Download Goodman Technical Manual
Transcript
TECHNICAL MANU AL MANUAL ACNF, AWUF, ADPF, ARPF, ARUF, AEPF, ASPF ATUF Air Handlers • Refer to Service Manual RS6100004 & RS6200006 for installation, operation & troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2007-2012 Goodman Company, L.P. RT6121000r18 January 2012 PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. A W PRODUCT TYPE: A: Air Handler U F 3642 1 6 EXPANSION DEVICE: F: Flowrater T: TXV (Expansion Device) A MINOR REVISION* MAJOR REVISION* CABINET FINISH: U: Unpainted P: Painted N: Uncased APPLICATION C: Ceiling Mount PSC Motor D: Downflow PSC Motor E: Multi-Position Varible Speed Motor S: Energy-Efficient Motor R: Multi-Position PSC Motor T: Coated Coils W: Wall Mount PSC Motor A REFRIGERANT CHARGE: No Digit: R-22 Only 6: R-410A or R-22 ELECTRICAL: 1: 208-230V/1ph/60Hz NOMINAL CAPACITY RANGE: @ 13 SEER Dedicated Application 3636: 3 Tons Multi-Position & Downflow Applications 3137: 3 Tons 3642: 3 - 3 1/2 Tons 1830: 1 1/2 - 3 1/2 Tons @10 SEER 1729: 1 1/2 - 2 1/2 Tons (for export systems) Ceiling Mount & Wall Mount Applications (Nominal Cooling Capacity/Electric Heat kW) 1803: 1 1/2 Tons Cooling / 3 kW Electric Heat 1805: 1 1/2 Tons Cooling / 5 kW Electric Heat 2405: 2 Tons Cooling / 5 kW Electric Heat 3608: 3 Tons Cooling / 8 kW Electric Heat 3105: 1.5 - 2.5 Tons Cooling / 5kW Electric Heat 3210: 2 - 2.5 Tons Cooling / 10kW Electric Heat 3705: 3 Tons Cooling / 5 kW Electric Heat 3708: 3 Tons Cooling / 8 kW Electric Heat 3710: 3 Tons Cooling / 10 kW Electric Heat All Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-230v, 60 hz, 1 phase. WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. WARNING 2 Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician", at a minimum, as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WARNING PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. ACNF18001** ACNF18051** ACNF18061** ACNF18081** ACNF24001** ACNF24051** ACNF24061** ACNF24081** ACNF24101** ACNF30001** ACNF30051** ACNF30061** ACNF30081** ACNF30101** ACNF180016D* ACNF180516D* ACNF180616D* ACNF180816D* ACNF240016D* ACNF240516D* ACNF240616D* ACNF240816D* ACNF241016D* ACNF300016D* ACNF300516D* ACNF300616D* ACNF300816D* ACNF301016D* WARNING AWUF18051** AWUF18081** AWUF24051** AWUF24081** AWUF24101** AWUF30051** AWUF30081** AWUF30101** AWUF36051** AWUF36081** AWUF36101** AWUF37051** AWUF37081** AWUF37101** AWUF180316** AWUF240316** AWUF300316** AWUF240316B* AWUF240516B* AWUF240816B* AWUF241016B* AWUF310516A* AWUF310816A* AWUF321016A* ARPF18241** ARPF30301** ARPF37431** ARPF48601** ARPF182416** ARPF193116** ARPF303016** ARPF363616** ARPF364216** ARPF374316** ARPF486016** ARPF496116** AEPF18301** AEPF30361** AEPF31371** AEPF42601** ASPF183016* ASPF303616* ASPF313716* ASPF426016* ATUF182416** ATUF193116** ATUF303016** ATUF363616** ATUF364216** ATUF374316** ATUF486016** ARUF18241** ARUF30301** ARUF36421** ARUF37431** ARUF48601** ARUF172916** ARUF182416** ARUF193116** ARUF303016** ARUF363616** ARUF364216** ARUF374316** ARUF486016** ARUF496116** The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WARNING ADPF18241** ADPF30421** ADPF48601** ADPF182416** ADPF304216** ADPF486016** To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. WARNING 3 PRODUCT DESIGN WARNING When installing or servicing this equipment, safety clothing, including hand and eye protection, is strongly advised. If installing this equipment in an area that has special safety requirements (hard hats etc.), observe these requirements. To protect the unit when brazing close to the painted surfaces, the use of a quenching cloth is strongly advised to prevent scorching or marring of the equipment finish. AIR HANDLERS *See Air Handler Specification Sheet for Proper Combinations. ALL AIR HANDLERS USE DIRECT DRIVE MOTORS. POWER SUPPLY IS 220-240 V, 60 HZ, 1 PHASE Installation Before installing this appliance insure that it is properly sized and adequate power is available. This appliance can be installed in the vertical or right horizontal position without modification. The horizontal left and downflow positions require product modification. This product is designed for zero inches (0 inches) clearance; however, adequate access for service or replacement must be considered without removing permanent structure. This unit can be installed on a platform when deemed necessary. WARNING The unit MUST have an uninterrupted, unbroken electrical ground to minimize the possibility of personal injury if an electrical fault should occur. The electrical ground circuit may consist of an appropriately sized electrical wire connecting the ground lug in the unit control box to the building electrical service panel. Other methods of grounding are permitted if performed in accordance with the “National Electric Code” (NEC)/“American National Standards Institute” (ANSI)/“National Fire Protection Association” (NFPA) 70 and local/state codes. In Canada, electrical grounding is to be in accordance with the Canadian Electric Code CSA C22.1. Failure to observe this warning can result in electrical shock that can cause personal injury or death. In an attic installation a secondary drain pan must be provided by the installer and placed under the entire unit with a separate drain line properly sloped and terminated in an area visible to the owner. This secondary drain pan is required in the event that there is a leak or main drain blockage. Closed cell insulation should be applied to the drain lines in unconditioned spaces where sweating may occur. Appliances installed in garages, warehouses or other areas where they may be subjected to mechanical damage must be suitably guarded against such damage by installing behind protective barriers, being elevated or located out of the normal path of vehicles. When installed on a base, the base must also be protected by similar means. Heating and cooling equipment located in garages, which may generate a glow, spark or flame capable of igniting flammable vapors, must be installed with the ignition source at least 18"[46cm] above the floor level. When more than one appliance is installed in a building it shall be permanently identified as to the area or space serviced by the equipment. When this product is installed in the downflow installation in an unconditioned space, remove the horizontal drain pan and install the following insulation kit WARNING If this appliance is installed in an enclosed area such as a garage or utility room with any carbon monoxide (CO) producing appliance (i.e. automobile, furnace, water-heaters, etc.), ensure the area is properly ventilated. ARUF, ATUF or ARPF Model 1729 1824 3030 1931 3636 3642 3743 4860 4961 AEPF / ASPF Insulation Kit N/A DPI18-30/20 1830 DPI36-42/20 3036 3137 DPI48-61/-20 4260 This kit is used to prevent sweating on the vertical drain pan. 4 PRODUCT DESIGN To prevent the horizontal drain pan from sweating in high humidity