Download CC-Link Network Monitor Function Sample Screen Manual
Transcript
CC-Link Network Monitor Function
Sample Screen Manual
Mitsubishi Electric Corporation
Using the Samples
The sample screen data and files such as the instruction manual can be used
upon agreement to the following matters.
(1) This data is available for use by customers currently using or considering use
of Mitsubishi products.
(2) The intellectual property rights of the files provided by Mitsubishi (hereinafter
referred to as the "Files") belong to Mitsubishi.
(3) Alteration, reproduction, transfer, or sales of the Files is prohibited.
This does not apply when the content, in part or full, is used for Mitsubishi
products incorporated in a device or system created by the customer.
Furthermore, this does not apply to the transfer, reproduction, reference, or
change of layout in the specifications, designs, or instruction manuals of
built-in products prepared by the customer using Mitsubishi products.
(4) Mitsubishi will not be held liable for any damages resulting from the use of the
Files or the data extracted from the Files. The customer is responsible for all
use.
(5) If any usage conditions are appended to the Files, those conditions must be
observed.
(6) The Files may be deleted or the contents changed without prior notice.
(7) When using the Files, please always read the corresponding manuals and
related manuals indicated therein. Please pay special attention to safety, and
correctly handle the product.
2/30
BCN-P5999-0111
CONTENTS
CONTENTS ........................................................................................................................................................ 3
REVISIONS ........................................................................................................................................................ 4
1.
OUTLINE ..................................................................................................................................................... 5
2.
SYSTEM CONFIGURATION ....................................................................................................................... 5
3.
GOT ............................................................................................................................................................. 5
4.
5.
3.1
System Applications That Are Automatically Selected .......................................................................... 5
3.2
Controller Setting of Screen Design Software....................................................................................... 5
CC-LINK MODULE (Q SERIES) .................................................................................................................. 6
4.1
PLC Engineering Software Network Parameter Setting ........................................................................ 6
4.2
Network Parameter Station Information Settings .................................................................................. 6
SCREEN SPECIFICATIONS ....................................................................................................................... 7
5.1
Display Language ................................................................................................................................. 7
5.2
Screen Transition .................................................................................................................................. 7
5.3
Explanation of Screens ......................................................................................................................... 9
5.3.1 Menu (B-30001) ................................................................................................................................ 9
5.3.2 CC-Link Diagnostics (B-30002) ....................................................................................................... 10
5.3.3 Station Status Monitor1 (B-30003), Station Status Monitor2 (B-30004) ........................................... 12
5.3.4 Network Status Display (Utility Function "Monitor") ......................................................................... 13
5.3.5 Manual Display-Language 1 (B-30500), Language 2 (B-30501), Language 3 (B-30502) ............... 15
5.3.6 Alarm Reset (W-30001)................................................................................................................... 17
5.3.7 Language Setting (W-30002) .......................................................................................................... 18
5.3.8 Clock Setting (W-30003) ................................................................................................................. 19
6.
5.4
Device List .......................................................................................................................................... 20
5.5
Comment List...................................................................................................................................... 21
5.6
Script List ............................................................................................................................................ 21
MANUAL DISPLAY .................................................................................................................................... 25
6.1
Preparing Document Data for Manual Display .................................................................................... 25
6.2
Changing the Total Number of Document Pages ................................................................................ 26
6.3
Setting the [Manual Display] Switch .................................................................................................... 28
7.
TEMPLATES .............................................................................................................................................. 29
8.
OTHERS .................................................................................................................................................... 30
8.1
System Configuration ......................................................................................................................... 30
8.2
Network Parameter Settings ............................................................................................................... 30
8.3
Precautions ......................................................................................................................................... 30
3/30
BCN-P5999-0111
REVISIONS
Sample Screen Manual
Date
Control No.*
2013/10
BCN-P5999-0111
Description
First edition
* The Control No. is noted at the lower right of each page.
Project data
Date
2013/10
Project data
CC-Link_V_Ver1_E.GTX
GT Designer3*
1.100E
First edition
Description
* The version number of screen design software used to create the project data is listed. Please use the
screen design software with the listed version or later.
4/30
BCN-P5999-0111
1. OUTLINE
This manual explains the sample screens for displaying the CC-Link network status (e.g., host station, other
stations, and errors) on GOT2000.
