CPC C ommercial
7½- to 12½-Ton Three-Phase
Packaged Air Conditioners
Cooling Capacity: 90,000 — 118,000 BTU/h
up to
11.5 EER
Standard Features
•
•
•
•
•
•
•
•
•
•
•
•
•
R-410A chlorine-free refrigerant
High-efficiency scroll compressor
Copper tube / aluminum fin coils
Contactor with lugs
High- and low-pressure switches
High-capacity, steel-cased filter dryer
Heater kits with single-point entry
24-volt terminal strip
Convertible
Easy to service
Built-in filter rack with standard 2” filters
Bottom utility entry
AHRI Certified; ETL Listed
Contents
Nomenclature...................................................................................................2
Product Specifications.................................................................................3
Airflow Data........................................................................................................7
Heat Kit Electrical Data . .......................................................................... 11
Expanded Cooling Data........................................................................... 16
Dimensions...................................................................................................... 26
Wiring Diagrams ......................................................................................... 30
Accessories...................................................................................................... 34
Cabinet Features
• Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish
• Full Perimeter Rail
* Complete warranty details available from your local dealer or at www.goodmanmfg.com.
SS-CPC90-150
www.goodmanmfg.com
6/11
Supersedes 3/11
Product Specifications
Nomenclature
Brand
C
C
1
P
2
C
3
150
4,5,6
Commercial
3
10
B
11
X
12
X
13
X
14
X
A
B
C
F
Configura;on
P
Packaged Unit
Applica;on
C
Cooling
G
Gas Heat
H
Heat Pump
Nominal Gross Cooling Capacity 036 3 Tons
102
048 4 Tons
120
060 5 Tons
150
072 6 Tons
180
090 7½ Tons
240
045
7,8,9
M
X
A
B
8½ Tons
10 Tons
12½ tons
15 Tons
20 Tons
C
D
Nominal Hea;ng Capacity
CPG 045 45,000 BTU/h
090 90,000 BTU/h
115 115,000 BTU/h
140 140,000 BTU/h
210 210,000 BTU/h
350 350,000 BTU/h
400 400,000 BTU/h
Voltage
1
208V 1-­‐Phase
2
220/240V 1-­‐Phase 50 Hz
3
208/230V 3-­‐Phase
CPC/CPH (Factory-­‐Installed Electric Heat)
XXX No Heat
010 10 kW
030 30 kW
015 15 kW
031 30 kW
016 15 kW
045 45 kW
018 18 kW
046 45 kW
020 20 kW
060 60 kW
025 25 kW
075 75 kW
4 460V 3-­‐Phase
5 380/415V 3-­‐Phase 50 Hz
7 575V 3-­‐Phase
J
S
T
X
A
B
D
H
Factory-­‐Installed Op;ons
No Op:ons
Non-­‐powered convenience outlet
Powered convenience outlet
Low-­‐ambient kit
Non-­‐powered convenience outlet; Low-­‐ambient kit
Powered convenience outlet;
Low-­‐ambient kit
Factory-­‐Installed Op;ons
Standard Aluminized Heat Exchanger Condenser Coil Hail Guard
Condenser Coil Hail Guard
Treated Condenser Coil (UltraGold)
Condenser Coil Hail Guard
Stainless Steel Heat Exchanger
Condenser Coil Hail Guard
Treated Condenser Coil (UltraGold)
Stainless-­‐Steel Heat Exchanger
Treated Condenser Coil (UltraGold)
Stainless-­‐Steel Heat Exchanger
Treated Condenser Coil (UltraGold)
Stainless-­‐Steel Heat Exchanger
Factory-­‐Installed Op;ons
No Op:ons
Downflow Economizer
Supply Fan/Drive Type/Motors
Belt Drive
Direct Drive
High-­‐Sta:c Belt Drive (Factory-­‐Installed)
Factory-­‐Installed Op;ons
•
•
•
•
•
•
•
•
•
Condenser Hail Guards: Louvered metal guards help protect the condenser coil from damage from hail and debris. Available as a factory-­‐installed op:on on 3-­‐ to 12½-­‐ton units. Hail guards are standard on 15-­‐ and 20-­‐ton units.
Stainless-­‐Steel Heat Exchanger (CPG units only): A tubular heat exchanger made of 409-­‐type stainless steel is installed in the unit.
Ultra-­‐Gold Condenser Coil: Offers increased corrosion resistance of the condenser coil.
Low-­‐Ambient Kit: Allows for cooling opera:on at lower outdoor temperatures. On the 3-­‐ to 6-­‐ton units, cooling opera:on is extended from 60°F ambient temperature to 35°F outside air temperature. On 7½-­‐ to 20-­‐ton units, cooling opera:on is extended from 35°F ambient temperature to 0°F outside air temperature. Economizers (Downflow): Based on air condi:ons, can provide outside air to cool the space.
High Sta:c Kits: Provides airflow in higher sta:c applica:ons.
Electric Heat Kits (CPC and CPH units only): Available in all voltage op:ons.
Non-­‐powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet.
Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit.
2www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Product Specifications — 7½ Tons
A Models
B Models
CPC090
XXX3BXXX
CPC090
XXX4BXXX
CPC090
XXX3BXXX
CPC090
XXX4BXXX
CPC090
XXX7BXXX
Total BTU/h
90,000
90,000
90,000
90,000
90,000
Sensible BTU/h
65,700
65,700
64,000
64,000
64,000
11.5 / 11.5
11.5 / 11.5
11.5 / 11.5
11.5 / 11.5
11.5 / 11.5
Cooling Capacity
EER / IEER
Decibels
AHRI Reference #s
82.0
82.0
82.0
82.0
82.0
3000986
3000986
3620223
3620223
3620223
Belt Drive
Belt Drive
Belt Drive
Belt Drive
Belt Drive
3,000
3,000
3,000
3,000
3,000
7.8
3.9
5.0
2.5
2.3
2.0 / 1725
2.0 / 1725
1.5 / 1745
1.5 / 1745
1.5 / 1725
Evaporator Motor / Coil
Motor Type
Indoor Nominal CFM
Indoor Motor FLA (Cooling)
Horsepower / RPM
Piston Size (Cooling)
Filter Size (Qty)
Drain Size (NPT)
R-410A Refrigerant Charge Cir #1 & #2
0.076
0.076
0.078
0.078
0.078
(4) 16”x24”x2”
(4) 16”x24”x2”
(4) 16”x20”x2”
(4) 16”x20”x2”
(4) 16”x20”x2”
¾”
¾”
¾”
¾”
¾”
215 oz.
215 oz.
175 oz.
175 oz.
175 oz.
Evaporator Coil Face Area (ft²)
10.2
10.2
8.9
8.9
8.9
Rows Deep / Fins per Inch
4 / 16
4 / 16
4 / 16
4 / 16
4 / 16
# of Wheels (D x W)
1 (15” x 12”)
1 (15” x 12”)
1 (15” x 12”)
1 (15” x 12”)
1 (15” x 12”)
Motor Sheave / Blower Sheave
VL40 / AK74
VL40 / AK74
VL40 / AK74
VL40 / AK74
VL40 / AK74
AX51
AX51
AX51
AX51
AX51
Belt Drive Evap Fan Data
Belt
Condenser Fan / Coil
Quantity of Condenser Fan Motors
2
2
2
2
2
¼ - 1090
¼ - 890
¼ - 1075
¼ - 890
¼ - 1,075
Fan Diameter / # Fan Blades
22 / 4
22 / 4
22 / 4
22 / 4
22 / 4
Outdoor Nominal CFM
7,600
7,600
7,600
7,600
7,600
Face Area (ft²)
32.4
32.4
26.5
26.5
26.5
Rows Deep / Fins per Inch
2 / 20
2 / 20
2 / 22
2 / 22
2 / 22
2 / Scroll
2 / Scroll
2 / Scroll
2 / Scroll
2 / Scroll
1
1
1
1
1
Voltage-Phase-Frequency
208/230-3-60
460-3-60
208/230-3-60
460-3-60
575-3-60
Quantity of Compressors
2
2
2
2
2
13.1 / 83.1
6.1 / 41.0
13.1 / 83.1
6.1 / 41.0
4.4 / 33.0
Horsepower - RPM
Compressor
Quantity / Type
Stage
Electrical Data
Compressor RLA / LRA
Max External Static
Outdoor Fan HP / RLA
Total Unit Amps
1.5”
1.5”
1.0”
1.0”
1.0”
(2) ¼ / 1.4
(2) ¼ / 0.8
(2) ¼ / 1.4
(2) ¼ / 0.8
(2) ¼ / 0.6
36.9
17.7
34.0
16.3
12.3
Min. Circuit Ampacity¹
40
19
37.3
17.8
13.4
Max. Overcurrent Protection (amps)²
50
25
50
20
15
Entrance Control Voltage
Locating
Dimple
Locating
Dimple
Locating
Dimple
Locating
Dimple
Locating
Dimple
Operating Weight (lbs)
1110
1110
975
975
975
Ship Weight (lbs)
1150
1150
1000
1000
1000
Entrance Power Supply
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
SS-CPC90-150 www.goodmanmfg.com
3
Product Specifications
Product Specifications — 8½ Tons
CPC102
XXX3BXXX
CPC102
XXX4BXXX
CPC102
XXX7BXXX
102,000
102,000
102,000
Cooling Capacity
Total, BTU/h
Sensible BTU/h
EER / IEER
Decibels
70,380
70,380
70,380
11.3 / 11.2
11.3 / 11.2
11.3 / 11.2
83
83
83
3620220
3620220
3620220
Belt Drive
Belt Drive
Belt Drive
3,400
3,400
3,400
7.8
3.9
2.3
Horsepower - RPM
1725
1725
1725
Piston Size (Cooling)
0.08
0.08
0.08
(4) 16” x 20” x 2”
(4) 16” x 20” x 2”
(4) 16” x 20” x 2”
ARI Reference #s
Evapoartor Motor / Coil
Motor Type
Indoor Nominal CFM
Indoor Motor FLA (Cooling)
Filter Size (Qty)
Drain Size (NPT)
R-410A Refrigerant Charge Cir #1 & #2
Evaporator Coil Face Area (ft2)
3/4"
3/4"
3/4"
180 oz.
180 oz.
180 oz.
8.9
8.9
8.9
4 / 16
4 / 16
4 / 16
# of Wheels (D x W)
1 (15" x 12")
1 (15" x 12")
1 (15" x 12")
Motor Sheave / Blower Sheave
VL40 / AK74
VL40 / AK74
VL40 / AK74
AX51
AX51
AX51
2
2
2
Rows Deep / Fins per Inch
Belt Drive Evap Fan Data
Belt
Condenser Fan / Coil
Quantity of Condenser Fan Motors
Horsepower - RPM
1/4" - 1,090
1/4" - 890
1/4" - 1,075
Fan Diameter / # Fan Blades
22 / 4
22 / 4
22 / 4
Outdoor Nominal CFM
7,600
7,600
7,600
Face Area (ft2)
13.25
13.25
13.25
Rows Deep / Fins per Inch
2 / 22
2 / 22
2 / 22
2 / Scroll
2 / Scroll
2 / Scroll
1
1
1
575 / 3 / 60
Compressor
Quantity / Type
Stage
Electrical Data / Static
Voltage / Phase / Frequency
230 / 3 / 60
460 / 3 / 60
Quantity of Compressors
2
2
2
Compressor RLA / LRA ea.
14.5 / 98
6.3 / 55
6.0 / 41
Standard Max Static
1"
1
1
Outdoor Fan FLA ea.
1.4
0.8
0.6
Total Unit Amps
39.6
18.1
15.5
Min. Circuit Ampacity¹
43.2
19.7
17
50
25
20
Locating
Dimple
Locating
Dimple
Locating
Dimple
Max. Overcurrent Protection (amps)²
Entrance Power Supply
Entrance Control Voltage
Operating Weight (lbs)
975
975
975
Ship Weight (lbs)
1000
1000
1000
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
4www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Product Specifications — 10 Tons
CPC120
XXX3BXXX
CPC120
XXX4BXXX
CPC120
XXX7BXXX
118,000
118,000
118,000
Cooling Capacity
Total BTU/h
Sensible BTU/h
EER / IEER
Decibels
87,300
87,300
87,300
11.5 / 11.2
11.5 / 11.2
11.5 / 11.2
83.0
83.0
83.0
3023833
3023833
3023833
Belt Drive
Belt Drive
Belt Drive
4,000
4,000
4,000
7.8
3.9
2.7
Horsepower - RPM
2.0/1725
2.0/1725
2.0/1725
Piston Size (Cooling)
0.086
0.086
0.086
(4) 16” x 24” x 2”
(4) 16” x 24” x 2”
(4) 16” x 24” x 2”
ARI Reference #s
Evaporator Motor / Coil
Motor Type
Indoor Nominal CFM
Indoor motor FLA (Cooling)
Filter Size (Qty)
Drain Size (NPT)
R-410A Refrigerant Charge Cir #1 & #2
¾”
¾”
¾”
220 oz.
220 oz.
220 oz.
Evaporator Coil Face Area (ft²)
10.2
10.2
10.2
Rows Deep / Fins per Inch
4 / 14
4 / 14
4 / 14
# of Wheels (D x W)
(1) 15” x 15”
(1) 15” x 15”
(1) 15” x 15”
Motor Sheave / Blower Sheave
VL40 / AK74
VL40 / AK74
VL40 / AK74
AX51
AX51
AX51
2
2
2
Belt Drive Evap Fan Data
Belt
Condenser Fan / Coil
Quantity of Condenser Fan Motors
Horsepower - RPM
⅓ - 1,075
⅓ - 1,075
⅓ - 1,075
Fan Diameter / # Fan Blades
22 / 3
22 / 3
22 / 3
Outdoor Nominal CFM
7,200
7,200
7,200
Face Area (ft²)
32.4
32.4
32.4
2/2 rows - 22 fpi
2/2 rows - 22 fpi
2/2 rows - 22 fpi
2 / Scroll
2 / Scroll
2 / Scroll
1
1
1
208-230/3/60
460/3/60
575/3/60
2
2
2
16/110.0
7.8/52.0
5.7/38.9
Rows Deep - Fins per Inch
Compressor
Quantity / Type
Stage
Electrical Data
Voltage/Phase/ Frequency
Quantity of Compressors
Compressor RLA / LRA ea.
Standard Max Static
2.0”
2.0”
2.0”
Outdoor Fan RLA ea.
2.40
1.20
0.89
Total Unit Amps
45
22
16
Min. Circuit Ampacity¹
49
24
17
60.0
30
20
Entrance Control Voltage
Locating
Dimple
Locating
Dimple
Locating
Dimple
Operating Weight (lbs)
1135
1135
1135
Ship Weight (lbs)
1175
1175
1175
Max. Overcurrent Protection (amps)²
Entrance Power Supply
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
SS-CPC90-150 www.goodmanmfg.com
5
Product Specifications
Product Specifications — 12½ Tons
Cooling Capacity
Total, BTU/h
Sensible BTU/h
EER / IPLV
Decibels
ARI Reference #s
Evapoartor Motor / Coil
Motor Type
Indoor Nominal CFM
Indoor Motor FLA (Cooling)
Horsepower - RPM
Piston Size (Cooling)
Filter Size
Drain Size (NPT)
R-410A Refrigerant Charge Cir #1 & #2
Evaporator Coil Face Area (ft2)
Rows Deep / Fins per Inch
Condenser Fan / Coil
Quantity of condenser Fan Motors
Horsepower - RPM
Fan Diameter / # Fan Blades
Outdoor Nominal CFM
Face Area (ft2)
Rows Deep / Fins per Inch
Belt Drive Evap Fan Data
# of Wheels (D x W)
Motor Sheave / Blower Sheave
Belt
Compressor
Quantity / Type
Stage
Compressor RLA / LRA ea.
