Bidders,
Reference: Bid no: BPC/ICSD/SDH-l/2K9- Supply, installation & commissioning ofSDH
equipment for establishing international gatewayand nodal bandwidth distribution points.
Subject: Amendment1 to the referred Tender
Dear Madam/Sir,
Pleasefind enclosedthe documentsconstitutingthe amendmentfor the referred tender:
The amendmentconsistsof the following:
Main Text of the Addendumincludingrevisedprice schedule
11.
Annexure -Reply to Queriesreceivedfrom Bidders
This amendmentwill form part of the tender document. Kindly make sure that the changes
indicated in the amendmentare incorporatedduring bid submission.
Thankingyou,
AMENDMENT No. 1
NAME
:
SUPPLY, INSTALLATION & COMMISSIONING OF SDH EQUIPMENTS FOR ESTABLISHING
INTERNATIONAL GATEWAY AND NODAL BANDWIDTH DISTRIBUTION POINTS
REFERENCE : BID NO. : BPC/ ICSD/SDH-1/2K9
A. PREAMBLE
This addendum is being issued pursuant to the queries raised by the Bidders till date and issues
discussed in the Pre-bid Conference held at BPC Conference Hall, Thimphu on April 20, 2009; and other
changes warranted by BPC. The replies to the queries raised by the Bidders are enclosed as Annexure to
this Addendum. The respective clauses in the original Tender document stand amended to the extent
indicated in this Addendum. In case of any discrepancy between the main text of this Addendum and
Annexure to this Addendum (Replies to Bidders' Queries), the provisions of this Main Text govern.
The Bill of Quantity has been revised to incorporate extra details and has been enclosed .
B. CHANGES IN THE TENDER DOCUMENT
I.
NOTICE INVITING BID & SECTION I – INSTRUCTIONS TO BIDDERS:
1.
Deadline for submission of Bids: The deadline for submission of Bids stands extended till 1500
Hrs on May 14, 2009. The bids will be opened on the same day t 1530 Hrs.
II.
SECTION II – CONDITIONS OF CONTRACT:
1.
Add the following sub-clause 14.4 to Clause 14 – Payment
“14.4 The payment for the Goods and Services to be performed under the Contract shall be as
per the following terms:
(a) 70% of the payment related to supply of Equipment (i.e Price Schedule 1 of 2) on
receipt of equipment at site;
(b) 30% of the payment related to the supply of Equipment (i.e Price Schedule 1 of 2)
along with 100% of the payment related to Installation, Testing and Commissioning
(Price Schedule 2 of 2) on completion of all works and successful commissioning,
after adjusting any amounts due including but not limited to Liquidated Damages,
Performance Security etc. “
There is no change to the other provisions for any deductions as indicated in the Conditions of
Contract from the payments due for any taxes and other purposes and the same stand
unaltered.
Page 1 of 19
III.
SECTION III - TECHNICAL SPECIFICATIONS:
1.
SDH network Diagram (Figure 1.1)
The SDH Network diagram (Figure 1.1) has been revised to bring more clarity on the
connection details and BPC’s own requirements. Actual site conditions will determine the final
connectivity which is not expected to deviate too much from the amended SDH network
diagram. The amended network diagram is given below:
Figure 1.1 – SDH NETWORK DIAGRAM (Amended)
The revised SDH Network diagram shows the intended connectivity among various en-route
substations between Phuentsholing and Thimphu and a separate direct connection between
Phuentsholing and Thimphu. It may be noted that the transmission line route with OPGW (24fibre) connectivity is same and the intent is to route 2 fibres via all intermediate substations,
while 2 fibres are intended to be used for direct connection between Thimphu and
Phuentsholing. Bidders are advised to note that for the direct interconnection, amplification if
Page 2 of 19
any, due to long distance between these two terminal stations, shall be achieved by utilizing the
equipment being supplied at one of the intermediary stations. Such arrangement will be part of
the scope of this work and should not result in any additional cost implications to BPC.
2.
Distance between various stations (Table 1.1)of Section III- Technical Specifications
The table stands amended as indicated below. It may be noted that the equipment being
provided shall be suitable for extending the existing as well as proposed links (future
provisions).