2. SYSTEM CONFIGURATION
<Intelligent device station>
GOT2000
GT27**-V (640 x 480)
Interface: Extend I/F-1
SD card *1
Battery (GT11-50BAT) *2
<Master station>
Q06UDEHCPU
QJ61BT11N
CC-Link communication unit
(GT15-J61BT13)
CC-Link cable *3
*1: The SD card is used for the document display function.
*2: The battery is used for the backup of the clock data. (The battery is provided with the GOT as standard.)
*3: For more details about the cable, please refer to the "GOT2000 Series Connection Manual (Mitsubishi
Products)".
*
The CC-Link network monitor function sample screens can also be used when the GOT is connected to
the master station or local station PLCs via serial connection or bus connection. For more details, please
refer to "8. OTHERS".
3. GOT
3.1 System Applications That Are Automatically Selected
Type
Standard Function
Communication Driver
Extended Function
System application name
Standard System Application
Standard Font
Japanese
CC-Link Ver. 2 (ID)
Standard Font
Chinese (Simplified)
Alphanumeric/Kana
Outline Font Gothic
Japanese (Kanji)
Chinese (Simplified)
Document Display
3.2 Controller Setting of Screen Design Software
Item
Station No.
Transmission Rate
Mode
Expanded Cyclic
Occupied Station
Input for Error Station
Retry (Times)
Timeout Time (Sec)
Delay Time (ms)
Set value
Remarks
1
4: Online: 10 Mbps
Ver. 2
Single
1 station occupied
Clear
3
3
0
5/30
BCN-P5999-0111
4. CC-LINK MODULE (Q SERIES)
4.1 PLC Engineering Software Network Parameter Setting
Item
No. of boards in module
Start I/O No.
Operation setting
Type
Mode
All connect count
Retry count
Automatic reconnection station unit
Stand by master station No.
PLC down select
Scan mode setting
Delay information setting
Station information setting
Remote device station initial settings
Interrupt setting
Set value
1
0000H
Use default value
Master station
Remote net Ver. 2 mode
1
Remarks
Use default value
Refer to 4.2
Use default value
4.2 Network Parameter Station Information Settings
Item
Station type
Expanded cyclic setting
Exclusive station count
Remote station points
Reserve/invalid station select
Intelligent buffer select (word)
Set value
Ver. 2 intelligent device station
Single
Exclusive station 1
32 points
No setting
Use default value
6/30
Remarks
Same setting as GOT
Same setting as GOT
BCN-P5999-0111
5. SCREEN SPECIFICATIONS
5.1 Display Language
The language of the text displayed on the screen can be switched between Japanese, English, and Chinese
(Simplified). The text strings in each language are registered in the columns No. 1 to No. 3 in the comment
group No. 255 as shown below. When the column No. is set in the language switching device, the language
corresponding to the column No. will appear.
Column No.
Language
1
English
2
Japanese
3
Chinese (Simplified)
5.2 Screen Transition
5.2.1 Screen transition (common)
Window screen W-30003:
Clock Setting
Window screen W-30002:
Language Setting
System Alarm
Base screen
(B-30001 Menu and other base screens)
Window screen W-30001: Alarm Reset
7/30
BCN-P5999-0111
5.2.2
Screen transition (individual)
Base screen B-30002: CC-Link Diagnostics
Base screen B-30003: Station Status Monitor1
Base screen B-30004: Station Status Monitor2
Base screen B-30001: Menu
Base screen B-30500:
Manual Display-Language 1
Base screen B-30501:
Manual Display-Language 2
Utility function Monitor:
Network Status Display
Base screen B-30502:
Manual Display-Language 3
8/30
BCN-P5999-0111
5.3 Explanation of Screens
5.3.1 Menu (B-30001)
6
7
1
4
2
5
3
Outline
This is the Menu screen.
Description
1. Switches to the [CC-Link Diagnostics] screen.
2. Switches to the [Station Status Monitor1] screen.
3. Switches to the [Station Status Monitor2] screen.
4. Switches to the [Network Status Display] screen.
5. Switches to the [Manual Display] screen.
6. Displays the current date and time. Touch the area to open the [Clock Setting] window.
7. Opens the [Language Setting] window.
Remarks
The [Manual Display] switch allows switching to the [Manual Display] screen of the currently
displayed language.
The currently open window closes when the screen is switched.
If a system alarm occurs, the alarm message will appear at the bottom of the screen. Touch the
alarm message to open the [Alarm Reset] window.
9/30
BCN-P5999-0111
5.3.2 CC-Link Diagnostics (B-30002)
7
8
1
2
3
4
5
6
Outline
This screen allows checking the CC-Link network status (host station and other stations).