applications, it is recommended that a DPIH insulation accessory kit be used. NOTE: The DPIH insulation kit is not supplied with this product and must be purchased separately. See Chart below for the correct DPIH kit. ARUF, ATUF or ARPF Model 1729 1824 3030 1931 3636 3642 3743 4860 4961 AEPF / ASPF Insulation Kit N/A DPIH18-32 1830 DPIH36-42 3036 3137 DPIH48-61 4260 ACNF AC electric heat air handlers are designed for ceiling mounting and have a direct drive, multi-speed motor. They are available in 1-1/2, 2 and 2 1/2 ton sizes. AWUF is a vertical stud or wall-mount electric heat air handler and features a direct drive, multi-speed motor. The AWUF has a check flowrater for cooling only and heat pump operation, with sequence controlled heating elements of 5, 8, and 10 kW. The AWUF is available in 1 1/2 to 3 ton sizes. *ARPF air handlers are multi-position, multi-speed with direct drive motors. They are available in 1 1/2 to 5 ton sizes with optional 3 kW to 21kW electric heat kits available for field installation. (See note below.) ARUF is a multi-position air handler and can be used with R410A or R-22 (models ending in 1/16) and features a direct drive, multi-speed motor. The ARUF has a check flowrater for cooling-only and heat pump operation. The ARUF is available in 1 1/2 to 5 ton sizes. *AEPF is a multi-position, variable-speed air handler and can be used with R-410A or R-22 (models ending in 1/16). The unit's blower design includes a variable-speed DC motor and is compatible with heat pumps and variable-capacity cooling applications. (See note below.) *ASPF is a multi-position air handler that can be used with R410A or R-22 and it features a energy efficient motor. This motor is a constant torque motor with very low power consumption and it is energized by a 24V signal. The energy efficient motor features an integrated control module and is compatible with heat pumps and cooling applications. (See note below.) *NOTE: Factory-sealed to achieve a 2% or less leakage rate at 1.0" water gauge external duct static pressure. Complies with the Factory-sealed Air Handling Credit as listed in the 2001 Florida Building Code, Chapter 13, Section 610.2.A.2.1. ADPF is a dedicated downflow, multi-speed air handler and is available in 1 1/2 to 5 ton sizes. Electric heat kits are available as a field-installed option. 5 PRODUCT DIMENSIONS DIMENSIONS Model ACNF18 ACNF24 ACNF30 AC18 AC30 AC36 6 A 37¼” 43¼” 49¼” 37¼” 43¼” 49¼” B 3411/16” 4011/16” 4611/16” 3411/16” 4011/16” 4611/16” C 30” 36” 42” 30” 36” 42” D 6½” 6½” 6½” 6½” 6½” 6½” ACNF PRODUCT DIMENSIONS AWUF Small Chassis AWUF 18 & 24 Large Chassis AWUF 30 & 36 A 36" A 36" B 20 3/8" B 24" C 16 1/8" C 21" D 16" D 19 7/8" E 11" E 15 7/8" FILTER 14" X 18" X 1" FILTER 16" X 20" X 1" Large Chassis AWUF 31,32 & 37 A 36" B 24" C 21" D 19 7/8" E 15 7/8" FILTER 18" X 20" X 1" 7 PRODUCT DIMENSIONS ADPF 2 ȹ” Model 8 A B C D E F G ADPF18241/16 42ȶ” 22” 13½” 15½” 10” 3½” 6 1/16” ADPF30421/16 53¼” 24” 20” 22” 12” ADPF48601/16 53¼” 24” 20” 22” 12” H I L M 13ȶ” 17 15/16” 15½” 15 5/16” 9¼” 11 13/16” 19ȸ” 19 15/16” 217/16” 21¼” 9¼” 11 13/16” 19ȸ” 19 15/16” 217/16” 21¼” PRODUCT DIMENSIONS ARPF D B C E A SUCTION LINE LIQUID LINE INLET TUBE F G I INLET (RIGHT SIDE VIEW) H INLET (FRONT VIEW) Model A B C D E F G H I J ARPF18241* 42 1/8" 22" 13 1/2" 15 1/2" 10" 14 1/2" 11 15/16" 13 1/8" 17 15/16" 2" ARPF19311* 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ARPF30301* 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ARPF36361* 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ARPF36421* 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ARPF37431* 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ARPF48601* 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ARPF49611* 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" 9 PRODUCT DIMENSIONS ARUF/ATUF J 2 ȹ” [7.30 cm] Model A B C D E F G H I J ARUF172916 42 1/8" 22" 13 1/2" 15 1/2" 10" 14 1/2" 11 15/16" 13 1/8" 17 15/16" 2" ARUF182416 42 1/8" 22" 13 1/2" 15 1/2" 10" 14 1/2" 11 15/16" 13 1/8" 17 15/16" 2" ARUF193116 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ARUF303016 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ARUF363616 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ARUF364216 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ARUF374316 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ARUF486016 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ARUF496116 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" A B C D E F G H I J ATUF182416 42 1/8" 22" 13 1/2" 15 1/2" 10" 14 1/2" 11 15/16" 13 1/8" 17 15/16" 2" ATUF193116 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ATUF303016 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ATUF363616 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ATUF364216 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ATUF374316 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ATUF486016 53 1/4" 24" 20" 22" 12" 14 1/2" 11 15/16" 19 5/8" 19 15/16" 1 13/16" Model 10 AEPF PRODUCT DIMENSIONS J 2 ȹ” [7.30 cm] Model A B C D E F G H I J AEPF18301/16 46 3/4" 22" 17 1/2" 19 1/2" 10' 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" AEPF30361/16 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" AEPF31371/16 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" AEPF42601/16 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" 11 PRODUCT DIMENSIONS ASPF J 2 ȹ” [7.30 cm] Model A B C D E F G H I J ASPF183016* 46 3/4" 22" 17 1/2" 19 1/2" 10' 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" ASPF303616* 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ASPF313716* 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ASPF426016* 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" 12 PRODUCT SPECIFICATIONS ACNF ACNF18001 ACNF18051 ACNF18061 ACNF18081 ACNF24001 ACNF24051 ACNF24061 ACNF24081 ANF24101 ACNF30001 ACNF30051 ACNF30061 ACNF30081 ACNF30101 ACNF*****AA/AB (copper coils) Diameter 5.75 5.75 5.75 5.75 6.31 6.31 6.31 6.31 6.31 6.75 6.75 6.75 6.75 6.75 W idth 6.75 6.75 6.75 6.75 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 Coil Drain Connection FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Liquid 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Suction 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Blower Lineset Connection Size Electrical Data Min. Circuit Ampacity @ 240V 0.9 27 33.5 40.5 1.68 27.8 34.3 41.3 54.9 1.68 27.8 34.3 41.3 54.9 Min. Circuit Ampacity @ 208V 0.9 2405 30.5 36.8 1.68 25.3 31.36 37.6 49.8 1.68 25.3 31.3 37.6 49 Max. Overcurrent Device 240V 15 30 40 50 15 30 40 50 60 15 30 40 50 8 Max. Overcurrent Device @ 208V 15 30 40 40 15 30 40 40 50 15 30 40 40 60 Minimum VAC 197 197 197 197 197 197 197 197 197 197 197 197 197 50 Maximum VAC 253 253 253 253 253 253 253 253 253 253 253 253 253 253 FLA 0.72 0.72 0.72 0.72 1.34 1.34 1.34 1.34 1.34 1.34 1.34 1.34 1.34 1.34 HP 1/8 