapter 4 Connection………………………………………………………………………9
4.1 Back view of connect port……………………………………………………………………………………………………………9
4.1.1 Digital Output…………………………………………………………………………………………………………………..10
4.1.2 Analog Output………………………………………………………………………………………………………………….10
4.1.3 Digital Input…………………………………………………………………………………………………………………….10
4.1.4 Analog Input…………………………………………………………………………………………………………………….10
4.1.5 Aux. Power Supply……………………………………………………………………………………………………………11
4.1.6 Current Terminal………………………………………………………………………………………………………………11
4.1.7 Voltage Terminal………………………………………………………………………………………………………………11
4.2 Wiring diagram……………………………………………………………………………………………………………………………12
4.2.1 1P2W/1CT.......................................................................................................12
4.2.2 1P3W/2CT.......................................................................................................12
4.2.3 3P3W/2CT.......................................................................................................12
4.2.4 3P3W/3CT.......................................................................................................13
4.2.5 3P4W/3CT…………………………………………………………………………………………………………………………13
Chapter 5 Function Tree…………………………………………………………………14
Chapter 6 RunTime………………………………………………………………………..16
6.1 Display………………………………………………………………………………………………………………………………………..16
6.2 Run Time Auto scroll…………………………………………………………………………………………………………………..16
Chapter 7 Set up mode operation…………………………………………………….17
7.1 Display and keyboard…………………………………………………………………………………………………………..…….17
7.2 Set up………………………………………………………………………………………………………………………………………….18
7.2.1 Clear Function………………………………………………………………………………………………………………….18
7.2.2 Basic Setup………………………………………………………………………………………………………………………19
7.2.2.1 Communication………………………………………………………………………………………………………...19
7.2.2.2 Measurement…………………………………………………………………………………………………………….19
7.2.2.3 Security…………………………………………………………………………………………………………………..…20
7.2.2.4 Alarm Set Point………………………………………………………………………………………………………….20
7.2.2.5 Clock Setup……………………………………………………………………………………………………………….22
7.2.2.6 Digital Output………………………………………………………………………………………………………….…22
2
7.2.2.7 Analog Output Setting………………………………………………………………………………………………22
7.2.2.8 Analog input……………………………………………………………………………………………………………..23
7.2.2.9 Demand Setup…………………………………………………………………………………………………………..23
7.2.2.10 Period Reset…………………………………………………………………………………………………………….24
7.2.3 Display setup…..………………………………………………………………………………………………………………24
7.3 Report……………………………………………………………………………………….…………………………………………………25
7.3.1 Daily Report…………………………………………………………………….……………………………………………….25
7.3.2 Diagnostic………………………………………………………………………………………………………………………..25
7.3.3 Harmonics……………………………………………………………………………………………………………………….27
7.3.4 Current on alarm……………………………………………………………………………………………………………..27
7.3.5 Even log…………………………………………………………………………………………………………………………..27
7.3.5.1 Sag Record………………………………………………………………………………………………………………..27
7.3.5.2 Swell record……………………………………………………………………………………………………………….28
7.3.5.3 Alarm Record…………………………………………………………………………………………………………….28
7.3.5.4 Analog input……………………………………………………………………………………………………………..28
7.3.5.5 Nameplate Info……………………………………………………………………………………………………….…28
Chapter 8 Communication format...........................................................29
8.1 RS485......................................................................................................................29
8.1.1 RS485 standard...............................................................................................29
8.1.2 Wiring for instruments communication………………………………………………………………………….29
8.2 Modbus………………………………………………………………………………………………………………………………………..30
8.2.1 Modbus Format8.3 Communication protocol..........................................................30
8.3 Communication protocol…………………………………………………………………………………………………………….30
8.4 Detail Parameters……………………………………………………………………………………………………………………….31
3
Chapter 1 Introduction
1.1 Product Introduction
PD1000 is designed for continuous monitoring of 3 phase system. All essential power parameters
measure including current, voltage, power, active and reactive energy are integrated in a single
meter. Its bi-directional energy measurement and harmonic analysis function makes PD1000
suitable for modern industrial power management. The built-in Ethernet and rich communication
abilities enable PD1000 to be easily connected with most modern third-party SCADA systems.
Features
Standard
Model
Advanced
Model
Power parameters measure
Current:3 phase, neutral, accuracy 0.1%
Voltage:3 phase phase-phase, phase-neutral, accuracy 0.1%
•
•
•
•
Frequency:50/60 Hz
•
•
Total power:Active, reactive, apparent power, accuracy 0.5%
•
•
Power per phase:Active, reactive, apparent power, accuracy 0.5%
•
•
Power factor:Total, per phase
•
•
Auto wiring detection
•
•
Energy:Active, reactive, apparent energy, accuracy 0.5%
Bi-directional energy:Deliver and receive kWh, kVARh, kVAh
Display and input/output
•
•
•
•
Panel display:Mono 128 x 128 STN-LCD
Digital input:12 channel dry contact inputs
Digital output:2 channel relays for alarm or kWh pulse output
Analog input:4 channel 4-20mA inputs(option)
Analog output:4 channels 4~20mA for V, I, kW, kVA, kVAR(option)
Voltage connection:1~600V
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Energy measure
Current connection:2mA~5A
Power supply:86~242VAC or 100~125VDC
Communication
Primary port:RS485 Modbus or DNP 3.0 protocol
Secondary port:Ethernet : 10/100 Mbps, Modbus over TCP/IP protocol(option)
Free topology twist pair:LonTalks protocol(option)
Demand measure
Block/Rolling demand
Power Quality measure
Harmonic:V, I THD and individual harmonics
Sag/Swell:Configurable setting points
Report and event logging
•
•
•
Report:Daily report : this day, yesterday;Regular report : this period, last reset
•
Event logging:Sag, swell, alarm logging
•
4
1.2 Caution
1.2.1 Danger
PD1000 contains hazardous voltages. The meter should never be disassembled. Failure to observe
this practice can result in serious injury or death. Any work on or near energized meters, meter
sockets, or other metering equipment can present a danger of electrical shock. It is strongly
recommended that all work should be performed only by qualified industrial electricians and
metering specialist. We assume no responsibility if your electrical installer does not follow the
appropriate national and local electrical codes.
1.2.2 PRODUCT WARRANTY & CUSTOMER SUPPORT
Brainchild warrant all products free from defects in material and workmanship for a period of one
year from the date of shipping. During the warranty period, Brainchild will, at our position repair the
product that proves to be defective.
Please have the model, serial number and a detailed problem description available. If the problem
concerns a particular reading, please have all meter readings available. When returning any
merchandise to us, a return materials calibration number is required.
1.2.3 LIMITATION OF WARRANTY
This warranty does not apply to defects resulting from unauthorized modification, misuse, or use for
reasons other than electrical power monitoring. The supplied meter is not a user-serviceable
product.
5
Chapter 2 General Features
*:only in Advanced model
2.1 Power parameters measure and accuracy
Current:3 phase, neutral, accuracy < 0.1%
Voltage:3 phase phase-phase, phase-neutral, accuracy < 0.1%
Frequency:47/63 Hz
Total power:Active, reactive, apparent power, accuracy < 0.5%
Power per phase:Active, reactive, apparent power, accuracy < 0.5%
Power factor:Total, per phase
2.2 Energy measure
Energy:Active, reactive, apparent energy, accuracy < 0.5%
Bi-directional energy:Deliver and receive kWh, kVARh, kVAh
2.3 Demand measure*
Bi-directional Block/Rolling demand
2.4 Power Quality measure*
Harmonic:V, I THD and individual harmonics, up to 31 orders
Sag/Swell:Configurable setting points
2.5 Report and event logging*
Report:Daily report : this day, yesterday
Regular report : this period, last reset
Event logging:Sag, swell, alarm logging
2.6 Display and input/output
Panel display:Mono 128 x 128 STN-LCD
Digital input:12 channel dry contact inputs
Digital output:2 channel relays for alarm and kWh pulse output
Analog input:4 channel 4-20mA inputs(option)
Analog output:4 channels 4~20mA for V, I, kW, kVA, kVAR(option)
Voltage connection:1~600V
Current connection:2mA~5A
Power supply:86~242VAC or 100~125VDC
2.7 Communication
Primary port:RS485 Modbus or DNP 3.0 protocol
*
Secondary port :Ethernet : 10/100 Mbps, Modbus over TCP/IP protocol,
*
Free topology twist pair :LonTalks protocol
2.8 Environmental & Physical
Operation temperature:-10℃to 55℃
Storage temperature:-25℃ to 60℃
Humidity:95%RH (non-condensing)
Dimensions:142mm(L) x 142mm(W) x 94mm(H)
6
2.9 Ordering Code
PD1000 - □ □ □ □
Model
0:Standard
1:Advance (with* in specification)
Secondary Port
0:None
1:Ethernet (in advanced model only)
2:Free topology twist pair Lontalks
(To be available in near future)
AI function
0:None
1:With AI function
AO function
0:None
1:With AO function
Note:Standard model does not offer secondary port
7
Chapter 3 Installation
3.1 Safety
On receipt of the instrument and prior to installation, makes sure it has not been damaged during
shipment.
The instrument is no longer safe when,
a) shows clear signs of damage
b) does not work
c) long storage under extreme conditions
d) damage during shipment
3.2 Mounting
z
z
z
z
This instrument should install on vibration free switchboard and with environment temperature
between -10℃~55℃, humility between 20-80%RH(no condensing)
For the instrument is already equipped with an internal protection fuse, a 1AmAT HBC fuse is
recommended during installation
Prior to maintain/repair this instrument, always disconnect this instrument from all power
sources
Only have qualified and authorized personnel to carry out installation, maintenance and repair
After mounting the instrument, place all four supports latch in position.
Panel cutout area is 138x138mm(+or- 0.5mm)
8
Chapter 4 Connection
4.1 Back view of connection port
9.
8.
7.
4.
3.
2.
10.
1.
5.
6.
12.
11.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
AUX. power
Digital output (Com1 DO1 Com0 DO0)
Analog output (Com1 AO3 AO2 AO1 AO0)
Digital input (Com1 DI13 DI12 DI11 DI10)
Digital input (DI30 DI31 DI32 DI33 Com3)
Digital input (DI20 DI21 DI22 DI23 Com2)
RS485 port (D- D+)
Lon Talks port (D- D+)
Ethernet port
Analog input (AI0+ AI0- AI1+ AI1- AI2+ AI2- AI3+ AI3-)
Current terminal (3L 3S 2L 2S 1L 1S)
Voltage terminal (C.B.A.N)
9
4.1.1 Digital Output
z
2 channel 4 pin digital outputs (Com1 DO1 Com0 DO0)
z
12-230VAC-DC/120mA max
z
Com0 DO0 for digital output1, Com1 DO1 for digital output 2
z
Port 1 assign selection : V/I Unbal Alarm, THD Alarm, Over V/I Alarm, Under V Alarm, V/I Loss
Alarm
z
Port 2 assign selection : Energy pulse kh(pulse/kWh)
4.1.2 Analog Output
z
4 channel 5 pin current outputs (Com1 AO3 AO2 AO1 AO0)
z
4-20mA current output
z
4 analog outputs selection:phase, voltage, current, power…
4.1.3 Digital Input
z
3 groups of 12 channel, 15 pin digital inputs (Com1 DI13 DI12 DI11 DI10)、 (DI20 DI21 DI22
DI23 Com2) 、(DI30 DI31 DI32 DI33 Com3)
z
5-24Vdc
4.1.4 Analog Input
z
4 channel 8 pin analog inputs (AI0+ AI0- AI1+ AI1- AI2+ AI2- AI3+ AI3-)
z
4-20mA input
10
4.1.5 Aux. Power Supply
z
Before powering the instrument, verify the pin position at L and N, leave the middle pin blank.
z
Power standard is 86-242Vac/100-125Vdc.
z
An internal protection fuse 250V, 1A is equipped.
z
The instrument power supply must not be earthed.
4.1.6 Current Terminal
z
The current input are 3 channels/6 terminals (3L 3S 2L 2S 1L 1S)
z
Input current range from 2mA to 5A (CT secondary)
Warning !
The CT input current must not exceed 10A
4.1.7 Voltage Terminal
z
There are 4 voltage terminals(C.B.A.N) 。
z
The instrument measure voltage from 0 to 120V, up to a maximum 600V.(PT secondary)
z
Voltage must not exceed 600V. In case of over 600V, voltage transformer needs to be applied.