Electrical Data / Static
Voltage / Phase / Frequency
Outdoor Fan FLA ea.
Total Unit Amps
Min. Circuit Ampacity1
Max. Overcurrent Protection (amps)2
Entrance Power Supply
Entrance Control Voltage
Operating Weight (lbs)
Ship Weight (lbs)
CPC150XXX
3BXXX
CPC150XXX
4BXXX
CPC150XXX
7BXXX
146,000
102,200
11.0 / 11.2
83
3542680
146,000
102,200
11.0 / 11.2
83
3542680
146,000
102,200
11.0 / 11.2
83
3542680
Belt Drive
5,000
9.4
3.0 - 1,725
0.096
(4) 20" x 25" x 2"
¾"
285 oz.
14.7
4 / 15
Belt Drive
5,000
4.7
3.0 - 1,725
0.096
(4) 20" x 25" x 2"
¾"
285 oz.
14.7
4 / 15
Belt Drive
5,000
4.2
3.0 - 1,725
0.096
(4) 20" x 25" x 2"
¾"
285 oz.
14.7
4 / 15
2
⅓ - 1,075
22/3
7,200
35.3
2/3 rows 15 fpi
2
⅓ - 1,075
22/3
7,200
35.3
2/3 rows 15 fpi
2
⅓ - 1,075
22/3
7,200
35.3
2/3 rows 15 fpi
(1) 15" x 15"
VL40 / AK66
AX49
(1) 15" x 15"
VL40 / AK66
AX49
(1) 15" x 15"
VL40 / AK66
AX49
1 / Scroll
Single
22.4 / 149
1 / Scroll
Single
10.6 / 75
1 / Scroll
Single
7.7 / 54
208-230/3/60
2.4
59
65
80
460/3/60
1.2
28
31
40
575/3/60
0.9
21.4
23
30
Locating
Dimple
Locating
Dimple
Locating
Dimple
1275
1300
1275
1300
1275
1300
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
6www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Airflow Data — 7½ Tons
Standard Belt Drive — Down Shot
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
4
RPM
BHP
CFM
3617
704
1.07
3293
653
0.84
3541
749
1.15
3179
704
0.88
2757
656
0.66
2606
710
0.71
0.1
0.3
0.5
0.7
0.9
3303
890
1.41
1.1
2838
897
1.23
3447
798
1.23
3049
754
0.94
3400
848
1.33
2950
798
1.01
2474
754
0.75
2871
848
1.11
2408
804
0.82
RPM
5
CFM
BHP
CFM
RPM
BHP
High-Static Belt Drive — Down Shot (for A Models only)
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
CFM
RPM
4
BHP
CFM
RPM
5
BHP
0.9
1.1
1.3
DO NOT
OPERATE
1.5
1.7
1.9
3381
1119
2.22
2.1
3089
1129
2.04
CFM
RPM
BHP
3401
909
1.51
3428
965
1.71
2943
915
1.3
3471
1015
1.9
3012
971
1.5
2423
920
1.12
2503
976
1.31
CFM
RPM
BHP
CFM
RPM
BHP
3625
701
1.08
3309
660
0.86
3722
1063
2.25
3041
1023
1.67
3359
1075
2.04
2540
1031
1.5
2890
1080
1.78
Standard Belt Drive — Horizontal
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
CFM
RPM
4
BHP
0.1
0.3
3815
797
1.44
3468
747
1.11
3177
703
0.88
2796
663
0.68
3780
841
1.52
3405
803
1.23
3053
753
0.94
2608
709
0.68
2225
665
0.53
1.6
3327
847
1.29
2968
805
1.02
2423
758
0.73
2850
852
1.1
2352
807
0.8
BHP
CFM
RPM
BHP
3447
902
1.54
3006
908
1.31
0.5
0.7
3687
885
5
0.9
3236
891
1.39
1.1
2713
896
1.17
High-Static Belt Drive — Horizontal (for A Models only)
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
CFM
RPM
4
BHP
CFM
RPM
5
0.9
1.1
1.3
1.5
1.7
DO NOT
OPERATE
3388
1103
2.18
1.9
2959
1114
2.0
2.1
2527
1124
1.86
3514
1057
2.07
3036
1069
1.84
3486
1008
1.87
2949
1019
1.62
3398
956
1.65
2960
962
1.44
Notes :
Assume dry coil with filter in place; CFM correction for wet coil = 3%
Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could
require a larger motor. Minimum rated SCFM is 350 per ton.
SS-CPC90-150 www.goodmanmfg.com
7
Product Specifications
Airflow Data — 8½ Tons
Standard Belt Drive — Down Shot
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
4
RPM
BHP
CFM
3467
701
1.04
3143
650
0.81
3391
746
1.12
3029
701
0.85
2607
653
0.63
2899
751
0.91
2456
707
0.68
0.1
0.3
0.5
0.7
0.9
3153
887
1.38
1.1
2688
894
1.20
3250
845
1.30
2721
845
1.08
3297
795
1.20
2800
795
0.98
RPM
5
CFM
BHP
CFM
RPM
BHP
High-Static Belt-Drive — Down Shot
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
CFM
RPM
4
BHP
CFM
RPM
5
BHP
0.9
1.1
1.3
1.5
3572
1060
2.22
1.7
3209
1072
2.01
2740
1077
1.75
1.9
2.1
3256
1156
2.31
3231
1116
2.19
2939
1126
2.01
3321
1012
1.87
2891
1020
1.64
CFM
RPM
BHP
3251
906
1.48
2793
912
1.27
3278
962
1.68
2862
968
1.47
CFM
RPM
BHP
CFM
RPM
BHP
3475
698
1.05
3159
657
0.83
2646
660
0.65
CFM
RPM
BHP
3297
899
1.51
2856
905
1.28
Standard Belt Drive — Horizontal
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
CFM
RPM
4
BHP
0.1
0.3
0.5
5
3665
794
1.41
3318
744
1.08
3027
700
0.85
3630
838
1.49
3255
800
1.2
2903
750
0.91
2458
706
0.65
2818
802
0.99
BHP
CFM
RPM
0.7
3537
882
1.57
3177
844
1.26
0.9
3086
888
1.36
2700
849
1.07
1.1
2563
893
1.14
High-Static Belt-Drive — Horizontal
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
CFM
RPM
4
5
BHP
0.9
1.1
1.3
1.5
1.7
1.9
3188
1146
2.23
3238
1100
2.15
2809
1111
1.97
3364
1054
2.04
2886
1066
1.81
3336
1005
1.84
2799
1016
1.59
3248
953
1.62
2810
959
1.41
Notes :
Assume dry coil with filter in place; CFM correction for wet coil = 3%
Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could
require a larger motor. Minimum rated SCFM is 350 per ton.
8www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Airflow Data — 10 Tons
Standard Belt-Drive — Down Shot
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
2
BHP
CFM
4632
781
1.76
4203
742
1.41
4488
825
1.85
4183
783
1.54
3733
748
1.23
3717
786
1.31
0.6
4442
880
2.02
4066
830
1.63
0.8
4001
885
1.77
3622
835
1.41
1
3603
890
1.55
BHP
CFM
RPM
4
RPM
0.2
0.4
RPM
3
CFM
BHP
CFM
5
RPM
BHP
CFM
RPM
BHP
3927
691
1.17
3510
658
0.9
3512
693
1
1.2
High-Static Belt-Drive — Down Shot
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
CFM
RPM
4
BHP
0.8
1
1.2
1.4
1.6
1.8
2
4050
1179
3.05
4438
1116
2.97
3956
1124
2.55
3473
1132
2.32
5
CFM
RPM
BHP
CFM
RPM
BHP
4435
940
2.22
4078
886
1.82
3539
892
1.52
4462
997
2.47
4103
945
2.05
4513
1054
2.75
4127
1003
2.26
3568
950
1.71
4126
1064
2.52
3597
1008
1.92
3759
1069
2.25
Standard Belt-Drive — Horizontal
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
4497
0.6
0.8
4564
873
780
BHP
CFM
RPM
BHP
CFM
RPM
4562
736
1.58
4253
691
1.29
3893
642
1
1.7
4200
736
1.41
3735
691
1.06
3322
648
0.83
3689
741
1.18
CFM
RPM
BHP
CFM
RPM
BHP
4602
884
2.13
4467
824
1.81
4221
784
1.55
2.06
4170
830
1.68
3677
785
1.29
3498
835
1.34
1
4129
875
1.81
1.2
3558
879
1.49
5
RPM
0.2
0.4
4
CFM
BHP
High-Static Belt-Drive — Horizontal
ESP
(“ W.C.)
Turns Open
0
CFM
RPM
1
BHP
CFM
RPM
2
BHP
CFM
RPM
3
BHP
CFM
RPM
4
BHP
5
0.8
1
4749
940
2.44
4180
885
1.89
1.2
4251
945
2.12
3642
896
1.58
3744
951
1.8
1.4
1.6
DO NOT
OPERATE
4443
1001
2.5
4587
1056
2.82
3971
1006
2.17
3342
1012
1.86
1.8
4760
1105
3.23
4071
1061
2.43
2
4364
1114
2.91
3579
1067
2.05
Notes :
Assume dry coil with filter in place; CFM correction for wet coil = 3%
Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could
require a larger motor. Minimum rated SCFM is 350 per ton.
SS-CPC90-150 www.goodmanmfg.com
9
Product Specifications
Airflow Data — 12½ Tons
Standard Belt Drive --- Down Shot
ESP
(" W.C.)
Turns Open
0
CFM
1
BHP
CFM
2
BHP
0.2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
5378
2.35
4967
1.92
4710
1.59
4512
1.33
4319
1.40
4030
1.13
0.4
5514
2.92
5349
2.56
4750
1.97
4583
1.71
0.6
5204
2.69
4919
2.27
4488
1.81
4258
1.54
0.8
4830
2.42
4649
2.09
4019
1.55
1.0
4497
2.19
4264
1.86
High-Static Belt Drive --- Down Shot
ESP
(" W.C.)
Turns Open
0
CFM
1
BHP
CFM
2
BHP
CFM
3
BHP
0.8
4
5
CFM
BHP
CFM
BHP
CFM
BHP
5978
3.87
5691
3.38
5324
2.81
1.0
5947
4.16
5656
3.58
5376
3.12
4933
2.52
1.2
5708
3.93
5459
3.40
4950
2.79
4441
2.18
4525
2.45
1.4
5776
4.64
5510
4.07
5245
3.48
4844
2.88
1.6
5465
4.30
5199
3.74
4894
3.17
4404
2.54
1.8
5145
3.97
4871
3.41
4495
2.83
2.0
4805
3.63
4565
3.13
4142
2.55
2.2
4429
3.27
4233
2.85
Standard Belt Drive --- Horizontal
ESP
(" W.C.)
Turns Open
0
CFM
1
BHP
CFM
2
BHP
CFM
3
BHP
0.2
4
5
CFM
BHP
CFM
BHP
CFM
BHP
5570
2.27
4935
1.70
4584
1.36
4178
1.19
0.4
5871
3.20
5639
2.77
5307
2.31
4902
1.88
4637
1.55
0.6
5610
3.00
5358
2.57
5051
2.15
4603
1.72
4341
1.41
0.8
5391
2.83
5010
2.33
4799
2.00
4393
1.61
1.0
5078
2.59
4676
2.11
4448
1.79
1.2
4521
2.20
4226
1.83
High-Static Belt Drive --- Horizontal
ESP
(" W.C.)
Turns Open
0
CFM
1
BHP
CFM
2
BHP
CFM
3
BHP
CFM
4
BHP
0.8
1.0
1.2
1.4
5
CFM
BHP
CFM
BHP
5858
3.51
5538
2.97
5894
3.85
5502
3.20
5282
2.78
5780
4.04
5570
3.55
5110
2.88
4869
2.47
4598
2.28
5900
4.49
5501
3.77
5312
3.33
4793
2.64
1.6
5860
4.76
5514
4.08
5257
3.54
4945
3.01
4382
2.34
1.8
5615
4.49
5315
3.88
5020
3.32
4504
2.66
2.0
5529
4.40
4906
3.49
4601
2.96
2.2
4938
3.78
4541
3.15
4222
2.65
Notes
• Assume dry coil with filter in place; CFM correction for wet coil = 3%
• Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Application
• that exceed the above could require a larger motor. Minimum rated SCFM is 350 per ton.
10www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Heat Kit Electrical Data (Blower Only, Heat Mode) — 7½ Tons (A Modles)
Model and
Heat Kit Usage
CPC090XXX3BXXX
EHK3-16
EHK3-30
EHK3-45
Model and
Heat Kit Usage
MCA¹
at 208 / 240V
MOP² (amps)
at 208 / 240V
Actual kW
at 240V
Recommended
Airflow Range
40
48 / 55
87 / 100
121 / 139
50
50 / 60
90 / 100
125 / 150
15
30
43
3000 - 3375 CFM
3000 - 3375 CFM
3000 - 3375 CFM
MCA¹
at 480V
MOP² (amps)
at 480V
Actual kW
at 480V
Recommended
Airflow Range
19
27
50
70
25
30
50
70
15
30
43
3000 - 3375 CFM
3000 - 3375 CFM
3000 - 3375 CFM
MCA¹
at 575V
MOP² (amps)
at 575V
Actual kW
at 575V
Recommended
Airflow Range
14
22
41
57
15
25
45
60
15
30
43
-------
CPC090XXX4BXXX
EHK4-16
EHK4-30
EHK4-45
Model and
Heat Kit Usage
CPC090XXX7BXXX
EHK7-16
EHK7-30
EHK7-45
¹ Minimum Circuit Ampacity
² Maximum Overcurrent Protection device
KW Correction Factors
kW Correction Factor (for 1- & 3-Phase Units)
Supply Voltage
Correction Factor
240
230
220
210
208
1
0.93
0.82
0.78
0.76
kW Correction Factor (for 480V Units)
Supply Voltage
460
440
430
Correction Factor
0.92
0.84
0.8
For other voltage, use voltage² / 480²
kW Correction Factor (for 575V Units)
Minimum Airflow for Electric Heat
Heater Size (kW)
Minimum CFM
15
3,000
Supply Voltage
560
550
540
30
3,000
Correction Factor
0.95
0.91
0.88
43
3,000
Multiply rated kW by correction factor to get actual kW.