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Ship Weight (lbs) 59 59 59 59 69 69 69 69 69 79 79 79 79 79 Blower Motor ACNF180016 ACNF180516 ACNF180616 ACNF180816 ACNF240016 ACNF240516 ACNF240616 ACNF240816 ANF241016 ACNF300016 ACNF300516 ACNF300616 ACNF300816 ACNF301016 ACNF*****DA (with aluminum coils) Diameter 5.75 5.75 5.75 5.75 6.31 6.31 6.31 6.31 6.31 6.75 6.75 6.75 6.75 6.75 Width 6.75 6.75 6.75 6.75 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 Coil Drain Connection FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Liquid 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Suction 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Min. Circuit Ampacity @ 240V 0.9 27 33.5 40.6 1.68 27.8 34.3 41.3 54.9 1.68 27.8 34.3 41.3 54.9 Min. Circuit Ampacity @ 208V 0.9 23.5 29.2 35.3 1.68 24.3 36.1 47.8 49.8 1.68 24.3 29.9 36.1 47.8 Max. Overcurrent Device 240V 15 30 35 45 15 30 45 50 60 15 30 35 45 8 Max. Overcurrent Device @ 208V 15 25 30 40 15 25 40 40 50 15 25 30 40 60 Minimum VAC 197 197 197 197 197 197 197 197 197 197 197 197 197 50 Maximum VAC 253 253 253 253 253 253 253 253 253 253 253 253 253 253 FLA 0.72 0.72 0.72 0.72 1.34 1.34 1.34 1.34 1.34 1.34 1.34 1.34 1.34 1.34 HP 1/8 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Ship Weight (lbs) 54 57 57 57 61 64 64 64 64 65 68 68 68 68 Blower Lineset Connection Size Electrical Data Blower Motor 13 AWUF[18-37]A* AWUF18031** AWUF18051 AWUF18081 AWUF24031** AWUF24051 AWUF24081 AWUF24101 AWUF30031** AWUF30051 AWUF30081 AWUF30101 PRODUCT SPECIFICATIONS 3.0 10,240 4.8 16,390 7.3 24,925 3.0 10,240 4.8 16,390 7.3 24,925 9.8 33,460 3.0 10,240 4.8 16,390 7.3 24,925 9.8 33,460 9" 9" 9" 10" 10" 10" 10" 9" 9" 9" 9" 6" 3/4" 6" 3/4" 6" 3/4" 6" 3/4" 6" 3/4" 6" 3/4" 6" 3/4" 8" 3/4" 8" 3/4" 8" 3/4" 8" 3/4" Liquid 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Suction Electrical Data 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 3/4" Heating Capacity Actual kW @ 240 volts BTU/h @ 240 volts Blower Diameter Width Coil Drain Connection FPT Lineset Connection Size Min. Circuit Ampacity* Max. Overcurrent Device (amps)* 15.1/17.3 26.7/23.3 39.7/34.2 15.1/17.3 26.7/23.3 39.7/34.2 52.7/45.6 15.5/17.6 27.0/23.6 40.0/34.9 53.0/46.2 20/20 30/30 40/40 20/20 30/30 40/40 60/50 20/20 30/25 40/35 60/50 Minimum VAC 197 197 197 197 197 197 197 197 197 197 197 Maximum VAC Blower Motor 253 253 253 253 253 253 253 253 253 253 253 FLA 1.30 1.35 1.35 1.30 1.35 1.35 1.35 1.58 1.58 1.58 1.58 HP Ship Weight (lbs) 1/5 1/5 1/5 1/5 1/5 1/5 1/5 1/3 1/3 1/3 1/3 84 84 84 84 84 84 84 93 93 93 93 14 AWUF310816 AWUF321016 AWUF36051 AWUF36081 AWUF36101 AWUF37051 AWUF37081 AWUF37101 Heating Capacity Actual kW @ 240 volts BTU/h @ 240 volts Blower Diameter Width Coil Drain Connection FPT Lineset Connection Size Liquid Suction Electrical Data Min. Circuit Ampacity* Max. Overcurrent Device (amps)* Minimum VAC Maximum VAC Blower Motor FLA HP Ship Weight (lbs) AWUF310516 * @ 240V/208V 4.8 16,390 7.3 24,925 9.8 33,460 4.8 16,390 7.3 24,925 9.8 33,460 4.8 16,390 7.3 24,925 9.8 33,460 10" 8" 3/4" 10" 8" 3/4" 10" 8" 3/4" 9" 8" 3/4" 9" 8" 3/4" 9" 8" 3/4" 10" 8" 3/4" 10" 8" 3/4" 10" 8" 3/4" 3/8" 3/4" 3/8" 3/4" 3/8" 3/4" 3/8" 3/4" 3/8" 3/4" 3/8" 3/4" 3/8" 3/4" 3/8" 3/4" 3/8" 3/4" 30.1/26.8 43.1/38.1 56.2/49.4 27.0/23.6 40.0/34.9 53.0/46.2 30.1/26.8 43.1/38.1 56.2/49.4 35/30 45/40 60/50 30/25 40/35 60/50 35/30 45/40 60/50 197 197 197 197 197 197 197 197 197 253 253 253 253 253 253 253 253 253 4.1 1/2 96 4.1 1/2 96 4.1 1/2 96 1.58 1/3 96 1.58 1/3 96 1.58 1/3 96 4.1 1/2 96 4.1 1/2 96 4.1 1/2 96 AWUF241016B* AWUF240816B* AWUF[18-24]**16B* AWUF240516B* AWUF240316B* AWUF180816B* AWUF180516B* PRODUCT SPECIFICATIONS Heating Capacity Actual kW @ 240 volts 4.8 7.3 3.0 4.8 7.3 9.8 16,390 24,925 10,240 16,390 24,925 33,460 Diameter 9" 9" 10" 10" 10" 10" Width 6" 6" 6" 6" 6" 6" Coil Drain Connection FPT Lineset Connection Size 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Liquid 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Suction 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" BTU/h @ 240 volts Blower Electrical Data Min. Circuit Ampacity* Max. Overcurrent Device (amps)* 26.6/23.3 30/25 39.6/34.6 15.1/17.3 26.7/23.3 39.7/34.2 52.7/45.6 40/35 20/20 30/30 40/40 60/50 Minimum VAC 197 197 197 197 197 197 Maximum VAC 253 253 253 253 253 253 1.30 1/5 1.30 1/5 1.30 1/5 1.35 1/5 1.35 1/5 1.35 1/5 84 84 84 84 84 84 Blower Motor FLA HP Ship Weight (lbs) * @ 240V/208V 15 PRODUCT SPECIFICATIONS ADPF1824 1/16 ADPF3042 1/16 ADPF4860 1/16 Blower Diameter W idth Coil Drain Connection FPT 9 1/2" 6" 3/4" 10 5/8" 8" 3/4" 10 5/8" 10 5/8" 3/4" Lineset Connection Size Liquid Suction 3/8" 3/4" 3/8" 7/8" 3/8" 7/8" 208/240 2.1/2.1 15/15 197 253 208/240 3.7/3.7 15/15 197 253 208/240 5.4/5.4 15/15 197 253 1.70 1/3 100 2.95 1/2 131 4.30 3/4 160 Electrical Data Voltage Min. Circuit Ampacity* Max. Overcurrent Device (amps)* Minimum VAC Maximum VAC Blower Motor FLA HP Ship Weight (lbs) * @ 208V/240V 16 ADPF ARPF PRODUCT SPECIFICATIONS Blower Diameter Width Coil Drain Connection FPT Lineset Connection Size Liquid Suction Electrical Data Voltage Min. Circuit Ampacity Max. Overcurrent Device (amps) Minimum VAC Maximum VAC Blower M otor FLA HP Ship Weight (lbs) B lowe r D iam eter W idth C oil D rain C onnec tion FP T Line se t C onne ction Siz e Liquid Suc tion Ele ctrical D ata Voltage Min. C irc uit Am pac ity Max. O verc urrent D evic e (am ps Minim um VAC Maxim um VAC B lowe r M otor FLA HP Ship We ight (lbs) ARPF18241* ARPF19311* ARPF30301* ARPF36361* 9 1/ 2" 6" 3/ 4" 9 1/ 2" 6" 3/ 4" 9 1/ 2" 8" 3/ 4" 9 1/ 2" 6" 3/ 4" 3/ 8" 3/ 4" 3/ 8" 7/ 8" 3/ 8" 3/ 4" 3/ 8" 3/ 4" 208 / 240 2.1 / 2.1 15 / 15 197 253 208 / 240 1.9 / 1.9 15 / 15 197 253 208 / 240 3.3 / 3.3 15 / 15 197 253 208 / 240 3.3 / 3.3 15 / 15 197 253 1.70 1/ 3 120 1.48 1/ 4 155 2.64 1/ 3 144 2.64 1/ 3 164 A RPF 36 42 1* A RPF 37 43 1* A RP F4 86 01 * A RPF 49 61 1* 10 5/8" 8" 3/4" 11 15/16" 10 11/16" 3/4" 10 5/8" 10 5/8" 3/4" 10 5/8" 10 5/8" 3/4" 3/8" 7/8" 3/8" 7/8" 3/8" 7/8" 3/8" 7/8" 208 / 240 3.7 / 3.7 15 / 15 197 253 208 / 240 4.2 / 4.2 15 / 15 197 253 208 / 240 5.4 / 5.4 15 / 15 197 253 208 / 240 5.4 / 5.4 15 / 15 197 253 2.95 1/2 160 3.39 1/2 195 4.30 3/4 192 4.30 3/4 192 17 ARUF PRODUCT SPECIFICATIONS ARUF172916 ARUF182416 ARUF193116 ARUF303016 9 1/ 2" 6" 3/ 4" 9 1/ 2" 6" 3/ 4" 9 1/ 2" 6" 3/ 4" 9 1/ 2" 8" 3/ 4" 3/ 8" 3/ 4" 3/ 8" 7/ 8" 3/ 8" 3/ 4" 3/ 8" 3/ 4" 208 / 240 2.1 / 2.1 15 / 15 197 253 208 / 240 2.1 / 2.1 15 / 15 197 253 208 / 240 1.9 / 1.9 15 / 15 197 253 208 / 240 3.3 / 3.3 15 / 15 197 253 1.70 1/ 3 110 1.70 1/ 3 120 1.48 1/ 4 155 2.64 1/ 3 144 Blower Diameter Width Coil Drain Connection FPT Lineset Connection Size Liquid Suction Electrical Data Voltage Min. Circuit Ampacity Max. Overcurrent Device (amps) Minimum VAC Maximum VAC Blower Motor FLA HP Ship Weight (lbs) ARUF363616 ARUF364216 ARUF374316 ARUF486016 ARUF496116 Blower Diameter W idth Coil Drain