Specifications
Model Number
NRG05–D240AC–4Q (-PCM)
Type
AC Line Voltage
Open Chassis
120 VAC or 240 VAC, ±10%, 50Hz or 60 Hz, single phase
Maximum Armature Current
5 ADC
Horsepower Range @ 130 VDC Output
1/8 – 3/4
Horsepower Range @ 240 VDC Output
1/4 – 1.5
Maximum Armature Voltage Range @ 120 VAC Input
0–130 VDC
Maximum Armature Voltage Range @ 240 VAC Input
0–240 VDC
Minimum Speed Adjustment Range @ 120 VAC Input
0–60 VDC
Minimum Speed Adjustment Range @ 240 VAC Input
0–120 VDC
Form Factor
1.05
Acceleration Time Range
0.1–20 seconds
Deceleration Time Range
0.1–20 seconds
Input Signal Range (signal must be isolated)**
– 10 to +10 VDC
Input Impedance
47k Ohm
Speed Regulation (% of base speed)
1% open loop; 0.1% tach feedback
Tachogenerator Voltage Output Range
Vibration
7V/1000 RPM to 50V/1000 RPM
0.5G max. (0–50 Hz); 0.1G max. (>50 Hz)
Weight
Ambient Operating Temperature Range*
1.9 lb
10°C–40°C
*External air flow is required to ensure temperature limits are not exceeded.
** (-PCM) drives do not require an isolated signal.