SS-CPC90-150 www.goodmanmfg.com
11
Product Specifications
Heat Kit Electrical Data (Blower Only, Heat Mode) — 7½ Tons (B Modles)
Model and
Heat Kit Usage
CPC090XXX3BXXX
EHK3-16
EHK3-30
EHK3-45
Model and
Heat Kit Usage
MCA¹
at 240V
MOP² (amps)
at 240V
Actual kW
at 240V
Recommended
Airflow Range
37
51
97
136
50
60
100
150
15
30
43
3000 - 3375 CFM
3000 - 3375 CFM
3000 - 3375 CFM
MCA¹
at 480V
MOP² (amps)
at 480V
Actual kW
at 480V
Recommended
Airflow Range
18
26
48
68
20
30
50
70
15
30
43
3000 - 3375 CFM
3000 - 3375 CFM
3000 - 3375 CFM
MCA¹
at 575V
MOP² (amps)
at 575V
Actual kW
at 575V
Recommended
Airflow Range
13
22
41
57
15
25
45
60
15
30
43
3000 - 3375 CFM
3000 - 3375 CFM
3000 - 3375 CFM
CPC090XXX4BXXX
EHK4-16
EHK4-30
EHK4-45
Model and
Heat Kit Usage
CPC090XXX7BXXX
EHK7-16
EHK7-30
EHK7-45
¹ Minimum Circuit Ampacity
² Maximum Overcurrent Protection device
KW Correction Factors
kW Correction Factor (for 1- & 3-Phase Units)
Supply Voltage
Correction Factor
240
230
220
210
208
1
0.93
0.82
0.78
0.76
kW Correction Factor (for 480V Units)
Supply Voltage
460
440
430
Correction Factor
0.92
0.84
0.8
For other voltage, use voltage² / 480²
kW Correction Factor (for 575V Units)
Minimum Airflow for Electric Heat
Heater Size (kW)
Minimum CFM
15
3,000
Supply Voltage
560
550
540
30
3,000
Correction Factor
0.95
0.91
0.88
43
3,000
Multiply rated kW by correction factor to get actual kW.
12www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Heat Kit Electrical Data (Blower Only, Heat Mode) — 8½ Tons
Model and
Heat Kit Usage
MCA¹
at 208 / 240V
MOP² (amps)
at 208 / 240V
43
50
CPC102XXX3BXXX
Actual kW
at 240V
Recommended
Airflow Range
(Downshot)
Recommended
Airflow Range
(Horizontal)
EHK3-16
55
60
15
3400 - 3825 CFM
3400 - 3825 CFM
EHK3-30
100
100
30
3400 - 3825 CFM
3400 - 3825 CFM
EHK3-45
139
150
43
3400 - 3825 CFM
3400 - 3825 CFM
MCA¹
at 480V
MOP² (amps)
at 480V
Actual kW
at 480V
Recommended
Airflow Range
(Downshot)
Recommended
Airflow Range
(Horizontal)
CPC102XXX4BXXX
20
25
EHK4-16
27
30
15
3400 - 3825 CFM
3400 - 3825 CFM
EHK4-30
50
50
30
3400 - 3825 CFM
3400 - 3825 CFM
EHK4-45
70
70
43
3400 - 3825 CFM
3400 - 3825 CFM
MCA¹
at 575V
MOP² (amps)
at 575V
Actual kW
at 575V
Recommended
Airflow Range
(Downshot)
Recommended
Airflow Range
(Horizontal)
CPC102XXX7BXXX
17
20
EHK7-16
22
25
15
3400 - 3825 CFM
3400 - 3825 CFM
Model and
Heat Kit Usage
Model and
Heat Kit Usage
EHK7-30
41
45
30
3400 - 3825 CFM
3400 - 3825 CFM
EHK7-45
57
60
43
3400 - 3825 CFM
3400 - 3825 CFM
¹ Minimum Circuit Ampacity
² Maximum Overcurrent Protection device
^ - EHK Heater Kits above require a three-phase power supply
KW Correction Factors
kW Correction Factor (for 1- & 3-Phase Units)
Supply Voltage
Correction Factor
240
230
220
210
208
1
0.93
0.82
0.78
0.76
kW Correction Factor (for 480V Units)
Supply Voltage
460
440
430
Correction Factor
0.92
0.84
0.8
For other voltage, use voltage² / 480²
kW Correction Factor (for 575V Units)
Supply Voltage
560
550
540
Correction Factor
0.95
0.91
0.88
Multiply rated kW by correction factor to get actual kW.
SS-CPC90-150 www.goodmanmfg.com
13
Product Specifications
Heat Kit Electrical Data (Blower Only, Heat Mode) — 10 Tons
Model and
Heat Kit Usage
MCA¹
at 208 / 240V
MOP² (amps)
at 208 / 240V
Actual kW
at 240V
Recommended
Airflow Range
49
48 / 55
87 / 100
121 / 139
60
50 / 60
90 / 100
125 / 150
15
30
43
3500 - 4500 CFM
3500 - 4500 CFM
4000 - 4500 CFM
MCA¹
at 208 / 240V
MOP² (amps)
at 208 / 240V
Actual kW
at 240V
Recommended
Airflow Range
50
49 / 57
88 / 102
122 / 141
60
50 / 60
90 / 110
125 / 150
15
30
43
3500 - 4500 CFM
3500 - 4500 CFM
4000 - 4500 CFM
MCA¹
at 480V
MOP² (amps)
at 480V
Actual kW
at 480V
Recommended
Airflow Range
24
27
50
70
30
30
50
70
15
30
43
3500 - 4500 CFM
3500 - 4500 CFM
4000 - 4500 CFM
MCA¹
at 575V
MOP² (amps)
at 575V
Actual kW
at 575V
Recommended
Airflow Range
17
22
41
57
20
25
45
60
15
30
43
3500 - 4500 CFM
3500 - 4500 CFM
4000 - 4500 CFM
CPC120XXX3BXXX
EHK3-16
EHK3-30
EHK3-45
Model and
Heat Kit Usage
CPC120XXX3HXXX
EHK3-16
EHK3-30
EHK3-45
Model and
Heat Kit Usage
CPC120XXX4BXXX
EHK4-16
EHK4-30
EHK4-45
Model and
Heat Kit Usage
CPC0120XXX7BXXX
EHK7-16
EHK7-30
EHK7-45
¹ Minimum Circuit Ampacity
² Maximum Overcurrent Protection device
kW Correction Factor
kW Correction Factor (for 1- & 3-Phase Units)
Supply Voltage
Correction Factor
240
230
220
210
208
1
0.93
0.82
0.78
0.76
kW Correction Factor for 480V Units
Actual Voltage
460
440
430
Correction Factor
0.92
0.84
0.8
For other voltage use voltage² / 480²
kW Correction Factor for 575V Units
Minimum Airflow for Electric Heat
Heater Size (kW)
Min. CFM
Down-shot
Min. CFM
Horizontal
15
4,000
4,000
Supply Voltage
560
550
540
30
4,000
4,000
Correction Factor
0.95
0.91
0.88
43
4,000
4,000
Multiply rated kW by correction factor to get actual kW
14www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Heat Kit Electrical Data (Blower Only, Heat Mode) — 12½ Tons
Model and
Heat Kit Usage
CPC150***3B***
MCA1 at
208 / 240V
MOP2 (amps)
at 208 / 240V
65
80
Actual kW
at 240V
Recommended
Airflow Range
EHK3-16
65
80
15
4000 - 5600
EHK3-30
102
110
30
4300 - 5600
EHK3-45
141
150
43
4500 - 5600
MCA1 at
208 / 240V
MOP2 (amps)
at 208 / 240V
Actual kW
at 240V
Recommended
Airflow Range
CPC150***4B***
31
40
EHK4-16
31
40
15
4000 - 5600
EHK4-30
51
60
30
4300 - 5600
EHK4-45
71
80
43
4500 - 5600
MCA1 at
208 / 240V
MOP2 (amps)
at 208 / 240V
Actual kW
at 240V
Recommended
Airflow Range
CPC150***7B***
23
30
EHK7-16
24
30
15
4000 - 5600
EHK7-30
43
45
30
4300 - 5600
EHK7-45
59
60
43
4500 - 5600
Model and
Heat Kit Usage
Model and
Heat Kit Usage
¹ Minimum Circuit Ampacity (standard drive)
² Maximum Overcurrent Protection device (standard drive)
KW Correction Factors
kW Correction Factor (for 1- & 3-Phase Units)
Supply Voltage
Correction Factor
240
230
220
210
208
1
0.93
0.82
0.78
0.76
kW Correction Factor (for 480V Units)
Supply Voltage
460
440
430
Correction Factor
0.92
0.84
0.8
For other voltage, use voltage² / 480²
kW Correction Factor (for 575V Units)
Supply Voltage
560
550
540
Correction Factor
0.95
0.91
0.88
Multiply rated kW by correction factor to get actual kW.
SS-CPC90-150 www.goodmanmfg.com
15
89.7
0.83
20
6.24
20.5
236
109
87.1
0.79
21
6.19
20.4
234
108
80.4
0.77
24
6.06
20.0
227
105
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
2400
3000
3375
59
88.2
0.73
18
6.19
20.4
234
108
85.6
0.70
18
6.15
20.3
231
107
79.0
0.67
20
6.01
19.9
224
104
Airflow
MBh
S/T
∆T
kW
3375
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
3000
Amps
Hi PR
Lo PR
MBh
S/T
∆T
2400
kW
Amps
Hi PR
Lo PR
71
-
92.3 100.0 107.3
0.75 0.56 0.36
19
15
11
6.36 6.55 6.75
20.9 21.4 22.0
254 268 280
116 127 135
89.7 97.0 104.1
0.71 0.54 0.35
20
16
11
6.32 6.50 6.70
20.8 21.2 21.8
252 266 277
115 126 134
82.7 89.6 96.1
0.69 0.52 0.33
22
18
12
6.18 6.36 6.55
20.3 20.8 21.4
244 258 269
112 122 130
63
67
91.4 100.2
0.61 0.42
15
12
6.32 6.50
20.8 21.2
252 266
115 126
88.7 97.2
0.58 0.40
16
12
6.27 6.45
20.6 21.1
249 263
114 124
81.9 89.7
0.56 0.39
18
13
6.13 6.31
20.2 20.7
242 255
111 121
87.6
0.86
21
6.69
21.7
265
116
85.1
0.82
21
6.64
21.6
262
114
78.5
0.79
24
6.49
21.2
254
111
59
86.1
0.76
18
6.64
21.6
262
114
83.6
0.72
19
6.59
21.4
260
113
77.2
0.70
21
6.44
21.0
252
110
90.2
0.77
19
6.82
22.1
285
123
87.6
0.74
20
6.77
22.0
282
122
80.8
0.71
22
6.62
21.5
274
118
63
89.3
0.63
15
6.77
22.0
282
122
86.7
0.61
16
6.72
21.8
279
120
80.0
0.58
18
6.57
21.4
271
117
67
97.8
0.44
12
6.98
22.5
298
133
95.0
0.42
12
6.92
22.4
295
132
87.7
0.40
14
6.76
21.9
286
128
71
-
59
84.1
0.78
18
7.03
23.0
298
119
81.6
0.74
19
6.98
22.8
295
118
75.4
0.72
21
6.81
22.3
286
114
97.6 104.8 85.5
0.58 0.38 0.89
16
11
21
7.03 7.25 7.08
22.7 23.3 23.1
301 314 301
134 143 120
94.8 101.7 83.0
0.56 0.36 0.84
16
11
21
6.98 7.19 7.03
22.5 23.1 23.0
298 311 298
133 141 119
87.5 93.9 76.6
0.54 0.35 0.81
18
12
24
6.82 7.02 6.87
22.0 22.7 22.5
289 302 289
129 137 115
75
IDB = Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65
88.0
0.79
19
7.23
23.5
324
128
85.5
0.76
20
7.17
23.4
321
126
78.9
0.73
22
7.01
22.9
311
123
85.9
0.82
19
7.59
24.8
369
134
83.4
0.78
20.0
7.53
24.6
366
133
77.0
0.75
22
7.35
24.1
355
129
93.0
0.62
16
7.83
25.4
390
146
90.3
0.59
16
7.76
25.2
386
145
83.3
0.57
18
7.58
24.7
375
141
99.8
0.40
11
8.07
26.2
407
156
96.9
0.38
11
8.01
26.0
403
154
89.4
0.37
13
7.82
25.4
391
150
79.3
0.95
20
7.73
25.5
386
132
77.0
0.90
21
7.67
25.3
382
131
71.0
0.87
24
7.49
24.8
371
127
59
77.9
0.83
18
7.67
25.3
382
131
75.7
0.80
18
7.61
25.1
378
130
69.8
0.77
21
7.43
24.6
367
126
Shaded area reflects ACCA (TVA) conditions
95.3 102.3 83.4
0.60 0.39 0.91
16
11
21
7.45 7.69 7.43
24.1 24.8 24.3
342 357 343
139 149 126
92.5 99.3 81.0
0.57 0.37 0.87
16
11
22
7.39 7.63 7.38
24.0 24.7 24.1
339 354 340
138 147 125
85.4 91.7 74.8
0.55 0.35 0.84
18
12
24
7.22 7.45 7.20
23.5 24.1 23.6
329 343 330
134 143 121
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
71
87.2 95.5
82.0 85.0 93.2
0.65 0.45
0.80 0.67 0.47
15
12
18
16
12
7.17 7.39
7.37 7.53 7.76
23.4 24.0
24.1 24.6 25.2
321 339
340 366 386
126 138
125 133 145
84.6 92.7
79.7 82.6 90.5
0.62 0.43
0.77 0.64 0.44
16
12
19
16
12
7.12 7.34
7.32 7.47 7.70
23.2 23.8
24.0 24.4 25.0
318 336
336 362 382
125 137
124 132 144
78.1 85.6
73.5 76.2 83.5
0.60 0.41
0.74 0.62 0.43
18
14
21
18
14
6.95 7.16
7.15 7.29 7.52
22.7 23.3
23.5 23.9 24.5
308 326
326 351 371
121 133
120 128 139
81.6
0.85
19
7.89
26.0
415
141
79.2
0.81
20
7.83
25.8
411
139
73.1
0.78
22
7.65
25.3
399
135
63
80.8
0.70
15
7.83
25.8
411
139
78.4
0.66
16
7.77
25.6
407
138
72.4
0.64
18
7.58
25.1
395
134
88.3
0.64
15
8.14
26.7
439
154
85.8
0.61
16
8.08
26.5
434
152
79.2
0.59
18
7.88
25.9
421
147
67
88.5
0.48
12
8.08
26.5
434
152
85.9
0.46
12
8.01
26.3
430
150
79.3
0.44
13
7.82
25.7
417
146
105
73.4
0.96
19
7.99
26.7
427
137
71.3
0.91
20
7.92
26.5
422
135
65.8
0.88
22
7.73
25.9
410
131
59
72.2
0.84
17
7.92
26.5
422
135
70.1
0.80
17
7.86
26.3
418
134
64.7
0.77
19
7.67
25.7
406
130
75.6
0.86
18
8.16
27.2
459
145
73.4
0.82
18
8.09
27.0
454
144
67.7
0.79
20
7.90
26.4
441
140
63
74.8
0.70
14
8.09
27.0
454
144
72.6
0.67
15
8.03
26.8
450
143
67.1
0.65
17
7.83
26.2
436
138
81.8
0.65
14
8.42
27.9
485
159
79.4
0.62
15
8.35
27.7
480
157
73.3
0.60
17
8.15
27.1
466
153
67
82.0
0.49