Sl.No.
Link
Distance (KM)
OPGW Specification
1.
Bhutan India Border to Siliguri
112
G. 652, DWSM
2.
Malbase to Bhutan India Border
28
G. 652, DWSM
3.
Malbase to Phuentsholing
12
G. 652, DWSM
4.
Phuentsholing to Gedu
17
G. 652, DWSM
5.
Gedu to Chhukha
21
G. 652, DWSM
6.
Chhukha to Watcha
23
G. 652, DWSM
7.
Watcha to Chumdo
16
G. 652, DWSM
8.
Chumdo to Paro
24
G. 652, DWSM
9.
Chumdo to Semtokha
20
G. 652, DWSM
10.
Semtokha to Rurichhu
47
G. 652, DWSM
11.
Rurichhu to Tsirang (Darjey)
49
G. 652, DWSM
12.
Semtokha to Thimphu BPC HQ
11
G. 652, DWSM
13.
Phuntsholing to Thimphu
105
G. 652, DWSM
Link distances for future provision stations
1.
Chumdo to Haa
34
G. 652, DWSM
2.
Phuentsholing to Gomtu
27
G. 652, DWSM
Page 3 of 19
3.
Tsirang (Darjey) to Dagana
20
G. 652, DWSM
4.
Tsirang (Darjey) to Gelephu
40
G. 652, DWSM
5.
Semtokha to Jemina
20
G. 652, DWSM
6.
Malbase to Tala
24
G. 652, DWSM
Table 1.1 Details of Fiber Connectivity (Amended)
3.
Fractional E1 requirement at each substation
In addition to the requirement for each substation, the requirement in terms of fractional E1 at
each substation is 16 nos. of V.24 and 16 nos. of V.35
Further, considering that the final objective of this specification is to be able to provide
fractional E1’s which would be achieved even through the use of additional Mux, provision of
fractional E1 through additional Mux is also considered acceptable. However, in such a case, the
additional Mux should be controllable and configurable through the same Network
Management System. Further, the additional Mux will not be reflected as a separate item in the
BoQ and the cost of the additional Mux will be deemed to have been included in the cost of the
primary Mux being provided. All relevant clauses of the specifications like Clause 1.0 –d, 2.0-b,
2.0 c, 4.2 etc. stand amended to reflect this.
4.
The Table under Clause 4.3 under description “Tributary, electrical interface” the specification
“Per ITU-T G703- 75 ohm” stands amended as “Per ITU-T G703- 120 ohm” ..
5.
Specification for Server, Workstation, Craft terminal, Laser Printer and Rack/cabinet required
for STM equipment
i.
In addition to the details provided for the server, workstation, craft terminal, laser
printer and rack/cabinet the additional minimum requirements are as follows:
a. Server Specification : The minimum requirement is as tabulated below
1) Dual Socket, Dual-Core 1U Rack Server
2) Processor-2 X Quad-Core Intel® Xeon® Processor E5300 Series. X5355,
65nm, 8M L2, NA L3, 2.66 GHz, 1333 MHz FSB, XD, Intel(R) 64, QC, DBS,
VT, FC-LGA6.
