CPC C ommercial 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Cooling Capacity: 90,000 — 118,000 BTU/h up to 11.5 EER Standard Features • • • • • • • • • • • • • R-410A chlorine-free refrigerant High-efficiency scroll compressor Copper tube / aluminum fin coils Contactor with lugs High- and low-pressure switches High-capacity, steel-cased filter dryer Heater kits with single-point entry 24-volt terminal strip Convertible Easy to service Built-in filter rack with standard 2” filters Bottom utility entry AHRI Certified; ETL Listed Contents Nomenclature...................................................................................................2 Product Specifications.................................................................................3 Airflow Data........................................................................................................7 Heat Kit Electrical Data . .......................................................................... 11 Expanded Cooling Data........................................................................... 16 Dimensions...................................................................................................... 26 Wiring Diagrams ......................................................................................... 30 Accessories...................................................................................................... 34 Cabinet Features • Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish • Full Perimeter Rail * Complete warranty details available from your local dealer or at www.goodmanmfg.com. SS-CPC90-150 www.goodmanmfg.com 6/11 Supersedes 3/11 Product Specifications Nomenclature Brand C C 1 P 2 C 3 150 4,5,6 Commercial 3 10 B 11 X 12 X 13 X 14 X A B C F Configura;on P Packaged Unit Applica;on C Cooling G Gas Heat H Heat Pump Nominal Gross Cooling Capacity 036 3 Tons 102 048 4 Tons 120 060 5 Tons 150 072 6 Tons 180 090 7½ Tons 240 045 7,8,9 M X A B 8½ Tons 10 Tons 12½ tons 15 Tons 20 Tons C D Nominal Hea;ng Capacity CPG 045 45,000 BTU/h 090 90,000 BTU/h 115 115,000 BTU/h 140 140,000 BTU/h 210 210,000 BTU/h 350 350,000 BTU/h 400 400,000 BTU/h Voltage 1 208V 1-‐Phase 2 220/240V 1-‐Phase 50 Hz 3 208/230V 3-‐Phase CPC/CPH (Factory-‐Installed Electric Heat) XXX No Heat 010 10 kW 030 30 kW 015 15 kW 031 30 kW 016 15 kW 045 45 kW 018 18 kW 046 45 kW 020 20 kW 060 60 kW 025 25 kW 075 75 kW 4 460V 3-‐Phase 5 380/415V 3-‐Phase 50 Hz 7 575V 3-‐Phase J S T X A B D H Factory-‐Installed Op;ons No Op:ons Non-‐powered convenience outlet Powered convenience outlet Low-‐ambient kit Non-‐powered convenience outlet; Low-‐ambient kit Powered convenience outlet; Low-‐ambient kit Factory-‐Installed Op;ons Standard Aluminized Heat Exchanger Condenser Coil Hail Guard Condenser Coil Hail Guard Treated Condenser Coil (UltraGold) Condenser Coil Hail Guard Stainless Steel Heat Exchanger Condenser Coil Hail Guard Treated Condenser Coil (UltraGold) Stainless-‐Steel Heat Exchanger Treated Condenser Coil (UltraGold) Stainless-‐Steel Heat Exchanger Treated Condenser Coil (UltraGold) Stainless-‐Steel Heat Exchanger Factory-‐Installed Op;ons No Op:ons Downflow Economizer Supply Fan/Drive Type/Motors Belt Drive Direct Drive High-‐Sta:c Belt Drive (Factory-‐Installed) Factory-‐Installed Op;ons • • • • • • • • • Condenser Hail Guards: Louvered metal guards help protect the condenser coil from damage from hail and debris. Available as a factory-‐installed op:on on 3-‐ to 12½-‐ton units. Hail guards are standard on 15-‐ and 20-‐ton units. Stainless-‐Steel Heat Exchanger (CPG units only): A tubular heat exchanger made of 409-‐type stainless steel is installed in the unit. Ultra-‐Gold Condenser Coil: Offers increased corrosion resistance of the condenser coil. Low-‐Ambient Kit: Allows for cooling opera:on at lower outdoor temperatures. On the 3-‐ to 6-‐ton units, cooling opera:on is extended from 60°F ambient temperature to 35°F outside air temperature. On 7½-‐ to 20-‐ton units, cooling opera:on is extended from 35°F ambient temperature to 0°F outside air temperature. Economizers (Downflow): Based on air condi:ons, can provide outside air to cool the space. High Sta:c Kits: Provides airflow in higher sta:c applica:ons. Electric Heat Kits (CPC and CPH units only): Available in all voltage op:ons. Non-‐powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. 2www.goodmanmfg.com SS-CPC90-150 Product Specifications Product Specifications — 7½ Tons A Models B Models CPC090 XXX3BXXX CPC090 XXX4BXXX CPC090 XXX3BXXX CPC090 XXX4BXXX CPC090 XXX7BXXX Total BTU/h 90,000 90,000 90,000 90,000 90,000 Sensible BTU/h 65,700 65,700 64,000 64,000 64,000 11.5 / 11.5 11.5 / 11.5 11.5 / 11.5 11.5 / 11.5 11.5 / 11.5 Cooling Capacity EER / IEER Decibels AHRI Reference #s 82.0 82.0 82.0 82.0 82.0 3000986 3000986 3620223 3620223 3620223 Belt Drive Belt Drive Belt Drive Belt Drive Belt Drive 3,000 3,000 3,000 3,000 3,000 7.8 3.9 5.0 2.5 2.3 2.0 / 1725 2.0 / 1725 1.5 / 1745 1.5 / 1745 1.5 / 1725 Evaporator Motor / Coil Motor Type Indoor Nominal CFM Indoor Motor FLA (Cooling) Horsepower / RPM Piston Size (Cooling) Filter Size (Qty) Drain Size (NPT) R-410A Refrigerant Charge Cir #1 & #2 0.076 0.076 0.078 0.078 0.078 (4) 16”x24”x2” (4) 16”x24”x2” (4) 16”x20”x2” (4) 16”x20”x2” (4) 16”x20”x2” ¾” ¾” ¾” ¾” ¾” 215 oz. 215 oz. 175 oz. 175 oz. 175 oz. Evaporator Coil Face Area (ft²) 10.2 10.2 8.9 8.9 8.9 Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 4 / 16 4 / 16 # of Wheels (D x W) 1 (15” x 12”) 1 (15” x 12”) 1 (15” x 12”) 1 (15” x 12”) 1 (15” x 12”) Motor Sheave / Blower Sheave VL40 / AK74 VL40 / AK74 VL40 / AK74 VL40 / AK74 VL40 / AK74 AX51 AX51 AX51 AX51 AX51 Belt Drive Evap Fan Data Belt Condenser Fan / Coil Quantity of Condenser Fan Motors 2 2 2 2 2 ¼ - 1090 ¼ - 890 ¼ - 1075 ¼ - 890 ¼ - 1,075 Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal CFM 7,600 7,600 7,600 7,600 7,600 Face Area (ft²) 32.4 32.4 26.5 26.5 26.5 Rows Deep / Fins per Inch 2 / 20 2 / 20 2 / 22 2 / 22 2 / 22 2 / Scroll 2 / Scroll 2 / Scroll 2 / Scroll 2 / Scroll 1 1 1 1 1 Voltage-Phase-Frequency 208/230-3-60 460-3-60 208/230-3-60 460-3-60 575-3-60 Quantity of Compressors 2 2 2 2 2 13.1 / 83.1 6.1 / 41.0 13.1 / 83.1 6.1 / 41.0 4.4 / 33.0 Horsepower - RPM Compressor Quantity / Type Stage Electrical Data Compressor RLA / LRA Max External Static Outdoor Fan HP / RLA Total Unit Amps 1.5” 1.5” 1.0” 1.0” 1.0” (2) ¼ / 1.4 (2) ¼ / 0.8 (2) ¼ / 1.4 (2) ¼ / 0.8 (2) ¼ / 0.6 36.9 17.7 34.0 16.3 12.3 Min. Circuit Ampacity¹ 40 19 37.3 17.8 13.4 Max. Overcurrent Protection (amps)² 50 25 50 20 15 Entrance Control Voltage Locating Dimple Locating Dimple Locating Dimple Locating Dimple Locating Dimple Operating Weight (lbs) 1110 1110 975 975 975 Ship Weight (lbs) 1150 1150 1000 1000 1000 Entrance Power Supply ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-CPC90-150 www.goodmanmfg.com 3 Product Specifications Product Specifications — 8½ Tons CPC102 XXX3BXXX CPC102 XXX4BXXX CPC102 XXX7BXXX 102,000 102,000 102,000 Cooling Capacity Total, BTU/h Sensible BTU/h EER / IEER Decibels 70,380 70,380 70,380 11.3 / 11.2 11.3 / 11.2 11.3 / 11.2 83 83 83 3620220 3620220 3620220 Belt Drive Belt Drive Belt Drive 3,400 3,400 3,400 7.8 3.9 2.3 Horsepower - RPM 1725 1725 1725 Piston Size (Cooling) 0.08 0.08 0.08 (4) 16” x 20” x 2” (4) 16” x 20” x 2” (4) 16” x 20” x 2” ARI Reference #s Evapoartor Motor / Coil Motor Type Indoor Nominal CFM Indoor Motor FLA (Cooling) Filter Size (Qty) Drain Size (NPT) R-410A Refrigerant Charge Cir #1 & #2 Evaporator Coil Face Area (ft2) 3/4" 3/4" 3/4" 180 oz. 180 oz. 180 oz. 8.9 8.9 8.9 4 / 16 4 / 16 4 / 16 # of Wheels (D x W) 1 (15" x 12") 1 (15" x 12") 1 (15" x 12") Motor Sheave / Blower Sheave VL40 / AK74 VL40 / AK74 VL40 / AK74 AX51 AX51 AX51 2 2 2 Rows Deep / Fins per Inch Belt Drive Evap Fan Data Belt Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM 1/4" - 1,090 1/4" - 890 1/4" - 1,075 Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4 Outdoor Nominal CFM 7,600 7,600 7,600 Face Area (ft2) 13.25 13.25 13.25 Rows Deep / Fins per Inch 2 / 22 2 / 22 2 / 22 2 / Scroll 2 / Scroll 2 / Scroll 1 1 1 575 / 3 / 60 Compressor Quantity / Type Stage Electrical Data / Static Voltage / Phase / Frequency 230 / 3 / 60 460 / 3 / 60 Quantity of Compressors 2 2 2 Compressor RLA / LRA ea. 14.5 / 98 6.3 / 55 6.0 / 41 Standard Max Static 1" 1 1 Outdoor Fan FLA ea. 1.4 0.8 0.6 Total Unit Amps 39.6 18.1 15.5 Min. Circuit Ampacity¹ 43.2 19.7 17 50 25 20 Locating Dimple Locating Dimple Locating Dimple Max. Overcurrent Protection (amps)² Entrance Power Supply Entrance Control Voltage Operating Weight (lbs) 975 975 975 Ship Weight (lbs) 1000 1000 1000 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. 