Download 55 The SDL Analyzer
Transcript
Environment Variables Environment Variables • SDTSAN_WARN_GATE By setting this to any value the analyzer will give warnings instead of errors for unconnected gates that should be connected. This option is only provided for backwards compatibility and should not be used if possible. • SDTSAN_ASN1_ENUM_OP By setting this to any value the analyzer will pass the -e option to asn1util. This will create all operators for ASN.1 ENUMERATED types as defined in Z.105. • SDTSAN_FILTER_USE By setting this to any value the analyzer will run the specified filter command specified in the analyzer options once before SDL package dependencies are resolved. This makes it possible for external filter scripts to exclude SDL package before make files are generated. Syntax of Analyzer Commands A command name may be abbreviated by giving sufficient characters to distinguish it from other command names. A hyphen (’-’) is used to separate command names into distinct parts. Any part may be abbreviated as long as the command does not become ambiguous. Parameters to commands are separated by one or several spaces. In case you omit a parameter of type “on/off”, the value currently defined will toggle between its “on” and “off” values. In both command names and parameters there is no distinction made between upper and lower case letters. Note: On UNIX systems, distinction is made between upper case letters and lower case letters for file names. July 2003 Telelogic Tau 4.5 User’s Manual ,um-st1 2405