Download Cooper Lighting Metalux AC128T5 User's Manual

Transcript
COOPER LIGHTING - METALUX
DESCRIPTION
The accord(TM) redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The accord(TM) provides the right amount of
light while eliminating surface shadows commonly found in parabolics.
Therefore, accord(TM) increases the comfort level while providing
significant energy savings.
The accord(TM) is the ideal solution for offices, schools, hospitals, retail and
other applications.
®
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Shallow 3-1/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Heavy gauge end
plates are securely attached with
screws for strength and rigidity
and the elimination of gaps. Four
auxiliary fixture end suspension
points are provided. Large access
plate for supply connection.
C ... Ballast Access
Ballast is mounted on a heavy
gauge access plate and can be
accessed from above the ceiling
line.
E ... Reflectors
Reflector has high reflectance
baked matte white enamel finish
for luminous uniformity.
D ... Finish
Durable cold rolled steel with
multistage, iron phosphate
pretreatment and white enamel
finish to ensure maximum bonding
and rust inhibition.
B ... Electrical*
Ballasts are Class "P" and are
positively secured. Rotor-lock
lampholders ensure positive lamp
retention. UL/CUL listed. Suitable
for damp locations.
F ... Shielding
Positively retained frosted acrylic
profile lenses provide a soft but
effective distribution of light.
AC
128T5
154T5
A
F
D
E
BC
T5 LAMP
1' X 4' Recessed
Troffer Series
MOUNTING DATA
6"
[153mm]
LAMP CONFIGURATIONS
E N E R G Y D ATA
Y
Input Watts:
X
EB Ballast & STD Lamps @ 277V
128T5 (34)
11-3/4"
[299mm]
Luminaire Efficacy Rating
LER =FL64 LPW
Catalog Number: AC-128T5
48-3/8" [1229mm]
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.88
CEILING COMPATIBILITY
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
G
Grid/Lay-in
Standard
F
Drywall Frame
Kit
Ceiling
Ty p e**
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G or T
G or T
***
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADF051799
08/12/2008 2:37:31 PM
PHOTOMETRICS
AC
AC-128T5
Candlepower
Electronic Ballast
2600 Lumens
||
Along II
738
734
723
705
679
647
609
565
517
465
411
354
295
236
175
115
60
18
0
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
F28T5/835 Lamps
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.4 x
mounting height
Efficiency 87.4%
Test Report:
241P113
LER = FL62
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.88
45°
738
736
730
718
701
679
654
623
588
548
502
452
396
334
248
154
75
15
1
Across
738
736
732
725
715
702
685
663
635
601
559
511
443
334
221
133
63
11
1
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
104
95
86
78
72
66
61
56
52
49
46
104
91
79
69
61
54
49
44
40
37
34
104
87
73
62
53
46
41
36
33
29
27
104
84
68
56
47
40
35
31
27
25
22
102
93
84
76
70
64
59
55
51
47
44
102
89
77
68
60
53
48
43
40
36
33
102
86
72
49
43
38
34
31
28
25
23
102
83
67
56
47
40
35
31
27
24
22
20%
50%
50 30 10
30%
50 30 10
50
97
85
74
65
58
51
46
42
38
35
33
93
82
71
63
56
50
45
41
37
34
32
89
79
69
60
54
48
43
40
36
33
31
97
82
70
59
51
45
40
35
32
29
26
97
80
66
55
46
40
35
30
27
24
22
93
80
68
58
50
44
39
35
31
28
26
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
585
973
1788
2271
2271
%Lamp
22.5
37.4
68.8
87.4
87.4
%Fixture
25.8
42.8
78.7
100.0
100.0
Average
0-Deg
cd/sm
1768
1659
1501
1195
555
93
77
64
54
46
39
34
30
27
24
22
Average
45-Deg
cd/sm
2084
2119
2125
1600
463
10%
30 10
89
77
66
56
49
43
38
34
31
28
26
0%
0
89
75
63
53
45
39
34
30
27
24
22
87
73
61
52
43
37
32
28
25
22
20
Average
90-Deg
cd/sm
2285
2395
2125
1382
339
ORDERING INFORMATION
S A M P L E N U M B E R : A C - 1 2 8 T 5 - U N V- E B T 1 N D I M
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
Width(5)
Blank=1' Width
Series
AC=Accord Series
(1)
Number of Lamps
1=1 Lamp
Shielding
Blank=Frosted Acrylic
(standard)
Wattage (Length)
28T5=28W T5 (48")
54T5=54W T5HO (48")
Voltage (1)
UNV=Universal Voltage
120-277
(Not included)
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed
(2)
Lamps
L5835=T5 Lamp,
3500K
L5841=T5 Lamp,
4100K
L5835HL=T5
Lamp, 28W,
3500K, 2900
Lumens
L5841HL=T5
Lamp, 28W,
4100K, 2900
Lumens
Ballast Type
EBT
No. of Ballast
1 or 2
=T5 Linear Electronic
Program Rapid Start
Total Harmonic
Distortion < 10%
Packaging
U=Unit Pack
PALC=Job Pack,
in carton
Ballast Factor/Type
(For 28W T5 Lamp Only)
N=Normal Light Output .95 BF (2)
H=High Light Output 1.15 BF (2), (4)
NDIM=Normal .95-1.0 BF Step Dimming (3)
HDIM=High 1.15 BF Step Dimming (3), (4)
(3)
NOTES: Products also available in non-US voltages and frequencies for international markets. .95 and 1.15 ballast factor available for 28W T5 lamps only. Step Dimming ballast available for 28W T5 lamps only.
(4)
(5)
1-Lamp ballast in the High Ballast factor not available. 2-Lamp ballast will not operate 1-Lamp. 1' x 4' Accord is not designed for continuous row mount applications. For complete product data, reference the
Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
SHIPPING INFORMATION
Specifications and Dimensions subject to change without notice.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADF051799
08/12/2008 2:37:31 PM