Note !
3P3W/2CT and 3P3W/3CT wiring, only connect “C A N”, and leave “B” blank
11
4.2 Wiring diagram
4.2.1 1P2W/1CT
3L
3S
2L
2S
1L
1S
C
B
A
N
2L
2S
1L
1S
C
B
A
N
2L
2S
1L
1S
C
B
A
N
L
N
4.2.2 1P3W/2CT
3L
3S
L1
L2
N
4.2.3 3P3W/2CT
3L
3S
L1
L2
L3
12
4.2.4 3P3W/3CT
3L
3S
2L
2S
1L
1S
C
B
A
N
2L
2S
1L
1S
C
B
A
N
L1
L2
L3
4.2.5 3P4W/3CT
3L
3S
L1
L2
L3
N
13
Chapter 5 Function Tree
Select Manual
Clear Function
Basic Setup
Setup
Display Setup
Setup
Report
Daily Reset
Energy Reset
Sag Reset
Swell Reset
Sag/ Swell Reset
Alarm Rcd Rese
Reset to Default
Reset All
Demand Reset
Period Reset
Communication
Modbus
Baud Rate
CM1 Unit ID
Stop Bit
Parity Bit
Ethernet
IP Address
Port No
Subnet Mask
Gateway
Mac Address
Measurement
Volts Mode
PT Primary
PT Secondary
CT Primary
CT Secondary
Frequency
Security
Alarm Set Point
Modify PWord
Enable/Disable
Sag/Swell Limit
Alarm Set Point
V Unbal Alarm
I Unbal Alarm
THD Alarm
Over I Phase Alarm
Over I Neutral Alarm
I Loss Alarm
V Loss Alarm
Alarm Clear Point
V Unbal Alarm
I Unbal Alarm
THD Alarm
Over I Phase Alarm
Over I Neutral Alarm
I Loss Alarm
V Loss Alarm
Clock Setup
Date
Time
Digital Output
Digital Output 1
Digital Output 2
Analog Output
Analog Output 1
Analog Output 2
Analog Output 3
Analog Output 4
Analog Input
Analog Input 1
Analog Input 2
Analog Input 3
Analog Input 4
Demand Setup
Mode
No. of Subinterval
Subinterval Length
Period Reset
Mode
Date
Auto Scroll
Backlight Timeout
Runtime
Sag Limit
Swell Limit
Ref. Primary Voltage
Voltage
Line Current
Power
Power Factor
Energy
Demand
Status
Item
Kh
Phase
Item
AI High Value
AI Low Value
Phase Voltage
Line Voltage
Active Power
Apparent Power
Reactive Power
14
Report
Daily Report
Diagnostic
Harmonics
Alarm
Event Log
Analog Input
Nameplate Info
Today
Energy
Max/Min Total Power
Max/Min V Avg
Max/Min I Avg
Yesterday
Energy
Max/Min Total Power
Max/Min V Avg
Max/Min I Avg
This Period
Last Reset
Va Harmonics
Vb Harmonics
Vc Harmonics
Ia Harmonics
Ib Harmonics
Ic Harmonics
Sag Record
Swell Record
Alarm Record
15
Chapter 6 Run Time
In runtime mode, the instrument is able to measure and store all real time electrical parameters.
Following is the table that this instrument can display.
6.1 Display
Display
Average / ΣResult
Phase Voltage
Line Voltage
Line Current
Active Power
Apparent Power
Items
Vavg、Iavg、ΣLW、ΣLVAR
L12 、L23 、L31 V, kV, MV
L1 、L2 、L3
V, kV, MV
L1 、L2 、L3、N A, kA, MA
L1、L2、L3、ΣL
W, kW, MW
L1、L2、L3、ΣL
kVA, kVA,
MVA
L1、L2、L3、ΣL
kVAr, kVAr,
MVAr
L1、L2、L3、ΣL
kWh del、rec、total
kVARh +(lagging)、-
(leading)、total
kW、Time
Freq: Hz
Digital Output 1〜2 ON/OFF
Digital Input 1〜4 ON/OFF
Digital Input 5〜12 ON/OFF
Reactive Power
Power Factor
Total Energy
Total Energy
Demand
Frequency / Status
Frequency / Status
6.2 Run Time Auto scroll
Each screen except Average/Result can be disable/enable individually in the setup mode, and auto
scroll time can be disabled or set from 1 to 6 second. The cruise keys are used to move from one
page to another one manually.
z
z
Use fto next page
Use eto previous page
16
Chapter 7 Set up mode
7.1 Display and keyboard
LCD graphic, LED back-lighted, 128 ×128
z
z
z
z
kWh light:Pulse output
Enter key:Entering setup mode, or confirm the selection
Esc key:Back to runtime mode or return to previous setup page
Arrow Key:Scroll select item or change the input number or shift input position
17
7.2 Set up
Press Enter to setup mode, enter password-xxxxxxx-7 digits,(default as 0000000), user can modify
password by:Setup→Basic Setup→Security→Modify PWord
z
Clear Function
z
Basic Setup
z
Display Setup
7.2.1 Clear Function
Clear function was designed to allow user to easily move and/or reset different data stored in this
instrument.
Nevertheless, energy data will not be reset due to its accumulation characteristics expect using the
function of “energy reset”.
Setup
Item
Daily Reset
Energy Reset
Sag Reset
No
„ Yes
„
Swell Reset
Sag/ Swell Reset
Alarm Rcd Reset
Reset to Default
Reset All
Demand Reset
Period Reset
z
z
z
z
z
z
z
z
z
z
Daily Reset:Clear this Day Max/Min & Yesterday Max/Min Record
Energy Reset:Reset kWh_del、kWh_rec、kWh_tot、kWh_net、kVarh_lagging、kVarh_leading、
kVArh_tot、 kVArh_net、kVAh
Sag Reset:Reset Sag Record
Swell Reset:Reset Swell Record
Sag/ Swell Reset:Reset Sag/Swell Record
Alarm Rcd Reset:Reset Alarm Record
Reset to Default:Reset all the parameters to default value
Reset All:Clear This Day Max/Min、Yesterday Max/Min 、Energy、Sag、Swell、Alarm、Demand
and move This Period Max/Min to Last Reset Max/Min, also recode reset time. Clear This Period
Max/Min
Demand Reset:Clear Demand data, restart Demand Interval
Period Reset:Move This Period Max/Min data to Last Reset Max/Min, record reset time, and
clear This Period Max/Min data
18
7.2.2 Basic Setup
7.2.2.1 Communication
z
Modbus
Please refer to the modbus format and parameters in the appendix.
z
z
z
z
Baud Rate:Default is 19200
CM1 Unit ID (1~255):RS485 Modbus ID address, default is 15
Stop Bit:bit to signal the end of communication, depending on PC side. Default is 1
Parity Bit:The total number of bit is always either odd or even, therefore it can be checked
during the communication. Default is none
z
Ethernet
z
z
z
IP Address:The IP address of computer host, “xxx.xxx.xxx.xxx” is required, here xxx is 0-255
Port No.:Port no. Has been defined as 502 or 503, please select 502 or 503
Subnet Mask:If subnet was used, host and subnet IP address are required, please use
“xxx.xxx.xxx.xxx” to set
Gateway:Gateway is used to enter other internet, “xxx.xxx.xxx.xxx” is required
Mac Address:It is 6 fixed number, can not be changed(xx-xx-xx-xx-xx-xx, 0-FF)
z
z
7.2.2.2 Measurement
z
z
z
z
z
z
Volts Mode:If auto is selected, the wiring method will be detected automatically. Default is Auto
PT Primary:60~6000000(primary voltage)
PT Secondary:1~600(secondary voltage)
CT Primary:1~5000(primary max. current)
CT Secondary:1~5(secondary max. current)
Frequency:Default is 60Hz
19
7.2.2.3 Security
If password cannot be recalled, please contact your local dealer. You can press “Enter” and “f key”
at the same time to reset every parameter to default values including password. The default value
of password is “000000”, 7 digits.
Press ef keys to move the desired position, cb keys can change the numerical or alphabetic letters
in the selected position
7.2.2.4 Alarm Set Point
z
Enable/Disable
To enable or disable the alarm setting, if enable is selected, it will be recorded as an event when the
alarm was triggered.
z
Sag/Swell Limit
Sag Limit
Sag limit can be set between 80 to 100%, “%” is the unit used. When measured voltage is lower
than the sag limit setting but no longer than 1 min. continuously, it will be treated as “Voltage Sag”.
If longer than 1 min., it will be recorded as “Low Voltage”. Use cb keys to change the setting value.
Swell Limit
Swell limit will be set between 100~120%. When the measure voltage is high than the swell limit
compared to primary voltage setting, for less than 1 min. it is treated as “voltage swell”. If longer
than 1 min., it will be recorded as “Over Voltage”. Use cb keys to change the setting value
Ref. Primary Voltage
Reference Voltage for sag and swell to compare with. (660~600000)
z
Alarm Set Point
Events due to alarm can be read through communication as defined in the following table:
Item
Description
0x10
Over Current Phase A Alarm
0x11
Over Current Phase B Alarm
0x12
Over Current Phase C Alarm
0x13
Over Current Neutral Alarm
0x14
Current Unbalance Alarm
0x15
Current Loss Alarm
0x20
Over Current Phase A Condition Clear
0x21
Over Current Phase B Condition Clear
0x22
Over Current Phase C Condition Clear
0x23
Over Current Neutral Condition Clear
0x24
Current Unbalance Condition Clear
0x25
Current Loss Condition Clear
20
0x30
0x31
0x32
0x33
0x34
0x35
0x36
0x37
0x40
0x41
0x42
0x43
0x44
0x45
0x46
0x47
Over Voltage Phase A Alarm
Over Voltage Phase B Alarm
Over Voltage Phase C Alarm
Under Voltage Phase A Alarm
Under Voltage Phase B Alarm
Under Voltage Phase C Alarm
Voltage Unbalance Alarm
Voltage Loss Alarm
Over Voltage Phase A Condition Clear
Over Voltage Phase B Condition Clear
Over Voltage Phase C Condition Clear
Under Voltage Phase A Condition Clear
Under Voltage Phase B Condition Clear
Under Voltage Phase C Condition Clear
Voltage Unbalance Condition Clear
Voltage Loss Condition Clear
0x50
0x51
0x52
0x53
0x54
0x55
0x60
0x61
0x62
0x63
0x64
0x65
THD
THD
THD
THD
THD
THD
THD
THD
THD
THD
THD
THD
Va Alarm
Vb Alarm
Vc Alarm
Ia Alarm
Ib Alarm
Ic Alarm
Va Alarm Condition Clear
Vb Alarm Condition Clear
Vc Alarm Condition Clear
Ia Alarm Condition Clear
Ib Alarm Condition Clear
Ic Alarm Condition Clear
V Unbal Alarm
The range of V unbal alarm limit can be set between 0~10%. Comparing voltage of any phase with
the average value of all three phase, if the ratio of the different is greater than the set limit, the
alarm will be triggered. As the ratio become lower than the set limit, alarm will be cleared.
I Unbal Alarm
The range of I unbal alarm limit can be set between 0~10%. Comparing current of any phase with
the average value of all three phase, if the ratio is greater than the set limit, the alarm will be
triggered. As the ratio become lower than the set limit, alarm will be cleared.
THD Alarm
Total harmonic distortion can be set between 0~5%.
Over I Phase Alarm
The over I phase limit can be set between 0~9999 of primary current. As the current of any phase
is over the set limit, alarm triggered. When the over I is below the limit, alarm cleared.
Over I Neutral Alarm
The over I neutral alarm can be set between 0-9999 of primary current. As the I neutral is over the
set limit, alarm triggered. When the over I neutral is below the set limit, alarm cleared.
I Loss Alarm
I loss alarm value can be set between 0-5000 of primary current. As only one or two I phase is below
the alarm setting value, alarm triggered. However, when all three I phase is either greater or lower
than the limit, alarm cleared.
V Loss Alarm
V loss alarm value can be set between 0-6000 of primary voltage. As only one or two V phase is
21
below the alarm setting value, alarm triggered. However, when all three V phase is either greater or
lower than the limit, alarm cleared.
