Download User Manual - INTEC Controls
Transcript
PolyGard® Digital Gas Controller User Manual - DGC3 3.6.3 Page 16 Measuring Range The measuring range can be defined arbitrarily between 10 and 10000. The measuring ranges in the table gas type are only recommendations without obligation. The measuring range must agree with the range of the attached gas transmitter. 3.6.4 MP Signal Gas transmitters using electro-chemical or catalytic beat gas sensors normally produce a linear signal, proportional to the gas concentration. Semiconductor gas sensors produce a non-linear (exponential) signal due to their measuring principle. This signal leads to a non-linear output signal of the gas transmitter. The Gas Controller DGC3 is prepared for both types, for gas transmitters with linear signal as well as for analog transmitters with semiconductor sensor and non-linear signal. The signal type is defined in this menu. 3.6.5 Symbol Description MP 01 Measuring Point Linear MP Signal Setting Status Function Selection of MP No. Linear Linear = Transmitter with linear output signal Non linear = Transmitter with non-linear output signal Threshold / Hysteresis For each measuring point four alarm thresholds are available for free definition. If the gas concentration exceeds the adjusted alarm threshold, the associated alarm is set. If the gas concentration falls below the alarm threshold inclusive hysteresis the alarm is reset again. Unused alarm thresholds have to be defined with full scale value, in order to avoid false alarms. For O2 measurement: Pay attention to the alarm activation at decreasing or increasing concentration! Symbol Description 3.6.6 MP 01 Measuring Point 40 ppm Threshold Default Status 40 80 100 120 15 Function Threshold 1 Threshold 2 Threshold 3 Threshold 4 Hysteresis Selection MP No. Gas concentration > Threshold 1 = Alarm 1 Gas concentration > Threshold 2 = Alarm 2 Gas concentration > Threshold 3 = Alarm 3 Gas concentration > Threshold 4 = Alarm 4 Gas concentration < (Threshold X –Hysteresis) = Alarm X OFF Delay of Alarm ON or OFF Definition of alarm ON and/or alarm OFF delay. The function applies to all alarms of an MP. Default Status Symbol Description MP 01 Measuring Point 0s Delay Time ON 0s Delay Time OFF 0 0 Function Selection of MP No. Gas concentration > Threshold: Alarm is only activated at the end of the fixed time (sec.). 0 sec. = No Delay Gas concentration < Threshold: Alarm is only deactivated at the end of the fixed time (sec.). 0 sec. = No Delay The delayed activation of an existing gas alarm can cause damage to persons and objects. The commissioning technician and/or the operator are solely responsible for the activation. Polygard® is a registered trademark of MSR Customer Services (858) 578-7887 & (888) GO INTEC Fax (858) 578-4633 & (888) FX INTEC www.inteccontrols.com INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 DGC3 Specification subject to change without notice. Printed in USA 130917