Description
1. Allows the network status of the host station to be checked.
Host parameter mode
: Displays the parameter mode.
Host station number
: Displays the station No.
Master station information
: Displays which of the master stations and standby master
stations is used for data link control.
Max. link scan time
: Displays the maximum value of link scan time.
Min. link scan time
: Displays the minimum value of link scan time.
Current link scan time
: Displays the current value of link scan time.
2. Allows the network status of other stations to be checked.
Data link status
: OFF = All stations normal; ON = A faulty station exists
Reserved station specified status
: OFF = Not specified; ON = Specified
Error invalid station specified status
: OFF = Not specified; ON = Specified
Temp. error invalid station setting info. : OFF = Not set; ON = Set
Transient transmission status
: OFF = No error; ON = Error
Watchdog timer error status
: OFF = No error; ON = Error
Fuse blown status
: OFF = No error; ON = Error
Switch change status
: OFF = No change; ON = Changed
3. Allows the network test for the host station to be executed and the test results to be checked.
Data link stop result
: Displays the execution result of the data link stop command.
0 = Normal; Other than 0 = An error code is stored
Data link restart result
: Displays the execution result of the data link restart command.
0 = Normal; Other than 0 = An error code is stored
Data Link Stop
: Stops the data link of the host.
Data Link Restart
: Restarts the data link of the host.
4. Switches to each screen. The blue switch indicates the currently displayed screen, thus selecting
this switch will not switch the screen.
5. Shows unused switches for base screen switching.
6. Switches to the previously opened screen.
10/30
BCN-P5999-0111
7.
8.
Displays the current date and time. Touch the area to open the [Clock Setting] window.
Opens the [Language Setting] window.
Remarks
The device shown by the host station differs depending on the connection method.
GOT is connected via CC-Link connection: GOT
GOT is connected to the master station or local station via serial connection or bus connection:
Connected master station or local station
For the data link stop result and data link restart result error codes described in 3, please refer to the
"MELSEC-Q CC-Link System Master/Local Module User's Manual".
The [Manual Display] switch allows switching to the [Manual Display] screen of the currently
displayed language.
The currently open window closes when the screen is switched.
If a system alarm occurs, the alarm message will appear at the bottom of the screen. Touch the
alarm message to open the [Alarm Reset] window.
11/30
BCN-P5999-0111
5.3.3 Station Status Monitor1 (B-30003), Station Status Monitor2 (B-30004)
6
7
1
2
3
4
5
Outline
This screen allows the detailed status of each station to be checked. (Stations 1 to 32: Base screen
B-30003 Station Status Monitor1; Stations 33 to 64: Base screen B-30004 Station Status Monitor2)
Description
1. Displays the following setting statuses.
Reserved station specification
: OFF = Other than the reserved station; ON = Reserved station
Error invalid station specification : OFF = Other than the error invalid station; ON = Error invalid
station
Status
: Refer to 2.
Transient transmission error
: OFF = No error; ON = Error
2. Displays the statuses in the following order of priority.
1. Temporary error invalid
: OFF = Normal state; ON = Temporary error invalid state
2. Data link error
: OFF = Normal; ON = Data link error
3. WDT error
: OFF = No watchdog timer error; ON = Watchdog timer error
4. Fuse blown error
: OFF = Normal; ON = Error
5. Switch changed
: OFF = No switch change on other stations during data link;
ON = Switch changed on other stations during data link
3. Switches to each screen. The blue switch indicates the currently displayed screen, thus selecting
this switch will not switch the screen.
4. Shows unused switches for base screen switching.
5. Switches to the previously opened screen.
6. Displays the current date and time. Touch the area to open the [Clock Setting] window.
7. Opens the [Language Setting] window.
Remarks
The [Manual Display] switch allows switching to the [Manual Display] screen of the currently
displayed language.
The currently open window closes when the screen is switched.
If a system alarm occurs, the alarm message will appear at the bottom of the screen. Touch the
alarm message to open the [Alarm Reset] window.
12/30
BCN-P5999-0111
5.3.4 Network Status Display (Utility Function "Monitor")
4
2
1
3
Outline
This window allows the LED status and error information of the equipped CC-Link communication
module (GT15-J61BT13) to be checked.