11
8.35
27.7
480
157
79.6
0.46
11
8.28
27.5
475
156
73.5
0.45
13
8.08
26.9
461
151
87.8
0.42
10
8.69
28.8
506
169
85.3
0.40
10
8.62
28.6
501
167
78.7
0.38
12
8.41
27.9
486
162
71
-
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
94.8
0.41
11
8.40
27.5
458
163
92.0
0.39
11
8.34
27.3
453
162
85.0
0.38
12
8.13
26.7
439
157
71
-
115
Product Specifications
Expanded Cooling Data — 7½ Tons (A Models)
16www.goodmanmfg.com
SS-CPC90-150
SS-CPC90-150 www.goodmanmfg.com
92.9
0.96
24
6.33
20.8
241
112
90.2
0.91
25
6.29
20.7
238
110
83.2
0.88
28
6.15
20.3
231
107
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
2400
3000
3375
59
91.3
0.91
23
6.29
20.7
238
110
88.6
0.87
24
6.24
20.5
236
109
81.8
0.84
26
6.10
20.1
229
106
Airflow
MBh
S/T
∆T
kW
3375
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
3000
Amps
Hi PR
Lo PR
MBh
S/T
∆T
2400
kW
Amps
Hi PR
Lo PR
94.7
0.92
24
6.46
21.2
259
119
91.9
0.88
25
6.41
21.0
257
118
84.8
0.85
28
6.27
20.6
249
114
63
93.3
0.86
22
6.41
21.0
257
118
90.6
0.82
23
6.36
20.9
254
116
83.6
0.79
25
6.22
20.5
246
113
99.2 105.8 90.7
0.83 0.68 0.99
23
20
25
6.65 6.85 6.79
21.7 22.3 22.0
274 285 270
130 138 118
96.3 102.7 88.1
0.80 0.65 0.95
23
20
26
6.60 6.80 6.74
21.5 22.1 21.9
271 283 268
128 137 117
88.9 94.8 81.3
0.77 0.62 0.91
26
23
28
6.45 6.65 6.59
21.1 21.7 21.4
263 274 260
124 133 113
67
71
59
99.7 106.5 89.2
0.70 0.52 0.95
19
15
23
6.60 6.80 6.74
21.5 22.1 21.9
271 283 268
128 137 117
96.8 103.4 86.6
0.67 0.50 0.90
20
16
24
6.55 6.75 6.69
21.4 22.0 21.7
268 280 265
127 135 116
89.3 95.5 79.9
0.64 0.48 0.87
22
18
27
6.40 6.60 6.54
21.0 21.5 21.3
260 271 257
123 131 112
92.5
0.96
24
6.93
22.4
291
125
89.8
0.91
25
6.88
22.3
288
124
82.9
0.88
28
6.72
21.8
279
120
63
91.1
0.89
22
6.88
22.3
288
124
88.5
0.85
23
6.82
22.1
285
123
81.6
0.82
26
6.67
21.7
277
119
75
IDB = Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65
96.8 103.3 88.6
0.86 0.70 1.00
23
20
24
7.14 7.36 7.19
23.0 23.6 23.4
307 320 307
137 146 122
94.0 100.3 86.0
0.82 0.67 0.97
24
21
26
7.08 7.30 7.14
22.8 23.5 23.3
304 317 304
136 144 121
86.8 92.6 79.4
0.80 0.65 0.94
26
23
28
6.92 7.13 6.97
22.3 23.0 22.8
295 308 295
131 140 118
67
71
59
97.3 104.1 87.0
0.72 0.54 1.00
19
15
24
7.08 7.30 7.14
22.8 23.5 23.3
304 317 304
136 144 121
94.5 101.0 84.5
0.69 0.52 0.93
20
16
24
7.03 7.25 7.08
22.7 23.3 23.1
301 314 301
134 143 120
87.2 93.2 78.0
0.67 0.50 0.89
22
18
27
6.87 7.08 6.92
22.2 22.8 22.6
292 305 292
130 139 116
90.3
0.98
24
7.34
23.9
331
130
87.6
0.94
25
7.29
23.7
328
129
80.9
0.90
28
7.12
23.2
318
125
88.1
1.00
24
7.71
25.1
377
137
85.5
0.97
25
7.65
24.9
373
136
78.9
0.93
28
7.47
24.4
362
131
92.2
0.92
23
7.95
25.8
398
149
89.6
0.87
24
7.89
25.6
394
148
82.7
0.84
27
7.70
25.0
382
144
98.4
0.74
20
8.20
26.5
415
159
95.5
0.71
21
8.14
26.3
411
158
88.2
0.68
23
7.94
25.8
399
153
71
99.1
0.57
15
8.14
26.3
411
158
96.2
0.55
16
8.07
26.2
407
156
88.8
0.53
18
7.88
25.6
395
151
82.1
1.00
22
7.85
25.9
394
135
79.7
1.00
24
7.79
25.7
390
134
73.6
1.00
28
7.61
25.1
378
130
59
80.7
1.00
22
7.79
25.7
390
134
78.3
0.99
24
7.73
25.5
386
132
72.3
0.96
27
7.55
25.0
375
128
Shaded area reflects AHRI (TVA) conditions
94.5 100.9 86.4
0.89 0.72 1.00
23
20
24
7.57 7.81 7.55
24.5 25.2 24.7
349 364 350
142 152 129
91.8 97.9 83.9
0.85 0.69 1.00
24
21
26
7.51 7.75 7.49
24.3 25.0 24.5
346 361 347
141 150 127
84.7 90.4 77.4
0.82 0.66 0.97
26
23
29
7.33 7.56 7.32
23.8 24.5 24.0
335 350 336
137 146 124
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
88.9 95.0 101.6 84.9 86.8 92.7
0.91 0.74 0.55 1.00 0.94 0.77
22
19
15
23
22
19
7.29 7.51 7.75 7.49 7.65 7.89
23.7 24.3 25.0 24.5 24.9 25.6
328 346 361 347 373 394
129 141 150 127 136 148
86.3 92.3 98.6 82.4 84.2 90.0
0.87 0.71 0.53 0.96 0.90 0.73
23
20
16
24
23 20.0
7.23 7.45 7.69 7.43 7.59 7.83
23.5 24.1 24.8 24.3 24.8 25.4
324 342 357 343 369 390
128 139 149 126 134 147
79.7 85.1 91.0 76.1 77.8 83.1
0.84 0.68 0.51 0.92 0.86 0.70
26
22
18
27
26
22
7.06 7.28 7.50 7.26 7.41 7.64
23.1 23.6 24.3 23.8 24.2 24.9
315 332 346 333 358 378
124 135 144 122 130 142
83.7
1.00
23
8.02
26.4
424
143
81.2
1.00
25
7.96
26.2
420
142
75.0
0.97
28
7.77
25.6
407
138
63
82.4
1.00
22
7.96
26.2
420
142
80.0
0.93
23
7.89
26.0
415
141
73.9
0.90
25
7.71
25.4
403
136
87.6
0.95
23
8.27
27.1
448
157
85.1
0.91
24
8.21
26.9
443
155
78.5
0.87
26
8.01
26.3
430
150
67
88.1
0.79
19
8.21
26.9
443
155
85.5
0.76
20
8.14
26.7
439
154
78.9
0.73
22
7.95
26.1
426
149
105
76.0
1.00
21
8.12
27.1
435
139
73.8
1.00
23
8.05
26.9
431
138
68.1
1.00
26
7.86
26.3
418
134
59
74.7
1.00
20
8.05
26.9
431
138
72.5
1.00
22
7.99
26.7
427
137
67.0
0.97
25
7.80
26.1
414
133
77.5
1.00
21
8.29
27.6
468
148
75.2
1.00
23
8.22
27.4
464
147
69.4
0.98
26
8.02
26.8
450
143
63
76.4
1.00
21
8.22
27.4
464
147
74.1
0.94
21
8.16
27.2
459
145
68.4
0.91
24
7.96
26.6
445
141
71
87.2
0.60
14
8.76
29.0
511
171
84.7
0.57
15
8.69
28.8
506
169
78.1
0.55
16
8.48
28.1
490
164
81.2 86.6
0.96 0.78
21
18
8.55 8.83
28.4 29.2
495 516
162 173
78.8 84.1
0.91 0.74
22
19
8.48 8.76
28.1 29.0
490 511
160 171
72.7 77.6
0.88 0.71
25
21
8.28 8.55
27.5 28.4
475 495
156 166
67
81.6
0.80
18
8.48
28.1
490
160
79.2
0.76
19
8.42
27.9
485
159
73.1
0.74
21
8.21
27.3
470
154
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
93.5
0.77
20
8.54
27.9
467
167
90.8
0.74
20
8.47
27.7
462
165
83.8
0.71
23
8.27
27.1
448
160
71
94.1
0.59
15
8.47
27.7
462
165
91.4
0.57
16
8.40
27.5
458
164
84.4
0.55
18
8.20
26.9
444
159
115
Product Specifications
Expanded Cooling Data — 7½ Tons (A Models cont.)
17
87.7
0.82
20
6.31
21.2
236
104
85.1
0.78
20
6.27
21.1
234
103
78.6
0.76
23
6.14
20.7
227
100
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
2400
3000
3375
59
86.2
0.72
17
6.27
21.1
234
103
83.7
0.69
18
6.23
21.0
231
102
77.3
0.67
20
6.10
20.6
224
99
Airflow
MBh
S/T
∆T
kW
3375
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
3000
Amps
Hi PR
Lo PR
MBh
S/T
∆T
2400
kW
Amps
Hi PR
Lo PR
90.3
0.74
18
6.43
21.6
254
111
87.7
0.70
19
6.39
21.4
252
110
80.9
0.68
21
6.25
21.1
244
107
63
89.4
0.60
15
6.39
21.4
252
110
86.8
0.58
15
6.34
21.3
249
109
80.1
0.56
17
6.21
20.9
242
106
71
-
59
84.2
0.75
17
6.69
22.2
262
109
81.8
0.71
18
6.65
22.1
260
108
75.5
0.69
20
6.50
21.7
252
105
97.7 104.9 85.7
0.56 0.36 0.85
15
10
20
6.61 6.80 6.74
22.1 22.6 22.4
268 280 265
121 129 110
94.9 101.8 83.2
0.53 0.34 0.81
15
11
21
6.57 6.75 6.69
21.9 22.5 22.2
266 277 262
120 128 109
87.6 94.0 76.8
0.51 0.33 0.78
17
12
23
6.42 6.61 6.55
21.5 22.1 21.8
258 269 254
117 124 106
67
97.9
0.42
11
6.56
21.9
266
120
95.1
0.40
12
6.52
21.8
263
119
87.8
0.38
13
6.38
21.4
255
115
88.2
0.76
18
6.87
22.8
285
117
85.6
0.73
19
6.82
22.6
282
116
79.0
0.70
21
6.68
22.2
274
113
63
87.3
0.63
15
6.82
22.6
282
116
84.8
0.60
16
6.77
22.5
279
115
78.2
0.58
17
6.63
22.1
271
112
75
IDB = Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65
71
-
59
82.2
0.77
17
7.07
23.6
298
114
79.8
0.73
18
7.02
23.4
295
112
73.7
0.71
20
6.86
23.0
286
109
95.5 102.5 83.6
0.58 0.37 0.87
15
10
20
7.07 7.28 7.12
23.3 23.9 23.7
301 314 301
128 137 115
92.7 99.5 81.2
0.55 0.35 0.83
16
11
21
7.02 7.22 7.07
23.1 23.7 23.6
298 311 298
127 135 114
85.5 91.8 74.9
0.53 0.34 0.80
17
12
23
6.86 7.06 6.91
22.7 23.3 23.1
289 302 289
123 131 110
67
95.6
0.43
11
7.02
23.1
298
127
92.9
0.41
12
6.97
23.0
295
126
85.7
0.40
13
6.81
22.5
286
122
86.1
0.78
18
7.26
24.1
324
122
83.6
0.75
19
7.21
24.0
321
121
77.1
0.72
21
7.05
23.5
311
117
84.0
0.81
18
7.60
25.3
369
128
81.5
0.77
19
7.55
25.1
366
127
75.3
0.74
21
7.38
24.6
355
123
90.9
0.61
15
7.83
25.9
390
140
88.3
0.58
16
7.77
25.7
386
139
81.5
0.56
18
7.59
25.2
375
134
97.6
0.39
10
8.07
26.6
407
149
94.7
0.37
11
8.01
26.4
403
148
87.4
0.36
12
7.82
25.9
391
143
77.5
0.94
20
7.74
26.0
386
126
75.2
0.89
21
7.68
25.8
382
125
69.4
0.86
23
7.51
25.3
371
121
59
76.2
0.82
17
7.68
25.8
382
125
74.0
0.79
18
7.62
25.7
378
124
68.3
0.76
20
7.45
25.1
367
120
Shaded area reflects ACCA (TVA) conditions
93.2 100.0 81.6
0.59 0.38 0.90
15
10
20
7.47 7.70 7.46
24.7 25.3 24.9
342 357 343
133 142 121
90.5 97.1 79.2
0.56 0.36 0.86
16
11
21
7.42 7.64 7.40
24.5 25.2 24.7
339 354 340
132 141 119
83.5 89.6 73.1
0.54 0.35 0.83
17
12
23
7.25 7.47 7.23
24.0 24.7 24.2
329 343 330
128 136 116
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
71
85.2 93.4
80.2 83.1 91.1
0.64 0.44
0.79 0.66 0.46
15
11
17
15
11
7.21 7.42
7.40 7.55 7.77
24.0 24.5
24.7 25.1 25.7
321 339
340 366 386
121 132
119 127 139
82.7 90.7
77.9 80.7 88.4
0.61 0.42
0.76 0.63 0.44
16
12
18
16
12
7.15 7.36
7.34 7.49 7.71
23.8 24.4
24.5 25.0 25.6
318 336
336 362 382
120 131
118 126 137
76.4 83.7
71.9 74.5 81.6
0.59 0.41
0.73 0.61 0.42
17
13
20
17
13
7.00 7.20
7.18 7.32 7.54
23.3 23.9
24.0 24.5 25.0
308 326
326 351 371
116 127
115 122 133
79.8
0.84
18
7.90
26.5
415
134
77.5
0.80
19
7.84
26.3
411
133
71.5
0.77
21
7.66
25.8
399
129
63
79.0
0.69
15
7.83
26.3
411
133
76.7
0.66
15
7.78
26.1
407
132
70.8
0.63
17
7.60
25.6
395
128
86.4
0.63
15
8.13
27.1
439
147
83.9
0.60
16
8.07
26.9
434
145
77.4
0.58
17
7.89
26.4
421
141
67
86.5
0.48
11
8.07
26.9
434
145
84.0
0.45
12
8.01
26.7
430
144
77.5
0.44
13
7.82
26.2
417
139
105
71.8
0.94
18
7.98
27.1
427
131
69.7
0.90
19
7.92
26.9
422
129
64.3
0.87
21
7.74
26.4
410
125
59
70.6
0.83
16
7.92
26.9
422
129
68.5
0.79
17
7.86
26.8
418
128
63.3
0.76
19
7.68
26.2
406
124
73.9
0.84
17
8.15
27.6
459
139
71.8
0.81
18
8.08
27.4
454
138
66.2
0.78
20
7.90
26.9
441
133
63
73.2
0.69
14
8.08
27.4
454
138
71.0
0.66
14
8.02
27.2
450
136
65.6
0.64
16
7.84
26.7
436
132
80.0
0.64
14
8.39
28.3
485
152
77.7
0.61
15
8.33
28.1
480
150
71.7
0.59
16
8.14
27.5
466
146
67
80.2
0.48
10
8.33
28.1
480
150
77.8
0.46
11
8.26
27.9
475
149
71.8
0.44
12
8.07
27.3
461
144
85.9
0.41
10
8.65
29.1
506
162
83.4
0.39
10
8.59
28.9
501
160
76.9
0.38
11
8.39
28.3
486
155
71
-
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
92.7
0.41
10
8.38
27.9
458
156
90.0
0.39
11
8.32
27.7
453
155
83.1
0.37
12
8.12
27.1
439
150
71
-
115
Product Specifications
Expanded Cooling Data — 7½ Tons (B Models)
18www.goodmanmfg.com
SS-CPC90-150
SS-CPC90-150 www.goodmanmfg.com
90.8
0.95
23
6.40
21.5
241
107
88.2
0.90
24
6.36
21.4
238
106
81.4
0.87
27
6.22
21.0
231
102
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
2400
3000
3375
59
89.3