4www.goodmanmfg.com SS-CPC90-150 Product Specifications Product Specifications — 10 Tons CPC120 XXX3BXXX CPC120 XXX4BXXX CPC120 XXX7BXXX 118,000 118,000 118,000 Cooling Capacity Total BTU/h Sensible BTU/h EER / IEER Decibels 87,300 87,300 87,300 11.5 / 11.2 11.5 / 11.2 11.5 / 11.2 83.0 83.0 83.0 3023833 3023833 3023833 Belt Drive Belt Drive Belt Drive 4,000 4,000 4,000 7.8 3.9 2.7 Horsepower - RPM 2.0/1725 2.0/1725 2.0/1725 Piston Size (Cooling) 0.086 0.086 0.086 (4) 16” x 24” x 2” (4) 16” x 24” x 2” (4) 16” x 24” x 2” ARI Reference #s Evaporator Motor / Coil Motor Type Indoor Nominal CFM Indoor motor FLA (Cooling) Filter Size (Qty) Drain Size (NPT) R-410A Refrigerant Charge Cir #1 & #2 ¾” ¾” ¾” 220 oz. 220 oz. 220 oz. Evaporator Coil Face Area (ft²) 10.2 10.2 10.2 Rows Deep / Fins per Inch 4 / 14 4 / 14 4 / 14 # of Wheels (D x W) (1) 15” x 15” (1) 15” x 15” (1) 15” x 15” Motor Sheave / Blower Sheave VL40 / AK74 VL40 / AK74 VL40 / AK74 AX51 AX51 AX51 2 2 2 Belt Drive Evap Fan Data Belt Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075 Fan Diameter / # Fan Blades 22 / 3 22 / 3 22 / 3 Outdoor Nominal CFM 7,200 7,200 7,200 Face Area (ft²) 32.4 32.4 32.4 2/2 rows - 22 fpi 2/2 rows - 22 fpi 2/2 rows - 22 fpi 2 / Scroll 2 / Scroll 2 / Scroll 1 1 1 208-230/3/60 460/3/60 575/3/60 2 2 2 16/110.0 7.8/52.0 5.7/38.9 Rows Deep - Fins per Inch Compressor Quantity / Type Stage Electrical Data Voltage/Phase/ Frequency Quantity of Compressors Compressor RLA / LRA ea. Standard Max Static 2.0” 2.0” 2.0” Outdoor Fan RLA ea. 2.40 1.20 0.89 Total Unit Amps 45 22 16 Min. Circuit Ampacity¹ 49 24 17 60.0 30 20 Entrance Control Voltage Locating Dimple Locating Dimple Locating Dimple Operating Weight (lbs) 1135 1135 1135 Ship Weight (lbs) 1175 1175 1175 Max. Overcurrent Protection (amps)² Entrance Power Supply ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-CPC90-150 www.goodmanmfg.com 5 Product Specifications Product Specifications — 12½ Tons Cooling Capacity Total, BTU/h Sensible BTU/h EER / IPLV Decibels ARI Reference #s Evapoartor Motor / Coil Motor Type Indoor Nominal CFM Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size Drain Size (NPT) R-410A Refrigerant Charge Cir #1 & #2 Evaporator Coil Face Area (ft2) Rows Deep / Fins per Inch Condenser Fan / Coil Quantity of condenser Fan Motors Horsepower - RPM Fan Diameter / # Fan Blades Outdoor Nominal CFM Face Area (ft2) Rows Deep / Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave / Blower Sheave Belt Compressor Quantity / Type Stage Compressor RLA / LRA ea. Electrical Data / Static Voltage / Phase / Frequency Outdoor Fan FLA ea. Total Unit Amps Min. Circuit Ampacity1 Max. Overcurrent Protection (amps)2 Entrance Power Supply Entrance Control Voltage Operating Weight (lbs) Ship Weight (lbs) CPC150XXX 3BXXX CPC150XXX 4BXXX CPC150XXX 7BXXX 146,000 102,200 11.0 / 11.2 83 3542680 146,000 102,200 11.0 / 11.2 83 3542680 146,000 102,200 11.0 / 11.2 83 3542680 Belt Drive 5,000 9.4 3.0 - 1,725 0.096 (4) 20" x 25" x 2" ¾" 285 oz. 14.7 4 / 15 Belt Drive 5,000 4.7 3.0 - 1,725 0.096 (4) 20" x 25" x 2" ¾" 285 oz. 14.7 4 / 15 Belt Drive 5,000 4.2 3.0 - 1,725 0.096 (4) 20" x 25" x 2" ¾" 285 oz. 14.7 4 / 15 2 ⅓ - 1,075 22/3 7,200 35.3 2/3 rows 15 fpi 2 ⅓ - 1,075 22/3 7,200 35.3 2/3 rows 15 fpi 2 ⅓ - 1,075 22/3 7,200 35.3 2/3 rows 15 fpi (1) 15" x 15" VL40 / AK66 AX49 (1) 15" x 15" VL40 / AK66 AX49 (1) 15" x 15" VL40 / AK66 AX49 1 / Scroll Single 22.4 / 149 1 / Scroll Single 10.6 / 75 1 / Scroll Single 7.7 / 54 208-230/3/60 2.4 59 65 80 460/3/60 1.2 28 31 40 575/3/60 0.9 21.4 23 30 Locating Dimple Locating Dimple Locating Dimple 1275 1300 1275 1300 1275 1300 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. 6www.goodmanmfg.com SS-CPC90-150 Product Specifications Airflow Data — 7½ Tons Standard Belt Drive — Down Shot ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP 4 RPM BHP CFM 3617 704 1.07 3293 653 0.84 3541 749 1.15 3179 704 0.88 2757 656 0.66 2606 710 0.71 0.1 0.3 0.5 0.7 0.9 3303 890 1.41 1.1 2838 897 1.23 3447 798 1.23 3049 754 0.94 3400 848 1.33 2950 798 1.01 2474 754 0.75 2871 848 1.11 2408 804 0.82 RPM 5 CFM BHP CFM RPM BHP High-Static Belt Drive — Down Shot (for A Models only) ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 BHP CFM RPM 5 BHP 0.9 1.1 1.3 DO NOT OPERATE 1.5 1.7 1.9 3381 1119 2.22 2.1 3089 1129 2.04 CFM RPM BHP 3401 909 1.51 3428 965 1.71 2943 915 1.3 3471 1015 1.9 3012 971 1.5 2423 920 1.12 2503 976 1.31 CFM RPM BHP CFM RPM BHP 3625 701 1.08 3309 660 0.86 3722 1063 2.25 3041 1023 1.67 3359 1075 2.04 2540 1031 1.5 2890 1080 1.78 Standard Belt Drive — Horizontal ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 BHP 0.1 0.3 3815 797 1.44 3468 747 1.11 3177 703 0.88 2796 663 0.68 3780 841 1.52 3405 803 1.23 3053 753 0.94 2608 709 0.68 2225 665 0.53 1.6 3327 847 1.29 2968 805 1.02 2423 758 0.73 2850 852 1.1 2352 807 0.8 BHP CFM RPM BHP 3447 902 1.54 3006 908 1.31 0.5 0.7 3687 885 5 0.9 3236 891 1.39 1.1 2713 896 1.17 High-Static Belt Drive — Horizontal (for A Models only) ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 BHP CFM RPM 5 0.9 1.1 1.3 1.5 1.7 DO NOT OPERATE 3388 1103 2.18 1.9 2959 1114 2.0 2.1 2527 1124 1.86 3514 1057 2.07 3036 1069 1.84 3486 1008 1.87 2949 1019 1.62 3398 956 1.65 2960 962 1.44 Notes : Assume dry coil with filter in place; CFM correction for wet coil = 3% Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could require a larger motor. Minimum rated SCFM is 350 per ton. SS-CPC90-150 www.goodmanmfg.com 7 Product Specifications Airflow Data — 8½ Tons Standard Belt Drive — Down Shot ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP 4 RPM BHP CFM 3467 701 1.04 3143 650 0.81 3391 746 1.12 3029 701 0.85 2607 653 0.63 2899 751 0.91 2456 707 0.68 0.1 0.3 0.5 0.7 0.9 3153 887 1.38 1.1 2688 894 1.20 3250 845 1.30 2721 845 1.08 3297 795 1.20 2800 795 0.98 RPM 5 CFM BHP CFM RPM BHP High-Static Belt-Drive — Down Shot ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 BHP CFM RPM 5 BHP 0.9 1.1 1.3 1.5 3572 1060 2.22 1.7 3209 1072 2.01 2740 1077 1.75 1.9 2.1 3256 1156 2.31 3231 1116 2.19 2939 1126 2.01 3321 1012 1.87 2891 1020 1.64 CFM RPM BHP 3251 906 1.48 2793 912 1.27 3278 962 1.68 2862 968 1.47 CFM RPM BHP CFM RPM BHP 3475 698 1.05 3159 657 0.83 2646 660 0.65 CFM RPM BHP 3297 899 1.51 2856 905 1.28 Standard Belt Drive — Horizontal ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 BHP 0.1 0.3 0.5 5 3665 794 1.41 3318 744 1.08 3027 700 0.85 3630 838 1.49 3255 800 1.2 2903 750 0.91 2458 706 0.65 2818 802 0.99 BHP CFM RPM 0.7 3537 882 1.57 3177 844 1.26 0.9 3086 888 1.36 2700 849 1.07 1.1 2563 893 1.14 High-Static Belt-Drive — Horizontal ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 5 BHP 0.9 1.1 1.3 1.5 1.7 1.9 3188 1146 2.23 3238 1100 2.15 2809 1111 1.97 3364 1054 2.04 2886 1066 1.81 3336 1005 1.84 2799 1016 1.59 3248 953 1.62 2810 959 1.41 Notes : Assume dry coil with filter in place; CFM correction for wet coil = 3% Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could require a larger motor. Minimum rated SCFM is 350 per ton. 8www.goodmanmfg.com SS-CPC90-150 Product Specifications Airflow Data — 10 Tons Standard Belt-Drive — Down Shot ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP 2 BHP CFM 4632 781 1.76 4203 742 1.41 4488 825 1.85 4183 783 1.54 3733 748 1.23 3717 786 1.31 0.6 4442 880 2.02 4066 830 1.63 0.8 4001 885 1.77 3622 835 1.41 1 3603 890 1.55 BHP CFM RPM 4 RPM 0.2 0.4 RPM 3 CFM BHP CFM 5 RPM BHP CFM RPM BHP 3927 691 1.17 3510 658 0.9 3512 693 1 1.2 High-Static Belt-Drive — Down Shot ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 BHP 0.8 1 1.2 1.4 1.6 1.8 2 4050 1179 3.05 4438 1116 2.97 3956 1124 2.55 3473 1132 2.32 5 CFM RPM BHP CFM RPM BHP 4435 940 2.22 4078 886 1.82 3539 892 1.52 4462 997 2.47 4103 945 2.05 4513 1054 2.75 4127 1003 2.26 3568 950 1.71 4126 1064 2.52 3597 1008 1.92 3759 1069 2.25 Standard Belt-Drive — Horizontal ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP 4497 0.6 0.8 4564 873 780 BHP CFM RPM BHP CFM RPM 4562 736 1.58 4253 691 1.29 3893 642 1 1.7 4200 736 1.41 3735 691 1.06 3322 648 0.83 3689 741 1.18 CFM RPM BHP CFM RPM BHP 4602 884 2.13 4467 824 1.81 4221 784 1.55 2.06 4170 830 1.68 3677 785 1.29 3498 835 1.34 1 4129 875 1.81 1.2 3558 879 1.49 5 RPM 0.2 0.4 4 CFM BHP High-Static Belt-Drive — Horizontal ESP (“ W.C.) Turns Open 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 BHP 5 0.8 1 4749 940 2.44 4180 885 1.89 1.2 4251 945 2.12 3642 896 1.58 3744 951 1.8 1.4 1.6 DO NOT OPERATE 4443 1001 2.5 4587 1056 2.82 3971 1006 2.17 3342 1012 1.86 1.8 4760 1105 3.23 4071 1061 2.43 2 4364 1114 2.91 3579 1067 2.05 Notes : Assume dry coil with filter in place; CFM correction for wet coil = 3% Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could require a larger motor. Minimum rated SCFM is 350 per ton. SS-CPC90-150 www.goodmanmfg.com 9 Product Specifications Airflow Data — 12½ Tons Standard Belt Drive --- Down Shot ESP (" W.C.) Turns Open 0 CFM 1 BHP CFM 2 BHP 0.2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP 5378 2.35 4967 1.92 4710 1.59 4512 1.33 4319 1.40 4030 1.13 0.4 5514 2.92 5349 2.56 4750 1.97 4583 1.71 0.6 5204 2.69 4919 2.27 4488 1.81 4258 1.54 0.8 4830 2.42 4649 2.09 4019 1.55 1.0 4497 2.19 4264 1.86 High-Static Belt Drive --- Down Shot ESP (" W.C.) Turns Open 0 CFM 1 BHP CFM 2 BHP CFM 3 BHP 0.8 4 5 CFM BHP CFM BHP CFM BHP 5978 3.87 5691 3.38 5324 2.81 1.0 5947 4.16 5656 3.58 5376 3.12 4933 2.52 1.2 5708 3.93 5459 3.40 4950 2.79 4441 2.18 4525 2.45 1.4 5776 4.64 5510 4.07 5245 3.48 4844 2.88 1.6 5465 4.30 5199 3.74 4894 3.17 4404 2.54 1.8 5145 3.97 4871 3.41 4495 2.83 2.0 4805 3.63 4565 3.13 4142 2.55 2.2 4429 3.27 4233 2.85 Standard Belt Drive --- Horizontal ESP (" W.C.) Turns Open 0 CFM 1 BHP CFM 2 BHP CFM 3 BHP 0.2 4 5 CFM BHP CFM BHP CFM BHP 5570 2.27 4935 1.70 4584 1.36 4178 1.19 0.4 5871 3.20 5639 2.77 5307 2.31 4902 1.88 4637 1.55 0.6 5610 3.00 5358 2.57 5051 2.15 4603 1.72 4341 1.41 0.8 5391 2.83 5010 2.33 4799 2.00 4393 1.61 1.0 5078 2.59 4676 2.11 4448 1.79 1.2 4521 2.20 4226 1.83 High-Static Belt Drive --- Horizontal ESP (" W.C.) Turns Open 0 CFM 1 BHP CFM 2 BHP CFM 3 BHP CFM 4 BHP 0.8 1.0 1.2 1.4 5 CFM BHP CFM BHP 5858 3.51 5538 2.97 5894 3.85 5502 3.20 5282 2.78 5780 4.04 5570 3.55 5110 2.88 4869 2.47 4598 2.28 5900 4.49 5501 3.77 5312 3.33 4793 2.64 1.6 5860 4.76 5514 4.08 5257 3.54 4945 3.01 4382 2.34 1.8 5615 4.49 5315 3.88 5020 3.32 4504 2.66 2.0 5529 4.40 4906 3.49 4601 2.96 2.2 4938 3.78 4541 3.15 4222 2.65 Notes • Assume dry coil with filter in place; CFM correction for wet coil = 3% • Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Application • that exceed the above could require a larger motor. Minimum rated SCFM is 350 per ton. 10www.goodmanmfg.com SS-CPC90-150 Product Specifications Heat Kit Electrical Data (Blower Only, Heat Mode) — 7½ Tons (A Modles) Model and Heat Kit Usage CPC090XXX3BXXX EHK3-16 