7.2.2.5 Clock Setup
Date and time will be setup here for use in daily report and regular report and event logging. They
will be shown as yy/mm/dd and hh:mm:ss.
7.2.2.6 Digital Output
2 channel of digital outputs for alarm output and pulse output.
z
Digital Output 1
Alarm output can be selected from the list
z
Digital Output 2
Pulse output, the output item can be none, kWh, kVARh, kVAh. The output pulse unit can be either
1 wh/pulse or 1 kwh/pulse.
7.2.2.7 Analog Output
4 channels of 4-20mA setting, can be assigned to V, I, kW, kVA or kVAR
Data measured from secondary V, I, kW, kVA or kVAR;4-20mA corresponding to the value each
items are:
V:1~600V
I:2mA~5A
kW:3 kWatt
kVAR:3 kVAr
kVA:3 kVA
For each analog output, users can choose item like V, I and phase like A, B, all.
22
7.2.2.8 Analog input
AI high value can be from 0-65535, and the corresponding external input is 20mA;low value can be
from 0-65535, and the corresponding external value is 4mA.
7.2.2.9 Demand Setup
Mode
z
Block
Calculation updates at the end of the interval
15-minute interval
15
20
25
15-minute interval
30
35
15-min
Time
(min)
40
Block Mode
z
Rolling
Calculation updates at the end of the subinterval
15-minute interval
15
20
25
30
35
40
Rolling
23
45
Time
(min)
No. of Subinterval
The No. of subinterval is only needed for Rolling mode, can be 1, 2, 3, 4, 5, 6 or 10
Subinterval Length
Function for both Block and Rolling mode. In block mode, it stands for the total interval time.(No.
of subinterval is always 1). In rolling mode, it stand for only length of the subinterval time, the total
interval time will be No. of subinterval times the length subinterval.
7.2.2.10 Period Reset
The function of period reset is designed to move the max/min data happened in one current month
to last period, and clear all the max/min data in this month period for the new coming max/min data
except the energy data. Energy data will not be reset, instead it will be accumulated.
z
Mode
When manual is selected, the reset action will be triggered only the reset all in clear function has
been applied.
If auto is selected, users will also be asked to enter the date. The system will perform the move and
clear action at the date assigned every month.
If date is 2, then at date 2 and 00:00:00 period reset will be executed.
If date is 1, then at date 1 and 00:00:00 period reset will be executed.
If date is 31, then only the month with 31st period reset will be executed at 31st 00:00:00. However,
those months without 31st, period reset will executed at 1st 00:00:00 next month.
7.2.3 Display Setup
z
z
z
Auto Scroll:Can be set between 1-6 sec. or disable. Default is 3s.
Backlight Timeout:Can be set between 1~5 min.
Runtime:This setting allows users to select what to display and not to display during the
runtime mode. Run time mode display setting is as following:
24
Item
Phase
Voltage
Line Voltage
Line Current
Setup
Voltage
Active Power
Apparent
Power
Reactive
Power
Power Factor
● Disable
● Enable
Power
Energy
Demand
Status
7.3 Report
7.3.1 Daily Report
Every day at 00:00:00, date in today will move to yesterday and clear today’s record except energy
data will be accumulated.
7.3.2 Diagnostic
In this section, only max/ min and when they happened in one month period has been stored. The
reset will then move this period data to last reset data and clear this period data except energy data.
25
z
This Period
Item
Setup
Current Time
Date:
Time:
Max/Min Va
Max/Min Vb
Max
Max/Min Vc
Date:
Max/Min Ia
Time:
Max/Min Ib
Max/Min Ic
Min
Max/Min KWa
Date:
Max/Min KWb
Time:
Max/Min KWc
Max/Min KVAa
Max/Min KVAb
Max/Min KVAc
Min
Min PFa
Date:
Min PFb
Time:
Min PFc
Max VaTHD
Max
Max VbTHD
Date:
Max VcTHD
Time:
Max IaTHD
Max IbTHD
Max IcTHD
Max Demand
z
Last Reset
Item
Current Time
Max/Min Va
Max/Min Vb
Max/Min Vc
Max/Min Ia
Max/Min Ib
Max/Min Ic
Max/Min KWa
Max/Min KWb
Max/Min KWc
Max/Min KVAa
Max/Min KVAb
Max/Min KVAc
Min PFa
Min PFb
Min PFc
Max VaTHD
Max VbTHD
Max VcTHD
Max IaTHD
Max IbTHD
Max IcTHD
Max Demand
Energy
Setup
Date:
Time:
Max
Date:
Time:
Min
Date:
Time:
Min
Date:
Time:
Max
Date:
Time:
del:
rec:
tot:
26
7.3.3 Harmonics
Item
Va Harmonics
Vb Harmonics
Vc Harmonics
Ia Harmonics
Ib Harmonics
Ic Harmonics
Report Chart
7.3.4 Current on alarm
If no current alarm is on, none will be shown. In this instrument up to eight items will be set to alarm
as following:
z
z
z
z
z
z
z
z
V Unbal Alarm
I Unbal Alarm
THD Alarm
Over V Alarm
Under V Alarm
Over I Alarm
I Loss Alarm
V Loss Alarm
7.3.5 Event log
In this event log section, up to 20 latest records has been recorded.
7.3.5.1 Sag Record
z
z
z
z
z
z
No:to select the sag record from 1 to 20 using efkeys
Cycle:sag cycles between 0-65535
Data:sag percentage between -327.67%-327.67%
Phase:A/B/C phase voltage
Begin:begin date and time
End:end date and time
27
7.3.5.2 Swell record
z
z
z
z
z
z
No:to select the swell record from 1 to 20 using efkeys
Cycle:swell cycles between 0-65535
Data:swell percentage between -327.67%-327.67%
Phase:A/B/C phase voltage
Begin:begin date and time
End:end date and time
7.3.5.3 Alarm Record
z
z
z
z
z
No:to select the alarm record from 1 to 20 using efkeys
Item:items can be current voltage…etc., as listed in the table of page 27
Data:percentage
Date:date of accruing
Time:time of accruing
7.3.5.4 Analog input
The AI option was originally setup by entering high value and low value to correspond 4-20mA input.
In this report reaction, users can observe the input data for each channel.
7.3.5.5 Nameplate Info
28
Chapter 8 Communication format
8.1 RS485
8.1.1 RS485 standard
PARAMETERS
Mode of Operation
Number of Drivers and Receives
Maximum cable length (meters)
Maximum data rate (baud)
Maximum common mode voltage (Volts)
Maximum Driver Output Levels (Loaded)
Maximum Driver Output Levels (Unloaded)
Drive Load (Ohms)
Driver Output short circuit Resistance (kohms)
Minimum receiver input Resistance (kohms)
Receiver sensitivity
Differential
32 Drivers / 32 Receivers
1200
10M
12 to -7
+/- 1.5
+/- 6
60 (min)
150 to Gnd, 250 to -7 or 12V
12
+/- 200mv
8.1.2 Wiring for instruments communication
RS485communication must use twisted paired wire, as show in the following program. “D+” connect
to one wire and “D-” to the other one
(Power meter)
Master
DD+
(Power meter)
Slave
D-
Slave
D+
D-
D+
(Power meter)
Slave
D-
D+
120 ohm
120 ohm
Cautions :
There must be no more than two wires connected to each terminal, this ensures that
a “Daisy Chain” or “Straight Line” configuration is used. A “star” or a network with
“Stubs(Tees)” is not recommended as reflections within the cable may result in data
corruption。
29
8.2 Modbus
In the start of modus communication, master will issue a “Query” to the slave. Every slaves will
monitor the “Query” address, so as to “execute’ or give “response” when the address is right
8.2.1 Modbus Format
The Query-Response Cycle
Query message from Master
Device Address
Device Address
Function Code
Function Code
8 bit Data Bytes
8 bit Data Bytes
Error Check
Error Check
Response messages from Slave
8.3 Communication protocol
PD1000 uses Modus RTU as the communication protocol. The following shows Query and Response
format.
Query:
Slave
Address
Function
Code
Response:
Slave
Function
Address Code
Start
Address
(Hi)
Byte
Count
Start
Address
(Lo)
Data
(Hi)
Number
of Points
(Hi)
Data
(Lo)
30
Number
of Points
(Lo)
Error
Check
(Lo)
Error
Check
(Lo)
Error
Check
(Hi)
Error
Check
(Hi)
8.4
Detail Parameters
Modbus Module #1 Holding Register : Digital Output
Parameter name
Modbus
Register
Len
Data
Type
Range
Default
value
bit 0 : Digital Output 1
bit 1 : Digital Output 2
0
Digital Output
44097
Word
UInt
Digital_Output_Reserve
44098
Word
UInt
Units
Comment
Modbus Module #2 Holding Register : Setup Parameter
Parameter name
Modbus
Register
Len
Data
Type
0:
2:
4:
6:
Range
Default
value
Units
1200 , 1: 2400 ,
4800 , 3: 9600 ,
19200, 5:38400
57600
4
bps
Comm_485_BaudRate
44099
Word
UInt
Comm_485_Address
44100
Word
UInt
Comm_485_StopBit
44101
Word
UInt
Comm_485_Parity
Reserved
Ethernet_IP_0*
Ethernet_IP_1*
Ethernet_IP_2*
Ethernet_IP_3*
Ethernet_PortNo*
Subnet_Mask_0*
Subnet_Mask _1*
Subnet_Mask _2*
Subnet_Mask _3*
Gateway_0*
Gateway_1*
Gateway_2*
Gateway_3*
Mac_Address_1*
Mac_Address_2*
Mac_Address_3*
Mac_Address_4*
Mac_Address_5*
Mac_Address_6*
44102
44103
Word
Word
Hi B
Lo B
Hi B
Lo B
Word
Hi B
Lo B
Hi B
Lo B
Hi B
Lo B
Hi B
Lo B
Hi B
Lo B
Hi B
Lo B
Hi B
Lo B
UInt
UInt
Byte
Byte
Byte
Byte
UInt
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
1-255
0:1 Stop bit,
1:2 Stop bit
0:No, 1:Even, 2:Odd
0
0-255
0-255
0-255
0-255
0:502, 1:503
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-ffh
0-ffh
0-ffh
0-ffh
0-ffh
0-ffh
Hi B
Byte
Volts Mode at present
Lo B
Byte
0
1
2
3
4
5
DWord
Float
60-600000
110
Volts
Word
Word
Word
Word
Word
UInt
UInt
UInt
UInt
UInt
1-600
1-5000
1-5
0:50Hz, 1:60Hz
0:Block, 1:Rolling
110
1
1
1
0
Volts
Amp.
Amp.
44122
Word
UInt
1,2,3,4,5,6,10
44123
Word
UInt
1,2,3,4,5,6,10,12,15,2
0,30,60
DWord
Uint32
Volts_Mode
PT_Primary
PT_Secondary
CT_Primary
CT_Secondary
Frequency*
Demand_Mode*
Number_of_Subinterval
*
Demand_Subinterval_
Length*
44104
44105
44106
44107
44108
44109
44110
44111
44112
44113
44114
4411544116
44117
44118
44119
44120
44121
Alarm_Enable
4412444125
4412644127
44128
SAG_Limit
44129
Password
Reserved
:
:
:
:
:
:
1P2W ,
1P3W ,
3P3W_Delta 2CT,
3P3W_Delta 3CT,
3P4W_Wye ,
Auto
0xxxxxxxh
Comment
15
0
0
0
192
168
1
210
0
255
255
255
0
0
0
0
0
00
18
D8
0
0
0
5
1
15
Min
0000000
Word
Word
UInt
0 : disable , 1 : enable
Word
UInt
Range : 80% - 100%
31
0
100
%
For Sag &
UnderVoltag
SWELL_Limit
44130
Word
UInt
Range : 100% - 120%
100
%
Reference_Primary_Volt
age
44131
44132
DWord
Float
60-600000
110
Volts
Voltage_Unbal_Limit
44133
Word
UInt
Range : 0% - 10%
10
%
Current_Unbal_Limit
44134
Word
UInt
Range : 0% - 10%
10
%
THD_Limit*
44135
Word
UInt
Range : 0% - 50%
50
%
Over_Current_Phase_Li
mit
44136
Word
UInt
0-9999
9999
Amp.
Over_Current_Neutral
_Limit
44137
Word
UInt
0-9999
9999
Amp.
Current_Loss_Limit
44138
Word
UInt
0-5000
0
Amp.