Description
1. Displays an LED status of the CC-Link communication module (GT15-J61BT13).
RUN
: Not lit = WDT error occurred or unit being reset; Lit in green = Running normally
ERR
: Not lit = No communication error occurred or unit being reset; Lit in red = All station
communication error
Blink = There is a communication error station or duplicated station numbers
MST
: Not lit = Operating other than as master station; Lit in green = Operating as master
station
S MST
: Not lit = Operating other than as standby master station; Lit in green = Operating as
standby master station
LOCAL
: Not lit = Operating other than as local station; Lit in green = Operating as local station
SW
: Not lit = No switch setting error; Lit in red = Switch setting error
M/S
: Not lit = No duplicate master station error; Lit in red = Duplicate master station error
PRM
: Not lit = No parameter error; Lit in red = Parameter error
TIME
: Not lit = Responses from all stations;
Lit in red = No responses from all stations due to cable breakage or transmission
path affected by noise
LINE
: Not lit = No cable breakage error; Lit in red = Cable breakage error
GOT R/W : Not lit = Not accessed from GOT; Lit in green = Accessed from GOT
2. Displays the data link startup status.
D-Link in prog.
: Data link being executed
D-Link Offline
: Data link being stopped
Initialize
: Set to the initial status
Parameter wait
: Parameter not received
Disconnect (No Polling)
: In cut-off status with no inquiry from master station
Disconnect (Line Err)
: In cut-off status due to line error
Disconnect (Other)
: In cut-off status due to other causes
Testing Line
: Line test being executed
Testing Param Setup
: Parameter setting test being executed from master
13/30
BCN-P5999-0111
Auto Reconnecting
Reset. in prgr.
3.
4.
Displays the status of the current error.
Normal
Invalid TransPath
Invalid Parameter
CRC Error
Time Out Error
Abort Error
Invalid Setup
Other Abnormality
Closes the screen.
station
: Return processing being executed automatically
: CC-Link communication unit being reset (GOT reset
status)
: Normal status
: Transmission path error detected
: Parameter error detected
: Reception data error detected
: Timeout error detected in data reception
: Error detected in data communication
: Invalid station number, station type, transmission speed,
or mode setting detected
: Error due to some other cause detected
Remarks
For more details about how to troubleshoot errors that occur in the CC-Link, please refer to the
"MELSEC-Q CC-Link System Master/Local Module User's Manual".
When the GOT is connected to the master station or local station via serial connection or bus
connection, the network status display cannot be used.
14/30
BCN-P5999-0111
5.3.5 Manual Display-Language 1 (B-30500), Language 2 (B-30501), Language 3 (B-30502)
7
8
1
2
3
4
5
6
Outline
This screen displays the manual of the currently displayed language.
Description
1. The documents with Document IDs 201 to 203 are displayed in the [Manual Display - Language 1
(B-30500)] to [Manual Display - Language 3 (B-30502)] screens. The page 1 is displayed when the
screen is initially displayed. While touching the document, flicking to 8 directions will scroll the
document to 8 directions. While displaying the edge of the document, flicking the document will
switch pages. Pinching out and in will zoom in and out the document in 3 steps (large, middle, and
small).
2. These switches operate the displayed document.
: Enlarges or reduces the displayed document.
: Scrolls the displayed document to the left or right.
: Scrolls the displayed document up and down.
3. These switches operate the displayed document page.
: Displays the page number of the displayed document. Touch the value to change the
page number.
: Switches to the previous or next page of the displayed document.
4. Switches to each screen. The blue switch indicates the currently displayed screen, thus selecting
this switch will not switch the screen.
5. Shows unused switches for base screen switching.
6. Switches to the previously opened screen.
7. Displays the current date and time. Touch the area to open the [Clock Setting] window.
8. Opens the [Language Setting] window.
15/30
BCN-P5999-0111
Remarks
The language of the manual should be the same as the language of the document that will be
prepared for the manual. The language of the title and the text on touch switches (other than the
manual display area) is the same as the language of comments specified in the columns No. 1 to
No. 3 in the comment group No. 255. The relation of the document (Document ID) and the column
No. in the comment group No. 255 is shown below.
Base screen
Document ID
Column No.
Manual Display-Language 1 (B-30500)
201
1
Manual Display-Language 2 (B-30501)
202
2
Manual Display-Language 3 (B-30502)
203
3
When the GOT is started, the document page No. is set to 1 by the project script. For more details
about scripts, please refer to "5.6 Script List".
The document data for the manual display should be prepared by the customers. For more details,
please refer to "5. MANUAL DISPLAY".