0.90
22
6.36
21.4
238
106
86.7
0.86
23
6.31
21.2
236
105
80.0
0.83
25
6.18
20.9
229
101
Airflow
MBh
S/T
∆T
kW
3375
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
3000
Amps
Hi PR
Lo PR
MBh
S/T
∆T
2400
kW
Amps
Hi PR
Lo PR
92.6
0.91
23
6.52
21.8
259
113
89.9
0.87
24
6.48
21.7
257
112
83.0
0.84
27
6.34
21.3
249
109
63
91.2
0.85
21
6.48
21.7
257
112
88.5
0.81
22
6.43
21.6
254
111
81.7
0.78
24
6.30
21.2
246
108
97.0 103.4 88.7
0.82 0.67 0.98
22
19
24
6.71 6.90 6.84
22.3 22.9 22.7
274 285 270
124 132 113
94.1 100.4 86.1
0.79 0.64 0.93
23
20
25
6.66 6.85 6.79
22.2 22.8 22.5
271 283 268
123 131 112
86.9 92.7 79.5
0.76 0.61 0.90
25
22
27
6.52 6.70 6.64
21.8 22.3 22.1
263 274 260
119 127 108
67
71
59
97.4 104.2 87.2
0.69 0.51 0.93
18
15
22
6.66 6.85 6.79
22.2 22.8 22.5
271 283 268
123 131 112
94.6 101.1 84.6
0.66 0.49 0.89
19
15
23
6.61 6.80 6.74
22.1 22.6 22.4
268 280 265
121 129 110
87.3 93.3 78.1
0.63 0.47 0.86
21
17
26
6.47 6.65 6.60
21.6 22.2 22.0
260 271 257
118 125 107
90.4
0.95
23
6.97
23.0
291
120
87.8
0.90
24
6.92
22.9
288
119
81.0
0.87
27
6.77
22.5
279
115
63
89.1
0.88
21
6.92
22.9
288
119
86.5
0.84
22
6.87
22.8
285
117
79.8
0.81
25
6.72
22.3
277
114
75
IDB = Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65
94.7 101.0 86.6
0.85 0.69 1.00
22
19
24
7.17 7.39 7.23
23.6 24.2 24.0
307 320 307
131 139 117
91.9 98.1 84.1
0.81 0.66 0.96
23
20
25
7.12 7.33 7.17
23.4 24.0 23.9
304 317 304
130 138 116
84.9 90.5 77.6
0.78 0.64 0.92
25
22
27
6.96 7.17 7.02
23.0 23.6 23.4
295 308 295
126 134 112
67
71
59
95.2 101.7 85.1
0.71 0.53 0.96
18
15
22
7.12 7.33 7.17
23.4 24.0 23.9
304 317 304
130 138 116
92.4 98.8 82.6
0.68 0.51 0.91
19
15
23
7.07 7.28 7.12
23.3 23.9 23.7
301 314 301
128 137 115
85.3 91.2 76.3
0.66 0.49 0.88
21
17
26
6.91 7.12 6.96
22.8 23.4 23.3
292 305 292
124 132 111
88.3
0.97
23
7.37
24.4
331
125
85.7
0.92
24
7.32
24.3
328
123
79.1
0.89
27
7.15
23.8
318
120
92.4
0.87
22
7.59
25.0
349
136
89.7
0.83
23
7.53
24.8
346
135
82.8
0.80
26
7.36
24.4
335
131
84.5
1.00
23
7.57
25.2
350
123
82.0
0.99
25
7.51
25.0
347
122
75.7
0.95
28
7.34
24.5
336
118
86.1
1.00
23
7.72
25.6
377
131
83.6
0.95
24
7.66
25.5
373
130
77.2
0.92
27
7.49
25.0
362
126
90.2
0.90
22
7.95
26.2
398
143
87.6
0.86
23
7.89
26.1
394
141
80.8
0.83
26
7.71
25.5
382
137
96.2
0.73
19
8.19
27.0
415
152
93.4
0.70
20
8.13
26.8
411
151
86.2
0.67
22
7.94
26.2
399
146
71
96.9
0.56
15
8.13
26.8
411
151
94.1
0.54
16
8.07
26.6
407
149
86.8
0.52
17
7.88
26.1
395
145
80.3
1.00
22
7.86
26.4
394
129
77.9
1.00
24
7.80
26.2
390
128
71.9
0.99
27
7.62
25.6
378
124
59
78.9
1.00
21
7.80
26.2
390
128
76.6
0.98
23
7.74
26.0
386
126
70.7
0.94
26
7.56
25.5
375
123
Shaded area reflects AHRI (TVA) conditions
98.6
0.71
19
7.81
25.7
364
145
95.7
0.68
20
7.76
25.5
361
143
88.4
0.65
22
7.58
25.0
350
139
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
87.0 92.9 99.3 83.0 84.8 90.6
0.90 0.73 0.55 1.00 0.93 0.75
21
19
15
23
21
19
7.32 7.53 7.76 7.51 7.66 7.89
24.3 24.8 25.5 25.0 25.5 26.1
328 346 361 347 373 394
123 135 143 122 130 141
84.4 90.2 96.4 80.6 82.4 88.0
0.86 0.70 0.52 0.94 0.88 0.72
22
19
15
23
22
19
7.26 7.47 7.70 7.46 7.60 7.83
24.1 24.7 25.3 24.9 25.3 25.9
324 342 357 343 369 390
122 133 142 121 128 140
77.9 83.3 89.0 74.4 76.0 81.2
0.83 0.67 0.50 0.91 0.85 0.69
25
21
17
26
25
22
7.10 7.31 7.52 7.29 7.43 7.65
23.6 24.2 24.8 24.4 24.8 25.4
315 332 346 333 358 378
118 129 138 117 124 136
81.8
1.00
22
8.02
26.8
424
137
79.4
0.99
24
7.96
26.6
420
136
73.3
0.95
27
7.77
26.1
407
132
63
80.6
0.96
21
7.96
26.6
420
136
78.2
0.92
22
7.90
26.5
415
134
72.2
0.89
24
7.72
25.9
403
130
85.7
0.94
22
8.26
27.5
448
150
83.2
0.89
23
8.20
27.3
443
148
76.8
0.86
25
8.01
26.7
430
144
67
86.1
0.78
18
8.20
27.3
443
148
83.6
0.75
19
8.13
27.1
439
147
77.2
0.72
21
7.95
26.6
426
142
105
74.3
1.00
20
8.11
27.5
435
133
72.2
1.00
22
8.05
27.3
431
132
66.6
1.00
25
7.86
26.8
418
128
59
73.1
1.00
20
8.05
27.3
431
132
70.9
0.99
21
7.98
27.1
427
131
65.5
0.95
24
7.80
26.6
414
127
75.8
1.00
21
8.27
28.0
468
142
73.6
1.00
23
8.21
27.8
464
140
67.9
0.96
25
8.02
27.2
450
136
63
74.7
0.97
20
8.21
27.8
464
140
72.5
0.93
21
8.15
27.6
459
139
66.9
0.89
23
7.96
27.1
445
135
71
85.3
0.59
14
8.72
29.3
511
163
82.8
0.56
14
8.65
29.1
506
162
76.4
0.54
16
8.45
28.5
490
157
79.4 84.7
0.94 0.77
20
18
8.53 8.79
28.7 29.5
495 516
155 165
77.1 82.2
0.90 0.73
21
18
8.46 8.72
28.5 29.3
490 511
153 163
71.1 75.9
0.87 0.71
24
20
8.26 8.52
27.9 28.7
475 495
149 158
67
79.8
0.79
17
8.46
28.5
490
153
77.4
0.75
18
8.39
28.3
485
152
71.5
0.73
20
8.20
27.7
470
147
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
91.4
0.76
19
8.51
28.3
467
159
88.7
0.73
20
8.45
28.1
462
158
81.9
0.70
22
8.25
27.5
448
153
71
92.0
0.59
15
8.45
28.1
462
158
89.4
0.56
15
8.38
27.9
458
156
82.5
0.54
17
8.19
27.3
444
152
115
Product Specifications
Expanded Cooling Data — 7½ Tons (B Models cont.)
19
89.6
0.64
19
8.90
235
99
MBh
S/T
∆T
kW
HI PR
LO PR
MBh 101.6 104.7
S/T
0.79 0.71
∆T
20
19
kW
8.90 8.90
HI PR 247 266
LO PR 105 111
3200
2800
3600
91.1
0.73
22
8.90
237
101
MBh
S/T
∆T
kW
HI PR
LO PR
3200
2800
87.5
0.66
19
8.90
264
105
94.8
0.69
19
8.90
272
108
90.7
0.55
16
8.90
284
112
99.3
0.38
12
8.90
299
122
98.2 107.6
0.57 0.40
16
12
8.90 8.90
292 309
115 126
59
63
67
97.6 101.2 110.9
0.72 0.60 0.42
18
16
12
8.90 8.90 8.90
274 295 312
109 116 127
89.0
0.75
22
8.90
266
106
118.0 96.4
0.33 0.78
11
22
8.90 8.90
290 274
128 109
85.4
0.68
19
8.90
300
109
92.5
0.70
19
8.90
309
113
59
95.3
0.74
18
8.90
312
114
118.8 96.9
0.36 0.84
11
21
8.90 8.90
329 315
137 115
-
-
71
-
91.6
0.67
20
8.90
286
113
99.1 106.4 86.8
0.51 0.33 0.77
17
11
22
8.90 8.90 8.90
303 316 303
123 131 110
99.2 107.4 115.3 94.1
0.70 0.53 0.34 0.80
20
16
11
22
8.90 8.90 8.90 8.90
295 312 325 312
116 127 135 114
121.6 99.3 102.2 110.6
0.34 0.82 0.73 0.55
11
21
19
16
8.90 8.90 8.90 8.90
293 277 298 315
129 111 118 128
-
-
71
-
93.8 101.5 108.9
0.65 0.49 0.32
20
16
11
8.90 8.90 8.90
255 270 281
107 117 124
98.7 101.6 110.0
0.75 0.67 0.51
21
20
16
8.90 8.90 8.90
245 263 278
104 110 120
MBh
S/T
∆T
kW
HI PR
LO PR
113.3
0.53
15
8.90
281
122
92.8 101.7
0.53 0.37
16
12
8.90 8.90
253 267
106 116
97.0 100.6 110.2
0.66 0.55 0.38
18
16
12
8.90 8.90 8.90
242 261 275
103 109 119
67
113.5
0.40
12
8.90
278
120
MBh
S/T
∆T
kW
HI PR
LO PR
Airflow
59
63
MBh 100.0 103.6
S/T
0.69 0.58
∆T
18
15
3600
kW
8.90 8.90
HI PR 245 263
LO PR 104 110
75
IDB = Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65
97.0
0.39
12
8.90
341
127
-
83.3
0.70
19
8.90
341
115
90.3
0.73
19
8.90
352
118
89.4
0.69
20
8.90
326
117
94.6
0.41
13
8.90
388
133
-
79.2
0.73
19
8.90
384
120
85.8
0.75
19
8.90
396
124
87.2
0.71
20
8.90
371
123
94.4 101.3 80.5
0.54 0.35 0.83
17
12
22
8.90 8.90 8.90
392 409 388
135 143 121
94.5 102.3 109.8 87.2
0.74 0.56 0.36 0.86
20
16
11
21
8.90 8.90 8.90 8.90
383 404 421 400
127 139 148 125
97.4 105.4 113.1 89.8
0.77 0.59 0.38 0.90
19
16
11
21
8.90 8.90 8.90 8.90
386 408 426 404
128 140 149 126
86.4
0.58
17
8.90
367
122
93.6 102.5
0.61 0.42
16
12
8.90 8.90
379 400
126 137
59
88.3
0.79
18
8.90
400
125
Shaded area reflects ACCA (TVA) conditions
96.8 103.9 84.7
0.52 0.34 0.80
17
11
22
8.90 8.90 8.90
344 359 345
128 137 116
96.9 104.9 112.5 91.8
0.72 0.54 0.35 0.83
20
16
11
22
8.90 8.90 8.90 8.90
336 355 370 355
121 132 141 120
99.8 108.0 115.9 94.6
0.75 0.57 0.37 0.87
19
16
11
21
8.90 8.90 8.90 8.90
339 358 374 359
122 133 142 121
88.5
0.57
16
8.90
323
116
95.9 105.1
0.59 0.41
16
12
8.90 8.90
332 351
120 131
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
71
98.8 108.2
93.0 96.4 105.6
0.62 0.43
0.76 0.64 0.44
16
12
18
16
12
8.90 8.90
8.90 8.90 8.90
336 355
355 382 404
121 132
119 127 139
-
89.9
0.42
12
8.90
436
140
97.4
0.44
12
8.90
450
144
-
-
71
-
73.3
0.73
18
8.90
424
124
79.4
0.76
17
8.90
437
128
59
81.8
0.80
17
8.90
442
130
82.9
0.74
20
8.90
417
129
89.8
0.77
20
8.90
430
133
89.7
0.56
16
8.90
441
141
74.6
0.83
20
8.90
429
126
76.8
0.74
19
8.90
461
134
83.2
0.77
18
8.90
476
138
85.7
0.81
18
8.90
480
139
76.0
0.61
15
8.90
457
132
82.3
0.63
15
8.90
471
136
63
84.8
0.67
14
8.90
475
138
83.1
0.56
15
8.90
487
146
90.0
0.58
15
8.90
502
150
92.7
0.61
15
8.90
507
152
83.3
0.42
12
8.90
482
144
90.2
0.44
11
8.90
497
149
67
92.9
0.46
11
8.90
502
150
115
89.2
0.36
11
8.90
508
155
96.6
0.38
10
8.90
524
160
99.5
0.39
10
8.90
529
162
-
-
71
-
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
96.3
0.36
11
8.90
460
150
97.2 104.3 80.8
0.58 0.37 0.86
16
11
20
8.90 8.90 8.90
454 474 442
145 155 130
92.5 100.1 107.4 83.2
0.80 0.61 0.39 0.91
19
16
11
19
8.90 8.90 8.90 8.90
435 459 479 446
135 147 156 131
82.0
0.61
16
8.90
413
128
88.9
0.63
16
8.90
426
132
63
67
91.6 100.3
0.66 0.46
15
12
8.90 8.90
430 454
133 145
105
Product Specifications
Expanded Cooling Data — 8½ Tons
20www.goodmanmfg.com
SS-CPC90-150
SS-CPC90-150 www.goodmanmfg.com
MBh
S/T
∆T
kW
HI PR
LO PR
3200
2800
90.5
0.82
25
8.90
269
107
92.5
0.77
23
8.90
289
114
92.1
0.86
26
8.90
272
108
93.9
0.83
26
8.90
292
115
114.5 95.8
0.49 0.88
16
24
8.90 8.90
329 315
137 115
71
59
117.9 98.6
0.51 0.92
15
23
8.90 8.90
332 318
138 116
109.8
0.82
23
8.90
321
131
90.3
0.79
24
8.90
329
119
98.4 104.9 89.9
0.75 0.61 0.89
24
21
26
8.90 8.90 8.90
309 322 309
126 134 113
113.7 97.4
0.63 0.92
21
26
8.90 8.90
332 318
138 116
114.3 97.9
0.68 0.99
20
25
8.90 8.90
381 366
145 123
91.7
0.86
26
8.90
332
120
94.1 100.6 81.9
0.67 0.50 0.91
21
16
24
8.90 8.90 8.90
396 413 392
136 145 123
89.4
0.88
26
8.90
379
126
93.7
0.80
25
8.90
400
137
99.9
0.65
21
8.90
417
146
83.4
0.95
26
8.90
396
124
96.9 101.5 108.3 90.3
0.92 0.83 0.67 0.98
25
24
21
26
8.90 8.90 8.90 8.90
390 412 430 408
130 142 151 128
99.8 104.5 111.5 93.0
0.96 0.87 0.70 1.00
24
23
20
24
8.90 8.90 8.90 8.90
394 416 434 412
131 143 152 129
88.1
0.82
24
8.90
375
125
95.5 102.0 109.0 88.8
0.85 0.69 0.52 0.94
23
20
16
24
8.90 8.90 8.90 8.90
386 408 426 404
128 140 149 127
Shaded area reflects AHRI (TVA) conditions
96.0 102.4 87.7
0.77 0.63 0.91
24
21
26
8.90 8.90 8.90
351 366 352
131 139 118
99.3 104.0 111.0 95.1
0.89 0.80 0.65 0.95
25
24
21
26
8.90 8.90 8.90 8.90
343 362 377 363
123 135 144 122
107.1
0.84
23
8.90
365
136
96.5 103.2 86.2
0.65 0.48 0.87
20
16
25
8.90 8.90 8.90
348 362 348
129 138 117
97.9 104.6 111.8 93.4