Connection FPT Lineset Connection Size Liquid Suction Electrical Data Voltage Min. Circuit Ampacity Max. Overcurrent Device (amps) Minimum VAC Maximum VAC Blower Motor FLA HP Ship Weight (lbs) 18 9 1/2" 6" 3/4" 10 5/8" 8" 3/4" 11 15/16" 10 11/16" 3/4" 10 5/8" 10 5/8" 3/4" 10 5/8" 10 5/8" 3/4" 3/8" 3/4" 3/8" 7/8" 3/8" 7/8" 3/8" 7/8" 3/8" 7/8" 208 / 240 3.3 / 3.3 15 / 15 197 253 208 / 240 3.7 / 3.7 15 / 15 197 253 208 / 240 4.2 / 4.2 15 / 15 197 253 208 / 240 5.4 / 5.4 15 / 15 197 253 208 / 240 5.4 / 5.4 15 / 15 197 253 2.64 1/3 164 2.95 1/2 160 3.39 1/2 195 4.30 3/4 192 4.30 3/4 192 PRODUCT SPECIFICATIONS Blower Diameter Width Coil Drain Connection FPT Lineset Connection Size Liquid Suction Electrical Data Voltage Min. Circuit Ampacity Max. Overcurrent Device (amps) Minimum VAC Maximum VAC Blower Motor FLA HP Ship Weight (lbs) Blower Diameter Width Coil Drain Connection FPT Lineset Connection Size Liquid Suction Electrical Data Voltage Min. Circuit Ampacity Max. Overcurrent Device (amps) Minimum VAC Maximum VAC Blower Motor FLA HP Ship Weight (lbs) ATUF ATUF182416 ATUF193116 ATUF303016 ATUF363616 9 1/2" 6" 3/4" 9 1/2" 6" 3/4" 9 1/2" 8" 3/4" 9 1/2" 6" 3/4" 3/8" 7/8" 3/8" 3/4" 3/8" 3/4" 3/8" 3/4" 208 / 240 2.1 / 2.1 15 / 15 197 253 208 / 240 1.9 / 1.9 15 / 15 197 253 208 / 240 3.3 / 3.3 15 / 15 197 253 208 / 240 3.3 / 3.3 15 / 15 197 253 1.70 1/3 120 1.48 1/4 155 2.64 1/3 144 2.64 1/3 164 ATUF364216 ATUF374316 ATUF486016 10 5/8" 8" 3/4" 11 15/16" 10 11/16" 3/4" 10 5/8" 10 5/8" 3/4" 3/8" 7/8" 3/8" 7/8" 3/8" 7/8" 208 / 240 3.7 / 3.7 15 / 15 197 253 208 / 240 4.2 / 4.2 15 / 15 197 253 208 / 240 5.4 / 5.4 15 / 15 197 253 2.95 1/2 173 3.39 1/2 195 4.30 3/4 192 19 AEPF PRODUCT SPECIFICATIONS AEPF183016* AEPF303616* AEPF313716* AEPF426016* 9 1/2" 10 5/8" 10 5/8" 10 5/8" 8" 10 5/8" 10 5/8" 10 5/8" Coil Drain Connection FPT Lineset Connection Size 3/4" 3/4" 3/4" 3/4" Liquid 3/8" 3/8" 3/8" 3/8" Suction Electrical Data Voltage 3/4" 7/8" 7/8" 7/8" 208/240 208/240 208/240 208/240 Min. Circuit Ampacity* 2.5/2.5 3.1/3.1 3.1/3.1 7.8/7.8 15/15 15/15 15/15 15/15 197 253 197 253 197 253 197 253 FLA 2.00 2.50 2.50 6.20 HP Ship Weight (lbs) 1/2 3/4 3/4 3/4 125 176 176 195 Blower Diameter Width Max. Overcurrent Device (amps)* Minimum VAC Maximum VAC Blower Motor ASPF B lowe r D iam eter W idth C oil D rain C onnec tion FPT Line se t C onne ction Siz e Liquid Suc tion Ele ctrical D ata Voltage Min. C irc uit Am pac ity Max. O verc urrent D evic e (am ps ) Minim um VAC Maxim um VAC B lowe r M otor FLA HP Ship We ight (lbs) 20 AS PF183016* ASPF303616* AS PF313716* ASPF426016* 9 1/2" 8" 3/4" 10 5/8" 10 5/8" 3/4" 10 5/8" 10 5/8" 3/4" 10 15/16" 10 11/16" 3/4" 3/8" 3/4" 3/8" 7/8" 3/8" 7/8" 3/8" 7/8" 208 / 230 3.6 / 3.6 15 / 15 197 253 208 / 230 3.8 / 3.8 15 / 15 197 253 208 / 230 3.9 / 3.9 15 / 15 197 253 208 / 230 6.4 / 6.4 15 / 15 197 253 2.9 1/2 125 3.0 3/4 176 3.1 3/4 176 5.1 3/4 195 BLOWER PERFORMANCE DATA Model ACNF18001 ACNF18051 ACNF18061 ACNF18081 ACNF24001 ACNF24051 ACNF24061 ACNF24081 ACNF24101 ACNF30001 ACNF30051 ACNF30061 ACNF30081 ACNF30101 Speed ACNF CFM delivered against External Static Pressure 0.1” 0.2” 0.3” 0.4” 0.5” High 780 710 625 520 440 Low High Low High Low High Low High 675 780 675 780 675 780 675 935 585 710 585 710 585 710 585 880 510 625 510 625 510 625 510 810 460 520 460 520 460 520 460 735 400 440 400 440 400 440 400 675 Low High Low High Low High Low High Low High Low High Low High Low High Low High Low 720 935 720 935 720 935 720 935 720 1,075 830 1,075 830 1,075 830 1,075 830 1,075 830 680 880 680 880 680 880 680 880 680 1,015 785 1,015 785 1,015 785 1,015 785 1,015 785 630 810 630 810 630 810 630 810 630 945 720 945 720 945 720 945 720 945 720 565 735 565 735 565 735 565 735 565 865 665 865 665 865 665 865 665 865 665 490 675 490 675 490 675 490 675 490 770 605 770 605 770 605 770 605 770 605 Note: Assumes dry coil with filter in place; 208-volt operation x .96 21 PRODUCT SPECIFICATIONS ACNF ACNF*****DA (with aluminum coils) Model Speed ACNF180016 ACNF180516 ACNF180616 ACNF180616 ACNF240016 ACNF240516 ACNF240616 ACNF240816 ACNF241016 ACNF300016 ACNF300516 ACNF300616 ACNF300816 ACNF31016 CFM deliverd against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" High 610 525 480 400 320 Low 545 470 400 340 250 High 610 525 480 400 320 Low 545 470 400 340 250 High 610 525 480 400 320 Low 545 470 400 340 250 High 610 525 480 400 320 Low 545 470 400 340 250 High 945 860 800 725 670 Low 850 800 725 680 600 High 945 860 800 725 670 Low 850 800 725 680 600 High 945 860 800 725 670 Low 850 800 725 680 600 High 945 860 800 725 670 Low 850 800 725 680 600 High 945 860 800 725 670 Low 850 800 725 680 600 High 1,060 985 895 805 720 Low 905 845 780 710 625 High 1,060 985 895 805 720 Low 905 845 780 710 625 High 1,060 985 895 805 720 Low 905 845 780 710 625 High 1,060 985 895 805 720 Low 905 845 780 710 625 High 1,060 985 895 805 720 Low 905 845 780 710 625 Heating Capacity/kW Correction Factor 22 Supply Voltage 240 230 220 210 208 Correction Factor 1.08 1.00 0.92 0.84 0.82 BLOWER PERFORMANCE DATA Model AWUF18XX1/16A* AWUF18XX16B* AWUF24XX1/16A* AWUF24XX16B* AWUF30XX1/16A* AWUF30XX16B* AWUF310516XX AWUF310816XX/ AWUF321016XX AWUF36XX1/16A* AWUF36XX16B* AWUF37XX16A* AWUF37XX16B* Speed AWUF CFM deliverd against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" High 750 730 690 650 595 Low 710 700 690 635 585 High 755 715 670 615 545 Low 740 700 655 595 535 High 880 845 810 770 735 Low 845 815 780 745 705 High 900 870 835 795 760 Low 865 835 800 765 725 High 1250 1195 1135 1085 1010 Low 1110 1055 1020 955 905 High 1255 1120 1100 1020 950 Low 1115 1010 990 900 820 T5 875 865 830 805 765 T4 1005 975 945 920 890 T3 840 795 785 745 700 T2 645 615 550 500 445 T1 645 615 550 500 445 T5 1090 1065 1040 1015 985 T4 1005 975 945 920 890 T3 840 795 785 745 700 T2 645 615 550 500 445 T1 645 615 550 500 445 High 1280 1190 1110 1010 930 Low 1170 1100 1030 950 890 High 1215 1145 1070 985 890 Low 1120 1065 1000 915 820 High 1326 1284 1232 1181 1115 Low 1086 1061 1028 996 950 T5 1385 1205 1130 1045 950 T4 1235 1180 1115 1040 955 T3 1165 1120 1075 1025 945 T2 1050 1010 970 930 860 T1 1050 1010 970 930 860 Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V) 23 BLOWER PERFORMANCE DATA Model CFM deliverd against External Static Pressure Speed ADPF18241/16 ADPF30421/16 ADPF48601/16 ADPF 0.1" 0.2" 0.3" 0.4" 0.5" H igh 1,155 1,090 1,025 950 895 Med. 940 890 860 815 755 Low 695 665 650 610 550 H igh 1,700 1,660 1,625 1,545 1,505 Med. 1,500 1,440 1,400 1,350 1,345 Low 1,370 1,300 1,250 1,230 1,220 H igh 2,150 2,120 2,070 2,000 1,940 Med. 1,940 1,930 1,905 1,860 1,790 Low 1,610 1,600 1,590 1,575 1,550 Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V) M odel ARPF18241* ARPF19311* ARPF30301* ARPF36361* ARPF36421* ARPF37431* ARPF48601* ARPF49611* Speed CFM deliverd against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" High 1155 1090 