The currently open window closes when the screen is switched.
If a system alarm occurs, the alarm message will appear at the bottom of the screen. Touch the
alarm message to open the [Alarm Reset] window.
16/30
BCN-P5999-0111
5.3.6 Alarm Reset (W-30001)
2
1
Outline
This window screen allows resetting the system alarm.
Description
1. Resets the system alarm, and closes the window screen after 1 second.
2. Closes the window screen.
Remarks
17/30
BCN-P5999-0111
5.3.7 Language Setting (W-30002)
2
1
Outline
This window screen allows selecting the GOT language.
Description
1. Switches the language, and closes the window screen.
2. Closes the window screen.
Remarks
The system language is also switched according to the display language.
While the base screen is one of the screens of [Manual Display - Language 1] to [Manual Display Language 3], if the language is switched in the [Language Setting] window, the screen script will
change the manual display screen according to the language selected in this screen. For more
details about scripts, please refer to "4.6 Script List".
18/30
BCN-P5999-0111
5.3.8 Clock Setting (W-30003)
4
1
2
3
Outline
This window screen allows changing the GOT clock data.
Description
1. Displays the current date and time.
2. Use
switches to change the date and time. Hold down the switches to increment or
decrement the value continuously. The [Reset] switch resets the seconds.
3. Applies the set date and time to the GOT clock data, and closes the window screen after 1 second.
4. Closes the window screen.
Remarks
The date and time at window opening are initially set as the clock data to be newly set.
Object scripts are set for the numerical display of the year, month, date, hour, minute and second in
the clock data to be newly set. For more details about scripts, please refer to "5.6 Script List".
19/30
BCN-P5999-0111
5.4 Device List
Some of the devices specified for the on-screen switches, lamps, or others are also used for common settings
of functions such as scripts. Using [Batch Edit] is recommended to change these devices in a batch. For more
details about using [Batch Edit], please refer to the "GT Designer3 (GOT2000) Help".
5.4.1 Devices of the controller
Type
Device No.
SB0000
SB0002
SB0070
SB0074
SB0075
SB0076
SB0080
SB0081
SB0082
SB0083
Bit
SB0094
SW0074.b0 to SW0077.b15
SW0078.b0 to SW007B.b15
SW007C.b0 to SW007F.b15
SW0080.b0 to SW0083.b15
SW0084.b0 to SW0087.b15
SW0088.b0 to SW008B.b15
SW008C.b0 to SW008F.b15
SW0094.b0 to SW0097.b15
SW0041
SW0045
SW0061
Word SW006D
SW006E
SW006F
SW0149
Application
Data Link Restart
Data Link Stop
Master Station Info_Contents
Reserved Sta. Status_Contents
Err Inv. Sta. Status_Contents
Temp. Err Inv. Sta. Status_Contents
Data Link Status_Contents
WDT Error Status_Contents
Fuse Blown Status_Contents
Switch Setting Status_Contents
Transient Tx Status_Contents
Reserved Station_01 to 64
Error Invalid_01 to 64
Status_01 to 64 (Temporary Error Invalid)
Status_01 to 64 (Data Link Status)
Status_01 to 64 (WDT Error Status)
Status_01 to 64 (Fuse Blown Status)
Status_01 to 64 (Switch Change Status)
Transient Error_01 to 64
Data Link Restart Result_Value
Data Link Stop Result_Value
Host Station No._Value
Max. Link Scan Time_Value
Current Link Scan Time_Value
Min. Link Scan Time_Value
Host Parameter Mode_Contents
5.4.2 GOT internal devices
Type
Device No.
GB40
Bit
Word
GD60031.b13
GS512.b0
GD60000
GD60001
GD60004
GD60021
GD60022
GD60031,
GD60041
GD60080 to
GD60082
GD61000
GD63990 to
GD63995
GS513 to GS516
Application
Script Trigger (Always ON)
Legend of B-30003 and 30004
GOT Error Reset Signal
Time Change Signal
Base Screen Switching
Overlap Window 1 Screen Switching
Overlap Window 2 Screen Switching
Language Switching
System Language Switching
System Information
Document Display Page No. Device
Word Lamp of B-30003 and 30004
Clock Digital Switch
Changed Time
20/30
BCN-P5999-0111
Type
Device No.
Application
Word
GS650 to GS652
TMP950 to TMP996
Current Time
For Script Operation
5.5 Comment List
Comment group No.
255
Comment No.
