Download Cooper Lighting Metalux AC128T5 User's Manual
Transcript
COOPER LIGHTING - METALUX DESCRIPTION The accord(TM) redefines fluorescent lighting by improving on aesthetics, comfort and energy savings. The accord(TM) provides the right amount of light while eliminating surface shadows commonly found in parabolics. Therefore, accord(TM) increases the comfort level while providing significant energy savings. The accord(TM) is the ideal solution for offices, schools, hospitals, retail and other applications. ® Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES A ... Construction Shallow 3-1/4" deep housing is die formed of code gauge, prime cold rolled steel. Heavy gauge end plates are securely attached with screws for strength and rigidity and the elimination of gaps. Four auxiliary fixture end suspension points are provided. Large access plate for supply connection. C ... Ballast Access Ballast is mounted on a heavy gauge access plate and can be accessed from above the ceiling line. E ... Reflectors Reflector has high reflectance baked matte white enamel finish for luminous uniformity. D ... Finish Durable cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition. B ... Electrical* Ballasts are Class "P" and are positively secured. Rotor-lock lampholders ensure positive lamp retention. UL/CUL listed. Suitable for damp locations. F ... Shielding Positively retained frosted acrylic profile lenses provide a soft but effective distribution of light. AC 128T5 154T5 A F D E BC T5 LAMP 1' X 4' Recessed Troffer Series MOUNTING DATA 6" [153mm] LAMP CONFIGURATIONS E N E R G Y D ATA Y Input Watts: X EB Ballast & STD Lamps @ 277V 128T5 (34) 11-3/4" [299mm] Luminaire Efficacy Rating LER =FL64 LPW Catalog Number: AC-128T5 48-3/8" [1229mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.88 CEILING COMPATIBILITY *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. ***See Drywall Frame Kit Accessory G Grid/Lay-in Standard F Drywall Frame Kit Ceiling Ty p e** Trim Type Exposed Grid Concealed T Slot Grid Flange G G or T G or T *** LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADF051799 08/12/2008 2:37:31 PM PHOTOMETRICS AC AC-128T5 Candlepower Electronic Ballast 2600 Lumens || Along II 738 734 723 705 679 647 609 565 517 465 411 354 295 236 175 115 60 18 0 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 F28T5/835 Lamps Spacing criterion: (II) 1.2 x mounting height, ( ) 1.4 x mounting height Efficiency 87.4% Test Report: 241P113 LER = FL62 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.88 45° 738 736 730 718 701 679 654 623 588 548 502 452 396 334 248 154 75 15 1 Across 738 736 732 725 715 702 685 663 635 601 559 511 443 334 221 133 63 11 1 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 104 95 86 78 72 66 61 56 52 49 46 104 91 79 69 61 54 49 44 40 37 34 104 87 73 62 53 46 41 36 33 29 27 104 84 68 56 47 40 35 31 27 25 22 102 93 84 76 70 64 59 55 51 47 44 102 89 77 68 60 53 48 43 40 36 33 102 86 72 49 43 38 34 31 28 25 23 102 83 67 56 47 40 35 31 27 24 22 20% 50% 50 30 10 30% 50 30 10 50 97 85 74 65 58 51 46 42 38 35 33 93 82 71 63 56 50 45 41 37 34 32 89 79 69 60 54 48 43 40 36 33 31 97 82 70 59 51 45 40 35 32 29 26 97 80 66 55 46 40 35 30 27 24 22 93 80 68 58 50 44 39 35 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 585 973 1788 2271 2271 %Lamp 22.5 37.4 68.8 87.4 87.4 %Fixture 25.8 42.8 78.7 100.0 100.0 Average 0-Deg cd/sm 1768 1659 1501 1195 555 93 77 64 54 46 39 34 30 27 24 22 Average 45-Deg cd/sm 2084 2119 2125 1600 463 10% 30 10 89 77 66 56 49 43 38 34 31 28 26 0% 0 89 75 63 53 45 39 34 30 27 24 22 87 73 61 52 43 37 32 28 25 22 20 Average 90-Deg cd/sm 2285 2395 2125 1382 339 ORDERING INFORMATION S A M P L E N U M B E R : A C - 1 2 8 T 5 - U N V- E B T 1 N D I M Rating Blank= Standard NY=New York Rated ATW-SW4= Chicago Rated Width(5) Blank=1' Width Series AC=Accord Series (1) Number of Lamps 1=1 Lamp Shielding Blank=Frosted Acrylic (standard) Wattage (Length) 28T5=28W T5 (48") 54T5=54W T5HO (48") Voltage (1) UNV=Universal Voltage 120-277 (Not included) Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed (2) Lamps L5835=T5 Lamp, 3500K L5841=T5 Lamp, 4100K L5835HL=T5 Lamp, 28W, 3500K, 2900 Lumens L5841HL=T5 Lamp, 28W, 4100K, 2900 Lumens Ballast Type EBT No. of Ballast 1 or 2 =T5 Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% Packaging U=Unit Pack PALC=Job Pack, in carton Ballast Factor/Type (For 28W T5 Lamp Only) N=Normal Light Output .95 BF (2) H=High Light Output 1.15 BF (2), (4) NDIM=Normal .95-1.0 BF Step Dimming (3) HDIM=High 1.15 BF Step Dimming (3), (4) (3) NOTES: Products also available in non-US voltages and frequencies for international markets. .95 and 1.15 ballast factor available for 28W T5 lamps only. Step Dimming ballast available for 28W T5 lamps only. (4) (5) 1-Lamp ballast in the High Ballast factor not available. 2-Lamp ballast will not operate 1-Lamp. 1' x 4' Accord is not designed for continuous row mount applications. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SHIPPING INFORMATION Specifications and Dimensions subject to change without notice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADF051799 08/12/2008 2:37:31 PM