Download FX3U-ENET USER`S MANUAL
Transcript
9 WHEN COMMUNICATING DATA USING THE MC PROTOCOL MELSEC-F Number of device points Head device (Data name) PLC side Complete code H L H - - L H - - - - - - - - - - L H L 0 0 F F 0 0 0 A 4 D 2 0 0 0 0 0 0 0 6 4 0 C 0 0 30H 30H 46H 46H30H 30H 30H 41H 34H44H 32H 30H 30H 30H 30H 30H 30H 30H 36H 34H 30H 43H 30H 30H Subheader (Example) Monitoring timer External device side PC No. (Data name) Subheader (2) Communication in ASCII code Data for the number of designed device points Characters for the number of device points H L H L H L H L H L H L H L 8 0 0 0 1 0 0 0 1 0 1 1 0 0 0 0 38H 30H 30H 30H 31H30H 30H 30H 31H 30H 31H 31H 30H 30H 30H 30H (Example) 8 0 0 0 1 0 0 0 1 0 1 1 0 0 0 0 38H 30H 30H 30H 31H 30H 30H 30H 31H 30H 31H 31H 30H 30H 30H 30H (80H) (00H) Status of M101 (OFF) Status of M100 (ON) Status of M103 (OFF) Status of M102 (OFF) Status of M105 (OFF) Status of M104 (ON) Status of M107 (ON) Status of M106 (ON) Status of M109 (OFF) Status of M108 (OFF) Status of M111 (OFF) Status of M110 (OFF) NOTE (1) (2) 9 - 20 Use the designation "00H" when the number of device points is 256 points. If the number of device points designated is an odd number, one byte of dummy data (30H) will be added to the response data. For example, if three points are read, data for four points is returned. The last byte is dummy data. 9 - 20