EHK3-30 EHK3-45 Model and Heat Kit Usage MCA¹ at 208 / 240V MOP² (amps) at 208 / 240V Actual kW at 240V Recommended Airflow Range 40 48 / 55 87 / 100 121 / 139 50 50 / 60 90 / 100 125 / 150 15 30 43 3000 - 3375 CFM 3000 - 3375 CFM 3000 - 3375 CFM MCA¹ at 480V MOP² (amps) at 480V Actual kW at 480V Recommended Airflow Range 19 27 50 70 25 30 50 70 15 30 43 3000 - 3375 CFM 3000 - 3375 CFM 3000 - 3375 CFM MCA¹ at 575V MOP² (amps) at 575V Actual kW at 575V Recommended Airflow Range 14 22 41 57 15 25 45 60 15 30 43 ------- CPC090XXX4BXXX EHK4-16 EHK4-30 EHK4-45 Model and Heat Kit Usage CPC090XXX7BXXX EHK7-16 EHK7-30 EHK7-45 ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device KW Correction Factors kW Correction Factor (for 1- & 3-Phase Units) Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 kW Correction Factor (for 480V Units) Supply Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage, use voltage² / 480² kW Correction Factor (for 575V Units) Minimum Airflow for Electric Heat Heater Size (kW) Minimum CFM 15 3,000 Supply Voltage 560 550 540 30 3,000 Correction Factor 0.95 0.91 0.88 43 3,000 Multiply rated kW by correction factor to get actual kW. SS-CPC90-150 www.goodmanmfg.com 11 Product Specifications Heat Kit Electrical Data (Blower Only, Heat Mode) — 7½ Tons (B Modles) Model and Heat Kit Usage CPC090XXX3BXXX EHK3-16 EHK3-30 EHK3-45 Model and Heat Kit Usage MCA¹ at 240V MOP² (amps) at 240V Actual kW at 240V Recommended Airflow Range 37 51 97 136 50 60 100 150 15 30 43 3000 - 3375 CFM 3000 - 3375 CFM 3000 - 3375 CFM MCA¹ at 480V MOP² (amps) at 480V Actual kW at 480V Recommended Airflow Range 18 26 48 68 20 30 50 70 15 30 43 3000 - 3375 CFM 3000 - 3375 CFM 3000 - 3375 CFM MCA¹ at 575V MOP² (amps) at 575V Actual kW at 575V Recommended Airflow Range 13 22 41 57 15 25 45 60 15 30 43 3000 - 3375 CFM 3000 - 3375 CFM 3000 - 3375 CFM CPC090XXX4BXXX EHK4-16 EHK4-30 EHK4-45 Model and Heat Kit Usage CPC090XXX7BXXX EHK7-16 EHK7-30 EHK7-45 ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device KW Correction Factors kW Correction Factor (for 1- & 3-Phase Units) Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 kW Correction Factor (for 480V Units) Supply Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage, use voltage² / 480² kW Correction Factor (for 575V Units) Minimum Airflow for Electric Heat Heater Size (kW) Minimum CFM 15 3,000 Supply Voltage 560 550 540 30 3,000 Correction Factor 0.95 0.91 0.88 43 3,000 Multiply rated kW by correction factor to get actual kW. 12www.goodmanmfg.com SS-CPC90-150 Product Specifications Heat Kit Electrical Data (Blower Only, Heat Mode) — 8½ Tons Model and Heat Kit Usage MCA¹ at 208 / 240V MOP² (amps) at 208 / 240V 43 50 CPC102XXX3BXXX Actual kW at 240V Recommended Airflow Range (Downshot) Recommended Airflow Range (Horizontal) EHK3-16 55 60 15 3400 - 3825 CFM 3400 - 3825 CFM EHK3-30 100 100 30 3400 - 3825 CFM 3400 - 3825 CFM EHK3-45 139 150 43 3400 - 3825 CFM 3400 - 3825 CFM MCA¹ at 480V MOP² (amps) at 480V Actual kW at 480V Recommended Airflow Range (Downshot) Recommended Airflow Range (Horizontal) CPC102XXX4BXXX 20 25 EHK4-16 27 30 15 3400 - 3825 CFM 3400 - 3825 CFM EHK4-30 50 50 30 3400 - 3825 CFM 3400 - 3825 CFM EHK4-45 70 70 43 3400 - 3825 CFM 3400 - 3825 CFM MCA¹ at 575V MOP² (amps) at 575V Actual kW at 575V Recommended Airflow Range (Downshot) Recommended Airflow Range (Horizontal) CPC102XXX7BXXX 17 20 EHK7-16 22 25 15 3400 - 3825 CFM 3400 - 3825 CFM Model and Heat Kit Usage Model and Heat Kit Usage EHK7-30 41 45 30 3400 - 3825 CFM 3400 - 3825 CFM EHK7-45 57 60 43 3400 - 3825 CFM 3400 - 3825 CFM ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device ^ - EHK Heater Kits above require a three-phase power supply KW Correction Factors kW Correction Factor (for 1- & 3-Phase Units) Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 kW Correction Factor (for 480V Units) Supply Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage, use voltage² / 480² kW Correction Factor (for 575V Units) Supply Voltage 560 550 540 Correction Factor 0.95 0.91 0.88 Multiply rated kW by correction factor to get actual kW. SS-CPC90-150 www.goodmanmfg.com 13 Product Specifications Heat Kit Electrical Data (Blower Only, Heat Mode) — 10 Tons Model and Heat Kit Usage MCA¹ at 208 / 240V MOP² (amps) at 208 / 240V Actual kW at 240V Recommended Airflow Range 49 48 / 55 87 / 100 121 / 139 60 50 / 60 90 / 100 125 / 150 15 30 43 3500 - 4500 CFM 3500 - 4500 CFM 4000 - 4500 CFM MCA¹ at 208 / 240V MOP² (amps) at 208 / 240V Actual kW at 240V Recommended Airflow Range 50 49 / 57 88 / 102 122 / 141 60 50 / 60 90 / 110 125 / 150 15 30 43 3500 - 4500 CFM 3500 - 4500 CFM 4000 - 4500 CFM MCA¹ at 480V MOP² (amps) at 480V Actual kW at 480V Recommended Airflow Range 24 27 50 70 30 30 50 70 15 30 43 3500 - 4500 CFM 3500 - 4500 CFM 4000 - 4500 CFM MCA¹ at 575V MOP² (amps) at 575V Actual kW at 575V Recommended Airflow Range 17 22 41 57 20 25 45 60 15 30 43 3500 - 4500 CFM 3500 - 4500 CFM 4000 - 4500 CFM CPC120XXX3BXXX EHK3-16 EHK3-30 EHK3-45 Model and Heat Kit Usage CPC120XXX3HXXX EHK3-16 EHK3-30 EHK3-45 Model and Heat Kit Usage CPC120XXX4BXXX EHK4-16 EHK4-30 EHK4-45 Model and Heat Kit Usage CPC0120XXX7BXXX EHK7-16 EHK7-30 EHK7-45 ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device kW Correction Factor kW Correction Factor (for 1- & 3-Phase Units) Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 kW Correction Factor for 480V Units Actual Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage use voltage² / 480² kW Correction Factor for 575V Units Minimum Airflow for Electric Heat Heater Size (kW) Min. CFM Down-shot Min. CFM Horizontal 15 4,000 4,000 Supply Voltage 560 550 540 30 4,000 4,000 Correction Factor 0.95 0.91 0.88 43 4,000 4,000 Multiply rated kW by correction factor to get actual kW 14www.goodmanmfg.com SS-CPC90-150 Product Specifications Heat Kit Electrical Data (Blower Only, Heat Mode) — 12½ Tons Model and Heat Kit Usage CPC150***3B*** MCA1 at 208 / 240V MOP2 (amps) at 208 / 240V 65 80 Actual kW at 240V Recommended Airflow Range EHK3-16 65 80 15 4000 - 5600 EHK3-30 102 110 30 4300 - 5600 EHK3-45 141 150 43 4500 - 5600 MCA1 at 208 / 240V MOP2 (amps) at 208 / 240V Actual kW at 240V Recommended Airflow Range CPC150***4B*** 31 40 EHK4-16 31 40 15 4000 - 5600 EHK4-30 51 60 30 4300 - 5600 EHK4-45 71 80 43 4500 - 5600 MCA1 at 208 / 240V MOP2 (amps) at 208 / 240V Actual kW at 240V Recommended Airflow Range CPC150***7B*** 23 30 EHK7-16 24 30 15 4000 - 5600 EHK7-30 43 45 30 4300 - 5600 EHK7-45 59 60 43 4500 - 5600 Model and Heat Kit Usage Model and Heat Kit Usage ¹ Minimum Circuit Ampacity (standard drive) ² Maximum Overcurrent Protection device (standard drive) KW Correction Factors kW Correction Factor (for 1- & 3-Phase Units) Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 kW Correction Factor (for 480V Units) Supply Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage, use voltage² / 480² kW Correction Factor (for 575V Units) Supply Voltage 560 550 540 Correction Factor 0.95 0.91 0.88 Multiply rated kW by correction factor to get actual kW. SS-CPC90-150 www.goodmanmfg.com 15 89.7 0.83 20 6.24 20.5 236 109 87.1 0.79 21 6.19 20.4 234 108 80.4 0.77 24 6.06 20.0 227 105 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 2400 3000 3375 59 88.2 0.73 18 6.19 20.4 234 108 85.6 0.70 18 6.15 20.3 231 107 79.0 0.67 20 6.01 19.9 224 104 Airflow MBh S/T ∆T kW 3375 Amps Hi PR Lo PR MBh S/T ∆T kW 3000 Amps Hi PR Lo PR MBh S/T ∆T 2400 kW Amps Hi PR Lo PR 71 - 92.3 100.0 107.3 0.75 0.56 0.36 19 15 11 6.36 6.55 6.75 20.9 21.4 22.0 254 268 280 116 127 135 89.7 97.0 104.1 0.71 0.54 0.35 20 16 11 6.32 6.50 6.70 20.8 21.2 21.8 252 266 277 115 126 134 82.7 89.6 96.1 0.69 0.52 0.33 22 18 12 6.18 6.36 6.55 20.3 20.8 21.4 244 258 269 112 122 130 63 67 91.4 100.2 0.61 0.42 15 12 6.32 6.50 20.8 21.2 252 266 115 126 88.7 97.2 0.58 0.40 16 12 6.27 6.45 20.6 21.1 249 263 114 124 81.9 89.7 0.56 0.39 18 13 6.13 6.31 20.2 20.7 242 255 111 121 87.6 0.86 21 6.69 21.7 265 116 85.1 0.82 21 6.64 21.6 262 114 78.5 0.79 24 6.49 21.2 254 111 59 86.1 0.76 18 6.64 21.6 262 114 83.6 0.72 19 6.59 21.4 260 113 77.2 0.70 21 6.44 21.0 252 110 90.2 0.77 19 6.82 22.1 285 123 87.6 0.74 20 6.77 22.0 282 122 80.8 0.71 22 6.62 21.5 274 118 63 89.3 0.63 15 6.77 22.0 282 122 86.7 0.61 16 6.72 21.8 279 120 80.0 0.58 18 6.57 21.4 271 117 67 97.8 0.44 12 6.98 22.5 298 133 95.0 0.42 12 6.92 22.4 295 132 87.7 0.40 14 6.76 21.9 286 128 71 - 59 84.1 0.78 18 7.03 23.0 298 119 81.6 0.74 19 6.98 22.8 295 118 75.4 0.72 21 6.81 22.3 286 114 97.6 104.8 85.5 0.58 0.38 0.89 16 11 21 7.03 7.25 7.08 22.7 23.3 23.1 301 314 301 134 143 120 94.8 101.7 83.0 0.56 0.36 0.84 16 11 21 6.98 7.19 7.03 22.5 23.1 23.0 298 311 298 133 141 119 87.5 93.9 76.6 0.54 0.35 0.81 18 12 24 6.82 7.02 6.87 22.0 22.7 22.5 289 302 289 129 137 115 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 88.0 0.79 19 7.23 23.5 324 128 85.5 0.76 20 7.17 23.4 321 126 78.9 0.73 22 7.01 22.9 311 123 85.9 0.82 19 7.59 24.8 369 134 83.4 0.78 20.0 7.53 24.6 366 133 77.0 0.75 22 7.35 24.1 355 129 93.0 0.62 16 7.83 25.4 390 146 90.3 0.59 16 7.76 25.2 386 145 83.3 0.57 18 7.58 24.7 375 141 99.8 0.40 11 8.07 26.2 407 156 96.9 0.38 11 8.01 26.0 403 154 89.4 0.37 13 7.82 25.4 391 150 79.3 0.95 20 7.73 25.5 386 132 77.0 0.90 21 7.67 25.3 382 131 71.0 0.87 24 7.49 24.8 371 127 59 77.9 0.83 18 7.67 25.3 382 131 75.7 0.80 18 7.61 25.1 378 130 69.8 0.77 21 7.43 24.6 367 126 Shaded area reflects ACCA (TVA) conditions 95.3 102.3 83.4 0.60 0.39 0.91 16 11 21 7.45 7.69 7.43 24.1 24.8 24.3 342 357 343 139 149 126 92.5 99.3 81.0 0.57 0.37 0.87 16 11 22 7.39 7.63 7.38 24.0 24.7 24.1 339 354 340 138 147 125 85.4 91.7 74.8 0.55 0.35 0.84 18 12 24 7.22 7.45 7.20 23.5 24.1 23.6 329 343 330 134 143 121 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 