No. 1
No. 2
No. 3 to No. 5
No. 6
No. 7 to No. 12
No. 21 to No. 55
No. 61 to No. 72
No. 81, No. 82
No. 83
No. 84 to No. 91
Where comments are used
B-30001 to B-30502
B-30001, B-30002
B-30001
B-30001, B-30500 to B-30502
B-30002 to B-30502
B-30002
B-30003, B-30004
W-30001
W-30002
W-30003
5.6 Script List
Item
Setting
Project Script
Specified
Screen Script
Specified: W-30002
Object script
Specified: W-30003
5.6.1 Project script
Script No.
30001
Script name
Script30001
Comment
Initial Setting
Data type
Signed BIN16
Trigger type
Rise, GB40
[w:GD60080]=1;
//Set 1 to Document Page No. of Base Screen 30500
[w:GD60081]=1;
//Set 1 to Document Page No. of Base Screen 30501
[w:GD60082]=1;
//Set 1 to Document Page No. of Base Screen 30502
5.6.2 Screen script
Window screen W-30002
Script No.
30002
Script name
Script30002
Comment
Lang. Switching for Man. Display
Data type
Signed BIN16
Trigger type
When closing a screen
if(([w:GD60000] >= 30500) && ([w:GD60000] <= 30502)){ //Base Screen Switching Device Value
30500 to 30502
if([w:GD60021] <= 1){
//In Case of Language 1
[w:GD60000] = 30500;
//Manual Display - Move to Language 1 Screen
}
if([w:GD60021] == 2){
//In Case of Language 2
[w:GD60000] = 30501;
//Manual Display - Move to Language 2 Screen
}
if([w:GD60021] == 3){
//In Case of Language 3
[w:GD60000] = 30502;
//Manual Display - Move to Language 3 Screen
}
}
21/30
BCN-P5999-0111
5.6.3 Object script
Window screen 30003
Object (Name)
Numerical display (Change_Year)
Script user ID
1
Data type
Unsigned BIN16
Trigger type
Rise, GB40
//Obtain Today's Year & Month from Clock Data
[w:TMP950] = [w:GS650] & 0xF000;//Obtain Tenths Digit of "Last 2-Digits of Year" from Clock Data
for Setting
[w:TMP960] = [w:TMP950] >> 12;//Decimal Alignment
[w:TMP968] = [w:TMP960] * 10;//BCD->BIN
[w:TMP951] = [w:GS650] & 0x0F00;//Obtain Ones Digit of "Last 2-Digits of Year" from Clock Data for
Setting
[w:TMP961] = [w:TMP951] >> 8;//BCD->BIN
[w:TMP973] = 2000 + [w:TMP968] + [w:TMP961];//Set Year to TMP973 as BIN
[w:GD63990] = [w:TMP973];//Set Year
[w:TMP952] = [w:GS650] & 0x00F0;//Obtain Tenths Digit of Month from Clock Data for Setting
[w:TMP962] = [w:TMP952] >> 4;//Decimal Alignment
[w:TMP969] = [w:TMP962] * 10;//BCD->BIN
[w:TMP953] = [w:GS650] & 0x000F;//Obtain Ones Digit of Month from Clock Data for Setting
[w:TMP974] = [w:TMP969] + [w:TMP953];//Set Month to TMP974 as BIN
[w:GD63991] = [w:TMP974];//Set Month
[w:TMP954] = [w:GS651] & 0xF000;//Obtain Tenths Digit of "Last 2-Digits of Day" from Clock Data for
Setting
[w:TMP963] = [w:TMP954] >> 12;//Decimal Alignment
[w:TMP970] = [w:TMP963] * 10;//BCD->BIN
[w:TMP955] = [w:GS651] & 0x0F00;//Obtain Ones Digit of "Last 2-Digits of Day" from Clock Data for
Setting
[w:TMP964] = [w:TMP955] >> 8;//BCD->BIN
[w:TMP975] =[w:TMP970] + [w:TMP964];//Set Day to TMP975 as BIN
[w:GD63992] = [w:TMP975];//Set Day
[w:TMP956] = [w:GS651] & 0x00F0;//Obtain Tenths Digit of Hour from Clock Data for Setting
[w:TMP965] = [w:TMP956] >> 4;//Decimal Alignment
[w:TMP971] = [w:TMP965] * 10;//BCD->BIN
[w:TMP957] = [w:GS651] & 0x000F;//Obtain Ones Digit of Hour from Clock Data for Setting
[w:TMP976] = [w:TMP971] + [w:TMP957];//Set Hour to TMP976 as BIN
[w:GD63993] = [w:TMP976];//Set Hour
[w:TMP958] = [w:GS652] & 0xF000;//Obtain Tenths Digit of "Last 2-Digits of Minute" from Clock Data
for Setting
[w:TMP966] = [w:TMP958] >> 12;//Decimal Alignment
[w:TMP972] = [w:TMP966] * 10;//BCD->BIN