1025 950 895 M ed. 940 890 860 815 755 Low 695 665 650 610 550 High 1135 1085 1025 965 915 M ed. 860 825 780 750 680 Low 600 570 545 500 465 High 1385 1315 1240 1155 1065 M ed. 1340 1290 1230 1140 1050 Low 1075 1030 980 910 840 High 1310 1240 1155 1090 1020 M ed. 1270 1210 1140 1075 980 Low 1045 1005 955 885 805 High 1700 1660 1625 1545 1505 M ed. 1500 1440 1400 1350 1345 Low 1330 1300 1250 1230 1220 High 2065 2000 1925 1860 1780 M ed. 1685 1635 1550 1470 1410 Low 1490 1425 1345 1280 1205 High 2150 2120 2070 2000 1940 M ed. 1940 1930 1905 1860 1790 Low 1610 1600 1590 1575 1550 High 2150 2105 2040 1970 1880 M ed. 1960 1935 1895 1825 1750 Low 1670 1625 1585 1525 1455 Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V) 24 ARPF BLOWER PERFORMANCE DATA M odel ARUF172916 ARUF182416 ARUF193116 ARUF303016 ARUF363616 ARUF364216 ARUF374316 ARUF486016 ARUF496116 Speed ARUF CFM deliverd against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" High 1155 1090 1025 950 895 M ed. 940 890 860 815 755 Low 695 665 650 610 550 High 1155 1090 1025 950 895 M ed. 940 890 860 815 755 Low 695 665 650 610 550 High 1135 1085 1025 965 915 M ed. 860 825 780 750 680 Low 600 570 545 500 465 High 1385 1315 1240 1155 1065 M ed. 1340 1290 1230 1140 1050 Low 1075 1030 980 910 840 High 1310 1240 1155 1090 1020 M ed. 1270 1210 1140 1075 980 Low 1045 1005 955 885 805 High 1700 1660 1625 1545 1505 M ed. 1500 1440 1400 1350 1345 Low 1330 1300 1250 1230 1220 High 2065 2000 1925 1860 1780 M ed. 1685 1635 1550 1470 1410 Low 1490 1425 1345 1280 1205 High 2150 2120 2070 2000 1940 M ed. 1940 1930 1905 1860 1790 Low 1610 1600 1590 1575 1550 High 2150 2105 2040 1970 1880 M ed. 1960 1935 1895 1825 1750 Low 1670 1625 1585 1525 1455 Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V) 25 BLOWER PERFORMANCE DATA Model ATUF182416 ATUF193116 ATUF303016 ATUF363616 ATUF364216 ATUF374316 ATUF486016 Speed ATUF CFM deliverd against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" High 1,155 1,090 1,025 950 895 Med. 875 830 790 750 715 Low 640 610 570 535 490 High 1,135 1,085 1,025 965 915 Med. 860 825 780 750 680 Low 600 570 545 500 465 High 1,455 1,385 1,330 1,205 1,090 Med. 1,340 1,290 1,230 1,140 1,050 Low 1,075 1,030 980 910 840 High 1,345 1,290 1,230 1,150 1,070 Med. 1,270 1,210 1,140 1,075 980 Low 1,045 1,005 955 885 805 High 1,700 1,680 1,645 1,610 1,535 Med. 1,500 1,480 1,440 1,380 1,325 Low 135 1,320 1,275 1,230 1,195 High 2,065 2,000 1,925 1,860 1,780 Med. 1,685 1,635 1,550 1,470 1,410 Low 1,490 1,425 1,345 1,280 1,205 High 2,135 2,080 1,985 1,900 1,805 Med. 1,975 1,935 1,875 1,775 1,675 Low 1,715 1,670 1,650 1,590 1,530 Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V) 26 BLOWER PERFORMANCE DATA AEPF The AEPF air handler blower motor is pre-programmed for operation at four distinct airflow levels when operating in the Cooling, Heat Pump heating, Backup heating (Electric Heating), and Backup + Heat Pump heating modes. Each modes has four levels to deliver different CFM. Simply flip the dipswitch for a different CFM combination. Setting the Motor O N O F F 1 2 3 Dipswitch Number Function 1 Electric Heat Mode 2 Electric Heat Mode 3 N/A 4 5 6 7 8 Instructions Select the taps allow in the tables (dipswitch 1/2 & 7/8) below N/A ON = The system operates with single-stage units using a single-stage cooling or heat pump thermostat. (factory default) OFF = The system operates with two-stage units with either a conventional two-stage cooling/heat pump thermosat or with an encoded two-stage condensing unit in retrofit applications where not enough existing wires are available for connections to the indoor thermostat and outdoor units. 4 Thermostat Mode 5 Cooling/Heat Pump Mode Find the airflow for your application in the tables (Dipswitch 5/6 & 7/8) below. 6 Cooling/Heat Pump Mode 7 Trim CFM Adjust Mode Set up the motor based on the outdoor unit capacity tons. Increase or decrease your selected airflow to fit your requirement. 8 Trim CFM Adjust Mode ON-OFF = Increases selected Cool/Heat Pump airflow by 10% OFF-ON = Decreases selected cool/Heat Pump airflow by 15% NOTE: Other setting have no effect on the set airflow. Dipswitch 1/2 & 7/8 AEPF 1830 Heating Element Dipswitch 5/6 & 7/8 AEPF 1830 Switch Position Switch Position 5 6 7 8 Cooling Heat Pump OFF OFF OFF OFF 1100 1100 935 ON OFF OFF OFF 800 800 770 OFF ON OFF OFF 600 600 Switch Position Switch Position (kw) 1 2 7 8 UP TO 10 OFF OFF OFF OFF 1100 1210 UP TO 10 ON OFF OFF OFF 890 5 OFF ON OFF OFF 700 Emergency Heat Pump Backup With Backup AEPF3036 / 3137 / 4260 AEPF3036 / 3137 / 4260 Heating Element Indoor Airflow Switch Position Switch Position (kw) 1 7 UP TO 20 OFF OFF OFF OFF 2050 2150 OFF OFF OFF OFF 1800 1800 UP TO 20 ON OFF OFF OFF 1750 1835 ON OFF OFF OFF 1580 1580 UP TO 15 OFF ON OFF OFF 1600 1680 OFF ON OFF OFF 1480 1480 ON OFF OFF 1200 1200 ON OFF ON 1020 1020 2 8 Emergency Heat Pump Backup With Backup Switch Position Switch Position 5 7 UP TO 10 ON ON OFF OFF 1200 1260 ON UP TO 10 ON ON OFF ON 1020 1070 ON 6 8 Indoor Airflow Cooling Heat Pump NOTE: When applying a humidistat (normally closed), refer to the installation and operating instructions. The humidstat can adjust the cooling airflow to 85%. 27 BLOWER PERFORMANCE DATA M odel ASPF183016 ASPF303616 ASPF313716 ASPF426016 M otor Speed Tap ASPF CFM deliverd against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" 1 700 670 650 595 510 2 820 785 765 745 705 3 920 900 850 840 815 4 1075 1055 1015 975 960 5 1130 1115 1085 1040 1000 1 1060 865 600 515 420 2 1105 910 795 745 690 3 1165 1070 1020 960 915 4 1285 1240 1195 1140 1100 5 1435 1395 1350 1315 1265 1 1060 865 600 515 420 2 1105 910 795 745 690 3 1165 1070 1020 960 915 4 1285 1240 1195 1140 1100 5 1435 1395 1350 1315 1265 1 1445 1275 1175 940 855 2 1545 1405 1325 1260 1145 3 1660 1610 1555 1490 1415 4 1905 1870 1810 1750 1695 5 2115 2070 2000 1965 1915 Notes: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208/240V) All ASPF models are shipped from the factory with the speed tap set on T4. 28 Notes: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208/240V) All ASPF models are shipped from the factory with the speed tap set on T4. WIRING DIAGRAMS ACNF HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 29 30 GR BR WH BL RD RD M2 R1 M1 BR RD M4 BL RD * M3 RD * EBTDR SU BR BL WH COM NO NC M2 M1 EVAPORATOR MOTOR LEADS PU COMMON BK HIGH RD LOW BK G C XFMR-C R XFMR-R BR FC EM BR RD PU BK SEE NOTE 5 RD BK * 5 3 RD BK TL1 TL1 2 RD 4 1 BK TL2* HTR2* HTR1 TL2 TR RD RD DISC EM EBTDR WH BK RD YL BL TL1 TL1 HI 4 GREEN PURPLE BROWN 5 DISCONNECT SWITCH EVAPORATOR MOTOR ELECTRONIC BLOWER TIME DELAY RELAY R FC TL TR HTR COMPONENT CODE GR PU BR 24 VOLT 3 LO HTR 1 * HTR 2 SEE NOTE 1 1 2 EM COLOR CODE TR WHITE BLACK RED YELLOW BLUE RD R EBTDR FC * WH BR EBTDR RELAY FAN CAPACITOR THERMAL LIMIT TRANSFORMER HEATER ELEMENT NO * 4) ASTERISK (*) I NDICATES THAT HEATING ELEMENT , THERMAL LIMIT, RELAY (SEQUENCER) AND INT ERCO NNECTING WI RES AND JUMPERS OF HEATER #2 ARE DELET ED WI TH SINGLE ELEMENT UNITS. 