0.82 0.67 0.50 0.91
23
20
16
24
8.90 8.90 8.90 8.90
339 358 374 359
122 133 142 121
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
71
59
100.8 107.7 115.1 96.2 98.3 105.1 112.3 91.4
0.86 0.70 0.52 0.95 0.89 0.72 0.54 1.00
22
19
15
23
22
19
16
23
8.90 8.90 8.90 8.90 8.90 8.90 8.90 8.90
343 362 377 363 390 412 430 408
123 135 144 122 130 142 151 128
117.1 100.4 102.3
0.66 0.96 0.93
20
25
24
8.90 8.90 8.90
335 322 346
140 117 125
98.9 105.7 88.4
0.63 0.47 0.85
20
16
25
8.90 8.90 8.90
306 319 306
125 133 111
116.4 99.8 101.7 106.6
0.61 0.90 0.86 0.78
20
26
25
24
8.90 8.90 8.90 8.90
296 280 301 318
131 112 119 130
119.9 102.8 104.8
0.64 0.94 0.91
20
25
24
8.90 8.90 8.90
299 283 304
132 113 120
96.2 100.7 107.4
0.80 0.73 0.59
25
24
21
8.90 8.90 8.90
260 275 287
109 119 127
109.1
0.75
24
8.90
284
123
MBh 102.2 104.2
S/T
0.87 0.83
∆T
25
25
kW
8.90 8.90
HI PR 250 269
LO PR 106 112
3600
94.3
0.83
26
8.90
242
103
112.4
0.79
23
8.90
286
124
MBh 105.3 107.3
S/T
0.91 0.88
∆T
24
24
kW
8.90 8.90
HI PR 252 271
LO PR 107 114
2800
67
110.3
0.68
19
8.90
318
130
117.2 98.1 100.2 107.1
0.47 0.86 0.80 0.65
16
24
23
20
8.90 8.90 8.90 8.90
293 277 298 315
129 111 118 128
71
59
63
120.7 101.0 103.3
0.49 0.90 0.84
15
23
22
8.90 8.90 8.90
296 280 301
131 112 119
94.7 101.2 108.2
0.75 0.61 0.45
23
20
16
8.90 8.90 8.90
258 272 284
108 118 126
MBh
S/T
∆T
kW
HI PR
LO PR
92.7
0.80
24
8.90
240
102
109.7
0.63
20
8.90
281
122
MBh 100.4 102.6
S/T
0.83 0.77
∆T
24
23
kW
8.90 8.90
HI PR 247 266
LO PR 105 111
3200
67
112.9
0.66
19
8.90
284
123
Airflow
59
63
MBh 103.5 105.7
S/T
0.87 0.81
∆T
23
22
3600
kW
8.90 8.90
HI PR 250 269
LO PR 106 112
75
IDB = Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65
85.0
0.92
26
8.90
426
132
92.1
0.95
25
8.90
439
136
94.8
1.00
24
8.90
443
137
83.7
0.85
23
8.90
422
131
90.7
0.88
23
8.90
435
135
63
93.4
0.92
22
8.90
439
136
95.6
0.52
16
8.90
464
152
75.9
0.91
23
8.90
433
127
89.0
0.83
24
8.90
450
144
77.2
0.96
24
8.90
437
128
78.7
0.92
24
8.90
471
136
85.3
0.96
23
8.90
485
141
87.8
1.00
22
8.90
490
142
77.5
0.86
22
8.90
466
135
84.0
0.89
21
8.90
480
139
63
86.5
0.93
21
8.90
485
141
82.4
0.83
23
8.90
497
149
89.3
0.86
22
8.90
512
153
92.0
0.91
21
8.90
517
155
82.8
0.70
19
8.90
492
147
89.8
0.72
19
8.90
507
152
67
92.5
0.76
18
8.90
512
153
115
87.9
0.68
20
8.90
518
159
95.3
0.70
19
8.90
534
163
98.1
0.74
18
8.90
540
165
88.6
0.52
15
8.90
513
157
96.0
0.54
15
8.90
529
162
71
98.8
0.57
14
8.90
534
163
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
94.9
0.67
21
8.90
469
153
96.4 102.9 83.7
0.86 0.70 0.99
24
21
24
8.90 8.90 8.90
464 484 451
148 158 132
99.3 105.9 86.2
0.90 0.73 1.00
23
20
22
8.90 8.90 8.90
468 488 455
150 160 133
89.4
0.69
20
8.90
445
143
96.9 103.6 82.2
0.72 0.54 0.95
20
16
22
8.90 8.90 8.90
459 479 446
147 156 131
67
71
59
99.8 106.7 84.7
0.75 0.56 1.00
19
15
22
8.90 8.90 8.90
464 484 451
148 158 132
105
Product Specifications
Expanded Cooling Data — 8½ Tons (cont.)
21
3200
4000
4500
3200
4000
4500
67
15
105
103.6 107.4 117.7
0.68
MBh
S/T
131
314
12
0.45
118
295
16
0.61
129
311
12
0.43
-
136
358
12
0.46
123
335
16
0.63
134
354
12
0.44
19
143
407
12
0.47
141
403
12
0.45
24
239
103
∆T
Hi Pr
Lo Pr
110
257
22
0.69
120
272
18
0.53
128
284
12
0.34
109
268
24
0.81
116
289
22
0.72
120
127
305
18
0.55
131
135
318
12
0.35
139
328
11
113
305
24
0.83
117
315
21
121
329
22
0.74
124
339
20
132
347
18
0.56
136
358
16
119
348
24
0.85
123
358
22
0.88
127
374
22
0.76
131
386
20
0.79
138
395
18
0.58
143
407
16
0.60
147
412
13
0.37
152
425
11
0.38
125
391
24
0.88
129
403
21
0.92
130
Shaded area reflects ACCA (TVA) conditions
140
362
12
0.36
145
373
11
0.37
153
20
407
0.78
112
315
16
0.58
144
11
429
0.96
105.4 108.5 117.4 126.0 102.9 106.0 114.7 123.1 100.5 103.4 112.0 120.2 98.0 100.9 109.2 117.2 93.1
132
298
20
0.77
132
16
411
0.40
S/T
124
277
21
0.86
124
19
390
0.63
MBh
113
292
11
0.36
146
21
362
0.83
106
280
16
0.57
137
11
377
0.93
124
Lo Pr
265
19
0.75
126
16
361
0.39
-
21
0.84
118
19
342
0.61
137
387
247
0.35
140
21
318
0.80
125
-
20
0.78
91.6
127
399
18
0.81
∆T
0.55
132
11
331
0.90
118
391
-
-
-
137
434
15
0.71
149
458
12
0.49
148
454
12
0.47
149
458
16
0.62
151
463
15
0.65
143
440
13
0.45
159
478
11
0.40
161
483
11
0.42
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
133
446
20
0.93
134
450
19
0.97
128
428
19
0.78
84.8
132
441
17
0.81
91.9
133
446
17
0.85
94.7
133
421
22
0.79
145
445
18
0.60
129
432
22
0.89
63
67
155
506
11
0.49
148
486
13
0.45
96.3
153
501
11
0.47
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
156
511
14
0.66
166
533
10
0.42
137
465
20
0.80
88.8
142
480
18
0.83
165
528
10
0.40
150
491
17
0.60
160
512
12
0.39
96.1 103.2
155
506
15
0.63
96.2 104.2 111.8
143
484
18
0.87
99.1 107.3 115.1
136
460
17
0.66
87.9
140
475
15
0.68
95.3 104.4
142
479
14
0.71
98.1 107.5
115
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
154
464
12
0.39
95.9 103.8 111.4 86.3
137
434
20
0.82
138
438
19
0.86
131
417
18
0.65
94.9 104.0
135
430
16
0.67
99.2 102.8 112.7
129
403
18
0.85
Hi Pr
0.72
121
16
318
0.38
-
370
14
0.43
-
-
-
-
67
0.81
114
19
301
0.59
130
344
18
0.63
99.9 109.5
129
382
16
0.65
63
S/T
133
21
280
0.78
119
-
21
0.75
96.4
122
355
19
0.78
-
-
-
-
-
59
102.2 105.9 116.0
107
125
11
295
0.88
112
343
-
-
-
131
386
16
0.68
104.4 108.2 118.6
123
358
18
0.82
-
71
114.2 117.5 127.2 136.6 111.5 114.8 124.3 133.4 108.9 112.1 121.3 130.2 106.2 109.3 118.4 127.0 100.9 103.9 112.4 120.7 93.5
114
15
283
0.37
-
325
14
0.42
67
MBh
268
0.57
125
302
18
0.61
-
-
-
-
63
Lo Pr
20
249
∆T
Hi Pr
0.76
115
-
21
0.73
98.8 102.4 112.2
116
312
19
0.75
-
-
-
-
-
59
107.6 111.5 122.1
0.84
108
302
-
-
124
339
15
0.66
107.0 110.9 121.6
117
315
18
0.79
-
71
117.6 121.1 131.0 140.6 114.9 118.3 128.0 137.4 112.1 115.4 125.0 134.1 109.4 112.6 121.9 130.8 103.9 107.0 115.8 124.3 96.3
-
286
14
0.41
67
S/T
119
266
18
0.59
-
-
-
-
63
MBh
109
-
21
0.71
101.2 104.9 114.9
111
274
19
0.73
-
-
-
-
-
59
110.3 114.3 125.2
102
269
-
120
298
15
0.64
109.7 113.7 124.5
112
277
18
0.77
-
71
Lo Pr
255
13
67
20
18
63
237
-
-
-
59
112.9 117.1 128.3
105
∆T
0.40
122
-
-
-
-
-
-
-
-
-
71
95
Entering Indoor Wet Bulb Temperature
85
Outdoor Ambient Temperature
Hi Pr
0.57
112
12
277
Lo Pr
16
263
18
244
∆T
0.41
Hi Pr
0.59
0.71
S/T
124
106
112.3 116.4 127.5
113
12
280
MBh
265
0.43
Lo Pr
18
247
∆T
Hi Pr
0.62
0.74
63
S/T
59
115.6 119.8 131.3
MBh
Airflow
75
IDB = Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65
Product Specifications
Expanded Cooling Data — 10 Tons
22www.goodmanmfg.com
SS-CPC90-150
SS-CPC90-150 www.goodmanmfg.com
3200
4000
4500
3200
4000
4500
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
22
24
28
244
105
∆T
Hi Pr
Lo Pr
112
263
28
0.86
122
277
26
0.78
130
289
23
0.63
111
274
28
0.93
118
295
28
0.89
122
129
311
26
0.81
133
138
325
23
0.65
142
335
21
116
311
28
0.95
119
321
26
123
335
28
0.92
127
346
25
134
354
26
0.83
138
365
24
121
355
29
0.98
125
366
25
1.00
129
382
28
0.95
133
394
25
0.98
141
403
27
0.85
145
416
24
0.89
150
420
23
0.69
155
433
21
0.72
127
399
28
1.00
131
411
24
1.00
133
Shaded area reflects AHRI (TVA) conditions
143
369
23
0.67
147
381
21
0.70
156
22
416
0.89
115
321
24
0.86
147
20
438
1.00
109.1 111.2 116.5 124.3 106.6 108.6 113.8 121.4 104.0 106.1 111.1 118.5 101.5 103.5 108.4 115.6 96.4
134
304
25
0.95
135
23
420
0.75
S/T
126
282
25
0.98
126
24
398
0.93
MBh
116
298
20
0.68
149
23
369
1.00
109
286
23
0.84
140
20
384
1.00
126
Lo Pr
271
25
0.93
128
23
369
0.73
149
25
0.96
120
24
349
0.90
140
26
395
252
0.65
143
24
324
1.00
128
18
416
∆T
0.81
135
20
338
1.00
120
22
399
Hi Pr
0.89
123
23
324
0.71
142
378
26
152
468
24
0.92
154
472
23
0.96
146
449
22
0.74
162
488
20
0.75
164
493
20
0.78
156
468
18
0.55
136
455
22
1.00
137
459
20
1.00
130
437
25
0.98
135
430
28
0.98
148
454
26
0.89
21
18
15
166
533
132
441
26
1.00
159
522
21
0.97
151
496
21
0.75
170
544
18
0.79
161
517
16
0.56
95.8 102.5
156
511
0.58
140
475
26
0.99
91.1
144
489
23
1.00
168
539
19
0.75
153
501
24
0.89
163
523
21
0.72
95.4 101.7
158
517
22
0.93
98.7 103.3 110.2
146
494
21
1.00
139
470
24
0.92
89.7
143
484
0.77
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
157
473
23
0.72
98.3 103.0 109.8 89.3
140
443
24
1.00
141
447
22
1.00
134
425
25
0.91
96.8 103.5 110.6 87.8
0.93
116
24
307
0.88
133
351
27
0.97
134
S/T
136
24
285
0.97
122
366
18
0.53
161
110
127
19
301
1.00
114
350
22
0.71
151
22
450
118.2 120.5 126.2 134.7 115.5 117.7 123.3 131.5 112.7 114.9 120.3 128.4 110.0 112.1 117.4 125.3 104.5 106.5 111.5 119.0 96.8
117
22
289
0.69
136
332
25
0.88
138
16
483
MBh
273
0.85
128
308
27
0.93
130
20
463
Lo Pr
24
254
∆T
Hi Pr
0.94
117
321
18
0.52
153
23
438
0.95
0.97
110
308
22
0.69
144
24
407
1.00
121.8 124.1 130.0 138.7 118.9 121.2 127.0 135.5 116.1 118.4 124.0 132.2 113.3 115.5 120.9 129.0 107.6 109.7 114.9 122.6 99.7 101.6 106.4 113.5
129
292
25
0.85
132
16
429
0.57
S/T
121
271
27
0.91
124
20
412
0.77
168
MBh
111
286
17
0.50
146
23
390
0.94
158
539
14
0.61
97.2 103.8 111.0
144
517
18
0.81
104
275
22
0.67
137
362
24
1.00
136
489
20
1.00
Lo Pr
260
25
0.83
126
377
16
0.55
162
455
20
1.00
26
0.88
118
361
20
0.74
152
488
15
0.60
242
0.49
140
342
23
0.91
140
468
19
0.81
∆T
0.65
132
318
24
0.97
131
443
22
1.00
Hi Pr
0.80
121
331
16
0.54
155
22
411
0.85
114
318
20
0.72
145
15
433
1.00
107.2 109.6 117.1 125.2 104.8 107.0 114.4 122.3 102.3 104.5 111.6 119.3 99.8 101.9 108.9 116.4 94.8
133
301
23
0.88
133
19
416
0.58
S/T
125
280
24
0.94
125
22
394
0.78
MBh
114
295
16
0.52
147
23
366
0.95
107
283
20
0.70
138
15
381
1.00
Lo Pr
268
23
0.86
127
19
365
0.56
24
0.92
119
22
346
0.75
249
0.50
142
23
321
0.92
∆T
0.67
133
15
335
1.00
Hi Pr
0.83
122
19
321
0.55
0.88
115
22
304
0.73
S/T
134
23
282
0.90
109
126
15
298
0.96
116.2 118.7 126.9 135.6 113.5 116.0 123.9 132.4 110.8 113.2 121.0 129.3 108.1 110.4 118.0 126.1 102.7 104.9 112.1 119.8 95.1
116
19
286
0.53
MBh
271
0.71
Lo Pr
23
252
∆T
Hi Pr
0.87
0.93
67
115
S/T
63
105
119.7 122.3 130.7 139.7 116.9 119.4 127.6 136.4 114.1 116.6 124.6 133.2 111.3 113.8 121.5 129.9 105.8 108.1 115.5 123.4 98.0 100.1 107.0 114.3
59
95
Entering Indoor Wet Bulb Temperature
85
Outdoor Ambient Temperature
MBh
Airflow
75
IDB = Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65
Product Specifications
Expanded Cooling Data — 10 Tons (cont.)
