Download C100 HDS Installation Guide
Transcript
Specifications Blackrock processor Parameter Condition Height Width Case only without rack ears Depth Weight (†) Heat Dissipation Voltage Current Power Factor Fusing Noise Connectors Range Maximum over voltage range Thermal current trip. No fuses Front Rear Power in 1 and 2 Networks Sync In Fibre I/O Value Unit 2 U 89 19 449 429 14 200 100 – 240 2.1 – 0.9 0.95 mm in mm mm kg W V A 50 55 NR NR IEC male RJ45 BNC 75Ω Duplex LC Notes Excludes connectors/cables Shared between two PSUs ±10%, 50/60Hz AC only Maximum Approximately Both PSUs powered Both PSUs powered Multimode or singlemode to order † Blackrock processor units must be supported on rack shelves. Do not rely on the rack ears alone. Rio Parameter Condition Height Width Case only without rack ears Depth Weight (†) Heat Dissipation Voltage Current Power Factor Fusing Noise Connectors 5 Mic cards 1 Mic, 2 analogue, 1 digital card Range Maximum over voltage range Thermal current trip. No fuses Front Rear Power in 1 and 2 Network Sync out Madi 1–4 GPI Input GPI Output Value Unit 7 U 665 19 449 344 17 – 21 500 350 100 – 240 5.6 – 2.3 0.95 mm in mm mm kg W W V A Notes Excludes connectors/cables Depending on I/O fitted Maximum Typical ±10%, AC only Approximately 45 – 55 NR Variable speed fans 45 – 60 NR IEC male RJ45 100 baseT (unused) BNC 75Ω (Wordclock) Duplex LC fibre multimode 25-way D-type male 25-way D-type female † RIO units must be supported on rack shelves. Do not rely on the rack ears alone. C100 HDS Installation Manual Section 4 – Appendices | Page 4-3