3) SEE COMPOSIT E WI RING DI AGRAM S IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WI RING CONNECTIONS. BT14933447 REV B 5) EBTDR HAS A 7 SECOND ON DELAY W HEN "G" IS ENERGIZED AND A 65 SECOND OFF DELAY W HEN "G " IS DE-ENERGIZED. GR NOTE 3 R1 COM M1 EBTDR NC M2 M3 R1 * WIRING CODE M2 * M4 FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE BL TL2 * TL2 C 208/230 VOLTS 1) RED WI RE TO B E ON TRANSFORMER TERMINAL 3 FOR 230 VOLTS AND ON TERMINAL 2 F OR 208 VOLTS. 2) TO PLACE AIRHANDLER IN HIGH SPEED, REMOVE RED MOTOR LEAD FROM E LECTRONIC BLOW ER TIME DELAY RELAY (EBTDR) COM TERMINAL AND REPLACE WI TH BLACK MOTOR LEAD. ALL UNITS WI LL BE FACTORY CONNECTED AT LOW SPEED. NOTES: * CONTROLS SHOWN WITH UTILITIES IN "ON" POSITION AND THERMOSTAT IN "OFF" POSITION. IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE 105°C. WIRE. SIZE TO CONFORM TO THE NATIONA L ELECTRIC CODE. POWER SUPPLY (SEE RATING PLATE) USE MIN. 75°C FIELD WIRE RD SEE NOTE 3 DISC PU BK BK DISC RD RD RD EQUIPMENT GROUND G WIRING DIAGRAMS AWUF [18, 24, 30, 36]** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WIRING DIAGRAMS AWUF[31-32]** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 31 RD BK RD PULL TO DISCONNECT 32 M4 T2 M3 T1 BL GR BL RD M2 RD BK M1 RD BK BK WH WH BR RD RD RD WH OR BR WH RD BK GR BL PU C L GN EM 12345 OR BR YL WH 1 2 4 5 BL 3 YL TO RELAY SEE NOTE # 2 GR/YL FIELD CONNECTIONS WH PU BL BL 2 24V 1 5 BK BK BK 4 3 RD 240 TR * RD HTR2* HTR1 FUSE TL2* TL2 NOTE 3 0140A00036 REV. A 7. COMPONENT CODE: DISC -- DISCONNECT SWITCH EM -- EVAPORATOR MOTOR EBTDR -- ELECTRIC BLOW ER TIME DELAY RELAY 6. W IRING CODE: FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD W IRING HIGH VOLTAGE LOW VOLTAGE R -- RELAY FC -- FAN CAPACITOR TL -- THERMAL LIMIT TR -- TRANSFORMER HTR -- HEATER ELEMENT 1. RED W IRE TO BE ON TRANSFORMER TERMINAL 3 FOR 230 VOLTS AND ON TERMINAL 2 FOR 208 VOLTS. 2. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED CONNECT APPROPRIATE W IRE FROM MOTOR TO TERMINAL # 4 ON RELAY. 3. SEE COMPOSITE W IRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 4. ASTERISK (*) INDICATES THAT HEATING ELEMENT, THERMAL LIMIT, RELAY (SEQUENCER) AND INTERCONNECTING W IRES AND JUMPERS OF HEATER # 2 AR E DELETED WITH SINGLE ELEMENT UNITS. 5. COLOR CODE: W H -- W HITE GR -- GREEN BK -- BLACK PU -- PURPLE RD -- RED BR -- BROW N YL -- YELLOW BL -- BLUE NOTES: RD RD WIRING DIAGRAMS AWUF37 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WIRING DIAGRAMS ADPF, ARPF, ARUF, ATUF HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FL FL FL FL HTR2 TL FL HTR1 TL FL HTR1 TL FL FL HTR1 TL RD BK BK BK HTR2 TL FL RD 1 HTR3 TL FL 2 BK RD YL HTR3 TL BK BK HTR1 TL HTR2 TL 1 BK HTR4 TL 1 BL BK RD 2 PU BK 3 YL PU 4 M1 R BK M2 M1 M1 4 M2 6 BK M2 5 M4 M3 WH 3 M1 YL R2 RD 5 BR M3 M2 M4 M5 M7 M6 M8 R1 RD WH 3 RD BL R2 BR 4 5 BK 6 BK 6 RD WH 6 7 7 BK 8 BK RD 4 M2 RD BK RD BL BL RD BL M1 M4 PU BK BK 7 BK RD R1 R WH BL 3 M3 2 PU BK BL RD 5 1 2 YL RD RD BL 7 YL 8 RD YL BK 8 RD 9 BL BK 9 8 RD 9 9 L1 L2 L1 ONE (1) ELEMENT ROWS L2 L1 TWO (2) ELEMENT ROWS L2 L1 L2 THREE (3) ELEMENT ROWS L1 L2 L1 L2 FOUR (4) ELEMENT ROWS NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEAT ER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. TERMINAL BLOCK SHOWN FOR 50HZ MODELS ONLY BL RD GR WH L1 L2 BK RD PLM 1 2 3 4 5 6 7 8 9 PLF 1 2 3 4 5 6 7 8 9 BK RD PU BL BR WH EQUIPMENT GROUND EQUIPMENT GROUND USE COPPER OR ALUMINUM USE COPPER WIRE WIRE BR 208/240 VOLTS GRD L2 L1 SR PLM 2 1 PLM 1 PLF 3 2 EM RC SEE NOTE 4 SEE NOTE 2 PLF LO M1 EBTDR M2 BR HI WH 1 2 3 4 24V 5 NO NC COM SEE NOTE 1 TR C EBTDR R GR SEE NOTE 5 RD G BL NO K1 COM K1 C BL SPEEDUP RD C 6 SEE NOTE 1 1 2 3 BK RD 240 TR PU 5 24V 4 COMPONENT CODE RD SEE NOTE 3 PU BK THREE SPEED MOTOR WIRING (SELECT MODELS ONLY) SEE NOTE 3 (M1) RD (M2) BL MEDIUM HIGH PU BR IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. RD LOW (COM) BK (TR 1) PU RC RC BR EM 3 SPEED BL WH BR RD COPPERPOWER OR ALUMINUM COPPER SUPPLY POWER SUPPLY (SEE RATING PLATE) (SEE RATING PLATE) USE 75°CFIELD FIELDWIRE WIRE USE MIN. MIN. 75°C G 4 PLF GR GREEN BK BLACK PU PURPLE RD RED YL YELLOW BR BROWN BL BLUE WH WHITE BL BL M2 5 COLOR CODE NC M1 EBTDR RD PU EBTDR R XFMR-R XFMR-C RD BK EM BR EM RC SR R EBTDR EVAPORATOR MOTOR RUN CAPACITOR STRAIN RELIEF RELAY ELECTRONIC BLOWER TIME DELAY RELAY GR WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE NOTE 2 TR PLF PLM FL TL HTR TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS Notes: 1) Red wires to be on transformer terminal "3" for 240 volts and on terminal "2" for 208 volts. 2) See composite wiring diagrams in installation instructions for proper low voltage wiring connections. 3) Confirm speed tap selected is appropriate for application. If speed tap needs to be changed, connect appropriate motor wire (Red for low, Blue for medium, and Black for high speed) on "COM" connection of the EBTDR. Inactive motor wires should be connected to "M1 or M2" on EBTDR. 4) Brown and white wires are used with Heat Kits only. 5) EBTDR has a 7 second on delay when "G" is energized and a 65 second off delay when "G" is de-energized. 0140M00037 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 33 WIRING DIAGRAMS ADPF, ARPF, ARUF HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FL FL FL FL HTR2 TL FL HTR1 TL HTR1 TL FL BK BK RD HTR2 TL FL RD 1 BK RD HTR3 TL FL 2 BK HTR2 TL FL HTR1 TL BK HTR1 TL FL YL HTR3 TL BK 1 BK HTR4 TL 1 BL BK RD 2 PU BK 3 BL 4 M1 R PU BL BK RD M1 5 M2 YL M1 M2 M2 5 M4 M3 M1 M4 WH 4 M1 YL M2 R2 RD 5 BR M2 M3 M4 M5 M7 M6 M8 R1 RD WH BK 3 RD BL R2 BK RD 6 6 BR WH 4 5 6 7 7 7 YL BK 8 B K RD BL RD BK RD BL BK BK 7 BK RD 2 PU 3 RD BL R1 6 BK BL 4 M3 R WH PU BK 3 1 2 YL RD RD 8 RD YL BK 8 RD 9 BL BK 9 8 RD 9 9 L1 L2 L1 ONE (1) ELEMENT ROWS L2 L1 TWO (2) ELEMENT ROWS L2 L1 L2 THREE (3) ELEMENT ROWS L1 L2 L1 L2 FOUR (4) ELEMENT ROWS NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. SEE NOTE 2 BL TERMINAL BLOCK SHOWN FOR 50HZ MODELS ONLY RD GR WH L1 L2 BK RD EQUIPMENT GROUND USE COPPER WIRE 208/240 VOLTS BR GRD SR L1 PLM 1 2 3 4 5 6 7 8 9 PLF 1 2 3 4 5 6 7 8 9 BK RD PU BL BR WH L2 PLM 2 1 PLM 1 PLF 3 2 EM RC SEE NOTE 4 HI M1 LO 1 2 3 4 24V 5 NO NC EBTDR M2 BR WH PLF COM SEE NOTE 1 TR C EBTDR R GR RD G BL K1 COM K1 C BL SPEEDUP RD NO C 6 SEE NOTE 1 2 1 3 RD RD 240 TR PU 5 24V 4 BK RD YL BL BL BL M2 COMPONENT CODE BK SEE NOTE 3 RD PU EM RC SR R EBTDR NOTES: THREE SPEED MOTOR WIRING (SELECT MODELS ONLY) SEE NOTE 3 (COM) RD (M1) (TR 1) IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. BK LOW (M2) BL MEDIUM BK HIGH PU BR PU RC RC BR EM 3 SPEED EM BR GR BL WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE EVAPORATOR MOTOR TR RUN CAPACITOR PLF STRAIN RELIEF PLM FL RELAY TL ELECTRONIC BLOWER TIME HTR DELAY RELAY TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS 1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS 2) SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS 3) CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT APPROPRIATE MOTOR WIRE (RED FOR LOW, BLUE FOR MEDIUM,AND BLACK FOR HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR INACTIVE MOTOR WIRES SHOULD BE CONNECTED TO "M1 OR M2" ON EBTDR. 