23
145.5
0.80
23
10.50
36.5
249
102
141.3
0.76
24
10.42
36.3
247
101
130.4
0.73
26
10.17
35.5
240
97
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
3360
4200
4725
59
143.1
0.70
20
10.42
36.3
247
100
138.9
0.67
20
10.33
36.0
244
99
128.2
0.65
23
10.09
35.3
237
97
Airflow
MBh
S/T
∆T
kW
4725
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
4200
Amps
Hi PR
Lo PR
MBh
S/T
∆T
3360
kW
Amps
Hi PR
Lo PR
149.8
0.71
21
10.72
37.2
268
108
145.4
0.68
22
10.64
36.9
266
107
134.2
0.66
24
10.38
36.2
258
104
63
148.3
0.59
17
10.64
36.9
266
107
144.0
0.56
18
10.55
36.7
263
106
132.9
0.54
20
10.30
35.9
255
103
162.1
0.54
17
11.06
38.2
283
118
157.4
0.52
18
10.97
37.9
281
117
145.3
0.50
20
10.71
37.1
272
113
67
162.5
0.41
13
10.97
37.9
281
117
157.7
0.39
13
10.88
37.6
278
116
145.6
0.37
15
10.62
36.8
269
112
174.0
0.35
12
11.41
39.3
296
126
169.0
0.33
12
11.32
39.0
293
124
155.9
0.32
14
11.05
38.1
284
121
71
142.1
0.83
23
11.31
38.8
280
107
138.0
0.79
24
11.22
38.5
277
106
127.3
0.76
27
10.94
37.7
269
103
59
139.7
0.73
20
11.21
38.5
277
106
135.7
0.69
21
11.12
38.3
274
105
125.2
0.67
23
10.86
37.4
266
102
146.3
0.74
21
11.55
39.6
301
114
142.1
0.71
22
11.46
39.3
298
113
131.1
0.68
24
11.18
38.4
289
110
63
144.8
0.61
17
11.45
39.3
298
113
140.6
0.58
18
11.36
39.0
295
112
129.8
0.56
20
11.09
38.2
286
108
158.4
0.56
17
11.92
40.6
318
125
153.8
0.53
18
11.82
40.3
315
123
141.9
0.52
20
11.53
39.4
305
120
67
158.7
0.42
13
11.82
40.3
315
123
154.1
0.40
14
11.73
40.0
312
122
142.2
0.39
15
11.44
39.1
302
118
75
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.
75
70
IDB
65
170.0
0.36
12
12.31
41.8
332
133
165.0
0.34
12
12.21
41.5
328
131
152.3
0.33
14
11.91
40.6
319
127
71
138.7
0.85
23
12.02
41.5
318
111
134.7
0.81
24
11.92
41.2
315
110
124.3
0.78
27
11.63
40.3
306
107
154.6
0.57
17
12.68
43.4
362
129
150.1
0.55
18
12.57
43.1
358
128
138.5
0.53
20
12.26
42.1
347
124
165.9
0.37
12
13.10
44.7
377
138
161.1
0.35
12
12.99
44.4
374
137
148.7
0.34
14
12.67
43.4
362
132
135.3
0.88
23
12.65
43.8
363
117
131.4
0.84
24
12.54
43.4
359
116
121.3
0.81
27
12.23
42.5
348
112
139.3
0.78
21
12.92
44.6
390
125
135.3
0.75
22
12.82
44.3
386
123
124.9
0.72
25
12.50
43.3
375
120
150.8
0.59
17
13.35
45.8
412
136
146.4
0.57
18
13.24
45.5
408
135
135.2
0.55
20
12.91
44.5
396
131
161.9
0.38
12
13.80
47.3
430
145
157.2
0.36
13
13.68
46.9
425
143
145.1
0.35
14
13.34
45.8
413
139
Shaded area reflects ACCA (TVA)Rating Conditions
142.8
0.76
21
12.28
42.3
343
119
138.7
0.72
22
12.18
42.0
339
117
128.0
0.70
24
11.88
41.0
329
114
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
59
63
67
71
59
63
67
71
136.4 141.4 154.9
133.1 137.9 151.1
0.75 0.62 0.43
0.77 0.64 0.45
20
17
13
20
17
13
11.92 12.18 12.57
12.54 12.82 13.24
41.2 42.0 43.1
43.4 44.3 45.5
315 339 358
359 386 408
110 117 128
116 123 135
132.4 137.3 150.4
129.2 133.9 146.7
0.71 0.60 0.41
0.74 0.61 0.43
21
18
14
21
18
14
11.82 12.08 12.47
12.44 12.71 13.13
40.9 41.7 42.8
43.1 44.0 45.2
312 336 355
355 382 404
109 116 127
115 122 133
122.2 126.7 138.8
119.3 123.6 135.4
0.69 0.57 0.40
0.71 0.59 0.41
23
20
15
23
20
15
11.53 11.78 12.16
12.13 12.39 12.80
40.0 40.7 41.8
42.1 43.0 44.1
303 326 344
345 371 392
106 113 123
111 118 129
132.4
0.81
21
13.47
47.0
439
131
128.5
0.78
22
13.36
46.6
435
129
118.6
0.75
24
13.03
45.6
422
125
63
131.0
0.67
17
13.36
46.6
434
129
127.2
0.64
18
13.25
46.3
430
128
117.4
0.61
20
12.92
45.2
417
124
143.3
0.62
17
13.92
48.3
463
143
139.1
0.59
18
13.80
47.9
459
141
128.4
0.57
20
13.45
46.8
445
137
67
143.6
0.46
13
13.80
47.9
459
141
139.4
0.44
13
13.68
47.5
454
140
128.7
0.43
15
13.34
46.4
441
135
153.8
0.40
12
14.39
49.8
483
152
149.3
0.38
12
14.27
49.4
479
150
137.8
0.36
14
13.90
48.3
464
146
71
119.1
0.92
21
13.64
48.3
451
127
115.6
0.88
22
13.53
47.9
446
126
106.7
0.84
25
13.19
46.8
433
122
59
117.1
0.81
18
13.52
47.9
446
126
113.7
0.77
19
13.41
47.6
442
124
104.9
0.74
21
13.07
46.5
428
121
122.6
0.82
20
13.95
49.3
485
135
119.1
0.78
20
13.83
48.9
480
134
109.9
0.75
23
13.48
47.8
466
130
63
121.4
0.67
16
13.83
48.9
480
134
117.9
0.64
17
13.71
48.5
475
132
108.8
0.62
18
13.37
47.4
461
128
132.7
0.62
16
14.41
50.7
512
147
128.9
0.59
17
14.29
50.3
507
146
118.9
0.57
19
13.93
49.1
492
142
67
133.0
0.47
12
14.29
50.3
507
146
129.1
0.45
13
14.17
49.9
502
144
119.2
0.43
14
13.81
48.7
487
140
115
142.5
0.40
11
14.90
52.3
534
157
138.3
0.38
12
14.77
51.9
529
155
127.7
0.37
13
14.40
50.7
513
151
71
-
KW = Total system power
Amps: Unit amps (comp.+ evaporator + condenser fan motors)
128.6
0.91
23
13.18
46.0
408
123
124.8
0.87
24
13.07
45.7
404
121
115.2
0.84
26
12.74
44.7
392
118
59
126.4
0.80
20
13.07
45.7
404
121
122.7
0.76
21
12.96
45.4
400
120
113.3
0.74
23
12.64
44.3
388
117
105
Product Specifications
Expanded Cooling Data — 12½ Tons
24www.goodmanmfg.com
SS-CPC90-150
SS-CPC90-150 www.goodmanmfg.com
150.7
0.92
27
10.67
37.0
254
104
146.3
0.88
28
10.58
36.8
252
103
135.0
0.85
31
10.33
36.0
244
99
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
3360
4200
4725
59
148.1
0.88
25
10.58
36.8
252
103
143.8
0.84
26
10.50
36.5
249
102
132.7
0.81
29
10.25
35.8
242
98
Airflow
MBh
S/T
∆T
kW
4725
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
4200
Amps
Hi PR
Lo PR
MBh
S/T
∆T
3360
kW
Amps
Hi PR
Lo PR
153.6
0.89
26
10.89
37.7
274
110
149.1
0.85
28
10.81
37.5
271
109
137.6
0.82
31
10.55
36.7
263
106
63
151.3
0.82
24
10.81
37.5
271
109
146.9
0.78
25
10.72
37.2
268
108
135.6
0.76
28
10.47
36.4
260
105
160.9
0.80
25
11.24
38.7
289
120
156.2
0.76
26
11.15
38.4
286
119
144.1
0.74
29
10.88
37.6
278
116
67
161.7
0.67
21
11.15
38.4
286
119
157.0
0.64
22
11.06
38.2
283
118
144.9
0.62
24
10.79
37.3
275
114
171.6
0.65
22
11.60
39.8
302
128
166.6
0.62
23
11.51
39.6
299
127
153.8
0.60
25
11.23
38.7
290
123
71
172.8
0.50
17
11.51
39.6
299
127
167.8
0.48
18
11.42
39.3
296
126
154.9
0.46
19
11.14
38.4
287
122
147.2
0.95
27
11.49
39.4
286
109
142.9
0.91
28
11.40
39.1
283
108
131.9
0.88
32
11.12
38.3
274
105
59
144.6
0.91
26
11.40
39.1
283
108
140.4
0.87
27
11.31
38.8
280
107
129.6
0.84
30
11.03
38.0
271
104
150.0
0.92
27
11.74
40.1
307
116
145.6
0.88
28
11.64
39.8
304
115
134.4
0.85
31
11.36
39.0
295
112
63
147.8
0.85
25
11.64
39.8
304
115
143.5
0.81
26
11.55
39.6
301
114
132.4
0.78
28
11.27
38.7
292
111
157.1
0.83
25
12.12
41.2
324
127
152.5
0.79
26
12.02
40.9
321
126
140.8
0.76
29
11.72
40.0
312
122
67
157.9
0.69
21
12.02
40.9
321
126
153.3
0.66
22
11.92
40.6
318
125
141.5
0.64
25
11.63
39.7
309
121
75
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.
