Download VBL3031_CB cert & report
Transcript
Page 72 of 79 Report No. 226382 www.nemko.com 5.3 TABLE: Fault condition tests P Ambient temperature (°C) .................................... 25°C, if nothing else specified ⎯ Power source for EUT: Manufacturer, For model BL10; CW20; VBL30; model/type, output rating ..................................... VBL31: APD AC/DC adapter type DA65C19: I/P: 1.6A, 100-240V, 50-60Hz, Cl.I O/P: 3.42A 19Vdc For model BL11: Delta AC/DC adapter type ADP90CD BB: I/P: 1.5A, 100-240V, 50-60Hz, Cl.I O/P: 4.74A 19Vdc ⎯ Component No. Fault Supply voltage (V) Test time Fuse # Fuse current (A) Observation Test on model BL10 DC fan Locked 19 2 hr -- -- Unit operated normally. Max. temp. of PCB near CPU=76.7˚C, Bottom enclosure near CPU =55.7˚C. Ambient=28.6˚C. Ventilation openings Blocked 19 2.5 hr -- -- Unit shutdown. Max. temp. of PCB near CPU=70.7˚C, Bottom enclosure near CPU =54.7˚C. Ambient=28.6˚C. Charger circuit in main board, test with Sony battery pack, type BATBLB3L61 Empty battery pack Charge Full battery pack Discharge 19 7 hr -- -- Charging current=3.16A. No damaged, no hazard. -- 7 hr -- -- Discharge current=5.23A No damaged, no hazard. Charger circuit in main board, test with Sony battery pack, type BATBLB3L62 Empty battery pack Charge Full battery pack Discharge 19 7 hr -- -- Charging current=3.66A. No damaged, no hazard. -- 7 hr -- -- Discharge current=5.19A. No damaged, no hazard. Charger circuit in main board, test with Sanyo battery pack, type BATAW20L61 Empty battery pack Charge Full battery pack Discharge TRF No. IEC60950_1C 19 7 hr -- -- Charging current=3.23A. No damaged, no hazard. -- 7 hr -- -- Discharge current=5.10A. No damaged, no hazard.