4) BROWN AND WHITE WIRES ARE USED WITH HEAT KITS ONLY. 5) EBTDR HAS A 7 SECOND ON DELAY WHEN "G" IS ENERGIZED AND A 65 SECOND OFF DELAY WHEN "G" IS DE-ENERGIZED. 0140M00170-E Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 34 G 4 PLF WH BR BLACK GR GREEN RED PU PURPLE YELLOW BR BROWN BLUE WH WHITE RD COPPER POWER SUPPLY (SEE RATING PLATE) USE MIN. 75°C FIELD WIRE 5 COLOR CODE NC M1 EBTDR RD PU EBTDR R XFMR-R XFMR-C RD BK SEE NOTE 5 WIRING DIAGRAMS AEPF HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FL FL FL FL HTR2 TL FL HTR1 TL HTR1 TL FL R BK BK HTR2 TL FL HTR3 TL FL BK R R 1 BK BK HTR2 TL FL HTR1 TL BK HTR1 TL FL Y HTR3 TL 1 BK 2 HTR4 TL 1 BL BK R 2 PU BK 3 BL Y PU 4 M1 R BK R M1 5 M2 3 4 M3 M2 5 M4 W 7 BL 4 BR 5 R2 R W 3 R M1 Y M2 R M3 M2 M4 M5 M7 M6 M8 R1 6 R2 BK R BK 6 BL 4 BR 5 W 6 7 7 7 Y BK 8 BK R BL R BK R BL BK BK BK M4 M2 3 R M1 R1 6 BK R M3 2 PU BL M1 R W PU BK BL 1 2 Y R R 8 R Y BK 8 R 9 8 BL BK 9 R 9 9 L1 L2 L1 ONE (1) ELEMENT ROWS L2 L1 TWO (2) ELEMENT ROWS L2 L1 L2 THREE (3) ELEMENT ROWS L1 L2 L1 L2 FOUR (4) ELEMENT ROWS AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED NO MARK INDICATES NO HEAT KIT INSTALLED TO C ONDEN SER * SEE NOTE 7 LO W VOLTAGE FIEL D CO N NEC TION B OX TO TH ERM OSTAT 208/240 VOLTS W 1 C Y1 Y/Y2 YCO N O G R C W2 W2 R O R PL 1 2 PL 2 2 SEE N OTE 8 BK Y R O BL W BR BL BR PL 1 1 PL 2 Y PU R 1 TO L OW VOLTAG E TER MINAL BOARD EM G O PL 1 1 2 3 4 5 67 PL 2 1 2 3 4 5 6 8 9 8 9 2 1 7 3 TR BL BK Y TR 20 8 2 24V 3 COM 5 BL R 5 PL 2 6 W2 C R W1 HUM OT 2 OT 1 YCO N IN4005 DIODE P J4 OT C O W W2 Y1 E W1 N OTE DIOD E ON VSTB Y Y2 G C *SEE N O TE 7 W SEE NOT E 2 SEE N OTE 3 BK SEE N O TE 1 PU Y1 R 24 VAC THERMOSTATS OT1 OT2 C R R BL BR BL PL 2 SE E N O TE 4 PJ2 PJ6 R 4 PL2 SEE N O TE 5 W2 BR O BR O OTC W1 HEATER R G G HUM HUMIDISTAT Y/Y2 Y1 DS 1 J2 J3 W E\W1 ED PJ4 PJ2 OU TD O OR W2 W2 BL W/W2 W1 PJ6 BR CONDE NSER HEATPUMP R Y CON COM O OT1 OT2 W BL 5 4 2 4 VOLT 4 J1 HUM P N. B1368270 RE V. A 24 0 1 R Y C OLOR C O DE R BL BR W R W BK R Y BL G W HITE BL AC K R ED YEL LO W BL UE G PU BR 0 PK W IRIN G COD E GR E EN PUR PL E BROW N ORANG E PIN K FAC TO RY W IRIN G HIGH VO LTAGE LOW VO LTAG E FIEL D W IRIN G HIGH VO LTAGE LOW VO LTAG E C O MPON ENT C ODE EM PL PJ2,PJ 4,PJ6 VSTB FL EVA PORATO R M O TOR PLUG PRO GRAM JU MPER VAR IABLE S PEED TER MINAL BOARD FU SE LI NK TL H TR R TR TH E RM AL LIMIT H EA T EL EMEN T R EL AY TR ANSF ORMER EM C OPPER POW ER SUP PLY (SEE RATIN G PLATE) EQUIPM EN T GRO UN D U SE COPPER W IR E NOTES: 1. 2. 3. 4. 5. 6. 7. 8. FOR HEAT PUMP APPLICATIONS REMOVE ORANGE JUMPER WIRE BETWEEN O & Y1. FOR TWO STAGE ELECTRIC HEAT APPLICATIONS CUT PJ4. (USE ONLY ON 15 & 20 KW MODELS). FOR OUTDOOR THERMOSTAT OPERATION OF SECOND STAGE HEAT, CUT PJ2 & ADD OT18-60 TO OTC & OT2. FOR SINGLE STAGE COOLING APPLICATIONS CONNECT THERMOSTAT TO Y/Y2 ONLY, TAPE OR REMOVE Y1 CONNECTION. CONNECT CONDENSING UNIT TO YCON & C. WHEN HUMIDSTAT IS PROVIDED CUT PJ6. THERMOSTAT OPENS ON HUMIDITY RISE. RED WI RES TO BE ON TRANSFORMER TERMINAL 3 FOR 240 VOLT S AND ON TERMINAL 2 FOR 208 VOLTS. SEE COMPOSITE WIRING DIAGRAMS IN I NSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE CONNECTIONS AND DETAILS ON COMPATIBLE THERMOSTATS AND THEIR CONNECTIONS. DISCARD ORIGINAL "PL1" PLUG CONNECTOR WHEN INSTALLING OPTIONAL HEAT KIT. C ONTR OLS SHOW N W ITH U TILIT IES IN " ON" POSITION AND TH ERM OSTAT IN "O FF" POSIT IO N . IF REPL AC EM ENT OF THE ORIGINAL W IR ES S U PPL IED W ITH THIS ASSEM BLY IS N EC ESSAR Y, U SE 1 05°C . W IRE. SIZE TO CONFO RM T O T HE NATIO NA L ELECT RI C C ODE. 0 1 40 A0 00 00 P Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 35 WIRING DIAGRAMS AEPF******CA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FL HTR1 TL HTR 1 TL BK HTR2 TL BK RD 2 FL PL1 1 HTR 2 HTR3 1 BK TL HTR 1 TL BK FL RD FL PL1 TL BK BK HTR 2 TL RD HTR 3 TL FL YL PL1 1 HTR 4 TL RD 2 PU BK TL HTR1 FL FL PL1 BK FL FL FL 3 YL PU 4 M1 RD R M1 RD M3 BK 5 M4 BK WH 7 RD 8 BL BL BK RD 4 M2 M1 YL R2 RD 5 BR WH 3 BL M3 M2 M4 M5 M7 M6 M8 R1 BK RD RD R2 BL 4 BR 5 BK 6 BK 6 BK RD BK BK 1 PU RD M1 M4 M2 R1 M2 6 3 BL M1 4 M3 BK 2 PU R WH YL BK 3 BL BK 5 M2 RD RD BL BL 2 WH RD 6 7 7 7 YL 8 RD BK RD 8 9 YL BL BK 9 8 RD 9 9 L1 L2 L1 ONE(1)ELEMENTROWS L2 L1 L2 L1 L2 TWO(2)ELEMENTROWS THREE(3)ELEMENTROWS FOUR(4)ELEMENTROWS L1 L2 L1 L2 AFTERINSTALLINGOPTIONALHEATKIT, MARKA"X"INTHE PROVIDEDABOVE. MARKACCORDINGTONUMBEROFHEATERELEMENTROWSINSTALLED NOMARKINDICATESNOHEATKITINSTALLED TO CONDENSER *SEE NOTE7 LOWVOLTAGE FIELDCONNECTION BOX YCON R C O TO THERMOSTAT 208/240VOLTS W1 C Y1 Y/Y2 G W2 W2 R RD PL1 2 PL2 2 SEENOTE8 BK YL OR FORHEAT PUMPS ONLY RD BL BR WH BL PU YL BR RD GR PL1 1 2 3 4 5 6 7 8 9 PL2 1 2 3 4 5 6 7 8 9 EQUIPMENTGROUND USECOPPER WIRE 1 1 PL1 1 PL2 TOLOWVOLTAGE TERMINALBOARD EM 2 3 TR BL RD J1 O R Y1 R 24 VAC W2 C O THERMOSTATS OTC OT1 OT 2 C W1 HEATER G Y1 HUMIDISTAT HUM Y/Y2 DS1 J2 J3 E\W1 ED PJ4 BL RD OU TDO OR W2 W2 VSTB BR W/W 2 W1 PJ2 PJ6 WH BL CONDENSER HEATPUMP OT1 R YCON COM O OT2 HUM PN. B1368270REV.A RD YL WH 240 1 4 208 2 24V BL RD 5 5 24VOLT 4 TR BK 3 COM BR 5 BR BL RD R EQUIPMENTGROUND USECOPPER WIRE WH W1 PJ2 PJ6 RD HUM BL OT 2 OT 1 YCON IN4005 DIODE PJ4 OT C O W W2 Y1 E W1 NOTEDIODE ON VSTB Y Y2 G C *SEENOTE7 SEENOTE2 SEENOTE3 BK PL2 SEE NOTE4 SEENOTE5 W2 BR OR 4 6 PL2 PL2 SEENOTE1 PU GR YL COLORCODE RD BL BR WH RD WH BK RD YL BL GR EQUIPMENTGROUND USECOPPER WIRE WHITE BLACK RED YELLOW BLUE GR PU BR 0R PK WIRINGCODE GREEN PURPLE BROWN ORANGE PINK FACTORYWIRING HIGHVOLTAGE LOWVOLTAGE FIELDWIRING HIGHVOLTAGE LOWVOLTAGE COMPONENTCODE EM PL PJ2,PJ4,PJ6 VSTB FL EVAPORATOR MOTOR PLUG PROGRAMJUMPER VARIABLE SPEED TERMINALBOARD FUSELINK TL HTR R TR THERMALLIMIT HEATELEMENT RELAY TRANSFORMER EM COPPER POWER SUPPLY (SEERATINGPLATE) CONTROLSSHOWNWITHUTILITIESIN"ON"POSITIONANDTHERMOSTATIN"OFF"POSITION. NOTES: 1.FORHEATPUMPAPPLICATIONSREMOVE ORANGE JUMPERWIREBETWEENO&Y1. 2.FORTWOSTAGEELECTRIC HEATAPPLICATIONSCUT PJ4.(USEONLYON15&20KWMODELS). 3.FOROUTDOORTHERMOSTATOPERATIONOFSECONDSTAGEHEAT,CUTPJ2 &ADD OT18-60TOOTC&OT2. 4.FORSINGLESTAGECOOLINGAPPLICATIONSCONNECTTHERMOSTATTOY/Y2ONLY, TAPEORREMOVEY1 CONNECTION. CONNECTCONDENSINGUNITTOYCON& C. 5.WHENHUMIDSTATISPROVIDEDCUTPJ6.THERMOSTATOPENSONHUMIDITYRISE. 6.REDWIRESTOBE ONTRANSFORMER TERMINAL3 FOR240 VOLTSANDON TERMINAL2 FOR208 VOLTS. 7.SEECOMPOSITEWIRINGDIAGRAMSIN INSTALLATION INSTRUCTIONSFORPROPERLOWVOLTAGE CONNECTIONSAND DETAILSONCOMPATIBLETHERMOSTATSANDTHEIRCONNECTIONS. 8.DISCARDORIGINAL"PL1"PLUGCONNECTORWHENINSTALLINGOPTIONALHEATKIT. 