87.2 95.5 82.0 85.0 93.2 0.65 0.45 0.80 0.67 0.47 15 12 18 16 12 7.17 7.39 7.37 7.53 7.76 23.4 24.0 24.1 24.6 25.2 321 339 340 366 386 126 138 125 133 145 84.6 92.7 79.7 82.6 90.5 0.62 0.43 0.77 0.64 0.44 16 12 19 16 12 7.12 7.34 7.32 7.47 7.70 23.2 23.8 24.0 24.4 25.0 318 336 336 362 382 125 137 124 132 144 78.1 85.6 73.5 76.2 83.5 0.60 0.41 0.74 0.62 0.43 18 14 21 18 14 6.95 7.16 7.15 7.29 7.52 22.7 23.3 23.5 23.9 24.5 308 326 326 351 371 121 133 120 128 139 81.6 0.85 19 7.89 26.0 415 141 79.2 0.81 20 7.83 25.8 411 139 73.1 0.78 22 7.65 25.3 399 135 63 80.8 0.70 15 7.83 25.8 411 139 78.4 0.66 16 7.77 25.6 407 138 72.4 0.64 18 7.58 25.1 395 134 88.3 0.64 15 8.14 26.7 439 154 85.8 0.61 16 8.08 26.5 434 152 79.2 0.59 18 7.88 25.9 421 147 67 88.5 0.48 12 8.08 26.5 434 152 85.9 0.46 12 8.01 26.3 430 150 79.3 0.44 13 7.82 25.7 417 146 105 73.4 0.96 19 7.99 26.7 427 137 71.3 0.91 20 7.92 26.5 422 135 65.8 0.88 22 7.73 25.9 410 131 59 72.2 0.84 17 7.92 26.5 422 135 70.1 0.80 17 7.86 26.3 418 134 64.7 0.77 19 7.67 25.7 406 130 75.6 0.86 18 8.16 27.2 459 145 73.4 0.82 18 8.09 27.0 454 144 67.7 0.79 20 7.90 26.4 441 140 63 74.8 0.70 14 8.09 27.0 454 144 72.6 0.67 15 8.03 26.8 450 143 67.1 0.65 17 7.83 26.2 436 138 81.8 0.65 14 8.42 27.9 485 159 79.4 0.62 15 8.35 27.7 480 157 73.3 0.60 17 8.15 27.1 466 153 67 82.0 0.49 11 8.35 27.7 480 157 79.6 0.46 11 8.28 27.5 475 156 73.5 0.45 13 8.08 26.9 461 151 87.8 0.42 10 8.69 28.8 506 169 85.3 0.40 10 8.62 28.6 501 167 78.7 0.38 12 8.41 27.9 486 162 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 94.8 0.41 11 8.40 27.5 458 163 92.0 0.39 11 8.34 27.3 453 162 85.0 0.38 12 8.13 26.7 439 157 71 - 115 Product Specifications Expanded Cooling Data — 7½ Tons (A Models) 16www.goodmanmfg.com SS-CPC90-150 SS-CPC90-150 www.goodmanmfg.com 92.9 0.96 24 6.33 20.8 241 112 90.2 0.91 25 6.29 20.7 238 110 83.2 0.88 28 6.15 20.3 231 107 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 2400 3000 3375 59 91.3 0.91 23 6.29 20.7 238 110 88.6 0.87 24 6.24 20.5 236 109 81.8 0.84 26 6.10 20.1 229 106 Airflow MBh S/T ∆T kW 3375 Amps Hi PR Lo PR MBh S/T ∆T kW 3000 Amps Hi PR Lo PR MBh S/T ∆T 2400 kW Amps Hi PR Lo PR 94.7 0.92 24 6.46 21.2 259 119 91.9 0.88 25 6.41 21.0 257 118 84.8 0.85 28 6.27 20.6 249 114 63 93.3 0.86 22 6.41 21.0 257 118 90.6 0.82 23 6.36 20.9 254 116 83.6 0.79 25 6.22 20.5 246 113 99.2 105.8 90.7 0.83 0.68 0.99 23 20 25 6.65 6.85 6.79 21.7 22.3 22.0 274 285 270 130 138 118 96.3 102.7 88.1 0.80 0.65 0.95 23 20 26 6.60 6.80 6.74 21.5 22.1 21.9 271 283 268 128 137 117 88.9 94.8 81.3 0.77 0.62 0.91 26 23 28 6.45 6.65 6.59 21.1 21.7 21.4 263 274 260 124 133 113 67 71 59 99.7 106.5 89.2 0.70 0.52 0.95 19 15 23 6.60 6.80 6.74 21.5 22.1 21.9 271 283 268 128 137 117 96.8 103.4 86.6 0.67 0.50 0.90 20 16 24 6.55 6.75 6.69 21.4 22.0 21.7 268 280 265 127 135 116 89.3 95.5 79.9 0.64 0.48 0.87 22 18 27 6.40 6.60 6.54 21.0 21.5 21.3 260 271 257 123 131 112 92.5 0.96 24 6.93 22.4 291 125 89.8 0.91 25 6.88 22.3 288 124 82.9 0.88 28 6.72 21.8 279 120 63 91.1 0.89 22 6.88 22.3 288 124 88.5 0.85 23 6.82 22.1 285 123 81.6 0.82 26 6.67 21.7 277 119 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65 96.8 103.3 88.6 0.86 0.70 1.00 23 20 24 7.14 7.36 7.19 23.0 23.6 23.4 307 320 307 137 146 122 94.0 100.3 86.0 0.82 0.67 0.97 24 21 26 7.08 7.30 7.14 22.8 23.5 23.3 304 317 304 136 144 121 86.8 92.6 79.4 0.80 0.65 0.94 26 23 28 6.92 7.13 6.97 22.3 23.0 22.8 295 308 295 131 140 118 67 71 59 97.3 104.1 87.0 0.72 0.54 1.00 19 15 24 7.08 7.30 7.14 22.8 23.5 23.3 304 317 304 136 144 121 94.5 101.0 84.5 0.69 0.52 0.93 20 16 24 7.03 7.25 7.08 22.7 23.3 23.1 301 314 301 134 143 120 87.2 93.2 78.0 0.67 0.50 0.89 22 18 27 6.87 7.08 6.92 22.2 22.8 22.6 292 305 292 130 139 116 90.3 0.98 24 7.34 23.9 331 130 87.6 0.94 25 7.29 23.7 328 129 80.9 0.90 28 7.12 23.2 318 125 88.1 1.00 24 7.71 25.1 377 137 85.5 0.97 25 7.65 24.9 373 136 78.9 0.93 28 7.47 24.4 362 131 92.2 0.92 23 7.95 25.8 398 149 89.6 0.87 24 7.89 25.6 394 148 82.7 0.84 27 7.70 25.0 382 144 98.4 0.74 20 8.20 26.5 415 159 95.5 0.71 21 8.14 26.3 411 158 88.2 0.68 23 7.94 25.8 399 153 71 99.1 0.57 15 8.14 26.3 411 158 96.2 0.55 16 8.07 26.2 407 156 88.8 0.53 18 7.88 25.6 395 151 82.1 1.00 22 7.85 25.9 394 135 79.7 1.00 24 7.79 25.7 390 134 73.6 1.00 28 7.61 25.1 378 130 59 80.7 1.00 22 7.79 25.7 390 134 78.3 0.99 24 7.73 25.5 386 132 72.3 0.96 27 7.55 25.0 375 128 Shaded area reflects AHRI (TVA) conditions 94.5 100.9 86.4 0.89 0.72 1.00 23 20 24 7.57 7.81 7.55 24.5 25.2 24.7 349 364 350 142 152 129 91.8 97.9 83.9 0.85 0.69 1.00 24 21 26 7.51 7.75 7.49 24.3 25.0 24.5 346 361 347 141 150 127 84.7 90.4 77.4 0.82 0.66 0.97 26 23 29 7.33 7.56 7.32 23.8 24.5 24.0 335 350 336 137 146 124 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 88.9 95.0 101.6 84.9 86.8 92.7 0.91 0.74 0.55 1.00 0.94 0.77 22 19 15 23 22 19 7.29 7.51 7.75 7.49 7.65 7.89 23.7 24.3 25.0 24.5 24.9 25.6 328 346 361 347 373 394 129 141 150 127 136 148 86.3 92.3 98.6 82.4 84.2 90.0 0.87 0.71 0.53 0.96 0.90 0.73 23 20 16 24 23 20.0 7.23 7.45 7.69 7.43 7.59 7.83 23.5 24.1 24.8 24.3 24.8 25.4 324 342 357 343 369 390 128 139 149 126 134 147 79.7 85.1 91.0 76.1 77.8 83.1 0.84 0.68 0.51 0.92 0.86 0.70 26 22 18 27 26 22 7.06 7.28 7.50 7.26 7.41 7.64 23.1 23.6 24.3 23.8 24.2 24.9 315 332 346 333 358 378 124 135 144 122 130 142 83.7 1.00 23 8.02 26.4 424 143 81.2 1.00 25 7.96 26.2 420 142 75.0 0.97 28 7.77 25.6 407 138 63 82.4 1.00 22 7.96 26.2 420 142 80.0 0.93 23 7.89 26.0 415 141 73.9 0.90 25 7.71 25.4 403 136 87.6 0.95 23 8.27 27.1 448 157 85.1 0.91 24 8.21 26.9 443 155 78.5 0.87 26 8.01 26.3 430 150 67 88.1 0.79 19 8.21 26.9 443 155 85.5 0.76 20 8.14 26.7 439 154 78.9 0.73 22 7.95 26.1 426 149 105 76.0 1.00 21 8.12 27.1 435 139 73.8 1.00 23 8.05 26.9 431 138 68.1 1.00 26 7.86 26.3 418 134 59 74.7 1.00 20 8.05 26.9 431 138 72.5 1.00 22 7.99 26.7 427 137 67.0 0.97 25 7.80 26.1 414 133 77.5 1.00 21 8.29 27.6 468 148 75.2 1.00 23 8.22 27.4 464 147 69.4 0.98 26 8.02 26.8 450 143 63 76.4 1.00 21 8.22 27.4 464 147 74.1 0.94 21 8.16 27.2 459 145 68.4 0.91 24 7.96 26.6 445 141 71 87.2 0.60 14 8.76 29.0 511 171 84.7 0.57 15 8.69 28.8 506 169 78.1 0.55 16 8.48 28.1 490 164 81.2 86.6 0.96 0.78 21 18 8.55 8.83 28.4 29.2 495 516 162 173 78.8 84.1 0.91 0.74 22 19 8.48 8.76 28.1 29.0 490 511 160 171 72.7 77.6 0.88 0.71 25 21 8.28 8.55 27.5 28.4 475 495 156 166 67 81.6 0.80 18 8.48 28.1 490 160 79.2 0.76 19 8.42 27.9 485 159 73.1 0.74 21 8.21 27.3 470 154 kW = Total system power Amps = outdoor unit amps (comp.+fan) 93.5 0.77 20 8.54 27.9 467 167 90.8 0.74 20 8.47 27.7 462 165 83.8 0.71 23 8.27 27.1 448 160 71 94.1 0.59 15 8.47 27.7 462 165 91.4 0.57 16 8.40 27.5 458 164 84.4 0.55 18 8.20 26.9 444 159 115 Product Specifications Expanded Cooling Data — 7½ Tons (A Models cont.) 17 87.7 0.82 20 6.31 21.2 236 104 85.1 0.78 20 6.27 21.1 234 103 78.6 0.76 23 6.14 20.7 227 100 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 2400 3000 3375 59 86.2 0.72 17 6.27 21.1 234 103 83.7 0.69 18 6.23 21.0 231 102 77.3 0.67 20 6.10 20.6 224 99 Airflow MBh S/T ∆T kW 3375 Amps Hi PR Lo PR MBh S/T ∆T kW 3000 Amps Hi PR Lo PR MBh S/T ∆T 2400 kW Amps Hi PR Lo PR 90.3 0.74 18 6.43 21.6 254 111 87.7 0.70 19 6.39 21.4 252 110 80.9 0.68 21 6.25 21.1 244 107 63 89.4 0.60 15 6.39 21.4 252 110 86.8 0.58 15 6.34 21.3 249 109 80.1 0.56 17 6.21 20.9 242 106 71 - 59 84.2 0.75 17 6.69 22.2 262 109 81.8 0.71 18 6.65 22.1 260 108 75.5 0.69 20 6.50 21.7 252 105 97.7 104.9 85.7 0.56 0.36 0.85 15 10 20 6.61 6.80 6.74 22.1 22.6 22.4 268 280 265 121 129 110 94.9 101.8 83.2 0.53 0.34 0.81 15 11 21 6.57 6.75 6.69 21.9 22.5 22.2 266 277 262 120 128 109 87.6 94.0 76.8 0.51 0.33 0.78 17 12 23 6.42 6.61 6.55 21.5 22.1 21.8 258 269 254 117 124 106 67 97.9 0.42 11 6.56 21.9 266 120 95.1 0.40 12 6.52 21.8 263 119 87.8 0.38 13 6.38 21.4 255 115 88.2 0.76 18 6.87 22.8 285 117 85.6 0.73 19 6.82 22.6 282 116 79.0 0.70 21 6.68 22.2 274 113 63 87.3 0.63 15 6.82 22.6 282 116 84.8 0.60 16 6.77 22.5 279 115 78.2 0.58 17 6.63 22.1 271 112 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 71 - 59 82.2 0.77 17 7.07 23.6 298 114 79.8 0.73 18 7.02 23.4 295 112 73.7 0.71 20 6.86 23.0 286 109 95.5 102.5 83.6 0.58 0.37 0.87 15 10 20 7.07 7.28 7.12 23.3 23.9 23.7 301 314 301 128 137 115 92.7 99.5 81.2 0.55 0.35 0.83 16 11 21 7.02 7.22 7.07 23.1 23.7 23.6 298 311 298 127 135 114 85.5 91.8 74.9 0.53 0.34 0.80 17 12 23 6.86 7.06 6.91 22.7 23.3 23.1 289 302 289 123 131 110 67 95.6 0.43 11 7.02 23.1 298 127 92.9 0.41 12 6.97 23.0 295 126 85.7 0.40 13 6.81 22.5 286 122 86.1 0.78 18 7.26 24.1 324 122 83.6 0.75 19 7.21 24.0 321 121 77.1 0.72 21 7.05 23.5 311 117 84.0 0.81 18 7.60 25.3 369 128 81.5 0.77 19 7.55 25.1 366 127 75.3 0.74 21 7.38 24.6 355 123 90.9 0.61 15 7.83 25.9 390 140 88.3 0.58 16 7.77 25.7 386 139 81.5 0.56 18 7.59 25.2 375 134 97.6 0.39 10 8.07 26.6 407 149 94.7 0.37 11 8.01 26.4 403 148 87.4 0.36 12 7.82 25.9 391 143 77.5 0.94 20 7.74 26.0 386 126 75.2 0.89 21 7.68 25.8 382 125 69.4 0.86 23 7.51 25.3 371 121 59 76.2 0.82 17 7.68 25.8 382 125 74.0 0.79 18 7.62 25.7 378 124 68.3 0.76 20 7.45 25.1 367 120 Shaded area reflects ACCA (TVA) conditions 93.2 100.0 81.6 0.59 0.38 0.90 15 10 20 7.47 7.70 7.46 24.7 25.3 24.9 342 357 343 133 142 121 90.5 97.1 79.2 0.56 0.36 0.86 16 11 21 7.42 7.64 7.40 24.5 25.2 24.7 339 354 340 132 141 119 83.5 89.6 73.1 0.54 0.35 0.83 17 12 23 7.25 7.47 7.23 24.0 24.7 24.2 329 343 330 128 136 116 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 85.2 93.4 80.2 83.1 91.1 0.64 0.44 0.79 0.66 0.46 15 11 17 15 11 7.21 7.42 7.40 7.55 7.77 24.0 24.5 24.7 25.1 25.7 321 339 340 366 386 121 132 119 127 139 82.7 90.7 77.9 80.7 88.4 0.61 0.42 0.76 0.63 0.44 16 12 18 16 12 7.15 7.36 7.34 7.49 7.71 23.8 24.4 24.5 25.0 25.6 318 336 336 362 382 120 131 118 126 137 76.4 83.7 71.9 74.5 81.6 