Voltage_Loss_Limit
4413944140
DWord
Float
0-600000
0
Volts
Voltage_Unbal_Clear
44141
Word
UInt
Range : 0% - 10%
1
%
Current_Unbal_ Clear
44142
Word
UInt
Range : 0% - 10%
1
%
THD_ Clear
44143
Word
UInt
Range : 0% - 50%
1
%
Over_Current_Phase_
Clear
44144
Word
UInt
0-9999
0
Amp.
Over_Current_Neutral _
Clear
44145
Word
UInt
0-9999
0
Amp.
Current_Loss_ Clear
44146
Word
UInt
0-5000
0
Amp.
Voltage_Loss_ Clear
4414744148
DWord
Float
0-600000
0
Volts
Word
Uint
0 : None
1 : Voltage unbalance
alarm
2 : Current unbalance
alarm
3 : THD alarm*
4 : Over Voltage alarm
5 : Under Voltage
alarm
6 : Over Current alarm
7 : Current Loss alarm
8 : Voltage Loss alarm
0
Hi B
Byte
0 : None , 1 : kWh
2 : kvarh , 3 : kVAh
0
Lo B
Byte
0 : 1Wh/pulse ,
1 : 10Wh/pulse
0
Hi B
Byte
0 : None , 1 : A phase ,
2 : B phase , 3 : C
phase , 4 : Total
0
DO1_Select_Item
44149
DO2_Select_Item
44150
DO2_Select_Kh
AO1_Select_Phase
44151
32
e alarm
For Swell &
OverVoltage
alarm
For
Sag/Swell &
Under/Over
Voltage
For Voltage
unbalance
alarm
For Current
unbalance
alarm
For THD
alarm
For Over
Current
Phase alarm
For Over
Current
Neutral
alarm
For Phase
Loss-Current
alarm
For Phase
Loss-Voltage
alarm
For Voltage
unbalance
alarm clear
For Current
unbalance
alarm clear
For THD
alarm clear
For Over
Current
Phase alarm
clear
For Over
Current
Neutral
alarm clear
For Phase
Loss-Current
alarm clear
For Phase
Loss-Voltage
alarm clear
AO1_Select_ Item
Lo B
Byte
0 : V , 1 : I , 2 : KW ,
3 : Kvar , 4 : KVA
0
AO2_Select_Phase
Hi B
Byte
0 : None , 1 : A phase ,
2 : B phase , 3 : C 相 ,
4 : Total
0
AO2_Select_ Item
Lo B
Byte
0 : V , 1 : I , 2 : kW ,
3 : kvar , 4 : kVA
0
AO3_Select_Phase
Hi B
Byte
0 : None , 1 : A phase ,
2 : B phase , 3 : C
phase , 4 : Total
0
AO3_Select_ Item
Lo B
Byte
0 : V , 1 : I , 2 : kW ,
3 : kvar , 4 : kVA
0
AO4_Select_Phase
Hi B
Byte
0 : None , 1 : A phase ,
2 : B phase , 3 : C
phase , 4 : Total
0
Lo B
Byte
0 : V , 1 : I , 2 : kW ,
3 : kvar , 4 : kVA
0
Word
Hi B
Lo B
UInt
Byte
Byte
Word
UInt
Hi B
Lo B
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Byte
Byte
UInt
UInt
UInt
UInt
UInt
UInt
UInt
UInt
UInt
UInt
UInt
UInt
UInt
UInt
UInt
44152
44153
44154
AO4_Select_ Item
Reserved
Display_Auto_Scroll
Display_BK_Timeout
Runtime_Screen_Set
Reset_Mode*
Reset_Date*
Reserved
AI1_Eng_High
AI1_Eng_Low
AI2_Eng_High
AI2_Eng_Low
AI3_Eng_High
AI3_Eng_Low
AI4_Eng_High
AI4_Eng_Low
Reserved
Reserved
AO1_Set_Value
AO2_Set_Value
AO3_Set_Value
AO4_Set_Value
44155
44156
44157
44158
44159
44160
44161
44162
44163
44164
44165
44166
44167
44168
44169
44170
44171
44172
44173
0 - 6 sec
1 - 5 min
Bit=0 : Disable
Bit=1 : Enable
bit 0 : Phase Voltage
bit 1 : Line Voltage
bit 2 : Line Current
bit 3 : Active Power
bit 4 : Apparent Power
bit 5 : Reactive Power
bit 6 : Power Factor
bit 7 : Energy
bit 8 : Demand*
bit 9 : Status
0:Manual, 1:Auto
1~31
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0~65535
0
3
1
3ff
0
1
0
65535
0
65535
0
65535
0
65535
0
0
0
0
0
0
0
Modbus Module #3 Holding Register : Realtime Clock
Parameter name
Year
Month
Date
Hour
Min
Second
Modbus
Register
44177
44178
44179
44180
44181
44182
Len
Word
Word
Word
Word
Word
Word
Data
Type
BCD
BCD
BCD
BCD
BCD
BCD
Range
Default
value
Units
Comment
Modbus Module #4 Holding Register : Clear Function
Parameter name
Reset_ Daily
Reset_ Energy
Reset _Sag _Record
Reset_Swell_Record
Reset_Sag_Swell_Record
Modbus
Register
44193
44194
44195
44196
44197
Len
Word
Word
Word
Word
Word
Data
Type
UInt
Uint
Uint
Uint
Uint
Range
0x5aa5
0x5aa5
0x5aa5
0x5aa5
0x5aa5
33
Default
value
0
0
0
0
0
Units
Comment
0x5aa5:
0x5aa5:
0x5aa5:
0x5aa5:
0x5aa5:
clear
clear
clear
clear
clear
Reset_Alarm_Record
Reset_to_Default
Reset_All
Reset_Demand
Period_Reset
44198
44199
44200
44201
44202
Word
Word
Word
Word
Word
Uint
Uint
Uint
Uint
Uint
0x5aa5
0x5aa5
0x5aa5
0x5aa5
0x5aa5
0
0
0
0
0
0x5aa5:
0x5aa5:
0x5aa5:
0x5aa5:
0x5aa5:
clear
clear
clear
clear
clear
Modbus Module #5 Holding Register : Alarm Counter
Parameter name
Modbus
Register
Len
Data
Type
Range
Alarm_New_Counter
44209
Word
Uint
0-20
Sag_New_Counter
44210
Word
Uint
0-20
Swell_New_Counter
44211
Word
Uint
0-20
Alarm_Total_Counter
44212
Word
Uint
0-20
Sag_Total_Counter
44213
Word
Uint
0-20
Swell_Total_Counter
44214
Word
Uint
0-20
Default
value
Units
Comment
Counter number new after last
reading (up to 20 data)
Counter number new after last
reading (up to 20 data)
Counter number new after last
reading (up to 20 data)
Current total accumulates(up
to 20 data)
Current total accumulates(up
to 20 data)
Current total accumulates(up
to 20 data)
Modbus Module #6 Input Register : Digital Output
Parameter name
Modbus
Register
Len
Data
Type
Range
Default
value
bit 0 : Digital Output 1
bit 1 : Digital Output 2
0
Digital Output
34097
Word
UInt
Digital_Output_Reserve
34098
Word
UInt
Units
Comment
Units
Comment
Modbus Module #7 Input Register : Digital Intput
Parameter name
Modbus
Register
Len
Data
Type
Digital Input
34099
Word
UInt
Digital_Input_Reserve
34100
Word
UInt
Default
value
Range
bit
bit
bit
bit
bit
bit
bit
bit
bit
bit
bit
bit
0 : Digital Input 1
1 : Digital Input 2
2 : Digital Input 3
3 : Digital Input 4
4 : Digital Input 5
5 : Digital Input 6
6 : Digital Input 7
7 : Digital Input 8
8 : Digital Input 9
9 : Digital Input 10
10 : Digital Input 11
11 : Digital Input 12
Modbus Module #8 Input Register : Alarm Counter
Parameter name
Modbus
Register
Len
Data
Type
Range
Alarm_New_Counter
34101
Word
UInt
0-20
Sag_New_Counter
34102
Word
UInt
0-20
Swell_New_Counter
34103
Word
UInt
0-20
Alarm_Total_Counter
34104
Word
UInt
0-20
Sag_Total_Counter
34105
Word
UInt
0-20
Swell_Total_Counter
34106
Word
UInt
0-20
Default
value
Units
Comment
Counter number new after last
reading (up to 20 data)
Counter number new after last
reading (up to 20 data)
Counter number new after last
reading (up to 20 data)
Current total accumulates(up
to 20 data)
Current total accumulates(up
to 20 data)
Current total accumulates(up
to 20 data)
Modbus Module #9 Input Register : Realtime Data Voltage, Current, Frequency
Parameter name
Vln_a
Modbus
Register
3410734108
Len
Data
Type
Range
DWord
Float
Primary Voltage
34
Default
value
Units
Comment
Volts
with Runtime
display
Vln_b
Vln_c
Vln_avg
Vll_ab
Vll_bc
Vll_ca
Vll_avg
I_a
I_b
I_c
I_avg
I_n
Freq
3410934110
3411134112
3411334114
3411534116
3411734118
3411934120
3412134122
3412334124
3412534126
3412734128
3412934130
3413134132
3413334134
DWord
Float
Primary Voltage
Volts
DWord
Float
Primary Voltage
Volts
DWord
Float
Primary Voltage
Volts
DWord
Float
Primary Voltage
Volts
DWord
Float
Primary Voltage
Volts
DWord
Float
Primary Voltage
Volts
DWord
Float
Primary Voltage
Volts
DWord
Float
Primary Current
Amp.
DWord
Float
Primary Current
Amp.
DWord
Float
Primary Current
Amp.
DWord
Float
Primary Current
Amp.
DWord
Float
Primary Current
Amp.