3) Memory-8GB 533MHz , Single Ranked DIMMs MEMORY
4) Operating System - Windows based, Integrated SAS/SATA RAID 5,
PERC 5/i Integrated
Page 4 of 19
5) Hard Disk-160GB, SATA, 3.5-inch, 7.2K RPM Hard Drive (FIRST HDD),
160GB, SATA, 3.5-inch, 7.2K RPM Hard Drive (SECOND HDD), 160GB,
SAS, 3.5-inch, 7.2K RPM Hard Drive (THIRD HDD), 160GB, SASI, 3.5inch, 7.2K RPM Hard Drive (FOURTH HDD) Rack Chassis with Static
Rapid Rails
6) NIC-2x Intel® PRO 1000PT Dual Port Server Adapter, Gb NIC, Cu, PCIe
x4
7)Preloaded latest Antivirus
8) Chipset- Intel 5000 X,
9) 17” LCD Rack Console Monitor with rack mini keyboard
b. Work station Specification : The minimum number of workstation has been amended
from one to two. The minimum requirement is as tabulated below;
Branded Desktop Computer with following specification::
1) Intel® Core™ 2 Duo processor E8400 (3.00GHz 1333/3000MHz 4MB L2)
2) Mechanical Package Tower 4X5 Universal 280W AMT
3) USB Ports 4 in rear and 2 in front
4) PC2 6400 800MHz Memory
5) 4GB PC2-5300 SD/DDR RAM (2 DIMMs) , Integrated Video GMA3100 ,
120GB Hard Disk Drive, 7200RPM Serial ATA
6) CD-RW, DVD Combo Drive SATA
7) 56KBPS Soft Modem US -WT FH
8) Integrated Intel Pro 1000T Gigabit
9) IEEE 1394 Adapter
10) Multimedia Keyboard
11) Optical Scroll Mouse
12) 19" LCD Monitor (same brand)
13) Preloaded Genuine Windows XP Professional (with original licensed CD)
Page 5 of 19
14) Preloaded Microsoft Office 2007
15) Preloaded Norton Antivirus 2007
16) All Hardware Drivers in CD/DVD
c. Craft Terminal Specification : The minimum requirement is as tabulated below
Branded Laptop with following specification:
1) 32MB Vedio RAM Non Shareable
2) RAM 4 GB DDR2 upgradable to 8 GB
3) HardDIsc 250GB 7400Mhz
4) 14.1" VGA LCD Screen
5) CD/DVD RW Combo
6) 4+USB Slots
7) Gigabit LAN Card
8) 56 KBPS V 9.2 internal modem
9) Bluetooth 2.0 with EDR support
10) Internal Speaker
11) carry bag
12) keyboard Stickers
13) power supply Adaptor
14) Preloaded Genuine Windows XP Professional SP3 (with original licensed
CD)
15) Preloaded Microsoft Office 2007
16) Preloaded Norton Antivirus 2007
d. Laser printer Specification : The minimum requirement is as tabulated below
i. reputed/branded make
ii. with accessories, driver and printer cable
iii. Printer Speed-35 ppm.
iv. Duplex Printing,
v. Network printing,
vi. duty cycle-65000 pages per month.
vii. resolution-1200x1200dpi.
Page 6 of 19
viii. 550MHz Processor,
ix. 128MB RAM.
x. Paper handling Input tray-Upto 500 Sheets and Output tray-250sheets.
e. Rack/cabinet Specification : The minimum requirement is as tabulated below ;
Specification for equipment cabinets
The equipment supplied should be mounted on suitable racks in closed enclosure cabinets.
The racks and cabinets shall meet the following minimum requirements:
1.0 Equipment Rack
Equipment Racks provided for installation in environmentally controlled facilities, shall
meet the following minimum requirements:
(a) Equipment Sub Racks shall be steel/aluminum fabricated and finished on all surfaces. All
metal and welds shall be thoroughly cleaned and sanded to obtain a smooth finish. All
surfaces shall be treated for rust and primed to form a bond between metal and the finish
coats of paint.
(b) Equipment covers shall be provided for exposed components mounted in equipment
sub Racks.
(c) Dust and moisture protection shall meet or exceed IP20 standards.
2.0 Equipment Cabinet
(a) Equipment cabinets shall be steel/ steel & Aluminum extrusion fabricated and finished
on all surfaces. All metal and welds shall be thoroughly cleaned and sanded to obtain a
smooth finish. All surfaces shall be treated for rust and primed to form a bond between
metal and the finish coats of paint.
(b) Equipment cabinets (enclosures) shall be designed free-standing but shall be mounted
to the floor. Cabinets (enclosures) shall have secure fitting, lockable, full-length front doors
for access to hardware and wiring. Equipment covers for exposed components mounted
inside cabinets are not required unless specifically recommended.
