Download Red Hat APPLICATION STACK 2.1 RELEASE User guide
Transcript
o If the ULA field has the value "0000000000000000", continue to wait and not issue any CLI commands besides "show controller". Here is an example output of the condition where you would want to wait: $ show controller ************************* * Controller(s) * ************************* | Up Time | |Encl| |… Idx|Name |Mastership|Locality| D: H: M: S|RP| ID |Idx | ULA |… -----------------------------------------------------------------------------------------------… 0 A PRIMARY LOCAL 0000:20:24:34 1 0001ff0900180000 0 00000001ff0800ac … 1 B SECONDARY REMOTE 0000:00:00:05 1 0001ff09002d0000 0 0000000000000000 … Total Controllers: 2 o • 5.2 Some sequential read workloads with request sizes between 128 KB and 1024 KB may require enabling read ahead caching (prefetch) to obtain full performance. (SET POOL <#|*> READ_AHEAD_CACHING ON). (DE9676) SFA12K-20, SFA12K-40, and SFA12K-E • 5.3 When the ULA number has something other than all zeros for the remote controller, it is now safe to issue CLI commands and avoid the communication problems. An issue exists where a drive inserted into the front slots (slots 1-14) of the SS8460 may not be seen. This occurs only with the Hitachi 3TB NL-SAS drive and is an issue with the SS8460 enclosure firmware v0103. To workaround this problem, move the drive to another row in the enclosure. This will be fixed with a new enclosure firmware release for the SS8460. (DE9721) SFA12K-20E and SFA10K-E • VNC connections not authenticated or encrypted for VMs (DE6353) On SFA10K-E and SFA12K-20E controllers, currently VNC connections to Virtual Machines (VMs) are not authenticated or encrypted. Customers concerned about security access to these VMs should disable the VNC stack attribute. For example, to disable VNC connections for a stack, type app set stack XXX vnc=false where XXX is the stack id. Note, changing this stack attribute will take effect the next time the stack is started. • Clocksource tsc unstable errors (DE4620) On SFA12K-20E controllers, error messages similar to the following may be reported on the running VM with dmesg or in system logging: Clocksource tsc unstable (delta = -519494463 ns). Enable clocksource failover by adding clocksource_failover kernel parameter. A workaround has been provided for GRIDScaler 2.0.0, so this error should no longer appear. For other releases, the following workaround can be applied to have the kernel fallback to HPET mode if the guest OS detects a problem with TSC. In the kernel parameter list of the VMs, add the following line to the VM kernel boot line in /boot/grub/grub.conf. clocksource_failover=1 DataDirect Networks SFA™ OS 2.1.1.2 Release Notes Revision A2 | 9