Report No. 130229
IEC 60335-2-15
Clause
Requirement + Test
15.3
Applicable for full disconnection and microdisconnection
N/A
17
Endurance
N/A
Compliance is checked on three separate appliances
or switches
N/A
For 17.2.4.4, the number of cycles is 10 000, unless
otherwise specified in 24.1.3 of the relevant part 2 of
IEC 60335
N/A
Switches for operation under no load and which can
be operated only by a tool and switches operated by
hand that are interlocked so that they cannot be
operated under load, are not subjected to the tests
N/A
Subclauses 17.2.2 and 17.2.5.2 not applicable
N/A
The ambient temperature during the test is that
occurring in the appliance during the test of Clause
11 in IEC 60335-1
N/A
Temperature rise of the terminals not more than 30 K
above the temperature rise measured in clause 11 of
IEC 60335-1
N/A
Clearances, creepage distances, solid insulation and coatings of rigid printed board
assemblies
N/A
This clause is applicable to clearances and creepage
distances for functional insulation, across full
disconnection and micro-disconnection, as stated in
table 24
N/A
20
I
Result - Remark
Verdict
ANNEX I (NORMATIVE)
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED
VOLTAGE OF THE APPLIANCE
The following modifications to this standard are
applicable for motors having basic insulation that is
inadequate for the rated voltage of the appliance:
N/A
8
Protection against access to live parts
N/A
8.1
Metal parts of the motor are considered to be bare
live parts
N/A
11
Heating
N/A
TRF No. IEC60335_2_15E