0.59 0.41 0.73 0.61 0.42 17 13 20 17 13 7.00 7.20 7.18 7.32 7.54 23.3 23.9 24.0 24.5 25.0 308 326 326 351 371 116 127 115 122 133 79.8 0.84 18 7.90 26.5 415 134 77.5 0.80 19 7.84 26.3 411 133 71.5 0.77 21 7.66 25.8 399 129 63 79.0 0.69 15 7.83 26.3 411 133 76.7 0.66 15 7.78 26.1 407 132 70.8 0.63 17 7.60 25.6 395 128 86.4 0.63 15 8.13 27.1 439 147 83.9 0.60 16 8.07 26.9 434 145 77.4 0.58 17 7.89 26.4 421 141 67 86.5 0.48 11 8.07 26.9 434 145 84.0 0.45 12 8.01 26.7 430 144 77.5 0.44 13 7.82 26.2 417 139 105 71.8 0.94 18 7.98 27.1 427 131 69.7 0.90 19 7.92 26.9 422 129 64.3 0.87 21 7.74 26.4 410 125 59 70.6 0.83 16 7.92 26.9 422 129 68.5 0.79 17 7.86 26.8 418 128 63.3 0.76 19 7.68 26.2 406 124 73.9 0.84 17 8.15 27.6 459 139 71.8 0.81 18 8.08 27.4 454 138 66.2 0.78 20 7.90 26.9 441 133 63 73.2 0.69 14 8.08 27.4 454 138 71.0 0.66 14 8.02 27.2 450 136 65.6 0.64 16 7.84 26.7 436 132 80.0 0.64 14 8.39 28.3 485 152 77.7 0.61 15 8.33 28.1 480 150 71.7 0.59 16 8.14 27.5 466 146 67 80.2 0.48 10 8.33 28.1 480 150 77.8 0.46 11 8.26 27.9 475 149 71.8 0.44 12 8.07 27.3 461 144 85.9 0.41 10 8.65 29.1 506 162 83.4 0.39 10 8.59 28.9 501 160 76.9 0.38 11 8.39 28.3 486 155 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 92.7 0.41 10 8.38 27.9 458 156 90.0 0.39 11 8.32 27.7 453 155 83.1 0.37 12 8.12 27.1 439 150 71 - 115 Product Specifications Expanded Cooling Data — 7½ Tons (B Models) 18www.goodmanmfg.com SS-CPC90-150 SS-CPC90-150 www.goodmanmfg.com 90.8 0.95 23 6.40 21.5 241 107 88.2 0.90 24 6.36 21.4 238 106 81.4 0.87 27 6.22 21.0 231 102 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 2400 3000 3375 59 89.3 0.90 22 6.36 21.4 238 106 86.7 0.86 23 6.31 21.2 236 105 80.0 0.83 25 6.18 20.9 229 101 Airflow MBh S/T ∆T kW 3375 Amps Hi PR Lo PR MBh S/T ∆T kW 3000 Amps Hi PR Lo PR MBh S/T ∆T 2400 kW Amps Hi PR Lo PR 92.6 0.91 23 6.52 21.8 259 113 89.9 0.87 24 6.48 21.7 257 112 83.0 0.84 27 6.34 21.3 249 109 63 91.2 0.85 21 6.48 21.7 257 112 88.5 0.81 22 6.43 21.6 254 111 81.7 0.78 24 6.30 21.2 246 108 97.0 103.4 88.7 0.82 0.67 0.98 22 19 24 6.71 6.90 6.84 22.3 22.9 22.7 274 285 270 124 132 113 94.1 100.4 86.1 0.79 0.64 0.93 23 20 25 6.66 6.85 6.79 22.2 22.8 22.5 271 283 268 123 131 112 86.9 92.7 79.5 0.76 0.61 0.90 25 22 27 6.52 6.70 6.64 21.8 22.3 22.1 263 274 260 119 127 108 67 71 59 97.4 104.2 87.2 0.69 0.51 0.93 18 15 22 6.66 6.85 6.79 22.2 22.8 22.5 271 283 268 123 131 112 94.6 101.1 84.6 0.66 0.49 0.89 19 15 23 6.61 6.80 6.74 22.1 22.6 22.4 268 280 265 121 129 110 87.3 93.3 78.1 0.63 0.47 0.86 21 17 26 6.47 6.65 6.60 21.6 22.2 22.0 260 271 257 118 125 107 90.4 0.95 23 6.97 23.0 291 120 87.8 0.90 24 6.92 22.9 288 119 81.0 0.87 27 6.77 22.5 279 115 63 89.1 0.88 21 6.92 22.9 288 119 86.5 0.84 22 6.87 22.8 285 117 79.8 0.81 25 6.72 22.3 277 114 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65 94.7 101.0 86.6 0.85 0.69 1.00 22 19 24 7.17 7.39 7.23 23.6 24.2 24.0 307 320 307 131 139 117 91.9 98.1 84.1 0.81 0.66 0.96 23 20 25 7.12 7.33 7.17 23.4 24.0 23.9 304 317 304 130 138 116 84.9 90.5 77.6 0.78 0.64 0.92 25 22 27 6.96 7.17 7.02 23.0 23.6 23.4 295 308 295 126 134 112 67 71 59 95.2 101.7 85.1 0.71 0.53 0.96 18 15 22 7.12 7.33 7.17 23.4 24.0 23.9 304 317 304 130 138 116 92.4 98.8 82.6 0.68 0.51 0.91 19 15 23 7.07 7.28 7.12 23.3 23.9 23.7 301 314 301 128 137 115 85.3 91.2 76.3 0.66 0.49 0.88 21 17 26 6.91 7.12 6.96 22.8 23.4 23.3 292 305 292 124 132 111 88.3 0.97 23 7.37 24.4 331 125 85.7 0.92 24 7.32 24.3 328 123 79.1 0.89 27 7.15 23.8 318 120 92.4 0.87 22 7.59 25.0 349 136 89.7 0.83 23 7.53 24.8 346 135 82.8 0.80 26 7.36 24.4 335 131 84.5 1.00 23 7.57 25.2 350 123 82.0 0.99 25 7.51 25.0 347 122 75.7 0.95 28 7.34 24.5 336 118 86.1 1.00 23 7.72 25.6 377 131 83.6 0.95 24 7.66 25.5 373 130 77.2 0.92 27 7.49 25.0 362 126 90.2 0.90 22 7.95 26.2 398 143 87.6 0.86 23 7.89 26.1 394 141 80.8 0.83 26 7.71 25.5 382 137 96.2 0.73 19 8.19 27.0 415 152 93.4 0.70 20 8.13 26.8 411 151 86.2 0.67 22 7.94 26.2 399 146 71 96.9 0.56 15 8.13 26.8 411 151 94.1 0.54 16 8.07 26.6 407 149 86.8 0.52 17 7.88 26.1 395 145 80.3 1.00 22 7.86 26.4 394 129 77.9 1.00 24 7.80 26.2 390 128 71.9 0.99 27 7.62 25.6 378 124 59 78.9 1.00 21 7.80 26.2 390 128 76.6 0.98 23 7.74 26.0 386 126 70.7 0.94 26 7.56 25.5 375 123 Shaded area reflects AHRI (TVA) conditions 98.6 0.71 19 7.81 25.7 364 145 95.7 0.68 20 7.76 25.5 361 143 88.4 0.65 22 7.58 25.0 350 139 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 87.0 92.9 99.3 83.0 84.8 90.6 0.90 0.73 0.55 1.00 0.93 0.75 21 19 15 23 21 19 7.32 7.53 7.76 7.51 7.66 7.89 24.3 24.8 25.5 25.0 25.5 26.1 328 346 361 347 373 394 123 135 143 122 130 141 84.4 90.2 96.4 80.6 82.4 88.0 0.86 0.70 0.52 0.94 0.88 0.72 22 19 15 23 22 19 7.26 7.47 7.70 7.46 7.60 7.83 24.1 24.7 25.3 24.9 25.3 25.9 324 342 357 343 369 390 122 133 142 121 128 140 77.9 83.3 89.0 74.4 76.0 81.2 0.83 0.67 0.50 0.91 0.85 0.69 25 21 17 26 25 22 7.10 7.31 7.52 7.29 7.43 7.65 23.6 24.2 24.8 24.4 24.8 25.4 315 332 346 333 358 378 118 129 138 117 124 136 81.8 1.00 22 8.02 26.8 424 137 79.4 0.99 24 7.96 26.6 420 136 73.3 0.95 27 7.77 26.1 407 132 63 80.6 0.96 21 7.96 26.6 420 136 78.2 0.92 22 7.90 26.5 415 134 72.2 0.89 24 7.72 25.9 403 130 85.7 0.94 22 8.26 27.5 448 150 83.2 0.89 23 8.20 27.3 443 148 76.8 0.86 25 8.01 26.7 430 144 67 86.1 0.78 18 8.20 27.3 443 148 83.6 0.75 19 8.13 27.1 439 147 77.2 0.72 21 7.95 26.6 426 142 105 74.3 1.00 20 8.11 27.5 435 133 72.2 1.00 22 8.05 27.3 431 132 66.6 1.00 25 7.86 26.8 418 128 59 73.1 1.00 20 8.05 27.3 431 132 70.9 0.99 21 7.98 27.1 427 131 65.5 0.95 24 7.80 26.6 414 127 75.8 1.00 21 8.27 28.0 468 142 73.6 1.00 23 8.21 27.8 464 140 67.9 0.96 25 8.02 27.2 450 136 63 74.7 0.97 20 8.21 27.8 464 140 72.5 0.93 21 8.15 27.6 459 139 66.9 0.89 23 7.96 27.1 445 135 71 85.3 0.59 14 8.72 29.3 511 163 82.8 0.56 14 8.65 29.1 506 162 76.4 0.54 16 8.45 28.5 490 157 79.4 84.7 0.94 0.77 20 18 8.53 8.79 28.7 29.5 495 516 155 165 77.1 82.2 0.90 0.73 21 18 8.46 8.72 28.5 29.3 490 511 153 163 71.1 75.9 0.87 0.71 24 20 8.26 8.52 27.9 28.7 475 495 149 158 67 79.8 0.79 17 8.46 28.5 490 153 77.4 0.75 18 8.39 28.3 485 152 71.5 0.73 20 8.20 27.7 470 147 kW = Total system power Amps = outdoor unit amps (comp.+fan) 91.4 0.76 19 8.51 28.3 467 159 88.7 0.73 20 8.45 28.1 462 158 81.9 0.70 22 8.25 27.5 448 153 71 92.0 0.59 15 8.45 28.1 462 158 89.4 0.56 15 8.38 27.9 458 156 82.5 0.54 17 8.19 27.3 444 152 115 Product Specifications Expanded Cooling Data — 7½ Tons (B Models cont.) 19 89.6 0.64 19 8.90 235 99 MBh S/T ∆T kW HI PR LO PR MBh 101.6 104.7 S/T 0.79 0.71 ∆T 20 19 kW 8.90 8.90 HI PR 247 266 LO PR 105 111 3200 2800 3600 91.1 0.73 22 8.90 237 101 MBh S/T ∆T kW HI PR LO PR 3200 2800 87.5 0.66 19 8.90 264 105 94.8 0.69 19 8.90 272 108 90.7 0.55 16 8.90 284 112 99.3 0.38 12 8.90 299 122 98.2 107.6 0.57 0.40 16 12 8.90 8.90 292 309 115 126 59 63 67 97.6 101.2 110.9 0.72 0.60 0.42 18 16 12 8.90 8.90 8.90 274 295 312 109 116 127 89.0 0.75 22 8.90 266 106 118.0 96.4 0.33 0.78 11 22 8.90 8.90 290 274 128 109 85.4 0.68 19 8.90 300 109 92.5 0.70 19 8.90 309 113 59 95.3 0.74 18 8.90 312 114 118.8 96.9 0.36 0.84 11 21 8.90 8.90 329 315 137 115 - - 71 - 91.6 0.67 20 8.90 286 113 99.1 106.4 86.8 0.51 0.33 0.77 17 11 22 8.90 8.90 8.90 303 316 303 123 131 110 99.2 107.4 115.3 94.1 0.70 0.53 0.34 0.80 20 16 11 22 8.90 8.90 8.90 8.90 295 312 325 312 116 127 135 114 121.6 99.3 102.2 110.6 0.34 0.82 0.73 0.55 11 21 19 16 8.90 8.90 8.90 8.90 293 277 298 315 129 111 118 128 - - 71 - 93.8 101.5 108.9 0.65 0.49 0.32 20 16 11 8.90 8.90 8.90 255 270 281 107 117 124 98.7 101.6 110.0 0.75 0.67 0.51 21 20 16 8.90 8.90 8.90 245 263 278 104 110 120 MBh S/T ∆T kW HI PR LO PR 113.3 0.53 15 8.90 281 122 92.8 101.7 0.53 0.37 16 12 8.90 8.90 253 267 106 116 97.0 100.6 110.2 0.66 0.55 0.38 18 16 12 8.90 8.90 8.90 242 261 275 103 109 119 67 113.5 0.40 12 8.90 278 120 MBh S/T ∆T kW HI PR LO PR Airflow 59 63 MBh 100.0 103.6 S/T 0.69 0.58 ∆T 18 15 3600 kW 8.90 8.90 HI PR 245 263 LO PR 104 110 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 97.0 0.39 12 8.90 341 127 - 83.3 0.70 19 8.90 341 115 90.3 0.73 19 8.90 352 118 89.4 0.69 20 8.90 326 117 94.6 0.41 13 8.90 388 133 - 79.2 0.73 19 8.90 384 120 85.8 0.75 19 8.90 396 124 87.2 0.71 20 8.90 371 123 94.4 101.3 80.5 0.54 0.35 0.83 17 12 22 8.90 8.90 8.90 392 409 388 135 143 121 94.5 102.3 109.8 87.2 0.74 0.56 0.36 0.86 20 16 11 21 8.90 8.90 8.90 8.90 383 404 421 400 127 139 148 125 97.4 105.4 113.1 89.8 0.77 0.59 0.38 0.90 19 16 11 21 8.90 8.90 8.90 8.90 386 408 426 404 128 140 149 126 86.4 0.58 17 8.90 367 122 93.6 102.5 0.61 0.42 16 12 8.90 8.90 379 400 126 137 59 88.3 0.79 18 8.90 400 125 Shaded area reflects ACCA (TVA) conditions 96.8 103.9 84.7 0.52 0.34 0.80 17 11 22 8.90 8.90 8.90 344 359 345 128 137 116 96.9 104.9 112.5 91.8 0.72 0.54 0.35 0.83 20 16 11 22 8.90 8.90 8.90 8.90 336 355 370 355 121 132 141 120 99.8 108.0 115.9 94.6 0.75 0.57 0.37 0.87 19 16 11 21 8.90 8.90 8.90 8.90 339 358 374 359 122 133 142 121 88.5 0.57 16 8.90 323 116 95.9 105.1 0.59 0.41 16 12 8.90 8.90 332 351 120 131 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 98.8 108.2 93.0 96.4 105.6 0.62 0.43 0.76 0.64 0.44 16 12 18 16 12 8.90 8.90 8.90 8.90 8.90 336 355 355 382 404 121 132 119 127 139 - 89.9 0.42 12 8.90 436 140 97.4 0.44 12 8.90 450 144 - - 71 - 73.3 0.73 18 8.90 424 124 79.4 0.76 17 8.90 437 128 59 81.8 0.80 17 8.90 442 130 82.9 0.74 20 8.90 417 129 89.8 0.77 20 8.90 430 133 89.7 0.56 16 8.90 441 141 74.6 0.83 20 8.90 429 126 76.8 0.74 19 8.90 461 134 83.2 0.77 18 8.90 476 138 85.7 0.81 18 8.90 480 139 76.0 0.61 15 8.90 457 132 82.3 0.63 15 8.90 471 136 63 84.8 0.67 14 8.90 475 138 83.1 0.56 15 8.90 487 146 90.0 0.58 15 8.90 502 150 92.7 0.61 15 8.90 507 152 83.3 0.42 12 8.90 482 144 90.2 0.44 11 8.90 497 149 67 92.9 0.46 11 8.90 502 150 115 89.2 0.36 11 8.90 508 155 96.6 0.38 10 