0140A00041-B Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 36 RD BK M2 M1 C PU WH BL BK RD BK BL NO NC EBTDR COM GR RD 9 8 7 6 5 4 3 2 1 BK L1 RD L2 FL FL BK M2 M1 BK RD R M4 M3 PU WH BL BK RD BK RD TWO (2) ELEMENT ROWS RD HTR1 TL HTR2 TL 9 8 7 6 5 4 3 2 1 L1 BK RD L2 BK L2 RD M2 M2 M1 YL R2 BL RD BK WH PU BR RD BL BK 9 8 7 6 5 4 3 2 1 THREE (3) ELEMENT ROWS RD YL R1 M4 M3 RD BK HTR2 TL HTR1 TL HTR3 TL M1 BK L1 YL FL FL FL L1 BK RD L2 IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NEC ESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. BL RD RD GR RD CR BL RD WH BR A 7 BL B 1 4 BL SEE NOTE 3 RD PLF PLM RD TERMINAL BLOCK SHOWN FOR 50HZ MODELS ONLY R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 SEE NOTE 2 BK 1 1 BK L1 RD BK RD 2 2 RD L2 C BK 3 3 BL 5 1 24V 2 BL 4 4 GRD RD 4 3 RD BR 5 5 240 RD BK BL TR 7 7 BL 89 8 C L GN EM 1 234 5 SEE NOTE 4 SEE NOTE 1 WH 6 6 9 EQUIPMENT GROUND EQUIPMENT GROUND USE COPPER OR ALUMINUM USE COPPER WIREWIRE TR 5 5 3 4 PLF A FL TR PLF PLM 7 FUSE LINK L1 CR TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE 2 TL THERMAL LIMIT HTR HEAT ELEMENTS Notes: 1) Red wires to be on transformer terminal "3" for 240 volts and on terminal "2" for 208 volts. 2) See composite wiring diagrams in installation instructions for proper low voltage wiring connections. 3) Confirm speed tap selected is appropriate for application. If speed tap needs to be changed, connect red wire from terminal 4 of CR relay to appropriate tap at TB 4) Brown and white wires are used with Heat Kits only. EVAPORATOR MOTOR TERMINAL BOARD RELAY CONTROL RELAY ELECTRONIC BLOWER TIME DELAY RELAY COMPONENT CODE EM TB R CR EBTDR B SEE NOTE 1 L2 PLM 2 PLF R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 6 24V 2 COLOR CODE 4 1 EM C L GN GR GREEN BK BLACK PU PURPLE RD RED YL YELLOW BR BROWN WH WHITE BL BLUE 1 PLF 1 PLM L1 208/240 VOLTS FL HTR1 TL HTR3 TL HTR2 TL M2 4 L2 RD BL BK PU M6 M5 BL YL BL R2 M8 M7 RD BK WH BR RD BL BK C 1 2 3 4 5 G C EM XFMR-C XFMR-R R 1 9 8 7 6 5 4 3 2 NO NC 0140A00034 EBTDR COM FOUR (4) ELEMENT ROWS RD YL R1 M4 M3 BK RD HTR4 TL M1 BK FL FL FL BL YL NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEAT ER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. ONE (1) ELEMENT ROWS RD G XFMR-C XFMR-R R L2 BK R HTR1 TL COPPER OR ALUMINUMSUPPLY COPPER POWER POWER SUPPLY (SEE RATING (SEE RATING PLATE)PLATE) USE 75°C FIELDFIELD WIRE WIRE USEMIN. MIN. 75°C GR BL L1 BK FL WIRING DIAGRAMS ASPF******AA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 37 BK M2 M1 WH RD BK ONE (1) ELEMENT ROWS RD PU BL BK 9 8 7 6 5 4 3 2 1 PLM BK L1 RD L2 FL BK M2 BK RD R M1 M4 M3 PU WH BL BK RD RD BK 9 8 7 6 5 4 3 2 1 PLM TWO (2) ELEMENT ROWS RD HTR1 TL HTR2 TL L1 BK RD L2 BK L2 RD M2 BK M2 M4 R2 WH PU BR RD BL BK 9 8 7 6 5 4 3 2 1 PLM THREE (3) ELEMENT ROWS RD YL R1 M1 M3 RD BL RD HTR2 TL YL BK HTR1 TL HTR3 TL M1 BK L1 YL FL FL FL L1 BK RD L2 FL L1 YL BL HTR3 TL HTR2 TL HTR1 TL M2 L2 RD BL BK M6 M5 PU BL YL R2 M8 M7 BL RD BK WH BR RD BL BK FOUR (4) ELEMENT ROWS RD YL R1 M4 M3 BK RD HTR4 TL M1 BK FL FL FL 9 8 7 6 5 4 3 2 1 PLM WH RD IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. COPPER OR ALUMINUM COPPER POWER SUPPLY POWER SUPPLY (SEE(SEE RATING RATINGPLATE) PLATE) USE MIN. 75° FIELD WIRE USE MIN. 75°C CFIELD WIRE RD GR BL RD BR GR CR RD WH 3 1 BL 5 2 4 SEE NOTE 3 BL WH PU PLF PLM TERMINAL BLOCK SHOWN FOR 50HZ MODELS ONLY R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 SEE NOTE 2 RD BK RD 2 2 C BK 3 3 BL RD BK RD L2 1 1 BK L1 2 24V 1 5 BL 4 4 GRD 4 3 WH 6 6 RD BK FUSE HOLDER BL TR 240 7 7 BL 8 8 9 9 C L GN EM 123 45 OR BR YL WH PU SEE NOTE 4 SEE NOTE 1 BL RD BR 5 5 EQUIPMENT GROUND EQUIPMENT GROUND USE COPPER OR ALUMINUM WIRE USE COPPER WIRE 4 6 24V 2 5 5 3 4 PLF 3 SEE NOTE 1 1 COLOR CODE WIRING CODE 2 2 CR 4 5 Notes: 1) Red wires to be on transformer terminal "3" for 240 volts and on terminal "2" for 208 volts. 2) See composite wiring diagrams in installation instructions for proper low voltage wiring connections. 3) Confirm speed tap selected is appropriate for application. If speed tap needs to be changed, connect purple wire from terminal 4 of CR relay to appropriate tap at TB 4) Brown and white wires are used with Heat Kits only. TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE EVAPORATOR MOTOR TR TERMINAL BOARD PLF RELAY PLM FL CONTROL RELAY TL ELECTRONIC BLOWER TIME HTR DELAY RELAY COMPONENT CODE GREEN PURPLE BROWN WHITE L2 PLM 2 PLF R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 1 EM C L GN GR BK BLACK RD RED PU YL YELLOW BR BL BLUE WH TR EM TB R CR EBTDR 1 PLF 1 PLM L1 208/240 VOLTS 1 2 3 4 5 0140A00037 REV B C EM NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. L2 BK R HTR1 TL FL FUSE HOLDER 38 L1 BK FL WIRING DIAGRAMS ASPF******BA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WIRING DIAGRAMS ASPF******CA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FL TL FL FL FL TL HTR1 FL TL HTR1 FL TL HTR1 HTR2 FL TL HTR2 FL BK BK BK RD 1 TL RD HTR3 FL BK RD RD PU RD M1 M1 WH M2 RD 4 M3 M3 5 M4 WH 6 BK RD WH M4 5 R1 M5 M7 M6 M8 3 RD BL R2 BR RD WH 6 7 YL 8 RD 8 4 5 BK BK 6 BL BK BK RD 9 L1 M3 M2 YL 7 8 M1 7 BK RD BR 6 RD 7 BK RD R2 BK RD BL YL BK BK BK BL 4 M2 R1 1 2 3 RD BL M1 M4 M2 BK PU BL R 5 M2 BK M1 1 PU 3 BL BK 4 R YL PU 3 BL 2 YL RD 2 BL YL TL HTR4 1 2 BK RD TL HTR3 BK BK TL BK TL HTR2 HTR1 FL 9 8 RD 9 9 L2 L1 L1 L2 ONE (1) ELEMENT ROWS L2 L1 L2 TWO (2) ELEMENT ROWS L1 L2 L1 L2 FOUR (4) ELEMENT ROWS THREE (3) ELEMENT ROWS NOTE:WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. 208/240VOLTS EQUIPMENT GROUND USE COPPER WIRE GRD SEE NOTE 2 R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 L1 L2 L1 L2 1 PLM 2 PLM EM PLM 1 2 3 4 5 6 7 8 9 PLF 1 2 3 4 5 6 7 8 9 BK RD BL BR WH 1 PLF LGN PLF 2 RD GR SEE NOTE 1 SEE NOTE 4 BR 1 2 3 4 24V 5 5 TR WH 3 FUSE HOLDER BL RD WH 6 5 2 1 4 CR 4 PLF 1 2 3 4 5 PU CR BK 4 WH RD 2 5 1 3 SEE NOTE3 SEE NOTE 1 C 1 2 3 R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 240 COLOR CODE TR GR 5 24V BL BL RD BK RD YL BL WH PU FUSE HOLDER OR BR YL 12 345 COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 75° C FIELD WIRE EM BK GR BLACK PU RED YELLOW BR WH BLUE GREEN PURPLE BROWN WHITE COMPONENTCODE EM TB R CR EBTDR C L GN RD IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. WIRING CODE 4 BL BL BL RD C RD BK RD EM EVAPORATOR MOTOR TERMINAL BOARD RELAY CONTROL RELAY ELECTRONIC BLOWER TIME DELAY RELAY FACTORY WIRING HIGH VOLTAGE LOWVOLTAGE FIELD WIRING HIGH VOLTAGE LOWVOLTAGE TR PLF PLM FL TL HTR TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS BL NOTES: 1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 280 VOLTS. 2) SEE COMPLETE WIRING DIAGRAMS ININSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 3) CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4 OF CR RELAY TO APPROPRIATE TAP AT TB 4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. 0140A00040-D Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 39