DWord
Float
Hz
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
Modbus Module #10 Input Register : Realtime Data Power Result
Parameter name
KW_a
KW_b
KW_c
KW_tot
KVAR_a
KVAR_b
KVAR_c
KVAR_tot
KVA_a
KVA_b
KVA_c
KVA_tot
Modbus
Register
3413534136
3413734138
3413934140
3414134142
3414334144
3414534146
3414734148
3414934150
3415134152
3415334154
3415534156
3415734158
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
Default
value
Units
Comment
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
Modbus Module #11 Input Register : Realtime Data Power Factor & Phase Angle
Parameter name
PF_signed_a
PF_signed_b
PF_signed_c
PF_signed_avg
PhaseAngle_V_a
PhaseAngle_V_b
Modbus
Register
3415934160
3416134162
3416334164
3416534166
3416734168
3416934170
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
Default
value
Units
Comment
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
35
PhaseAngle_V_c
PhaseAngle_I_a
PhaseAngle_I_b
PhaseAngle_I_c
Reserved
Reserved
Reserved
3417134172
3417334174
3417534176
3417734178
3417934180
3418134182
3418334184
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Modbus Module #12 Input Register : Realtime Data Energy
Parameter name
KWH_del
KWH_rec
KWH_tot
KWH_net
KVARH_del (+ lagging)
KVARH_rec (- leading)
KVARH_tot
KVARH_net
KVAH
Modbus
Register
3418534186
3418734188
3418934190
3419134192
3419334194
3419534196
3419734198
3419934200
3420134202
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
Default
value
Units
Comment
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
with Runtime
display
Modbus Module #13 Input Register : Realtime data Demand
Parameter name
Demand_KW
Demand_Remain_Time
Modbus
Register
3420334204
34205
Len
Data
Type
DWord
Float
Word
UInt
Range
Default
value
Units
Comment
sec
Modbus Module #14 Input Register : AI Result
Parameter name
Modbus
Register
Len
Data
Type
Range
AI1 Value
34206
Word
UInt
0~65535
AI2 Value
34207
Word
UInt
0~65535
AI3 Value
34208
Word
UInt
0~65535
AI4 Value
34209
Word
UInt
0~65535
Default
value
Units
Comment
Modbus Module #15 Input Register : Daily Report This Day Max/Min
Parameter name
KWH_del_DT
KWH_rec_DT
KWH_tot_DT
KW_tot_max_DT
KW_tot_max_DT_Year
Modbus
Register
3460934610
3461134612
3461334614
3461534616
34617
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Word
BCD
Range
00-99
36
Default
value
Units
Comment
KW_tot_max_DT_Month
KW_tot_max_DT_Date
KW_tot_max_DT_Hour
KW_tot_max_DT_Min
KW_tot_max_DT_Second
KW_tot_min_DT
KW_tot_min_DT_Year
KW_tot_min_DT_Month
KW_tot_min_DT_Date
KW_tot_min_DT_Hour
KW_tot_min_DT_Min
KW_tot_min_DT_Second
Vavg_max_DT
Vavg_max_DT_Year
Vavg_max_DT_Month
Vavg_max_DT_Date
Vavg_max_DT_Hour
Vavg_max_DT_Min
Vavg_max_DT_Second
Vavg_min_DT
Vavg_min_DT_Year
Vavg_min_DT_Month
Vavg_min_DT_Date
Vavg_min_DT_Hour
Vavg_min_DT_Min
Vavg_min_DT_Second
Iavg_max_DT
Iavg_max_DT_Year
Iavg_max_DT_Month
Iavg_max_DT_Date
Iavg_max_DT_Hour
Iavg_max_DT_Min
Iavg_max_DT_Second
Iavg_min_DT
Iavg_min_DT_Year
Iavg_min_DT_Month
Iavg_min_DT_Date
Iavg_min_DT_Hour
Iavg_min_DT_Min
Iavg_min_DT_Second
Demand_max_DT
Demand_max_DT_Year
Demand_max_DT_Month
Demand_max_DT_Date
Demand_max_DT_Hour
Demand_max_DT_Min
Demand_max_DT_Second
34618
34619
34620
34621
34622
3462334624
34625
34626
34627
34628
34629
34630
3463134632
34633
34634
34635
34636
34637
34638
3463934640
34641
34642
34643
34644
34645
34646
3464734648
34649
34650
34651
34652
34653
34654
3465534656
34657
34658
34659
34660
34661
34662
3466334664
34665
34666
34667
34668
34669
34670
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
Modbus Module #16 Input Register : Daily Report Yesterday Max/Min
Parameter name
KWH_del_DY
KWH_rec_DY
KWH_tot_DY
KW_tot_max_DY
KW_tot_max_DY_Year
KW_tot_max_DY_Month
KW_tot_max_DY_Date
KW_tot_max_DY_Hour
KW_tot_max_DY_Min
Modbus
Register
3467134672
3467334674
3467534676
3467734678
34679
34680
34681
34682
34683
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
Range
00-99
1-12
1-31
0-23
0-59
37
Default
value
Units
Comment
KW_tot_max_DY_Second
KW_tot_min_DY
KW_tot_min_DY_Year
KW_tot_min_DY_Month
KW_tot_min_DY_Date
KW_tot_min_DY_Hour
KW_tot_min_DY_Min
KW_tot_min_DY_Second
Vavg_max_DY
Vavg_max_DY_Year
Vavg_max_DY_Month
Vavg_max_DY_Date
Vavg_max_DY_Hour
Vavg_max_DY_Min
Vavg_max_DY_Second
Vavg_min_DY
Vavg_min_DY_Year
Vavg_min_DY_Month
Vavg_min_DY_Date
Vavg_min_DY_Hour
Vavg_min_DY_Min
Vavg_min_DY_Second
Iavg_max_DY
Iavg_max_DY_Year
Iavg_max_DY_Month
Iavg_max_DY_Date
Iavg_max_DY_Hour
Iavg_max_DY_Min
Iavg_max_DY_Second
Iavg_min_DY
Iavg_min_DY_Year
Iavg_min_DY_Month
Iavg_min_DY_Date
Iavg_min_DY_Hour
Iavg_min_DY_Min
Iavg_min_DY_Second
Demand_max_DY
Demand_max_DY_Year
Demand_max_DY_Month
Demand_max_DY_Date
Demand_max_DY_Hour
Demand_max_DY_Min
Demand_max_DY_Second
34684
3468534686
34687
34688
34689
34690
34691
34692
3469334694
34695
34696
34697
34698
34699
34700
3470134702
34703
34704
34705
34706
34707
34708
3470934710
34711
34712
34713
34714
34715
34716
3471734718
34719
34720
34721
34722
34723
34724
3472534726
34727
34728
34729
34730
34731
34732
Word
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
Modbus Module #17 Input Register : Diagnostic This Period Max/Min
Parameter name
Va_max_TP
Va_max_TP_Year
Va_max_TP_Month
Va_max_TP_Date
Va_max_TP_Hour
Va_max_TP_Min
Va_max_TP_Second
Va_min_TP
Va_min_TP_Year
Va_min_TP_Month
Va_min_TP_Date
Va_min_TP_Hour
Va_min_TP_Min
Va_min_TP_Second
Vb_max_TP
Modbus
Register
3473334734
34735
34736
34737
34738
34739
34740
3474134742
34743
34744
34745
34746
34747
34748
34749-
Len
Data
Type
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
DWord
BCD
BCD
BCD
BCD
BCD
BCD
Float
Range
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
38
Default
value
Units
Comment
Vb_max_TP_Year
Vb_max_TP_Month
Vb_max_TP_Date
Vb_max_TP_Hour
Vb_max_TP_Min
Vb_max_TP_Second
Vb_min_TP
Vb_min_TP_Year
Vb_min_TP_Month
Vb_min_TP_Date
Vb_min_TP_Hour
Vb_min_TP_Min
Vb_min_TP_Second
Vc_max_TP
Vc_max_TP_Year
Vc_max_TP_Month
Vc_max_TP_Date
Vc_max_TP_Hour
Vc_max_TP_Min
Vc_max_TP_Second
Vc_min_TP
Vc_min_TP_Year
Vc_min_TP_Month
Vc_min_TP_Date
Vc_min_TP_Hour
Vc_min_TP_Min
Vc_min_TP_Second
Ia_max_TP
Ia_max_TP_Year
Ia_max_TP_Month
Ia_max_TP_Date
Ia_max_TP_Hour
Ia_max_TP_Min
Ia_max_TP_Second
Ia_min_TP
Ia_min_TP_Year
Ia_min_TP_Month
Ia_min_TP_Date
Ia_min_TP_Hour
Ia_min_TP_Min
Ia_min_TP_Second
Ib_max_TP
Ib_max_TP_Year
Ib_max_TP_Month
Ib_max_TP_Date
Ib_max_TP_Hour
Ib_max_TP_Min
Ib_max_TP_Second
Ib_min_TP
Ib_min_TP_Year
Ib_min_TP_Month
Ib_min_TP_Date
Ib_min_TP_Hour
Ib_min_TP_Min
Ib_min_TP_Second
Ic_max_TP
Ic_max_TP_Year
Ic_max_TP_Month
Ic_max_TP_Date
Ic_max_TP_Hour
Ic_max_TP_Min
Ic_max_TP_Second
34750
34751
34752
34753
34754
34755
34756
3475734758
34759
34760
34761
34762
34763
34764
3476534766
34767
34768
34769
34770
34771
34772
3477334774
34775
34776
34777
34778
34779
34780
3478134782
34783
34784
34785
34786
34787
34788
3478934790
34791
34792
34793
34794
34795
34796
3479734798
34799
34800
34801
34802
34803
34804
3480534806
34807
34808
34809
34810
34811
34812
3481334814
34815
34816
34817
34818
34819
34820
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
39
Ic_min_TP
Ic_min_TP_Year
Ic_min_TP_Month
Ic_min_TP_Date
Ic_min_TP_Hour
Ic_min_TP_Min
Ic_min_TP_Second
KWa_max_TP
KWa_max_TP_Year
KWa_max_TP_Month
KWa_max_TP_Date
KWa_max_TP_Hour
KWa_max_TP_Min
KWa_max_TP_Second
KWa_min_TP
KWa_min_TP_Date
KWa_min_TP_Month
KWa_min_TP_Date
KWa_min_TP_Hour
KWa_min_TP_Min
KWa_min_TP_Second
KWb_max_TP
KWb_max_TP_Year
KWb_max_TP_Month
KWb_max_TP_Date
KWb_max_TP_Hour
KWb_max_TP_Min
KWb_max_TP_Second
KWb_min_TP
KWb_min_TP_Year
KWb_min_TP_Month
KWb_min_TP_Date
KWb_min_TP_Hour
KWb_min_TP_Min
KWb_min_TP_Second
KWc_max_TP
KWc_max_TP_Year
KWc_max_TP_Month
KWc_max_TP_Date
KWc_max_TP_Hour
KWc_max_TP_Min
KWc_max_TP_Second
KWc_min_TP
KWc_min_TP_Year
KWc_min_TP_Month
KWc_min_TP_Date
KWc_min_TP_Hour
KWc_min_TP_Min
KWc_min_TP_Second
KVAa_max_TP
KVAa_max_TP_Year
KVAa_max_TP_Month
KVAa_max_TP_Date
KVAa_max_TP_Hour
KVAa_max_TP_Min
KVAa_max_TP_Second
KVAa_min_TP
KVAa_min_TP_Year
KVAa_min_TP_Month
KVAa_min_TP_Date
KVAa_min_TP_Hour
KVAa_min_TP_Min
3482134822
34823
34824
34825
34826
34827
34828
3482934830
34831
34832
34833
34834
34835
34836
3483734838
34839
34840
34841
34842
34843
34844
3484534846
34847
34848
34849
34850
34851
34852
3485334854
34855
34856
34857
34858
34859
34860
3486134862
34863
34864
34865
34866
34867
34868
3486934870
34871
34872
34873
34874
34875
34876
3487734878
34879
34880
34881
34882
34883
34884
3488534886
34887
34888
34889
34890
34891
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
40
KVAa_min_TP_Second
KVAb_max_TP
KVAb_max_TP_Year
KVAb_max_TP_Month
KVAb_max_TP_Date
KVAb_max_TP_Hour
KVAb_max_TP_Min
KVAb_max_TP_Second
KVAb_min_TP
KVAb_min_TP_Year
KVAb_min_TP_Month
KVAb_min_TP_Date
KVAb_min_TP_Hour
KVAb_min_TP_Min
KVAb_min_TP_Second
KVAc_max_TP
KVAc_max_TP_Year
KVAc_max_TP_Month
KVAc_max_TP_Date
KVAc_max_TP_Hour
KVAc_max_TP_Min
KVAc_max_TP_Second
KVAc_min_TP
KVAc_min_TP_Year
KVAc_min_TP_Month
KVAc_min_TP_Date
KVAc_min_TP_Hour
KVAc_min_TP_Min
KVAc_min_TP_Second
PFa_min_TP
PFa_min_TP_Year
PFa_min_TP_Month
PFa_min_TP_Date
PFa_min_TP_Hour
PFa_min_TP_Min
PFa_min_TP_Second
PFb_min_TP
PFb_min_TP_Year
PFb_min_TP_Month
PFb_min_TP_Date
PFb_min_TP_Hour
PFb_min_TP_Min
PFb_min_TP_Second
PFc_min_TP
PFc_min_TP_Year
PFc_min_TP_Month
PFc_min_TP_Date
PFc_min_TP_Hour
PFc_min_TP_Min
PFc_min_TP_Second
VaTHD_max_TP
VaTHD_max_TP_Year
VaTHD_max_TP_Month
VaTHD_max_TP_Date
VaTHD_max_TP_Hour
VaTHD_max_TP_Min
VaTHD_max_TP_Second
VbTHD_max_TP
VbTHD_max_TP_Year
VbTHD_max_TP_Month
VbTHD_max_TP_Date
VbTHD_max_TP_Hour
34892
3489334894
34895
34896
34897
34898
34899
34900
