Download Comtech EF Data SDM-650B Specifications
Transcript
Chapter 16. BUC FSK COMMUNICATIONS 16.1 Introduction The modulator includes capability to communicate with an ODU Block Up Converter (BUC) using an FSK signal multiplexed onto the IF output connector along with the TX IF signal, 10 MHX reference, and DC power to the BUC. The M&C implements commands to control BUC functions and to query the BUC for configuration or status information. FSK Transmitter Frequency FSK Deviation Deviation Tolerance Output Level Start Tone Time Output Impedance Start Time FSK Receiver Locking Range Input Sensitivity Transmission Protocol Baud Rate Data Bits Parity Stop Bits Message Rate BUC Response Time Maximum Response Time 650 kHz ± 5 % ± 60 kHz nominal (+60 kHz mark) ± 50 kHz minimum, ± 70 kHz maximum -5 to –15 dBm 10 ms minimum 50 Ω 710 kHz ± 32.5 kHz -15 dBm (50Ω) 9600 bps 8 None 1 1 every 40 msec 12 msec, typical 40 msec Note: If the BUC does not respond within the maximum response time the IDU should cyclically repeat the command. 16–1