85
80
IDB
65
167.6
0.67
22
12.51
42.4
338
135
162.7
0.64
23
12.41
42.1
335
134
150.2
0.62
25
12.10
41.2
325
130
71
168.8
0.52
17
12.41
42.1
335
134
163.9
0.49
18
12.31
41.8
332
133
151.3
0.48
20
12.01
40.9
322
129
143.7
0.98
27
12.22
42.1
325
114
139.5
0.93
28
12.12
41.8
322
113
128.7
0.90
32
11.82
40.9
312
109
153.4
0.85
25
12.89
44.1
369
132
148.9
0.81
26
12.78
43.7
365
131
137.4
0.78
29
12.47
42.8
354
127
163.6
0.69
22
13.32
45.4
385
141
158.9
0.66
23
13.21
45.1
381
139
146.6
0.63
25
12.88
44.1
370
135
140.2
1.00
27
12.86
44.4
370
119
136.1
0.96
29
12.75
44.1
366
118
125.6
0.93
32
12.43
43.1
355
115
142.9
0.97
27
13.14
45.3
398
127
138.7
0.93
28
13.03
45.0
394
126
128.0
0.89
31
12.71
43.9
382
122
149.6
0.88
26
13.57
46.5
420
139
145.3
0.84
27
13.46
46.2
416
137
134.1
0.81
30
13.12
45.1
404
133
159.6
0.71
22
14.03
48.0
438
148
155.0
0.68
23
13.91
47.6
434
146
143.0
0.65
26
13.56
46.5
421
142
Shaded area reflects ACCA (TVA)Rating Conditions
146.4
0.94
27
12.48
42.9
349
121
142.2
0.90
28
12.38
42.6
346
120
131.2
0.87
31
12.08
41.6
336
116
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
59
63
67
71
59
63
67
71
141.2 144.3 154.1 164.8 137.7 140.8 150.4 160.8
0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55
26
25
21
17
26
25
21
17
12.12 12.38 12.78 13.21 12.75 13.03 13.46 13.91
41.8 42.6 43.7 45.1 44.1 45.0 46.2 47.6
322 346 365 381 366 394 416 434
113 120 131 139 118 126 137 146
137.1 140.1 149.7 160.0 133.7 136.7 146.0 156.1
0.89 0.83 0.68 0.51 0.92 0.86 0.70 0.52
27
26
22
18
27
26
22
18
12.02 12.28 12.68 13.10 12.65 12.93 13.35 13.80
41.5 42.3 43.4 44.7 43.8 44.6 45.9 47.3
318 343 362 377 363 390 412 430
111 119 129 138 117 125 136 145
126.5 129.3 138.1 147.7 123.4 126.1 134.8 144.1
0.86 0.80 0.65 0.49 0.88 0.83 0.67 0.50
30
28
25
20
30
29
25
20
11.72 11.98 12.36 12.77 12.33 12.60 13.01 13.45
40.6 41.3 42.4 43.7 42.8 43.6 44.8 46.2
309 332 351 366 352 378 400 417
108 115 126 134 114 121 132 140
135.7
1.00
26
13.70
47.7
448
133
131.8
0.96
28
13.59
47.3
443
132
121.6
0.93
31
13.24
46.3
430
128
63
133.7
0.94
24
13.59
47.3
443
132
129.8
0.89
25
13.47
47.0
439
131
119.8
0.86
28
13.13
45.9
426
127
142.1
0.91
25
14.16
49.0
473
145
138.0
0.87
26
14.04
48.7
468
144
127.4
0.84
29
13.68
47.5
454
140
67
142.9
0.76
21
14.04
48.7
468
144
138.7
0.73
22
13.92
48.3
464
143
128.0
0.70
25
13.57
47.2
450
138
151.6
0.74
22
14.63
50.6
493
155
147.2
0.70
23
14.51
50.2
488
153
135.9
0.68
25
14.14
49.0
474
149
71
152.7
0.57
17
14.51
50.2
488
153
148.3
0.54
18
14.39
49.8
483
152
136.9
0.52
20
14.02
48.7
469
147
123.3
1.00
24
13.87
49.1
460
129
119.7
1.00
26
13.76
48.7
455
128
110.5
0.97
29
13.41
47.6
442
124
59
121.2
1.00
24
13.76
48.7
455
128
117.7
0.96
25
13.64
48.3
451
127
108.6
0.93
28
13.30
47.2
437
123
125.7
1.00
24
14.18
50.1
495
138
122.1
0.97
26
14.06
49.7
490
136
112.7
0.94
29
13.71
48.5
475
132
63
123.9
0.94
23
14.06
49.7
490
136
120.3
0.90
24
13.95
49.3
485
135
111.0
0.87
26
13.59
48.2
470
131
131.7
0.92
24
14.66
51.5
522
150
127.8
0.88
25
14.53
51.1
517
149
118.0
0.84
27
14.16
49.9
502
144
67
132.3
0.77
20
14.53
51.1
517
149
128.5
0.73
21
14.41
50.7
512
147
118.6
0.71
23
14.04
49.5
497
143
115
140.5
0.75
20
15.16
53.1
545
160
136.4
0.71
21
15.03
52.7
539
159
125.9
0.69
24
14.64
51.5
523
154
71
141.5
0.57
16
15.03
52.7
539
159
137.3
0.55
16
14.90
52.3
534
157
126.8
0.53
18
14.52
51.1
518
152
KW = Total system power
Amps: Unit amps (comp.+ evaporator + condenser fan motors)
133.1
1.00
26
13.40
46.8
416
125
129.3
1.00
28
13.29
46.4
412
124
119.3
0.96
31
12.96
45.3
400
120
59
130.9
1.00
25
13.29
46.4
412
124
127.0
0.95
26
13.18
46.1
408
123
117.3
0.92
29
12.85
45.0
396
119
105
Product Specifications
Expanded Cooling Data — 12½ Tons (cont.)
25
Product Specifications
APPENDIX C UNIT DIMENSIONS
Dimensions
7.5
Y
8.5
10
12.5
52 7/8" 52 7/8" 52 7/8"
58 7/8"
L
99 1/8”
Y
H
Model
Size
7½ to 10 Tons
12½ Tons
Dimensions
H
L
52⅞”
58⅞”
99⅛”
99⅛”
61¾”
61
3/4”
12⅝”
12
5/8”
28⅜”
28
3/8”
77⅜”
3/8”
RETURN
13⅞”
13
7/8”
55⅞”
7/8”
36⅜”
36
3/8”
SUPPLY
66½”
1/2”
RETURN
66¼”
1/4”
Horizontal Discharge
NOTE
5 3/8”
5⅜”
For horizontal discharge, remove the supply
and return duct covers and place them over
the vertical discharge return and supply
openings. Install with insulation facing up,
using the longer screws provided in the
literature package.
SUPPLY
77½”
1/2”
Vertical Discharge (Bottom of Unit)
20
26www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Unit Clearances
Maintain an adequate clearance around the unit for safety, service, maintenance,
and proper unit operation. Leave a total clearance of 75” on the main control
panel side of the unit for possible removal of fan shaft, coil, electric heat, and
gas furnace. Leave a clearance of 48” on all other sides of the unit for possible
compressor removal or service access, and to ensure proper ventilation
and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit
ingestion of exhaust air into the unit’s fresh-air intake.
48”
48”
36” Min.
75”
48”
Electrical Entrance Locations
Dimples Mark Drill Locations
11⅝”
High-Voltage Entrance
103/16”
Low-Voltage Entrance
3”
SS-CPC90-150 www.goodmanmfg.com
27
Product Specifications
Roof Curb Installation — Rigging
Provisions for forks have been included in the unit base frame. No other
fork locations are approved.
• Unit must be lifted by the four lifting holes located at the base
frame corners.
• Lifting cables should be attached to the unit with shackles.
• The distance between the crane hook and the top of the unit must
not be less than 60”.
• Two spreader bars must span over the unit to prevent damage to
the cabinet by the lift cables. Spreader bars must be of sufficient
length so that cables do not come in contact with the unit during
transport. Remove wood struts mounted beneath unit base frame
before setting unit on roof curb. These struts are intended to protect
unit base frame from fork lift damage. To remove the struts, extract
the sheet metal retainers and pull the struts through the base of the
unit. Refer to rigging label on the unit.
Important: If using bottom discharge with roof curb, duct-work
should be attached to the curb prior to installing the unit. Duct-work
dimensions are shown in Roof Curb Installation Instructions Manual.
Refer to the Roof Curb Installation Instructions
for proper curb installation. Curbing must be
installed in compliance with the National
Roofing Contractors Association Manual.
Lower unit carefully onto roof mounting curb.
30”
While rigging the unit, the center of gravity
will cause the condenser end to be lower
Compressor 1
than the supply air end.
Bring condenser end of unit into alignment
Compressor 2
with the curb. With condenser end of the
unit resting on curb member and using curb
as a fulcrum, lower opposite end of the unit
until entire unit is seated on the curb. When
a rectangular cantilever curb is used, take
care to center the unit. Check for proper
alignment and orientation of supply and
49”
return openings with duct.
Return
Evaporator Coil
Supply
Corner & Center-of-Gravity Locations
Unit Weights
7½-Ton A Models
Weights (lbs)
7½-Ton B Models
& 8½-Ton
Weights (lbs)
10-Ton
Weights (lbs)
12½-Ton
Weights (lbs)
Weight A
280
260
285
420
Weight B
280
245
285
335
Weight C
280
240
285
290
Weight D
280
225
285
230
Shipping Weight
1150
1000
1175
1300
Operating Weight
1110
975
1135
1275
To assist in determining rigging requirements, unit weights are shown to the right.
Note: These weights are calculated without accessories installed.
28www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Roof Curb Installation (cont.)
3-D View
92¼
15⅜ x 31⅛
Supply Opening
14⅝ x 38⅜
Return Opening
Curb installations must comply with local codes and should follow the
established guidelines of the National Roofing Contractors Association.
Proper unit installation requires that the roof curb be firmly and permanently
attached to the roof structure. Check for adequate fastening method prior to
setting the unit on the curb.
Full perimeter roof curbs are available from the factory and are shipped
unassembled. The installing contractor is responsible for field assembly,
squaring, leveling, and mounting on the roof structure. All required hardware
necessary for the assembly of the sheet metal curb is included in the curb
accessory package.
• Determine sufficient structural support before locating and mounting the
curb and package unit.
• Duct-work must be constructed using industry guidelines. The duct-work
must be placed into the roof curb before mounting the package unit. Our
full perimeter curbs include duct connection frames to be assembled with
the curb. Cantilevered-type curbs are not available from the factory.
• Contractor furnishes curb insulation, cant strips,
flashing, and general roofing material.
• Support curbs on parallel sides with roof members.
To prevent damage to the unit, the roof members
53¼
cannot penetrate supply and return duct openings.
Note: The unit and curb accessories are designed to
allow vertical duct installation before unit placement.
Duct installation after unit placement is not
14
recommended.
See the manual shipped with the roof curb for
1⅝
assembly and installation instructions.
¾
14
1⅜
Top View
Power Wiring
Thermostat
Wiring
Power and Low-Voltage Block Locations
SS-CPC90-150 www.goodmanmfg.com
29
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
⚠
Warning
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
Product Specifications
Wiring Diagram — CPC090-120 (for models with serial numbers 0907 and below)
30www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Wiring Diagram — CPC090-120 (cont.) (for models with serial numbers 0907 and below)
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
SS-CPC90-150 ⚠
Warning
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
www.goodmanmfg.com
⚡
31
Product Specifications
Wiring Diagram — CPC090-150
SMOKE/FIRE DETECTOR
REPLACES JUMPER
RD
G
BL
BR
RD
GR
SPEED
UP
NO
K1
COM
K1
NOTE #2 NC
M1 M2
C
S1
PK
RD
GR
2
3
RD
BL
YL
208 240
460
575
T3
RD
L3
L2
T2
C
24V
L1
T1
BL
BL
PU
BK
BL
TR
1
BR S2
EBTDR
R
XFMR-R
XFMR-C
C
TB1
OR
BK
OR
CC2
BK
YL
BK
RD
SEE
NOTE #2
OR
RD
PB
P
O
W
E
R
S
U
P
P
L
Y
BL
BL
BK
BL
BK
OR
BK
L1
RD
OR
GR
L3
L2
PU
T1
T2
BK
YL
COMP2
CM2
L2
BK GND
C
L1
T1
BK
CC1
BR
BK
T3 T2 T1
BK
RD
L3
T2
BK
RD
T3 T2 T1
BK
T3
BC
BL
BR
T3
RD
F
PU
C
BK
YL
RCCF2
C
YL
RD
BR
OR
YL
RD
RCCF1
BK
C
BK
BR
PU
F
CM1
COMP1
RD OR
2
0
8
2
4
0
4
6
0
5
7
5
/
3
/
6
0
PU
YL
SEE
NOTE 3
PLF 2
BK
BL
HPS1
LPS1
GR
BK
9
OR
BK
BL
3
6
8
5
2
7
4
1
YL
EM
PU
WH
PU
WH
YL
BK
WH
PLF 1
3
6
9
2
5
8
1
4
7
YL
PU
RD
GR
WH
BR
BL
RD
RD
PU
BR
BL
OR
WH
O
++
TB1
BL
YL
LPS2
T
H
E
R
M
O
S
T
A
T
Y1
Y/Y2
R
G
W1
W2
C
SEE NOTE 4
HPS2
0140L00548 REV B
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
⚠
Warning
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
32www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Wiring Diagram — CPC090-150 (cont.)
L2
L1
L3
COMPONENT LEGEND
SUPPLY VOLTAGE
BC
CC
CM
CMR
COMP
DC
DFT
ECON
EBTD
EMR
R
EM
FC
GND
HPS
HVDR
LPS
LVDR
PB
PLF
RVC
RCCF
208-240/460/575/3/60
T2
T2
CC1
T1
CC1
COMP1
T3 CC1
T3
C
RCCF1
F
CM1
C
RCCF2
F
CM2
T2
CC2
T2
T1
T1
TB1
TR
CC2
COMP2
BLOWER CONTACTOR
COMPRESSOR CONTACTOR
CONDENSER MOTOR
CONDENSER MOTOR RELAY
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ECONOMIZER
ELECTRONIC BLOWER TIME DELAY
EVAPORATOR MOTOR RELAY
RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUPIMENT GROUND
HIGH PRESSURE SWITCH
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
POWER DISTRUBTION BLOCK
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
TERMINAL BLOCK (24V SIGNAL)
TRANSFORMER
T3 CC2
T3
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK
BLACK
BL
BLUE
BR
BROWN
GR
GREEN
OR
ORANGE
PK
PINK
PU
PURPLE
RD
RED
WH
WHIT E
YL
YELLOW
YL/PK YELLOW WITH
PINK STRIP
BL/PK BLUE WITH
PINK STRIP
THERMOSTAT
FIELD WIRING
BC
++
2 STAGE COOLING
BC
NOTES:
EM
BC
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST 105°C)
USE COPPER CONDUCTOR ONLY.
2. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE
3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR
COMPARTMENT, REMOVE MALE PLUG, ATTACH
FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
4. FOR TWO STAGE OPERATION REMOVE W1 TO W2
WIRE JUMPER.
5. FOR 208V OPERATION MOVE BLACK WIRE FROM
TERMINAL 3 TO TERMINAL 2 ON 240V
TRANSFORMER.
208-240V
OR APPROPRIATE
INPUT VOLTAGE
S2
3
1
TB1
S1
TR
24V
EBTDR
R
C
G
W1
G
R
Y1
Y/Y2
C
O
W2
WH
GR
W1
G
R
Y1
Y2
C
O
W2
RD
YL
TB1
PK
BL
OR
BR
STAT
BC
R
EBTDR
EBTDR
LPS1
PLF1
7
4
8
5
9
6
CC1
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
HPS2 CC2
HPS1
LPS2
PLF2 9 6 3
8
5
2
7
4
1
SEE NOTE 4
TB1
R
W2
O
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
SS-CPC90-150 W1
Y/
Y2
THERMOSTAT
⚠
Y1
++
G
Warning
C
SEE NOTE 3
208-240/460/575/3/60 0140L00549 REV. B
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
www.goodmanmfg.com
⚡
33
Product Specifications
Accessories
Item #
Description
Fits
Model Sizes
14CURB90150
Roof Curb 14" Tall
7½-12½ tons
25FD90150
25% Manual Fresh Air Damper
7½-12½ tons
25MFD90150
25% Motorized Fresh Air Damper
7½-12½ tons
BRD3672
Horizontal Barometric Relief Damper (two required)
7½-12½ tons
CDK120
Concentric Duct Kit
10 tons
CDK150
Concentric Duct Kit
12½ tons
CDK90102
Concentric Duct Kit
7½-8½ tons
DNBBS90150
Burglar Bar Sleeves: Includes Supply & Return
7½-12½ tons
DNECONGS90120
Downflow Economizer
7½-10 tons
DNECONGS150
Downflow Economizer
12½ tons
DNSQRRND90
Downflow Square-to-Round Adapter 20" Round
7½ tons
GHRC-1
Hurricane Restraint Clip
All Models
HailGD02
Condenser Coil Hail Guard
7½-10 tons
HailGD05
Condenser Coil Hail Guard
12½ tons
HSKT090
High-Static Kit for 7½-ton AA models & 8½-ton AA models (230/460v)
HSKT090G
High-Static Kit for BA models (230/460v)
7½ tons
HSKT120
High-Static Kit for AA models (230/460v)
10 tons
HSKT150
High-Static Kit for AA models (230/460v)
HZECONGS90150
Horizontal Economizer
7½-8½ tons
12½ tons
7½-12½ tons
LAKT02
Low-Ambient Kit for units with serial number below 0909
7½ - 12½ tons
LAKT03
Low Ambient Kit for units with serial numbers 0909 and above
7½ - 12½ tons
PE901502
Power Exhaust 208/230 Volt
7½-12½ tons
PE901504
Power Exhaust 460 Volt
7½-12½ tons
34www.goodmanmfg.com
SS-CPC90-150
Product Specifications
Notes
SS-CPC90-150 www.goodmanmfg.com
35
Product Specifications
Notes
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2011 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
36www.goodmanmfg.com
SS-CPC90-150