3490134902
34903
34904
34905
34906
34907
34908
3490934910
34911
34912
34913
34914
34915
34916
3491734918
34919
34920
34921
34922
34923
34924
3492534926
34927
34928
34928
34930
34931
34932
3493334934
34935
34935
34937
34938
34939
34940
3494134942
34943
34944
34945
34946
34947
34948
3494934950
34951
34952
34953
34954
34955
34956
3495734958
34959
34960
34961
34962
Word
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
BCD
BCD
BCD
BCD
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
41
VbTHD_max_TP_Min
VbTHD_max_TP_Second
VcTHD_max_TP
VcTHD_max_TP_Year
VcTHD_max_TP_Month
VcTHD_max_TP_Date
VcTHD_max_TP_Hour
VcTHD_max_TP_Min
VcTHD_max_TP_Second
IaTHD_max_TP
IaTHD_max_TP_Year
IaTHD_max_TP_Month
IaTHD_max_TP_Date
IaTHD_max_TP_Hour
IaTHD_max_TP_Min
IaTHD_max_TP_Second
IbTHD_max_TP
IbTHD_max_TP_Year
IbTHD_max_TP_Month
IbTHD_max_TP_Date
IbTHD_max_TP_Hour
IbTHD_max_TP_Min
IbTHD_max_TP_Second
IcTHD_max_TP
IcTHD_max_TP_Year
IcTHD_max_TP_Month
IcTHD_max_TP_Date
IcTHD_max_TP_Hour
IcTHD_max_TP_Min
IcTHD_max_TP_Second
Demand_max_TP
Demand_max_TP_Year
Demand_max_TP_Month
Demand_max_TP_Date
Demand_max_TP_Hour
Demand_max_TP_Min
Demand_max_TP_Second
34963
34964
3496534966
34967
34968
34969
34970
34971
34972
3497334974
34975
34976
34977
34978
34979
34980
3498134982
34983
34984
34985
34986
34987
34988
3498934990
34991
34992
34993
34994
34995
34996
3499734998
34999
35000
35001
35002
35003
35004
Word
Word
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
2000-2099
1-12
1-31
0-23
0-59
0-59
Modbus Module #18 Input Register : Diagnostic Last Reset Max/Min
Parameter name
LR_Year
LR_Month
LR_Date
LR_Hour
LR_Min
LR_Second
Va_max_LR
Va_max_LR_Year
Va_max_LR_Month
Va_max_LR_Date
Va_max_LR_Hour
Va_max_LR_Min
Va_max_LR_Second
Va_min_LR
Va_min_LR_Year
Va_min_LR_Month
Va_min_LR_Date
Va_min_LR_Hour
Va_min_LR_Min
Va_min_LR_Second
Vb_max_LR
Modbus
Register
35005
35006
35007
35008
3509
35010
3501135012
35013
35014
35015
35016
35017
35018
3501935020
35021
35022
35023
35024
35025
35026
3502735028
Word
Word
Word
Word
Word
Word
Data
Type
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Len
Range
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
42
Default
value
Units
Comment
Vb_max_LR_Year
Vb_max_LR_Month
Vb_max_LR_Date
Vb_max_LR_Hour
Vb_max_LR_Min
Vb_max_LR_Second
Vb_min_LR
Vb_min_LR_Year
Vb_min_LR_Month
Vb_min_LR_Date
Vb_min_LR_Hour
Vb_min_LR_Min
Vb_min_LR_Second
Vc_max_LR
Vc_max_LR_Year
Vc_max_LR_Month
Vc_max_LR_Date
Vc_max_LR_Hour
Vc_max_LR_Min
Vc_max_LR_Second
Vc_min_LR
Vc_min_LR_Year
Vc_min_LR_Month
Vc_min_LR_Date
Vc_min_LR_Hour
Vc_min_LR_Min
Vc_min_LR_Second
Ia_max_LR
Ia_max_LR_Year
Ia_max_LR_Month
Ia_max_LR_Date
Ia_max_LR_Hour
Ia_max_LR_Min
Ia_max_LR_Second
Ia_min_LR
Ia_min_LR_Year
Ia_min_LR_Month
Ia_min_LR_Date
Ia_min_LR_Hour
Ia_min_LR_Min
Ia_min_LR_Second
Ib_max_LR
Ib_max_LR_Year
Ib_max_LR_Month
Ib_max_LR_Date
Ib_max_LR_Hour
Ib_max_LR_Min
Ib_max_LR_Second
Ib_min_LR
Ib_min_LR_Year
Ib_min_LR_Month
Ib_min_LR_Date
Ib_min_LR_Hour
Ib_min_LR_Min
Ib_min_LR_Second
Ic_max_LR
Ic_max_LR_Year
Ic_max_LR_Month
Ic_max_LR_Date
Ic_max_LR_Hour
Ic_max_LR_Min
Ic_max_LR_Second
Ic_min_LR
35029
35030
35031
35032
35033
35034
3503535036
35037
35038
35039
35040
35041
35042
3504335044
35045
35046
35047
35048
35049
35050
3505135052
35053
35054
35055
35056
35057
35058
3505935060
35061
35062
35063
35064
35065
35066
3506735068
35069
35070
35071
35072
35073
35074
3507535076
35077
35078
35079
35080
35081
35082
3508335084
35085
35086
35087
35088
35089
35090
3509135092
35093
35094
35095
35096
35097
35098
35099-
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
DWord
BCD
BCD
BCD
BCD
BCD
BCD
Float
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
43
Ic_min_LR_Year
Ic_min_LR_Month
Ic_min_LR_Date
Ic_min_LR_Hour
Ic_min_LR_Min
Ic_min_LR_Second
KWa_max_LR
KWa_max_LR_Year
KWa_max_LR_Month
KWa_max_LR_Date
KWa_max_LR_Hour
KWa_max_LR_Min
KWa_max_LR_Second
KWa_min_LR
KWa_min_LR_Date
KWa_min_LR_Month
KWa_min_LR_Date
KWa_min_LR_Hour
KWa_min_LR_Min
KWa_min_LR_Second
KWb_max_LR
KWb_max_LR_Year
KWb_max_LR_Month
KWb_max_LR_Date
KWb_max_LR_Hour
KWb_max_LR_Min
KWb_max_LR_Second
KWb_min_LR
KWb_min_LR_Year
KWb_min_LR_Month
KWb_min_LR_Date
KWb_min_LR_Hour
KWb_min_LR_Min
KWb_min_LR_Second
KWc_max_LR
KWc_max_LR_Year
KWc_max_LR_Month
KWc_max_LR_Date
KWc_max_LR_Hour
KWc_max_LR_Min
KWc_max_LR_Second
KWc_min_LR
KWc_min_LR_Year
KWc_min_LR_Month
KWc_min_LR_Date
KWc_min_LR_Hour
KWc_min_LR_Min
KWc_min_LR_Second
KVAa_max_LR
KVAa_max_LR_Year
KVAa_max_LR_Month
KVAa_max_LR_Date
KVAa_max_LR_Hour
KVAa_max_LR_Min
KVAa_max_LR_Second
KVAa_min_LR
KVAa_min_LR_Year
KVAa_min_LR_Month
KVAa_min_LR_Date
KVAa_min_LR_Hour
KVAa_min_LR_Min
KVAa_min_LR_Second
35100
35101
35102
35103
35104
35105
35106
3510735108
35109
35110
35111
35112
35113
35114
3511535116
35117
35118
35119
35120
35121
35122
3512335124
35125
35126
35127
35128
35129
35130
3513135132
35133
35134
35135
35136
35137
35138
3513935140
35141
35142
35143
35144
35145
35146
3514735148
35149
35150
35151
35152
35153
35154
3515535156
35157
35158
35159
35160
35161
35162
3516335164
35165
35166
35167
35168
35169
35170
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
44
KVAb_max_LR
KVAb_max_LR_Year
KVAb_max_LR_Month
KVAb_max_LR_Date
KVAb_max_LR_Hour
KVAb_max_LR_Min
KVAb_max_LR_Second
KVAb_min_LR
KVAb_min_LR_Year
KVAb_min_LR_Month
KVAb_min_LR_Date
KVAb_min_LR_Hour
KVAb_min_LR_Min
KVAb_min_LR_Second
KVAc_max_LR
KVAc_max_LR_Year
KVAc_max_LR_Month
KVAc_max_LR_Date
KVAc_max_LR_Hour
KVAc_max_LR_Min
KVAc_max_LR_Second
KVAc_min_LR
KVAc_min_LR_Year
KVAc_min_LR_Month
KVAc_min_LR_Date
KVAc_min_LR_Hour
KVAc_min_LR_Min
KVAc_min_LR_Second
PFa_min_LR
PFa_min_LR_Year
PFa_min_LR_Month
PFa_min_LR_Date
PFa_min_LR_Hour
PFa_min_LR_Min
PFa_min_LR_Second
PFb_min_LR
PFb_min_LR_Year
PFb_min_LR_Month
PFb_min_LR_Date
PFb_min_LR_Hour
PFb_min_LR_Min
PFb_min_LR_Second
PFc_min_LR
PFc_min_LR_Year
PFc_min_LR_Month
PFc_min_LR_Date
PFc_min_LR_Hour
PFc_min_LR_Min
PFc_min_LR_Second
VaTHD_max_LR
VaTHD_max_LR_Year
VaTHD_max_LR_Month
VaTHD_max_LR_Date
VaTHD_max_LR_Hour
VaTHD_max_LR_Min
VaTHD_max_LR_Second
VbTHD_max_LR
VbTHD_max_LR_Year
VbTHD_max_LR_Month
VbTHD_max_LR_Date
VbTHD_max_LR_Hour
VbTHD_max_LR_Min
3517135172
35173
35174
35175
35176
35177
35178
3517935180
35181
35182
35183
35184
35185
35186
3518735188
35189
35190
35191
35192
35193
35194
3519535196
35197
35198
35199
35200
35201
35202
3520335204
35205
35206
35207
35208
35209
35210
3521135212
35213
35214
35215
35216
35217
35218
3521935220
35221
35222
35223
35224
35225
35226
3522735228
35229
35230
35231
35232
35233
35234
3523535236
35237
35238
35239
35240
35241
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
45
VbTHD_max_LR_Second
VcTHD_max_LR
VcTHD_max_LR_Year
VcTHD_max_LR_Month
VcTHD_max_LR_Date
VcTHD_max_LR_Hour
VcTHD_max_LR_Min
VcTHD_max_LR_Second
IaTHD_max_LR
IaTHD_max_LR_Year
IaTHD_max_LR_Month
IaTHD_max_LR_Date
IaTHD_max_LR_Hour
IaTHD_max_LR_Min
IaTHD_max_LR_Second
IbTHD_max_LR
IbTHD_max_LR_Year
IbTHD_max_LR_Month
IbTHD_max_LR_Date
IbTHD_max_LR_Hour
IbTHD_max_LR_Min
IbTHD_max_LR_Second
IcTHD_max_LR
IcTHD_max_LR_Year
IcTHD_max_LR_Month
IcTHD_max_LR_Date
IcTHD_max_LR_Hour
IcTHD_max_LR_Min
IcTHD_max_LR_Second
Demand_max_LR
Demand_max_LR_Year
Demand_max_LR_Month
Demand_max_LR_Date
Demand_max_LR_Hour
Demand_max_LR_Min
Demand_max_LR_Second
KWH_del_LR
KWH_rec_LR
KWH_tot_LR
35242
3524335244
35245
35246
35247
35248
35249
35250
3525135252
35253
35254
35255
35256
35257
35258
3525935260
35261
35262
35263
35264
35265
35266
3526735268
35269
35270
35271
35272
35273
35274
3527535276
35277
35278
35279
35280
35281
35282
3528335284
3528535286
3528735288
Word
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
Word
Word
Word
Word
Word
Word
BCD
BCD
BCD
BCD
BCD
BCD
DWord
Float
DWord
Float
DWord
Float
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
00-99
1-12
1-31
0-23
0-59
0-59
2000-2099
1-12
1-31
0-23
0-59
0-59
Modbus Module #19 Input Register : Event Log Sag Record
Sag01_Duration_Cycles
Modbus
Register
35289
Word
Data
Type
UINT
Sag01_Data
35290
Word
INT
Sag01_Phase
35291
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Parameter name
Sag01_Start_Time
3529235297
Len
Sag01_End_Time
3529835303
Word x 6
Date &
Time
(BCD)
Sag02_Duration_Cycles
Sag02_Data
35304
35305
Word
Word
UINT
INT
Range
Range : -327.68%
~ 327.67%
0: A 相 1: B 相 2: C
相
Range : -327.68%
46
Default
value
Units
Comment
Sag02_Phase
Sag02_Start_time
35306
3530735312
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag02_End_time
3531335318
Word x 6
Date &
Time
(BCD)
Sag03_Duration_Cycles
35319
Word
UINT
Sag03_Data
35320
Word
INT
Sag03_Phase
35321
Word
UINT
Sag03_Start_time
3532235327
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag03_End_time
3532835333
Word x 6
Sag04_Duration_Cycles
35334
Word
UINT
Sag04_Data
35335
Word
INT
Sag04_Phase
35336
Word
UINT
Sag04_Start_time
3533735342
Word x 6
Date &
Time
(BCD)
Sag04_End_time
3534335348
Word x 6
Date &
Time
(BCD)
Sag05_Duration_Cycles
35349
Word
UINT
Sag05_Data
35350
Word
INT
Sag05_Phase
35351
Word
UINT
3535235357
Range : -327.68%
~ 327.67%
0: A 相 1: B 相 2: C
相
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Date &
Time
(BCD)
Sag05_Start_time
~ 327.67%
0: A 相 1: B 相 2: C
相
Word x 6
Range : -327.68%
~ 327.67%
0: A 相 1: B 相 2: C
相
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range : -327.68%
~ 327.67%
0: A 相 1: B 相 2: C
相
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag05_End_time
3535835363
Word x 6
Date &
Time
(BCD)
Sag06_Duration_Cycles
35364
Word
UINT
Sag06_Data
35365
Word
INT
Sag06_Phase
35366
Word
UINT
Range : -327.68%
~ 327.67%
0: A 相 1: B 相 2: C
47
相