8.90 524 160 99.5 0.39 10 8.90 529 162 - - 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 96.3 0.36 11 8.90 460 150 97.2 104.3 80.8 0.58 0.37 0.86 16 11 20 8.90 8.90 8.90 454 474 442 145 155 130 92.5 100.1 107.4 83.2 0.80 0.61 0.39 0.91 19 16 11 19 8.90 8.90 8.90 8.90 435 459 479 446 135 147 156 131 82.0 0.61 16 8.90 413 128 88.9 0.63 16 8.90 426 132 63 67 91.6 100.3 0.66 0.46 15 12 8.90 8.90 430 454 133 145 105 Product Specifications Expanded Cooling Data — 8½ Tons 20www.goodmanmfg.com SS-CPC90-150 SS-CPC90-150 www.goodmanmfg.com MBh S/T ∆T kW HI PR LO PR 3200 2800 90.5 0.82 25 8.90 269 107 92.5 0.77 23 8.90 289 114 92.1 0.86 26 8.90 272 108 93.9 0.83 26 8.90 292 115 114.5 95.8 0.49 0.88 16 24 8.90 8.90 329 315 137 115 71 59 117.9 98.6 0.51 0.92 15 23 8.90 8.90 332 318 138 116 109.8 0.82 23 8.90 321 131 90.3 0.79 24 8.90 329 119 98.4 104.9 89.9 0.75 0.61 0.89 24 21 26 8.90 8.90 8.90 309 322 309 126 134 113 113.7 97.4 0.63 0.92 21 26 8.90 8.90 332 318 138 116 114.3 97.9 0.68 0.99 20 25 8.90 8.90 381 366 145 123 91.7 0.86 26 8.90 332 120 94.1 100.6 81.9 0.67 0.50 0.91 21 16 24 8.90 8.90 8.90 396 413 392 136 145 123 89.4 0.88 26 8.90 379 126 93.7 0.80 25 8.90 400 137 99.9 0.65 21 8.90 417 146 83.4 0.95 26 8.90 396 124 96.9 101.5 108.3 90.3 0.92 0.83 0.67 0.98 25 24 21 26 8.90 8.90 8.90 8.90 390 412 430 408 130 142 151 128 99.8 104.5 111.5 93.0 0.96 0.87 0.70 1.00 24 23 20 24 8.90 8.90 8.90 8.90 394 416 434 412 131 143 152 129 88.1 0.82 24 8.90 375 125 95.5 102.0 109.0 88.8 0.85 0.69 0.52 0.94 23 20 16 24 8.90 8.90 8.90 8.90 386 408 426 404 128 140 149 127 Shaded area reflects AHRI (TVA) conditions 96.0 102.4 87.7 0.77 0.63 0.91 24 21 26 8.90 8.90 8.90 351 366 352 131 139 118 99.3 104.0 111.0 95.1 0.89 0.80 0.65 0.95 25 24 21 26 8.90 8.90 8.90 8.90 343 362 377 363 123 135 144 122 107.1 0.84 23 8.90 365 136 96.5 103.2 86.2 0.65 0.48 0.87 20 16 25 8.90 8.90 8.90 348 362 348 129 138 117 97.9 104.6 111.8 93.4 0.82 0.67 0.50 0.91 23 20 16 24 8.90 8.90 8.90 8.90 339 358 374 359 122 133 142 121 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 59 100.8 107.7 115.1 96.2 98.3 105.1 112.3 91.4 0.86 0.70 0.52 0.95 0.89 0.72 0.54 1.00 22 19 15 23 22 19 16 23 8.90 8.90 8.90 8.90 8.90 8.90 8.90 8.90 343 362 377 363 390 412 430 408 123 135 144 122 130 142 151 128 117.1 100.4 102.3 0.66 0.96 0.93 20 25 24 8.90 8.90 8.90 335 322 346 140 117 125 98.9 105.7 88.4 0.63 0.47 0.85 20 16 25 8.90 8.90 8.90 306 319 306 125 133 111 116.4 99.8 101.7 106.6 0.61 0.90 0.86 0.78 20 26 25 24 8.90 8.90 8.90 8.90 296 280 301 318 131 112 119 130 119.9 102.8 104.8 0.64 0.94 0.91 20 25 24 8.90 8.90 8.90 299 283 304 132 113 120 96.2 100.7 107.4 0.80 0.73 0.59 25 24 21 8.90 8.90 8.90 260 275 287 109 119 127 109.1 0.75 24 8.90 284 123 MBh 102.2 104.2 S/T 0.87 0.83 ∆T 25 25 kW 8.90 8.90 HI PR 250 269 LO PR 106 112 3600 94.3 0.83 26 8.90 242 103 112.4 0.79 23 8.90 286 124 MBh 105.3 107.3 S/T 0.91 0.88 ∆T 24 24 kW 8.90 8.90 HI PR 252 271 LO PR 107 114 2800 67 110.3 0.68 19 8.90 318 130 117.2 98.1 100.2 107.1 0.47 0.86 0.80 0.65 16 24 23 20 8.90 8.90 8.90 8.90 293 277 298 315 129 111 118 128 71 59 63 120.7 101.0 103.3 0.49 0.90 0.84 15 23 22 8.90 8.90 8.90 296 280 301 131 112 119 94.7 101.2 108.2 0.75 0.61 0.45 23 20 16 8.90 8.90 8.90 258 272 284 108 118 126 MBh S/T ∆T kW HI PR LO PR 92.7 0.80 24 8.90 240 102 109.7 0.63 20 8.90 281 122 MBh 100.4 102.6 S/T 0.83 0.77 ∆T 24 23 kW 8.90 8.90 HI PR 247 266 LO PR 105 111 3200 67 112.9 0.66 19 8.90 284 123 Airflow 59 63 MBh 103.5 105.7 S/T 0.87 0.81 ∆T 23 22 3600 kW 8.90 8.90 HI PR 250 269 LO PR 106 112 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65 85.0 0.92 26 8.90 426 132 92.1 0.95 25 8.90 439 136 94.8 1.00 24 8.90 443 137 83.7 0.85 23 8.90 422 131 90.7 0.88 23 8.90 435 135 63 93.4 0.92 22 8.90 439 136 95.6 0.52 16 8.90 464 152 75.9 0.91 23 8.90 433 127 89.0 0.83 24 8.90 450 144 77.2 0.96 24 8.90 437 128 78.7 0.92 24 8.90 471 136 85.3 0.96 23 8.90 485 141 87.8 1.00 22 8.90 490 142 77.5 0.86 22 8.90 466 135 84.0 0.89 21 8.90 480 139 63 86.5 0.93 21 8.90 485 141 82.4 0.83 23 8.90 497 149 89.3 0.86 22 8.90 512 153 92.0 0.91 21 8.90 517 155 82.8 0.70 19 8.90 492 147 89.8 0.72 19 8.90 507 152 67 92.5 0.76 18 8.90 512 153 115 87.9 0.68 20 8.90 518 159 95.3 0.70 19 8.90 534 163 98.1 0.74 18 8.90 540 165 88.6 0.52 15 8.90 513 157 96.0 0.54 15 8.90 529 162 71 98.8 0.57 14 8.90 534 163 kW = Total system power Amps = outdoor unit amps (comp.+fan) 94.9 0.67 21 8.90 469 153 96.4 102.9 83.7 0.86 0.70 0.99 24 21 24 8.90 8.90 8.90 464 484 451 148 158 132 99.3 105.9 86.2 0.90 0.73 1.00 23 20 22 8.90 8.90 8.90 468 488 455 150 160 133 89.4 0.69 20 8.90 445 143 96.9 103.6 82.2 0.72 0.54 0.95 20 16 22 8.90 8.90 8.90 459 479 446 147 156 131 67 71 59 99.8 106.7 84.7 0.75 0.56 1.00 19 15 22 8.90 8.90 8.90 464 484 451 148 158 132 105 Product Specifications Expanded Cooling Data — 8½ Tons (cont.) 21 3200 4000 4500 3200 4000 4500 67 15 105 103.6 107.4 117.7 0.68 MBh S/T 131 314 12 0.45 118 295 16 0.61 129 311 12 0.43 - 136 358 12 0.46 123 335 16 0.63 134 354 12 0.44 19 143 407 12 0.47 141 403 12 0.45 24 239 103 ∆T Hi Pr Lo Pr 110 257 22 0.69 120 272 18 0.53 128 284 12 0.34 109 268 24 0.81 116 289 22 0.72 120 127 305 18 0.55 131 135 318 12 0.35 139 328 11 113 305 24 0.83 117 315 21 121 329 22 0.74 124 339 20 132 347 18 0.56 136 358 16 119 348 24 0.85 123 358 22 0.88 127 374 22 0.76 131 386 20 0.79 138 395 18 0.58 143 407 16 0.60 147 412 13 0.37 152 425 11 0.38 125 391 24 0.88 129 403 21 0.92 130 Shaded area reflects ACCA (TVA) conditions 140 362 12 0.36 145 373 11 0.37 153 20 407 0.78 112 315 16 0.58 144 11 429 0.96 105.4 108.5 117.4 126.0 102.9 106.0 114.7 123.1 100.5 103.4 112.0 120.2 98.0 100.9 109.2 117.2 93.1 132 298 20 0.77 132 16 411 0.40 S/T 124 277 21 0.86 124 19 390 0.63 MBh 113 292 11 0.36 146 21 362 0.83 106 280 16 0.57 137 11 377 0.93 124 Lo Pr 265 19 0.75 126 16 361 0.39 - 21 0.84 118 19 342 0.61 137 387 247 0.35 140 21 318 0.80 125 - 20 0.78 91.6 127 399 18 0.81 ∆T 0.55 132 11 331 0.90 118 391 - - - 137 434 15 0.71 149 458 12 0.49 148 454 12 0.47 149 458 16 0.62 151 463 15 0.65 143 440 13 0.45 159 478 11 0.40 161 483 11 0.42 - - - - - - - - - - - - - - - 71 59 133 446 20 0.93 134 450 19 0.97 128 428 19 0.78 84.8 132 441 17 0.81 91.9 133 446 17 0.85 94.7 133 421 22 0.79 145 445 18 0.60 129 432 22 0.89 63 67 155 506 11 0.49 148 486 13 0.45 96.3 153 501 11 0.47 - - - - - - - - - - - - - - - 71 156 511 14 0.66 166 533 10 0.42 137 465 20 0.80 88.8 142 480 18 0.83 165 528 10 0.40 150 491 17 0.60 160 512 12 0.39 96.1 103.2 155 506 15 0.63 96.2 104.2 111.8 143 484 18 0.87 99.1 107.3 115.1 136 460 17 0.66 87.9 140 475 15 0.68 95.3 104.4 142 479 14 0.71 98.1 107.5 115 kW = Total system power Amps = outdoor unit amps (comp.+fan) 154 464 12 0.39 95.9 103.8 111.4 86.3 137 434 20 0.82 138 438 19 0.86 131 417 18 0.65 94.9 104.0 135 430 16 0.67 99.2 102.8 112.7 129 403 18 0.85 Hi Pr 0.72 121 16 318 0.38 - 370 14 0.43 - - - - 67 0.81 114 19 301 0.59 130 344 18 0.63 99.9 109.5 129 382 16 0.65 63 S/T 133 21 280 0.78 119 - 21 0.75 96.4 122 355 19 0.78 - - - - - 59 102.2 105.9 116.0 107 125 11 295 0.88 112 343 - - - 131 386 16 0.68 104.4 108.2 118.6 123 358 18 0.82 - 71 114.2 117.5 127.2 136.6 111.5 114.8 124.3 133.4 108.9 112.1 121.3 130.2 106.2 109.3 118.4 127.0 100.9 103.9 112.4 120.7 93.5 114 15 283 0.37 - 325 14 0.42 67 MBh 268 0.57 125 302 18 0.61 - - - - 63 Lo Pr 20 249 ∆T Hi Pr 0.76 115 - 21 0.73 98.8 102.4 112.2 116 312 19 0.75 - - - - - 59 107.6 111.5 122.1 0.84 108 302 - - 124 339 15 0.66 107.0 110.9 121.6 117 315 18 0.79 - 71 117.6 121.1 131.0 140.6 114.9 118.3 128.0 137.4 112.1 115.4 125.0 134.1 109.4 112.6 121.9 130.8 103.9 107.0 115.8 124.3 96.3 - 286 14 0.41 67 S/T 119 266 18 0.59 - - - - 63 MBh 109 - 21 0.71 101.2 104.9 114.9 111 274 19 0.73 - - - - - 59 110.3 114.3 125.2 102 269 - 120 298 15 0.64 109.7 113.7 124.5 112 277 18 0.77 - 71 Lo Pr 255 13 67 20 18 63 237 - - - 59 112.9 117.1 128.3 105 ∆T 0.40 122 - - - - - - - - - 71 95 Entering Indoor Wet Bulb Temperature 85 Outdoor Ambient Temperature Hi Pr 0.57 112 12 277 Lo Pr 16 263 18 244 ∆T 0.41 Hi Pr 0.59 0.71 S/T 124 106 112.3 116.4 127.5 113 12 280 MBh 265 0.43 Lo Pr 18 247 ∆T Hi Pr 0.62 0.74 63 S/T 59 115.6 119.8 131.3 MBh Airflow 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 Product Specifications Expanded Cooling Data — 10 Tons 22www.goodmanmfg.com SS-CPC90-150 SS-CPC90-150 www.goodmanmfg.com 3200 4000 4500 3200 4000 4500 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 22 24 28 244 105 ∆T Hi Pr Lo Pr 112 263 28 0.86 122 277 26 0.78 130 289 23 0.63 111 274 28 0.93 118 295 28 0.89 122 129 311 26 0.81 133 138 325 23 0.65 142 335 21 116 311 28 0.95 119 321 26 123 335 28 0.92 127 346 25 134 354 26 0.83 138 365 24 121 355 29 0.98 125 366 25 1.00 129 382 28 0.95 133 394 25 0.98 141 403 27 0.85 145 416 24 0.89 150 420 23 0.69 155 433 21 0.72 127 399 28 1.00 131 411 24 1.00 133 Shaded area reflects AHRI (TVA) conditions 143 369 23 0.67 147 381 21 0.70 156 22 416 0.89 115 321 24 0.86 147 20 438 1.00 109.1 111.2 116.5 124.3 106.6 108.6 113.8 121.4 104.0 106.1 111.1 118.5 101.5 103.5 108.4 115.6 96.4 134 304 25 0.95 135 23 420 0.75 S/T 126 282 25 0.98 126 24 398 0.93 MBh 116 298 20 0.68 149 23 369 1.00 109 286 23 0.84 140 20 384 1.00 126 Lo Pr 271 25 0.93 128 23 369 0.73 149 25 0.96 120 24 349 0.90 140 26 395 252 0.65 143 24 324 1.00 128 18 416 ∆T 0.81 135 20 338 1.00 120 22 399 Hi Pr 0.89 123 23 324 0.71 142 378 26 152 468 24 0.92 154 472 23 0.96 146 449 22 0.74 162 488 20 0.75 164 493 20 0.78 156 468 18 0.55 136 455 22 1.00 137 459 20 1.00 130 437 25 0.98 135 430 28 0.98 148 454 26 0.89 21 18 15 166 533 132 441 26 1.00 159 522 21 0.97 151 496 21 0.75 170 544 18 0.79 161 517 16 0.56 95.8 102.5 156 511 0.58 140 475 26 0.99 91.1 144 489 23 1.00 168 539 19 0.75 153 501 24 0.89 163 523 21 0.72 95.4 101.7 158 517 22 0.93 98.7 103.3 110.2 146 494 21 1.00 139 470 24 0.92 89.7 143 484 0.77 kW = Total system power Amps = outdoor unit amps (comp.