[w:TMP959] = [w:GS652] & 0x0F00;//Obtain Ones Digit of "Last 2-Digits of Minute" from Clock Data
for Setting
[w:TMP967] = [w:TMP959] >> 8;//BCD->BIN
[w:TMP977] =[w:TMP972] + [w:TMP967];//Set Minute to TMP977 as BIN
[w:GD63994] = [w:TMP977];//Set Minute
[w:TMP993] = [w:GS652] & 0x00F0;//Obtain Tenths Digit of Second from Clock Data for Setting
[w:TMP995] = [w:TMP993] >> 4;//Decimal Alignment
[w:TMP996] = [w:TMP995] * 10;//BCD->BIN
[w:TMP994] = [w:GS652] & 0x000F;//Obtain Ones Digit of Second from Clock Data for Setting
[w:TMP978] = [w:TMP996] + [w:TMP994];//Set Second to TMP978 as BIN
[w:GD63995] = [w:TMP978];//Set Second
22/30
BCN-P5999-0111
Object (Name)
Numerical display (Change_Month)
Script user ID
2
Data type
Unsigned BIN16
Trigger type
//BIN -> BCD Conversion
Ordinary
[w:TMP979] = [w:GD63990] - 2000; //Last 2-Digits of Year
[w:TMP980] = (([w:TMP979] / 10) << 4) + ([w:TMP979] % 10); //Year BIN -> BCD
[w:TMP981] = (([w:GD63991] / 10) << 4) + ([w:GD63991] % 10); //Month BIN -> BCD
[w:TMP982] = (([w:GD63992] / 10) << 4) + ([w:GD63992] % 10); //Day BIN -> BCD
[w:TMP983] = (([w:GD63993] / 10) << 4) + ([w:GD63993] % 10); //Hour BIN -> BCD
[w:TMP984] = (([w:GD63994] / 10) << 4) + ([w:GD63994] % 10); //Minute BIN -> BCD
[w:TMP985] = (([w:GD63995] / 10) << 4) + ([w:GD63995] % 10); //Second BIN -> BCD
Object (Name)
Numerical display (Change_Day)
Script user ID
3
Data type
Unsigned BIN16
Trigger type
//Year & Month Setting
Ordinary
[w:GS513] = ([w:TMP980] << 8) + [w:TMP981]; //Set Year & Month to Change Time Device
Object (Name)
Numerical display (Change_Hour)
Script user ID
4
Data type
Unsigned BIN16
Trigger type
//Date & Time Setting
Ordinary
[w:GS514] = ([w:TMP982] << 8) + [w:TMP983]; //Set Date & Time to Change Time Device
Object (Name)
Numerical display (Change_Minute)
Script user ID
5
Data type
Unsigned BIN16
Trigger type
//Minute & Second Setting
Ordinary
[w:GS515] = ([w:TMP984] << 8) + [w:TMP985]; //Set Minute & Second to Change Time Device
23/30
BCN-P5999-0111
Object (Name)
Numerical display (Change_Second)
Script user ID
6
Data type
Unsigned BIN16
Trigger type
//Day of Week Setting
Ordinary
[w:TMP986] = [w:GD63990]; //Year (BIN)
[w:TMP987] = [w:GD63991]; //Month (BIN)
[w:TMP988] = [w:GD63992]; //Day (BIN)
if(([w:TMP987] == 1) || ([w:TMP987] == 2)){// Correction Processing to Calculate January and
February as 13th/14th Month
[w:TMP986] =[w:TMP986] - 1; //Subtract 1 from Year
[w:TMP987] =[w:TMP987] + 12;//Add 12 to Month
}
[w:TMP989] = [w:TMP986]/4;//Create Items Required for Zeller's Congruence
[w:TMP990] = [w:TMP986]/100;//Create Items Required for Zeller's Congruence
[w:TMP991] = [w:TMP986]/400;//Create Items Required for Zeller's Congruence
[w:TMP992] = (13*[w:TMP987]+8)/5;//Create Items Required for Zeller's Congruence
//Calculate Day of Week Using Zeller's Congruence and Set the Day to Change Time Device
[w:GS516] = ([w:TMP986]+[w:TMP989]-[w:TMP990]+[w:TMP991]+[w:TMP992]+[w:TMP988])%7;
24/30
BCN-P5999-0111
6. MANUAL DISPLAY
Manuals can be displayed using the document display function. For more details about the document display
function, please refer to the "GT Designer3 (GOT2000) Help". Please note that the document display function
does not support language switching. Therefore, in the sample screens, the languages of the manual are
switched by switching to the base screen to which the document (Document ID) of the selected language is
specified.