Sag06_Start_time
3536735372
Word x 6
Date &
Time
(BCD)
Sag06_End_time
3537335378
Word x 6
Date &
Time
(BCD)
Sag07_Duration_Cycles
35379
Word
UINT
Sag07_Data
35380
Word
INT
Sag07_Phase
35381
Word
UINT
Sag07_Start_time
3538235387
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
3538835393
Word x 6
Date &
Time
(BCD)
Sag08_Duration_Cycles
35394
Word
UINT
Sag08_Data
35385
Word
INT
Sag08_Phase
35396
Word
UINT
Sag08_End_time
3539735402
3540335408
Date &
Time
(BCD)
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Word x 6
35409
Word
UINT
Sag09_Data
35410
Word
INT
Sag09_Phase
35411
Word
UINT
Sag09_End_time
3541235417
3541835423
Range : -327.68%
~ 327.67%
0: A 相 1: B 相 2: C
相
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag09_Duration_Cycles
Sag09_Start_time
Range : -327.68%
~ 327.67%
0: A 相 1: B 相 2: C
相
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag07_End_time
Sag08_Start_time
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range : -327.68%
~ 327.67%
0: A 相 1: B 相 2: C
相
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Word x 6
Sag10_Duration_Cycles
35424
Word
UINT
Sag10_Data
35425
Word
INT
Sag10_Phase
35426
Word
UINT
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
48
Sag10_Start_time
3542735432
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag10_End_time
3543335438
Word x 6
Date &
Time
(BCD)
Sag11_Duration_Cycles
35439
Word
UINT
Sag11_Data
35440
Word
INT
Sag11_Phase
35441
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag11_Start_time
3544235447
Sag11_End_time
3544835453
Word x 6
Date &
Time
(BCD)
Sag12_Duration_Cycles
35454
Word
UINT
Sag12_Data
35455
Word
INT
Sag12_Phase
35456
Word
UINT
Sag12_Start_time
3545735462
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag12_End_time
3546335468
Word x 6
Sag13_Duration_Cycles
35469
Word
UINT
Sag13_Data
35470
Word
INT
Sag13_Phase
35471
Word
UINT
3547235477
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Date &
Time
(BCD)
Sag13_Start_time
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag13_End_time
3547835483
Word x 6
Date &
Time
(BCD)
Sag14_Duration_Cycles
35484
Word
UINT
Sag14_Data
35485
Word
INT
Range : -327.68%
~ 327.67%
49
Sag14_Phase
Sag14_Start_time
35486
3548735492
0: A phase 1: B
phase 2: C phase
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag14_End_time
3549335498
Word x 6
Date &
Time
(BCD)
Sag15_Duration_Cycles
35499
Word
UINT
Sag15_Data
35500
Word
INT
Sag15_Phase
35501
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag15_Start_time
Sag15_End_time
3550235507
3550835513
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Sag16_Duration_Cycles
35514
Word
UINT
Sag16_Data
35515
Word
INT
Sag16_Phase
35516
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag16_Start_time
3551735522
Sag16_End_time
3552335528
Word x 6
Date &
Time
(BCD)
Sag17_Duration_Cycles
35529
Word
UINT
Sag17_Data
35530
Word
INT
Sag17_Phase
35531
Word
UINT
Sag17_Start_time
3553235537
Word x 6
Date &
Time
(BCD)
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
50
Sag17_End_time
3553835543
Word x 6
Date &
Time
(BCD)
Sag18_Duration_Cycles
35544
Word
UINT
Sag18_Data
35545
Word
INT
Sag18_Phase
35546
Word
UINT
Sag18_Start_time
Sag18_End_time
3554735552
3555335558
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag19_Duration_Cycles
35559
Word
UINT
Sag19_Data
35560
Word
INT
Sag19_Phase
35561
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Sag19_Start_time
3556235567
Sag19_End_time
3556835573
Word x 6
Date &
Time
(BCD)
Sag20_Duration_Cycles
35574
Word
UINT
Sag20_Data
35575
Word
INT
Sag20_Phase
35576
Word
UINT
Sag20_Start_time
Sag20_End_time
3557735582
3558335588
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Range : -327.68%
~ 327.67%
0: A phase 1: B
phase 2: C phase
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Modbus Module #20 Input Register : Event Log Swell Record
Swell01_Duration_Cycles
Modbus
Register
35589
Word
Data
Type
UINT
Swell01_Data
35590
Word
INT
Parameter name
Len
Range
Range :
-327.68% ~
51
Default
value
Units
Comment
Swell01_Phase
Swell01_Start_Time
35591
3559235597
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell01_End_Time
3559835603
Word x 6
Date &
Time
(BCD)
Swell02_Duration_Cycles
35604
Word
UINT
Swell02_Data
35605
Word
INT
Swell02_Phase
35606
Word
UINT
Swell02_Start_time
3560735612
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
3561335618
Word x 6
Date &
Time
(BCD)
Swell03_Duration_Cycles
35619
Word
UINT
Swell03_Data
35620
Word
INT
Swell03_Phase
35621
Word
UINT
3562235627
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell03_End_time
3562835633
Word x 6
Swell04_Duration_Cycles
35634
Word
UINT
Swell04_Data
35635
Word
INT
Swell04_Phase
35636
Word
UINT
Word x 6
Date &
Time
(BCD)
3563735642
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Date &
Time
(BCD)
Swell04_Start_time
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell02_End_time
Swell03_Start_time
327.67%
0: A phase 1: B
phase 2: C phase
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
52
Swell04_End_time
3564335648
Word x 6
Date &
Time
(BCD)
Swell05_Duration_Cycles
35649
Word
UINT
Swell05_Data
35650
Word
INT
Swell05_Phase
35651
Word
UINT
Swell05_Start_time
3565235657
Word x 6
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell05_End_time
3565835663
Word x 6
Date &
Time
(BCD)
Swell06_Duration_Cycles
35664
Word
UINT
Swell06_Data
35665
Word
INT
Swell06_Phase
35666
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell06_Start_time
3566735672
Swell06_End_time
3567335678
Word x 6
Date &
Time
(BCD)
Swell07_Duration_Cycles
35679
Word
UINT
Swell07_Data
35680
Word
INT
Swell07_Phase
35681
Word
UINT
Swell07_Start_time
3568235687
Word x 6
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell07_End_time
3568835693
Word x 6
Date &
Time
(BCD)
Swell08_Duration_Cycles
35694
Word
UINT
Swell08_Data
35695
Word
INT
Swell08_Phase
35696
Word
UINT
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
53
Swell08_Start_time
3569735702
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell08_End_time
3570335708
Word x 6
Date &
Time
(BCD)
Swell09_Duration_Cycles
35709
Word
UINT
Swell09_Data
35710
Word
INT
Swell09_Phase
35711
Word
UINT
Swell09_Start_time
3571235717
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell09_End_time
3571835723
Word x 6
Date &
Time
(BCD)
Swell10_Duration_Cycles
35724
Word
UINT
Swell10_Data
35725
Word
INT
Swell10_Phase
35726
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell10_Start_time
3572735732
Swell10_End_time
3573335738
Word x 6
Date &
Time
(BCD)
Swell11_Duration_Cycles
35739
Word
UINT
Swell11_Data
35740
Word
INT
Swell11_Phase
35741
Word
UINT
Swell11_Start_time
3574235747
Word x 6
Date &
Time
(BCD)
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
54
Swell11_End_time
3574835753
Word x 6
Date &
Time
(BCD)
Swell12_Duration_Cycles
35754
Word
UINT
Swell12_Data
35755
Word
INT
Swell12_Phase
35756
Word
UINT
Swell12_Start_time
3575735762
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell12_End_time
3576335768
Word x 6
Swell13_Duration_Cycles
35769
Word
UINT
Swell13_Data
35770
Word
INT
Swell13_Phase
35771
Word
UINT
3577235777
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell13_End_time
3577835783
Word x 6
Swell14_Duration_Cycles
35784
Word
UINT
Swell14_Data
35785
Word
INT
Swell14_Phase
35786
Word
UINT
3578735792
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Date &
Time
(BCD)
Swell14_Start_time
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Date &
Time
(BCD)
Swell13_Start_time
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Word x 6
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell14_End_time
3579335798
Word x 6
Date &
Time
(BCD)
Swell15_Duration_Cycles
35799
Word
UINT
Swell15_Data
35800
Word
INT
Swell15_Phase
35801
Word
UINT
Range :
-327.68% ~
327.67%
0: A phase 1: B
55
phase 2: C phase
Swell15_Start_time
3580235807
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell15_End_time
3580835813
Word x 6
Date &
Time
(BCD)
Swell16_Duration_Cycles
35814
Word
UINT
Swell16_Data
35815
Word
INT
Swell16_Phase
35816
Word
UINT
Swell16_Start_time
3581735822
Word x 6
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell16_End_time
3582335828
Word x 6
Date &
Time
(BCD)
Swell17_Duration_Cycles
35829
Word
UINT
Swell17_Data
35830
Word
INT
Swell17_Phase
35831
Word
UINT
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell17_Start_time
3583235837
Swell17_End_time
3583835843
Word x 6
Date &
Time
(BCD)
Swell18_Duration_Cycles
35844
Word
UINT
Swell18_Data
35845
Word
INT
Swell18_Phase
35846
Word
UINT
Swell18_Start_time
3584735852
Word x 6
Date &
Time
(BCD)
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
56
Swell18_End_time
3585335858
Word x 6
Date &
Time
(BCD)
Swell19_Duration_Cycles
35859
Word
UINT
Swell19_Data
35860
Word
INT
Swell19_Phase
35861
Word
UINT
Swell19_Start_time
3586235867
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
3586835873
Word x 6
Date &
Time
(BCD)
Swell20_Duration_Cycles
35874
Word
UINT
Swell20_Data
35875
Word
INT
Swell20_Phase
35876
Word
UINT
Swell20_End_time
3587735882
3588335888
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Swell19_End_time
Swell20_Start_time
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
0: A phase 1: B
phase 2: C phase
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Modbus Module #21 Input Register : Event Log Alarm Record
Alarm01_Item
Modbus
Register
35889
Word
Data
Type
UINT
Alarm01_Data
35890
Word
INT
Parameter name
Len
Alarm01_Time
3589135896
Word x 6
Date &
Time
(BCD)
Alarm02_Item
35897
Word
UINT
Alarm02_Data
35898
Word
INT
Range
