Page 74 Students Experiment Document. MOXA Experiment RX16. TU Dresden. Table 4-19: Description of 30-Byte Data Package (Downstream) SYNC SYNC MSGID MSGCNT DATA0..23 CRC CRC DATA0..15 CRC CRC Table 4-20: Description of 22-Byte Data Package (Upstream) SYNC SYNC MSGID MSGCNT A upstream command protocol will be used that allows setting of all elementary experiment parameters by remote, most significantly the status and control parameters, and allows remote triggering for the hatch and the sensors. 4.9.7 Control Loop An digital PID controller has been implemented to control the heating. The process parameters are flexible and can be adjusted before launch. For good performance the control route parameters are determined experimentally and will then be used to establish the PID parameters using an analytic model with SIMULINK software. fig. 46: Analytic Simulink Model of the Heating with quasi-continuous PID controller 4.9.8 Ground Station Software Design The ground station will be used to survey and save the received measurement data. The ground station software is developed in Java language. To access serial features, the RXTX Library will be used. For visualisation the open JFreeChart library is used. All commands can be executed by sending an ASCII Code through a serial interface. Start/Stop Heating Start/Stop Sensors Set Experiment Parameters (Control Parameters) Start/Stop Battery Read/Save all Analog Values (Currents, Voltages, Pressures) Read/Save all Temperature Values