Download User Manual
Transcript
048-3101 FHCS 2-56x3/8 5000312 048-3103 IH-170* *) IH-170 Not included with dummy purchase FHCS 2-56x5/16 Figure 12. String pot Side impact bracket Note: A spring is used to keep tension on the string potentiometer cable. When dismounting the string potentiometer from the rib, gently let the cable be reeled in by the spring. Releasing the cable while it is pulled out will cause serious damage the string potentiometer. Side Impacts 1. To use the string potentiometer for side impact, remove the string potentiometer caddy from the cavity in the thoracic spine. Remove the string potentiometer from its caddy. The string potentiometer can be used for left and right sided impacts by mounting the potentiometer on the right of left side. 2. Fasten the string potentiometer on the side impact caddy (048-3103) using the two imperial 2-56 screws. Note that the 2-56 x 3/8 screws are used at the top, while a shorter 2-56 x 5/16 screw is used at the bottom hole. 3. Attach the caddy to the thoracic spine, using the two M3 x 20 SHCS screws. 4. Pull out the string towards the rib, and put the ball in the socket of the string potentiometer attachment. 5. Insert the screw though the rib and fasten the string potentiometer attachment to the rib cage assembly. 6. To remove the string potentiometer, perform steps 2-4 in reverse order and fasten the string potentiometer attachment to the rib. 4.5 Lumbar Spine Construction The lumbar spine consists of lumbar spine central molding cable assembly load cell structural replacement screws (M5x12) 036-9900 User Manual Q1 (Advanced 1 year old child) Rev E © 2011 Humanetics Innovative Solutions Page 30 of 67