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
57
Default
value
Units
Comment
Alarm02_Time
3589935904
Word x 6
Date &
Time
(BCD)
Alarm03_Item
35905
Word
UINT
Alarm03_Data
35906
Word
INT
Alarm03_Time
3590735912
Word x 6
Date &
Time
(BCD)
Alarm04_Item
35913
Word
UINT
Alarm04_Data
35914
Word
INT
Alarm04_Time
3591535920
Word x 6
Date &
Time
(BCD)
Alarm05_Item
35921
Word
UINT
Alarm05_Data
35922
Word
INT
Alarm05_Time
3592335928
Word x 6
Date &
Time
(BCD)
Alarm06_Item
35929
Word
UINT
Alarm06_Data
35930
Word
INT
Alarm06_Time
3593135936
Word x 6
Date &
Time
(BCD)
Alarm07_Item
35937
Word
UINT
Alarm07_Data
35938
Word
INT
Alarm07_Time
3593935944
Word x 6
Date &
Time
(BCD)
Alarm08_Item
35945
Word
UINT
Alarm08_Data
35946
Word
INT
Alarm08_Time
3594735952
Word x 6
Date &
Time
(BCD)
Alarm09_Item
35953
Word
UINT
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 2000-2099
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
58
Alarm09_Data
35954
Word
INT
Alarm09_Time
3595535960
Word x 6
Date &
Time
(BCD)
Alarm10_Item
35961
Word
UINT
Alarm10_Data
35962
Word
INT
Alarm10_Time
3596335968
Word x 6
Date &
Time
(BCD)
Alarm11_Item
35969
Word
UINT
Alarm11_Data
35970
Word
INT
Alarm11_Time
3597135976
Word x 6
Date &
Time
(BCD)
Alarm12_Item
35977
Word
UINT
Alarm12_Data
35978
Word
INT
Alarm12_Time
3597935984
Word x 6
Date &
Time
(BCD)
Alarm13_Item
35985
Word
UINT
Alarm13_Data
35986
Word
INT
Alarm13_Time
3598735992
Word x 6
Date &
Time
(BCD)
Alarm14_Item
35993
Word
UINT
Alarm14_Data
35994
Word
INT
Alarm14_Time
3599536000
Word x 6
Date &
Time
(BCD)
Alarm15_Item
36001
Word
UINT
Alarm15_Data
36002
Word
INT
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
59
Alarm15_Time
3600336008
Word x 6
Date &
Time
(BCD)
Alarm16_Item
36009
Word
UINT
Alarm16_Data
36010
Word
INT
Alarm16_Time
3601136016
Word x 6
Date &
Time
(BCD)
Alarm17_Item
36017
Word
UINT
Alarm17_Data
36018
Word
INT
Alarm17_Time
3601936024
Word x 6
Date &
Time
(BCD)
Alarm18_Item
36025
Word
UINT
Alarm18_Data
36026
Word
INT
Alarm18_Time
3602736032
Word x 6
Date &
Time
(BCD)
Alarm19_Item
36033
Word
UINT
Alarm19_Data
36034
Word
INT
Alarm19_Time
3603536040
Word x 6
Date &
Time
(BCD)
Alarm20_Item
36041
Word
UINT
Alarm20_Data
36042
Word
INT
Alarm20_Time
3604336048
Word x 6
Date &
Time
(BCD)
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Range :
-327.68% ~
327.67%
Year : 00-99
Month : 1-12
Date : 1-31
Hour : 0-23
Minute : 0-59
Second : 0-59
Modbus Module #22 Input Register : Total Harmonics
Parameter name
TOT_HD_V_a
TOT_HD_V_b
TOT_HD_V_c
TOT_HD_I_a
TOT_HD_I_b
Modbus
Register
3665736658
3665936660
3666136662
3666336664
36665-
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
60
Default
value
Units
Comment
TOT_HD_I_c
TOT_HD_I_n
36666
3666736668
3666936670
DWord
Float
DWord
Float
Modbus Module #23 Input Register : Total Odd & Even Harmonics
Parameter name
TOT_EVEN_HD_V_a
TOT_EVEN_HD_V_b
TOT_EVEN_HD_V_c
TOT_EVEN_HD_I_a
TOT_EVEN_HD_I_b
TOT_EVEN_HD_I_c
TOT_EVEN_HD_I_n
TOT_ODD_HD_V_a
TOT_ODD_HD_V_b
TOT_ODD_HD_V_c
TOT_ODD_HD_I_a
TOT_ODD_HD_I_b
TOT_ODD_HD_I_c
TOT_ODD_HD_I_n
Modbus
Register
3667136672
3667336674
3667536676
3667736678
3667936680
3668136682
3668336684
3668536686
3668736688
3668936690
3669136692
3669336694
3669536696
3669736698
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
Default
value
Units
Comment
Units
Comment
Modbus Module #24 Input Register : Phase A Voltage Harmonics
Parameter name
Reserved
HD1_V_a
HD2_V_a
HD3_V_a
HD4_V_a
HD5_V_a
HD6_V_a
HD7_V_a
HD8_V_a
HD9_V_a
HD10_V_a
HD11_V_a
HD12_V_a
HD13_V_a
HD14_V_a
Modbus
Register
3669936700
3670136702
3670336704
3670536706
3670736708
3670936710
3671136712
3671336714
3671536716
3671736718
3671936720
3672136722
3672336724
3672536726
36727-
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
61
Default
value
HD15_V_a
HD16_V_a
HD17_V_a
HD18_V_a
HD19_V_a
HD20_V_a
HD21_V_a
HD22_V_a
HD23_V_a
HD24_V_a
HD25_V_a
HD26_V_a
HD27_V_a
HD28_V_a
HD29_V_a
HD30_V_a
HD31_V_a
36728
3672936730
3673136732
3673336734
3673536736
3673736738
3673936740
3674136742
3674336744
3674536746
3674736748
3674936750
3675136752
3675336754
3675536756
3675736758
3675936760
3676136762
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Modbus Module #25 Input Register : Phase B Voltage Harmonics
Parameter name
Reserved
HD1_V_b
HD2_V_b
HD3_V_b
HD4_V_b
HD5_V_b
HD6_V_b
HD7_V_b
HD8_V_b
HD9_V_b
HD10_V_b
HD11_V_b
HD12_V_b
HD13_V_b
HD14_V_b
HD15_V_b
Modbus
Register
3676336764
3676536766
3676736768
3676936770
3677136772
3677336774
3677536776
3677736778
3677936780
3678136782
3678336784
3678536786
3678736788
3678936790
3679136792
3679336794
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
62
Default
value
Units
Comment
HD16_V_b
HD17_V_b
HD18_V_b
HD19_V_b
HD20_V_b
HD21_V_b
HD22_V_b
HD23_V_b
HD24_V_b
HD25_V_b
HD26_V_b
HD27_V_b
HD28_V_b
HD29_V_b
HD30_V_b
HD31_V_b
3679536796
3679736798
3679936800
3680136802
3680336804
3680536806
3680736808
3680936810
3681136812
3681336814
3681536816
3681736818
3681936820
3682136822
3682336824
3682536826
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Modbus Module #26 Input Register : Phase C Voltage Harmonics
Parameter name
Reserved
HD1_V_c
HD2_V_c
HD3_V_c
HD4_V_c
HD5_V_c
HD6_V_c
HD7_V_c
HD8_V_c
HD9_V_c
HD10_V_c
HD11_V_c
HD12_V_c
HD13_V_c
HD14_V_c
HD15_V_c
HD16_V_c
HD17_V_c
Modbus
Register
3682736828
3682936830
3683136832
3683336834
3683536836
3683736838
3683936840
3684136842
3684336844
3684536846
3684736848
3684936850
3685136852
368536854
3685536856
3685736858
3685936860
36861-
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
63
Default
value
Units
Comment
HD18_V_c
HD19_V_c
HD20_V_c
HD21_V_c
HD22_V_c
HD23_V_c
HD24_V_c
HD25_V_c
HD26_V_c
HD27_V_c
HD28_V_c
HD29_V_c
HD30_V_c
HD31_V_c
36862
3686336864
3686536866
3686736868
3686936870
3687136872
3687336874
3687536876
3687736878
3687936880
3688136882
3688336884
3688536886
3688736888
3688936890
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Modbus Module #27 Input Register : Phase A Current Harmonics
Parameter name
Reserved
HD1_I_a
HD2_I_a
HD3_I_a
HD4_I_a
HD5_I_a
HD6_I_a
HD7_I_a
HD8_I_a
HD9_I_a
HD10_I_a
HD11_I_a
HD12_I_a
HD13_I_a
HD14_I_a
HD15_I_a
HD16_I_a
HD17_I_a
HD18_I_a
Modbus
Register
3689136892
3689336894
3689536896
3689736898
3689936900
3690136902
3690336904
3690536906
3690736908
3690936910
3691136912
3691336914
3691536916
3691736918
3691936920
3692136922
3692336924
3692536926
3692736928
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
64
Default
value
Units
Comment
HD19_I_a
HD20_I_a
HD21_I_a
HD22_I_a
HD23_I_a
HD24_I_a
HD25_I_a
HD26_I_a
HD27_I_a
HD28_I_a
HD29_I_a
HD30_I_a
HD31_I_a
3692936930
3693136932
3693336934
3693536936
3693736938
3693936940
3694136942
3694336944
3694536946
3694736948
3694936950
3695136952
3695336954
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Modbus Module #28 Input Register : Phase B Current Harmonics
Parameter name
Reserved
HD1_I_b
HD2_I_b
HD3_I_b
HD4_I_b
HD5_I_b
HD6_I_b
HD7_I_b
HD8_I_b
HD9_I_b
HD10_I_b
HD11_I_b
HD12_I_b
HD13_I_b
HD14_I_b
HD15_I_b
HD16_I_b
HD17_I_b
HD18_I_b
HD19_I_b
HD20_I_b
Modbus
Register
3695536956
3695736958
3695936960
3696136962
3696336964
3696536966
3696736968
3696936970
3697136972
3697336974
3697536976
3697736978
3697936980
3698136982
3698336984
3698536986
3698736988
3698936990
3699136992
3699336994
36995-
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
65
Default
value
Units
Comment
HD21_I_b
HD22_I_b
HD23_I_b
HD24_I_b
HD25_I_b
HD26_I_b
HD27_I_b
HD28_I_b
HD29_I_b
HD30_I_b
HD31_I_b
36996
3699736998
3699937000
3700137002
3700337004
3700537006
3700737008
3700937010
3701137012
3701337014
3701537016
3701737018
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Modbus Module #29 Input Register : Phase C Current Harmonics
Parameter name
Reserved
HD1_I_c
HD2_I_c
HD3_I_c
HD4_I_c
HD5_I_c
HD6_I_c
HD7_I_c
HD8_I_c
HD9_I_c
HD10_I_c
HD11_I_c
HD12_I_c
HD13_I_c
HD14_I_c
HD15_I_c
HD16_I_c
HD17_I_c
HD18_I_c
HD19_I_c
HD20_I_c
HD21_I_c
Modbus
Register
3701937020
3702137022
3702337024
3702537026
3702737028
3702937030
3703137032
3703337034
3703537036
3703737038
3703937040
3704137042
3704337044
3704537046
3704737048
3704937050
3705137052
3705337054
3705537056
3705737058
3705937060
3706137062
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
66
Default
value
Units
Comment
HD22_I_c
HD23_I_c
HD24_I_c
HD25_I_c
HD26_I_c
HD27_I_c
HD28_I_c
HD29_I_c
HD30_I_c
HD31_I_c
3706337064
3706537066
3706737068
3707937070
3707137072
3707337074
3707537076
3707737078
3707937080
3708137082
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Modbus Module #30 Input Register : Neutral Current Harmonics
Parameter name
Reserved
HD1_I_n
HD2_I_n
HD3_I_n
HD4_I_n
HD5_I_n
HD6_I_n
HD7_I_n
HD8_I_n
HD9_I_n
HD10_I_n
HD11_I_n
HD12_I_n
HD13_I_n
HD14_I_n
HD15_I_n
HD16_I_n
HD17_I_n
HD18_I_n
HD19_I_n
HD20_I_n
HD21_I_n
HD22_I_n
HD23_I_n
Modbus
Register
3708337084
3708537086
3708737088
3708937090
3709137092
3709337094
3709537096
3709737098
3709937100
3710137102
37103
37104
3710537106
3710737108
3710937110
3711137112
3711337114
3711537116
3711737118
3711937120
3712137122
3712337124
3712537126
3712737128
37129-
Len
Data
Type
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
Range
67
Default
value
Units
Comment
HD24_I_n
HD25_I_n
HD26_I_n
HD27_I_n
HD28_I_n
HD29_I_n
HD30_I_n
HD31_I_n
37130
3713137132
3713337134
3713537136
3713737138
3713937140
3714137142
3714337144
3714537146
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
DWord
Float
68
Brainchild Electronic Co., Ltd.
No. 209, Chung Yang Road, Nan Kang Dist., Taipei, Taiwan
Tel: 886-2-27861299 Fax: 886-2-27861395 E-mail: [email protected]
Website: http://www.brainchild.com.tw
69