6.1 Preparing Document Data for Manual Display
Example: Displaying a manual (document) on the base screen B-30500: Manual Display - Language 1
(1) Convert the manual (including Word and Excel) to be displayed into the document data (JPEG file) that
can be used with the document display function by using Document Converter. Set the Document
Converter's [Document ID] to the same value as the base screen B-30500 document display [Document
ID].
Document Converter's
Document ID
Example: Document ID of the document display
in the base screen B-30500: Manual Display Language 1
(2) The document data is generated in the 201 folder in the DOCIMG. Save the entire DOCIMG folder into the
SD card root directory without changing the folder configuration inside the DOCIMG folder.
Document ID
SD card folder configuration
25/30
BCN-P5999-0111
6.2 Changing the Total Number of Document Pages
Change the total number of pages at the lower right of the screen according to the total page number of the
document to be displayed.
Example: To change the total number of document pages from 10 pages to 20 pages.
(1) Change the format string of numerical input.
(2) Change the input range of numerical input.
(3) Change the next page switch setting.
(1) Change the format of the numerical input.
1. Double-click the numerical input, and open the [Device] tab on the dialog box.
2. Change the [Format String] from "P.##/10" to "P.##/20".
P.##/20
26/30
BCN-P5999-0111
(2) Change the input range of the numerical input.
1. Open the [Input Range] tab in the dialog box.
2. Click on [Exp...], and open the [Edit Range] dialog box.
3. Change the constant from 10 to 20.
20
(3) Change the next page switch setting.
1. Open the [Action] tab on the dialog box.
2. Double-click [Action 1], and open the [Action (Word)] dialog box.
3. Change the [Condition Value] and [Reset Value] from 10 to 20.
20
20
27/30
BCN-P5999-0111
6.3 Setting the [Manual Display] Switch
The [Manual Display] switch specifies the manual screen to be displayed according to the Column No. stored
in the language switching device. For more details about the Column No., please refer to "5.1 Display
Language".
Language switching device
28/30
BCN-P5999-0111
7. TEMPLATES
Templates are a group of figures and objects. Related settings are grouped into template attributes and
registered, so the devices, colors, and other items can be easily changed in a batch. For more details about
changing the attribute settings, please refer to "GT Designer3 (GOT2000) Help".
Template information
The template information is only displayed on the screen design software's editing screen. It is not
displayed on the GOT display screen.
Example: Changing a font
(1) Select [Template Information], and click on [Template Property] (or double-click on [Template
Information]).
The figures and objects that are registered in the template are
changed to the selected state.
(2) Click [Font], and select the new font.
29/30
BCN-P5999-0111
8. OTHERS
The CC-Link network monitor function sample screens can also be used when the GOT is connected to the
master station or local station PLCs via serial connection or bus connection.
8.1 System Configuration
GOT2000
GT27**-V (640 x 480)
Interface: Depends on connection type
SD card *1
Battery (GT11-50BAT) *2
Communication unit
appropriate for the
connection type
<Master station/local station>
Q06UDEHCPU
QJ61BT11N
Communication
cable appropriate
for the connection
type *3
CC-Link cable *3
*1: The SD card is used for the document display function.
*2: The battery is used for the backup of the clock data. (The battery is provided with the GOT as standard.)
*3: For more details about the cable, please refer to the "GOT2000 Series Connection Manual (Mitsubishi
Products)".
8.2 Network Parameter Settings
To monitor the link special relay (SB) and link special register (SW) of the master station or local station PLCs
on the GOT, set the refresh device as follows in [CC-Link] of [Network Parameter] of the PLC engineering
software.
Item
Set value
Special relay (SB)
SB0
Special register (SW)
SW0
8.3 Precautions
The network status display cannot be used with the above system configuration.
30/30