Download Lightolier F7000-15 User's Manual

Transcript
Lighting Systems
1BHFPG
F7000-15
'4FSJFT-JHIU5-PVWFS4PMJE4JEFT8BMM.PVOU
3.25”
(8.26cm)
5
1
4
3.620”
(9.19cm)
.750“
(1.91cm)
1.63”
(4.14cm)
1.304”
(3.31cm)
3.95” (10.03cm)
6. Louver Shielding
Ordering Information
Family
FW7
Series
3
3 = Block
Type
4
4 = Louver
Lamps
Color
Wattage
Voltage
Length
1
1 = 1 Lamp
AL = Aluminum
WH = White
Complete Ordering Instructions below.
1 = 28W
2 = 54W
3 = 28W Dimming
4 = 28W EM
5 = 54W Dimming
6 = 54W EM
1 = 120v
2 = 277v
4 = 4’ (121.92cm)
8 = 8’ (243.84cm)
Features
Finish
1. Housing: Single piece of high purity extruded aluminum, a portion from
recycled material.
2. Housing End: Die-cast aluminum, welded in place.
3. End Cap: Die-cast aluminum. Encloses the end of the run.
4. Lamps: F28T5 or F54T5HO as specified. By others. Installed from the ceiling
side of the luminaire.
5. Ballast: Electronic. Meets ANSI starting, end-of-life protection and sound
rating specifications. Low THD.
6. Shielding: Integral, regressed flat louver blades punched and formed from
fixture housing, finished to match, no light leaks. Blades are .56” (1.42cm) high
on .75” (1.91cm) centers.
Powder-coated, baked enamel, white or aluminum, as specified.
Electrical
Connections: Pre-wired with 18 gauge wires and polarized cannon plug connectors for simultaneous mechanical/electrical connection.
Emergency Battery Pack: 90 minute operation, 700 lumens for 54W and 520
lumens for 28W.
Dimming: Advance Mark X standard (no additional wires required); use compatible dimmer. Dimming ballasts using additional control wires (eg Lutron Hi-Lume
or ECO-10, Osram) can be used; consult factory and use X4 or X5 power feeds
with additional leads, as appropriate. Ballast not to exceed 1.25” (3.18cm) wide by
1.20” (3.05cm) high.
iGEN: F7000 accepts iGEN (DALI) with supplemental 2-wire control technology.
Use with X5 power feed.
Power Tray: Code-gauge, die-formed steel, pre-paint white enamel finish;
secured by quarter-turn fasteners for easy access to wiring. Holds ballasts, sockets, and wiring. Accepts ballasts up to 1.25” (3.18cm) wide by 1.20” (3.05cm) high.
Finish: Powder-coated, baked enamel, white or aluminum, as specified.
Mounting
Each module includes two wall-mounting brackets. Bracket hole pattern accommodates junction box (single gang box rotated 90 degrees) or other appropriate
mounting method using customer supplied fasteners.
Labels
UL, cUL and I.B.E.W.
Ordering Instructions
Individual Fixtures:
1. Order one MODULE.
2. Order one END SET.
Continuous Rows:
1. Order the appropriate number of MODULES for the complete run.
2. Order one END SET.
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Factory installed ballast disconnect allows the ballast to be disconnected from and
reconnected to incoming power under load without turning the entire circuit off.
"JSQPSU3PBE'BMM3JWFS."t
t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt '
Lighting Systems
1BHFPG
'4FSJFT-JHIU5-PVWFS4PMJE4JEFT8BMM.PVOU
Performance
ZONE
DEG.
0
160
170
180
120
80
90
90
100
110
70
50
60
405
40
10
20
30
REPORT NO.: ITL54685.IES
LAMPS: 1-F54T5
LUMENS: 5000 each
EFFICIENCY: 77.9%
CAT. NO.: F7341WH214
45
67
90
631
621
562
485
386
268
179
99
52
12
1
73
293
419
529
603
646
680
699
705
702
631
618
540
438
321
202
120
76
40
9
0
37
153
279
404
506
589
651
689
704
702
80%
CANDELAS
130
140
0
5
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
22
631
640
706
780
674
401
212
105
49
13
3
39
269
544
771
801
812
797
742
704
702
631
636
672
710
638
390
203
97
50
13
2
44
285
553
742
780
799
786
736
705
702
631
631
618
590
545
382
193
95
49
11
1
52
295
543
642
711
748
741
722
707
702
ROOM CAVITY RATIO
150
203
810
0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
CANDLEPOWER
CANDLEPOWER CURVE
608
F7000-15
50
81
70
62
55
48
44
39
35
32
29
27
0
1
2
3
4
5
6
7
8
9
10
30
81
67
58
49
43
37
33
29
27
24
21
70%
WALL REFLECTANCE
50 30 10
72 72 72
64 62 59
56 52 49
49 45 42
44 39 35
40 34 30
35 30 27
32 27 24
29 24 21
27 22 18
25 20 16
10
81
66
54
46
39
33
29
26
22
20
18
50%
50
57
50
45
40
36
32
29
27
24
22
20
30
57
49
43
37
32
29
25
23
20
18
16
10
57
48
40
34
29
26
22
20
17
15
14
20% FLOOR CAVITY REFLECTANCE
DISTRIBUTION
Zone
Lumens
0 - 90
1246
90 - 180
2661
0 - 180
3907
% Lamp
24.7
53.2
77.9
%Luminaire
32.0
68.0
100.0
Fixture Lengths & Mounting Reflected (Plan View)
2'-8"
(81.28cm)
6'-8" (203.20cm)
16.00" (40.64cm)
4'-3" (129.54cm)
8'-3" (251.46cm)
6'-8" (203.20cm)
1'-4"
(40.64cm)
2'-8"
(81.28cm)
3/4"
(1.91cm)
JOINING DETAIL
GAP BETWEEN FIXTURES
12'-3" (373.38cm)
6'-8" (203.20cm)
1'-4"
(40.64cm)
6'-8" (203.20cm)
16'-3" (495.30cm)
1-1/2"
(3.81cm)
6'-8" (203.20cm)
1'-4"
(40.64cm)
6'-8" (203.20cm)
1'-4"
(40.64cm)
2'-8"
(81.28cm)
20'-3" (617.22cm)
3/8" (0.95cm)
END OF ROW DETAIL
Recommended mounting is a single gang outlet box rotated 90 degrees at the
feed point. Remaining mounting points could be outlet boxes as well, or a couple
of holes per mounting point spaced 3-1/4” (8.26cm) at 1-3/4” (4.45cm) above the
bottom of fixture.
Mounting Accessories
Wall Mount End Set
FW7EWH = White
FW7EAL = Aluminum
Job Information
Type:
"JSQPSU3PBE'BMM3JWFS."t
t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt '