Transcript
20.START-UP WARNING 1- 2- 3- 4- 5- 6- 7- 8- 9- i The operations related to point 5 are performed without safeties. The trimmer can only be adjusted with the automation idle. The automation automatically slows when approaching the end stops. At every start-up the control panel receives a RESET and the first operation is performed at reduced speed (automation position acquisition). Make a jumper for the N.C. safety contacts. Set TC=MAX and R1=MAX. Use DIP2 to set the required direction. Manually move the door and make sure the entire stroke is correct and without friction. Switch on and check that the automation is operating correctly with subsequent opening and closing commands. Connect the safety devices (removing the relative jumpers) and check they work correctly. If required, activate automatic closing and adjust the time with the TC trimmer. Set the obstacle thrust with the R1 trimmer. WARNING: check that the working forces exerted by the door wings are compliant with EN12453-EN12445 regulations. Connect any other accessories and check they operate correctly. NOTE: in the event of servicing or if the control panel is to be replaced, repeat the start-up procedure. 23 IP1839EN • 2012-07-31