+fan) 157 473 23 0.72 98.3 103.0 109.8 89.3 140 443 24 1.00 141 447 22 1.00 134 425 25 0.91 96.8 103.5 110.6 87.8 0.93 116 24 307 0.88 133 351 27 0.97 134 S/T 136 24 285 0.97 122 366 18 0.53 161 110 127 19 301 1.00 114 350 22 0.71 151 22 450 118.2 120.5 126.2 134.7 115.5 117.7 123.3 131.5 112.7 114.9 120.3 128.4 110.0 112.1 117.4 125.3 104.5 106.5 111.5 119.0 96.8 117 22 289 0.69 136 332 25 0.88 138 16 483 MBh 273 0.85 128 308 27 0.93 130 20 463 Lo Pr 24 254 ∆T Hi Pr 0.94 117 321 18 0.52 153 23 438 0.95 0.97 110 308 22 0.69 144 24 407 1.00 121.8 124.1 130.0 138.7 118.9 121.2 127.0 135.5 116.1 118.4 124.0 132.2 113.3 115.5 120.9 129.0 107.6 109.7 114.9 122.6 99.7 101.6 106.4 113.5 129 292 25 0.85 132 16 429 0.57 S/T 121 271 27 0.91 124 20 412 0.77 168 MBh 111 286 17 0.50 146 23 390 0.94 158 539 14 0.61 97.2 103.8 111.0 144 517 18 0.81 104 275 22 0.67 137 362 24 1.00 136 489 20 1.00 Lo Pr 260 25 0.83 126 377 16 0.55 162 455 20 1.00 26 0.88 118 361 20 0.74 152 488 15 0.60 242 0.49 140 342 23 0.91 140 468 19 0.81 ∆T 0.65 132 318 24 0.97 131 443 22 1.00 Hi Pr 0.80 121 331 16 0.54 155 22 411 0.85 114 318 20 0.72 145 15 433 1.00 107.2 109.6 117.1 125.2 104.8 107.0 114.4 122.3 102.3 104.5 111.6 119.3 99.8 101.9 108.9 116.4 94.8 133 301 23 0.88 133 19 416 0.58 S/T 125 280 24 0.94 125 22 394 0.78 MBh 114 295 16 0.52 147 23 366 0.95 107 283 20 0.70 138 15 381 1.00 Lo Pr 268 23 0.86 127 19 365 0.56 24 0.92 119 22 346 0.75 249 0.50 142 23 321 0.92 ∆T 0.67 133 15 335 1.00 Hi Pr 0.83 122 19 321 0.55 0.88 115 22 304 0.73 S/T 134 23 282 0.90 109 126 15 298 0.96 116.2 118.7 126.9 135.6 113.5 116.0 123.9 132.4 110.8 113.2 121.0 129.3 108.1 110.4 118.0 126.1 102.7 104.9 112.1 119.8 95.1 116 19 286 0.53 MBh 271 0.71 Lo Pr 23 252 ∆T Hi Pr 0.87 0.93 67 115 S/T 63 105 119.7 122.3 130.7 139.7 116.9 119.4 127.6 136.4 114.1 116.6 124.6 133.2 111.3 113.8 121.5 129.9 105.8 108.1 115.5 123.4 98.0 100.1 107.0 114.3 59 95 Entering Indoor Wet Bulb Temperature 85 Outdoor Ambient Temperature MBh Airflow 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65 Product Specifications Expanded Cooling Data — 10 Tons (cont.) 23 145.5 0.80 23 10.50 36.5 249 102 141.3 0.76 24 10.42 36.3 247 101 130.4 0.73 26 10.17 35.5 240 97 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 3360 4200 4725 59 143.1 0.70 20 10.42 36.3 247 100 138.9 0.67 20 10.33 36.0 244 99 128.2 0.65 23 10.09 35.3 237 97 Airflow MBh S/T ∆T kW 4725 Amps Hi PR Lo PR MBh S/T ∆T kW 4200 Amps Hi PR Lo PR MBh S/T ∆T 3360 kW Amps Hi PR Lo PR 149.8 0.71 21 10.72 37.2 268 108 145.4 0.68 22 10.64 36.9 266 107 134.2 0.66 24 10.38 36.2 258 104 63 148.3 0.59 17 10.64 36.9 266 107 144.0 0.56 18 10.55 36.7 263 106 132.9 0.54 20 10.30 35.9 255 103 162.1 0.54 17 11.06 38.2 283 118 157.4 0.52 18 10.97 37.9 281 117 145.3 0.50 20 10.71 37.1 272 113 67 162.5 0.41 13 10.97 37.9 281 117 157.7 0.39 13 10.88 37.6 278 116 145.6 0.37 15 10.62 36.8 269 112 174.0 0.35 12 11.41 39.3 296 126 169.0 0.33 12 11.32 39.0 293 124 155.9 0.32 14 11.05 38.1 284 121 71 142.1 0.83 23 11.31 38.8 280 107 138.0 0.79 24 11.22 38.5 277 106 127.3 0.76 27 10.94 37.7 269 103 59 139.7 0.73 20 11.21 38.5 277 106 135.7 0.69 21 11.12 38.3 274 105 125.2 0.67 23 10.86 37.4 266 102 146.3 0.74 21 11.55 39.6 301 114 142.1 0.71 22 11.46 39.3 298 113 131.1 0.68 24 11.18 38.4 289 110 63 144.8 0.61 17 11.45 39.3 298 113 140.6 0.58 18 11.36 39.0 295 112 129.8 0.56 20 11.09 38.2 286 108 158.4 0.56 17 11.92 40.6 318 125 153.8 0.53 18 11.82 40.3 315 123 141.9 0.52 20 11.53 39.4 305 120 67 158.7 0.42 13 11.82 40.3 315 123 154.1 0.40 14 11.73 40.0 312 122 142.2 0.39 15 11.44 39.1 302 118 75 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65 170.0 0.36 12 12.31 41.8 332 133 165.0 0.34 12 12.21 41.5 328 131 152.3 0.33 14 11.91 40.6 319 127 71 138.7 0.85 23 12.02 41.5 318 111 134.7 0.81 24 11.92 41.2 315 110 124.3 0.78 27 11.63 40.3 306 107 154.6 0.57 17 12.68 43.4 362 129 150.1 0.55 18 12.57 43.1 358 128 138.5 0.53 20 12.26 42.1 347 124 165.9 0.37 12 13.10 44.7 377 138 161.1 0.35 12 12.99 44.4 374 137 148.7 0.34 14 12.67 43.4 362 132 135.3 0.88 23 12.65 43.8 363 117 131.4 0.84 24 12.54 43.4 359 116 121.3 0.81 27 12.23 42.5 348 112 139.3 0.78 21 12.92 44.6 390 125 135.3 0.75 22 12.82 44.3 386 123 124.9 0.72 25 12.50 43.3 375 120 150.8 0.59 17 13.35 45.8 412 136 146.4 0.57 18 13.24 45.5 408 135 135.2 0.55 20 12.91 44.5 396 131 161.9 0.38 12 13.80 47.3 430 145 157.2 0.36 13 13.68 46.9 425 143 145.1 0.35 14 13.34 45.8 413 139 Shaded area reflects ACCA (TVA)Rating Conditions 142.8 0.76 21 12.28 42.3 343 119 138.7 0.72 22 12.18 42.0 339 117 128.0 0.70 24 11.88 41.0 329 114 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 136.4 141.4 154.9 133.1 137.9 151.1 0.75 0.62 0.43 0.77 0.64 0.45 20 17 13 20 17 13 11.92 12.18 12.57 12.54 12.82 13.24 41.2 42.0 43.1 43.4 44.3 45.5 315 339 358 359 386 408 110 117 128 116 123 135 132.4 137.3 150.4 129.2 133.9 146.7 0.71 0.60 0.41 0.74 0.61 0.43 21 18 14 21 18 14 11.82 12.08 12.47 12.44 12.71 13.13 40.9 41.7 42.8 43.1 44.0 45.2 312 336 355 355 382 404 109 116 127 115 122 133 122.2 126.7 138.8 119.3 123.6 135.4 0.69 0.57 0.40 0.71 0.59 0.41 23 20 15 23 20 15 11.53 11.78 12.16 12.13 12.39 12.80 40.0 40.7 41.8 42.1 43.0 44.1 303 326 344 345 371 392 106 113 123 111 118 129 132.4 0.81 21 13.47 47.0 439 131 128.5 0.78 22 13.36 46.6 435 129 118.6 0.75 24 13.03 45.6 422 125 63 131.0 0.67 17 13.36 46.6 434 129 127.2 0.64 18 13.25 46.3 430 128 117.4 0.61 20 12.92 45.2 417 124 143.3 0.62 17 13.92 48.3 463 143 139.1 0.59 18 13.80 47.9 459 141 128.4 0.57 20 13.45 46.8 445 137 67 143.6 0.46 13 13.80 47.9 459 141 139.4 0.44 13 13.68 47.5 454 140 128.7 0.43 15 13.34 46.4 441 135 153.8 0.40 12 14.39 49.8 483 152 149.3 0.38 12 14.27 49.4 479 150 137.8 0.36 14 13.90 48.3 464 146 71 119.1 0.92 21 13.64 48.3 451 127 115.6 0.88 22 13.53 47.9 446 126 106.7 0.84 25 13.19 46.8 433 122 59 117.1 0.81 18 13.52 47.9 446 126 113.7 0.77 19 13.41 47.6 442 124 104.9 0.74 21 13.07 46.5 428 121 122.6 0.82 20 13.95 49.3 485 135 119.1 0.78 20 13.83 48.9 480 134 109.9 0.75 23 13.48 47.8 466 130 63 121.4 0.67 16 13.83 48.9 480 134 117.9 0.64 17 13.71 48.5 475 132 108.8 0.62 18 13.37 47.4 461 128 132.7 0.62 16 14.41 50.7 512 147 128.9 0.59 17 14.29 50.3 507 146 118.9 0.57 19 13.93 49.1 492 142 67 133.0 0.47 12 14.29 50.3 507 146 129.1 0.45 13 14.17 49.9 502 144 119.2 0.43 14 13.81 48.7 487 140 115 142.5 0.40 11 14.90 52.3 534 157 138.3 0.38 12 14.77 51.9 529 155 127.7 0.37 13 14.40 50.7 513 151 71 - KW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 128.6 0.91 23 13.18 46.0 408 123 124.8 0.87 24 13.07 45.7 404 121 115.2 0.84 26 12.74 44.7 392 118 59 126.4 0.80 20 13.07 45.7 404 121 122.7 0.76 21 12.96 45.4 400 120 113.3 0.74 23 12.64 44.3 388 117 105 Product Specifications Expanded Cooling Data — 12½ Tons 24www.goodmanmfg.com SS-CPC90-150 SS-CPC90-150 www.goodmanmfg.com 150.7 0.92 27 10.67 37.0 254 104 146.3 0.88 28 10.58 36.8 252 103 135.0 0.85 31 10.33 36.0 244 99 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 3360 4200 4725 59 148.1 0.88 25 10.58 36.8 252 103 143.8 0.84 26 10.50 36.5 249 102 132.7 0.81 29 10.25 35.8 242 98 Airflow MBh S/T ∆T kW 4725 Amps Hi PR Lo PR MBh S/T ∆T kW 4200 Amps Hi PR Lo PR MBh S/T ∆T 3360 kW Amps Hi PR Lo PR 153.6 0.89 26 10.89 37.7 274 110 149.1 0.85 28 10.81 37.5 271 109 137.6 0.82 31 10.55 36.7 263 106 63 151.3 0.82 24 10.81 37.5 271 109 146.9 0.78 25 10.72 37.2 268 108 135.6 0.76 28 10.47 36.4 260 105 160.9 0.80 25 11.24 38.7 289 120 156.2 0.76 26 11.15 38.4 286 119 144.1 0.74 29 10.88 37.6 278 116 67 161.7 0.67 21 11.15 38.4 286 119 157.0 0.64 22 11.06 38.2 283 118 144.9 0.62 24 10.79 37.3 275 114 171.6 0.65 22 11.60 39.8 302 128 166.6 0.62 23 11.51 39.6 299 127 153.8 0.60 25 11.23 38.7 290 123 71 172.8 0.50 17 11.51 39.6 299 127 167.8 0.48 18 11.42 39.3 296 126 154.9 0.46 19 11.14 38.4 287 122 147.2 0.95 27 11.49 39.4 286 109 142.9 0.91 28 11.40 39.1 283 108 131.9 0.88 32 11.12 38.3 274 105 59 144.6 0.91 26 11.40 39.1 283 108 140.4 0.87 27 11.31 38.8 280 107 129.6 0.84 30 11.03 38.0 271 104 150.0 0.92 27 11.74 40.1 307 116 145.6 0.88 28 11.64 39.8 304 115 134.4 0.85 31 11.36 39.0 295 112 63 147.8 0.85 25 11.64 39.8 304 115 143.5 0.81 26 11.55 39.6 301 114 132.4 0.78 28 11.27 38.7 292 111 157.1 0.83 25 12.12 41.2 324 127 152.5 0.79 26 12.02 40.9 321 126 140.8 0.76 29 11.72 40.0 312 122 67 157.9 0.69 21 12.02 40.9 321 126 153.3 0.66 22 11.92 40.6 318 125 141.5 0.64 25 11.63 39.7 309 121 75 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65 167.6 0.67 22 12.51 42.4 338 135 162.7 0.64 23 12.41 42.1 335 134 150.2 0.62 25 12.10 41.2 325 130 71 168.8 0.52 17 12.41 42.1 335 134 163.9 0.49 18 12.31 41.8 332 133 151.3 0.48 20 12.01 40.9 322 129 143.7 0.98 27 12.22 42.1 325 114 139.5 0.93 28 12.12 41.8 322 113 128.7 0.90 32 11.82 40.9 312 109 153.4 0.85 25 12.89 44.1 369 132 148.9 0.81 26 12.78 43.7 365 131 137.4 0.78 29 12.47 42.8 354 127 163.6 0.69 22 13.32 45.4 385 141 158.9 0.66 23 13.21 45.1 381 139 146.6 0.63 25 12.88 44.1 370 135 140.2 1.00 27 12.86 44.4 370 119 136.1 0.96 29 12.75 44.1 366 118 125.6 0.93 32 12.43 43.1 355 115 142.9 0.97 27 13.14 45.3 398 127 138.7 0.93 28 13.03 45.0 394 126 128.0 0.89 31 12.71 43.9 382 122 149.6 0.88 26 13.57 46.5 420 139 145.3 0.84 27 13.46 46.2 416 137 134.1 0.81 30 13.12 45.1 404 133 159.6 0.71 22 14.03 48.0 438 148 155.0 0.68 23 13.91 47.6 434 146 143.0 0.65 26 13.56 46.5 421 142 Shaded area reflects ACCA (TVA)Rating Conditions 146.4 0.94 27 12.48 42.9 349 121 142.2 0.90 28 12.38 42.6 346 120 131.2 0.87 31 12.08 41.6 336 116 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 141.2 144.3 154.1 164.8 137.7 140.8 150.4 160.8 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 