Download Python Service Manual - Red-D
Transcript
F-12 TROUBLESHOOTING & REPAIR INPUT RECTIFIER TEST WARNING Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD). DESCRIPTION This test will help determine if the input rectifier has “shorted” or “open” diodes. MATERIALS NEEDED Analog voltmeter/ohmmeter (multimeter) Phillips head screw driver Wiring diagram This procedure takes approximately 15 minutes to perform. PRO-CUT 80 F-12