Download Product Reference Manual
Transcript
REFERENCES 5.7 COMMON RADIO PARAMETERS 5.7.1 Radio Protocol Timeout This parameter sets the valid time to wait before transmission between the ® Gryphon™ BT reader and the OM-Gryphon™ BT or remote Bluetooth device is considered failed. This parameter should be set taking into consideration the radio traffic or cradle transmission speed. It can be set between 3 and 19 seconds. 5.7.2 Transmission Retry This parameter allows setting a period of time in which transmission of the previously read barcode will automatically be retried. If not disabled (00), this value must be at least equal to double the Radio Protocol Timeout value (see par. 5.7.1). Each time transmission is retried, the reader emits a beep tone lower than the "Good Decode" beep tone. Transmission retry is always valid for communication with OM-Gryphon™ BT. It is valid for communication with BT devices only if ACK/NACK Protocol is enabled (see par. 5.8.1). 5.7.3 Power-Off Timeout If this command is enabled, after the desired timeout in hours, the Gryphon™ BT batteries are disconnected and all power consumption ceases. To restore power, press the trigger once. The reader will now be ready to read codes. Power-off does not effect configuration parameters. 5.7.4 Beeper Control for Radio Response The data entry good read tone normally results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether the remote Bluetooth® device has received the data. This can be changed according to the following selections: ♦ ♦ Good Decode and Good Reception: both good decode and good reception are signaled (two beeps). Only Good Decode: only the first beep indicating a good read is signaled. 149