26 25 21 17 26 25 21 17 12.12 12.38 12.78 13.21 12.75 13.03 13.46 13.91 41.8 42.6 43.7 45.1 44.1 45.0 46.2 47.6 322 346 365 381 366 394 416 434 113 120 131 139 118 126 137 146 137.1 140.1 149.7 160.0 133.7 136.7 146.0 156.1 0.89 0.83 0.68 0.51 0.92 0.86 0.70 0.52 27 26 22 18 27 26 22 18 12.02 12.28 12.68 13.10 12.65 12.93 13.35 13.80 41.5 42.3 43.4 44.7 43.8 44.6 45.9 47.3 318 343 362 377 363 390 412 430 111 119 129 138 117 125 136 145 126.5 129.3 138.1 147.7 123.4 126.1 134.8 144.1 0.86 0.80 0.65 0.49 0.88 0.83 0.67 0.50 30 28 25 20 30 29 25 20 11.72 11.98 12.36 12.77 12.33 12.60 13.01 13.45 40.6 41.3 42.4 43.7 42.8 43.6 44.8 46.2 309 332 351 366 352 378 400 417 108 115 126 134 114 121 132 140 135.7 1.00 26 13.70 47.7 448 133 131.8 0.96 28 13.59 47.3 443 132 121.6 0.93 31 13.24 46.3 430 128 63 133.7 0.94 24 13.59 47.3 443 132 129.8 0.89 25 13.47 47.0 439 131 119.8 0.86 28 13.13 45.9 426 127 142.1 0.91 25 14.16 49.0 473 145 138.0 0.87 26 14.04 48.7 468 144 127.4 0.84 29 13.68 47.5 454 140 67 142.9 0.76 21 14.04 48.7 468 144 138.7 0.73 22 13.92 48.3 464 143 128.0 0.70 25 13.57 47.2 450 138 151.6 0.74 22 14.63 50.6 493 155 147.2 0.70 23 14.51 50.2 488 153 135.9 0.68 25 14.14 49.0 474 149 71 152.7 0.57 17 14.51 50.2 488 153 148.3 0.54 18 14.39 49.8 483 152 136.9 0.52 20 14.02 48.7 469 147 123.3 1.00 24 13.87 49.1 460 129 119.7 1.00 26 13.76 48.7 455 128 110.5 0.97 29 13.41 47.6 442 124 59 121.2 1.00 24 13.76 48.7 455 128 117.7 0.96 25 13.64 48.3 451 127 108.6 0.93 28 13.30 47.2 437 123 125.7 1.00 24 14.18 50.1 495 138 122.1 0.97 26 14.06 49.7 490 136 112.7 0.94 29 13.71 48.5 475 132 63 123.9 0.94 23 14.06 49.7 490 136 120.3 0.90 24 13.95 49.3 485 135 111.0 0.87 26 13.59 48.2 470 131 131.7 0.92 24 14.66 51.5 522 150 127.8 0.88 25 14.53 51.1 517 149 118.0 0.84 27 14.16 49.9 502 144 67 132.3 0.77 20 14.53 51.1 517 149 128.5 0.73 21 14.41 50.7 512 147 118.6 0.71 23 14.04 49.5 497 143 115 140.5 0.75 20 15.16 53.1 545 160 136.4 0.71 21 15.03 52.7 539 159 125.9 0.69 24 14.64 51.5 523 154 71 141.5 0.57 16 15.03 52.7 539 159 137.3 0.55 16 14.90 52.3 534 157 126.8 0.53 18 14.52 51.1 518 152 KW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 133.1 1.00 26 13.40 46.8 416 125 129.3 1.00 28 13.29 46.4 412 124 119.3 0.96 31 12.96 45.3 400 120 59 130.9 1.00 25 13.29 46.4 412 124 127.0 0.95 26 13.18 46.1 408 123 117.3 0.92 29 12.85 45.0 396 119 105 Product Specifications Expanded Cooling Data — 12½ Tons (cont.) 25 Product Specifications APPENDIX C UNIT DIMENSIONS Dimensions 7.5 Y 8.5 10 12.5 52 7/8" 52 7/8" 52 7/8" 58 7/8" L 99 1/8” Y H Model Size 7½ to 10 Tons 12½ Tons Dimensions H L 52⅞” 58⅞” 99⅛” 99⅛” 61¾” 61 3/4” 12⅝” 12 5/8” 28⅜” 28 3/8” 77⅜” 3/8” RETURN 13⅞” 13 7/8” 55⅞” 7/8” 36⅜” 36 3/8” SUPPLY 66½” 1/2” RETURN 66¼” 1/4” Horizontal Discharge NOTE 5 3/8” 5⅜” For horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply openings. Install with insulation facing up, using the longer screws provided in the literature package. SUPPLY 77½” 1/2” Vertical Discharge (Bottom of Unit) 20 26www.goodmanmfg.com SS-CPC90-150 Product Specifications Unit Clearances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake. 48” 48” 36” Min. 75” 48” Electrical Entrance Locations Dimples Mark Drill Locations 11⅝” High-Voltage Entrance 103/16” Low-Voltage Entrance 3” SS-CPC90-150 www.goodmanmfg.com 27 Product Specifications Roof Curb Installation — Rigging Provisions for forks have been included in the unit base frame. No other fork locations are approved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables should be attached to the unit with shackles. • The distance between the crane hook and the top of the unit must not be less than 60”. • Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Lower unit carefully onto roof mounting curb. 30” While rigging the unit, the center of gravity will cause the condenser end to be lower Compressor 1 than the supply air end. Bring condenser end of unit into alignment Compressor 2 with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and 49” return openings with duct. Return Evaporator Coil Supply Corner & Center-of-Gravity Locations Unit Weights 7½-Ton A Models Weights (lbs) 7½-Ton B Models & 8½-Ton Weights (lbs) 10-Ton Weights (lbs) 12½-Ton Weights (lbs) Weight A 280 260 285 420 Weight B 280 245 285 335 Weight C 280 240 285 290 Weight D 280 225 285 230 Shipping Weight 1150 1000 1175 1300 Operating Weight 1110 975 1135 1275 To assist in determining rigging requirements, unit weights are shown to the right. Note: These weights are calculated without accessories installed. 28www.goodmanmfg.com SS-CPC90-150 Product Specifications Roof Curb Installation (cont.) 3-D View 92¼ 15⅜ x 31⅛ Supply Opening 14⅝ x 38⅜ Return Opening Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. • Determine sufficient structural support before locating and mounting the curb and package unit. • Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory. • Contractor furnishes curb insulation, cant strips, flashing, and general roofing material. • Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members 53¼ cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not 14 recommended. See the manual shipped with the roof curb for 1⅝ assembly and installation instructions. ¾ 14 1⅜ Top View Power Wiring Thermostat Wiring Power and Low-Voltage Block Locations SS-CPC90-150 www.goodmanmfg.com 29 Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ Product Specifications Wiring Diagram — CPC090-120 (for models with serial numbers 0907 and below) 30www.goodmanmfg.com SS-CPC90-150 Product Specifications Wiring Diagram — CPC090-120 (cont.) (for models with serial numbers 0907 and below) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. SS-CPC90-150 ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com ⚡ 31 Product Specifications Wiring Diagram — CPC090-150 SMOKE/FIRE DETECTOR REPLACES JUMPER RD G BL BR RD GR SPEED UP NO K1 COM K1 NOTE #2 NC M1 M2 C S1 PK RD GR 2 3 RD BL YL 208 240 460 575 T3 RD L3 L2 T2 C 24V L1 T1 BL BL PU BK BL TR 1 BR S2 EBTDR R XFMR-R XFMR-C C TB1 OR BK OR CC2 BK YL BK RD SEE NOTE #2 OR RD PB P O W E R S U P P L Y BL BL BK BL BK OR BK L1 RD OR GR L3 L2 PU T1 T2 BK YL COMP2 CM2 L2 BK GND C L1 T1 BK CC1 BR BK T3 T2 T1 BK RD L3 T2 BK RD T3 T2 T1 BK T3 BC BL BR T3 RD F PU C BK YL RCCF2 C YL RD BR OR YL RD RCCF1 BK C BK BR PU F CM1 COMP1 RD OR 2 0 8 2 4 0 4 6 0 5 7 5 / 3 / 6 0 PU YL SEE NOTE 3 PLF 2 BK BL HPS1 LPS1 GR BK 9 OR BK BL 3 6 8 5 2 7 4 1 YL EM PU WH PU WH YL BK WH PLF 1 3 6 9 2 5 8 1 4 7 YL PU RD GR WH BR BL RD RD PU BR BL OR WH O ++ TB1 BL YL LPS2 T H E R M O S T A T Y1 Y/Y2 R G W1 W2 C SEE NOTE 4 HPS2 0140L00548 REV B Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ 32www.goodmanmfg.com SS-CPC90-150 Product Specifications Wiring Diagram — CPC090-150 (cont.) L2 L1 L3 COMPONENT LEGEND SUPPLY VOLTAGE BC CC CM CMR COMP DC DFT ECON EBTD EMR R EM FC GND HPS HVDR LPS LVDR PB PLF RVC RCCF 208-240/460/575/3/60 T2 T2 CC1 T1 CC1 COMP1 T3 CC1 T3 C RCCF1 F CM1 C RCCF2 F CM2 T2 CC2 T2 T1 T1 TB1 TR CC2 COMP2 BLOWER CONTACTOR COMPRESSOR CONTACTOR CONDENSER MOTOR CONDENSER MOTOR RELAY COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY POWER DISTRUBTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER T3 CC2 T3 FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHIT E YL YELLOW YL/PK YELLOW WITH PINK STRIP BL/PK BLUE WITH PINK STRIP THERMOSTAT FIELD WIRING BC ++ 2 STAGE COOLING BC NOTES: EM BC 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT, REMOVE MALE PLUG, ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. FOR TWO STAGE OPERATION REMOVE W1 TO W2 WIRE JUMPER. 5. FOR 208V OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON 240V TRANSFORMER. 208-240V OR APPROPRIATE INPUT VOLTAGE S2 3 1 TB1 S1 TR 24V EBTDR R C G W1 G R Y1 Y/Y2 C O W2 WH GR W1 G R Y1 Y2 C O W2 RD YL TB1 PK BL OR BR STAT BC R EBTDR EBTDR LPS1 PLF1 7 4 8 5 9 6 CC1 SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION HPS2 CC2 HPS1 LPS2 PLF2 9 6 3 8 5 2 7 4 1 SEE NOTE 4 TB1 R W2 O Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. SS-CPC90-150 W1 Y/ Y2 THERMOSTAT ⚠ Y1 ++ G Warning C SEE NOTE 3 208-240/460/575/3/60 0140L00549 REV. B High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com ⚡ 33 Product Specifications Accessories Item # Description Fits Model Sizes 14CURB90150 Roof Curb 14" Tall 7½-12½ tons 25FD90150 25% Manual Fresh Air Damper 7½-12½ tons 25MFD90150 25% Motorized Fresh Air Damper 7½-12½ tons BRD3672 Horizontal Barometric Relief Damper (two required) 7½-12½ tons CDK120 Concentric Duct Kit 10 tons CDK150 Concentric Duct Kit 12½ tons CDK90102 Concentric Duct Kit 7½-8½ tons DNBBS90150 Burglar Bar Sleeves: Includes Supply & Return 7½-12½ tons DNECONGS90120 Downflow Economizer 7½-10 tons DNECONGS150 Downflow Economizer 12½ tons DNSQRRND90 Downflow Square-to-Round Adapter 20" Round 7½ tons GHRC-1 Hurricane Restraint Clip All Models HailGD02 Condenser Coil Hail Guard 7½-10 tons HailGD05 Condenser Coil Hail Guard 12½ tons HSKT090 High-Static Kit for 7½-ton AA models & 8½-ton AA models (230/460v) HSKT090G High-Static Kit for BA models (230/460v) 7½ tons HSKT120 High-Static Kit for AA models (230/460v) 10 tons HSKT150 High-Static Kit for AA models (230/460v) HZECONGS90150 Horizontal Economizer 7½-8½ tons 12½ tons 7½-12½ tons LAKT02 Low-Ambient Kit for units with serial number below 0909 7½ - 12½ tons LAKT03 Low Ambient Kit for units with serial numbers 0909 and above 7½ - 12½ tons PE901502 Power Exhaust 208/230 Volt 7½-12½ tons PE901504 Power Exhaust 460 Volt 7½-12½ tons 34www.goodmanmfg.com SS-CPC90-150 Product Specifications Notes SS-CPC90-150 www.goodmanmfg.com 35 Product Specifications Notes Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2011 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 36www.goodmanmfg.com SS-CPC90-150