(c) All doors and removable panels shall be fitted with long life rubber beading. All panels
shall be fabricated from minimum 2.0mm thickness steel sheet. However, for racks with
load bearing Aluminum extrusion frame, door panels and side panels may be fabricated
from minimum 1.6mm thickness steel sheet and the top & bottom panels shall be fabricated
from minimum 2.0mm thickness steel sheet.
Page 7 of 19
(d) Equipment cabinets (enclosures) shall be dust and moisture-proof as per IP41
specification, or better.
IV.
SECTION IV- PRICE SCHEDULE
The price schedule has been revised and the revised price schedule are enclosed. These replace
the earlier price schedules and forms part of the bidding document.
C.
CONTENTS OF THIS ADDENDUM
Except for the above, all other terms and conditions of the original Tender documents govern.
This Addendum consists of the following:
(i)
Main Text of the Addendum including revised price schedule
(ii)
Annexure - Reply to Queries received from Bidders
This Addendum along with the above enclosures forms part of the Tender Document.
Page 8 of 19
Annexure - REPLY TO QUERIES RECEIVED FROM BIDDERS FOR SUPPLY, INSTALLATION & COMMISSIONING OF SDH EQUIPMENT FOR
ESTABLISHING INTERNATIONAL GATEWAY AND NODAL BANDWIDTH DISTRIBUTION POINTS. Ref. : Bid No. : BPC/ICSD/SDH-1/2K9.
Sl.
No.
Bidder’s Enquiry
Name of the Bidder:
ECI Telecom
1.
2.
3.
4.
BPC’s Responses
Requirement of equipment at Siliguri Site:
Since this particular span/ link is over 140Kms, it
would be essentially requiring amplifiers. To
ensure smooth interworking and handover, it is
highly recommended to plan for equipment at
Siliguri site, as the amplifiers of different vendors
may or may not inter-operate.
Equipment at Semtokha site: The site has been
excluded from the list of distances. Request you
to confirm the requirement of equipment at
Semtokha site and the pertaining distances.
Interoperability is an important and key requirement for
the equipment to be supplied. The repeater is estimated to
be installed on the Indian side at about 70 kms from
Siliguri ( mid way).
Generalizing the requirement of STM-4 LH
(L4.2) interfaces: It is suggested that all the
aggregate STM4 interfaces being asked in the
tender be of same type i.e. L4.2 to ensure
uniformity at all sites for easier maintenance. The
shorter links, may be supplied with attenuators, if
required
Generalizing the requirement would mean usage of
attenuators . We have specified the distance between
stations. We will use both short haul and long haul
interfaces as required by the distances between
substations.
A STM-4 upgradable to STM 16 is to be installed at
Semtokha too.
Refer revised Table 1.1 & Fig. 1.1of the amendment
document for revised distances and network diagram.
Fractional E1 requirement: It is requested to The requirement of fractional E1 in all the stations are as
share the number and type of 64K interfaces follows:
required in the tender. Ex: 24 no. V.24 and 24
No.V.35 interfaces.
a) V.24 – 16 Numbers
b) V.35 – 16 Numbers
Page 9 of 19
Remarks
5.
Laser Printer: It is requested to share the kind of Please refer Appendix F of this amendment document
laser printer required. For Ex: 300dpi/ 600dpi
Name of the Bidder: Fiberhome Telecommunication Technologies Co. Ltd.
1.
2.
For Chumdo Substation, Watcha Substation,
Chhukha Substation, we understand that there are
4 types of connection, please find attached
"substation connection.doc", please clarify which
type of connection.
Please clarify the distance of the following
station:
Type 3 – Type 3 connectivity species watcha substation as
an intermediary station between Chumdo and Chukha.
Refer revised Table 1.1 & Fig. 1.1of the amendment
document for revised distances and network diagram.
Chumdo Substation to Chhukha Substation
Thimphu BPC HQ to Semtokha Substation
Semtokha Substation to Rurichhu
Chumdo Substation to Semtokha Substation
Please clarify the transmission distance of STM-1 Refer revised Table 1.1 & Fig. 1.1of the amendment
required in Thimphu BPC HQ and Phuentsholing. document for revised distances and network diagram.
3.
Name of the Bidder: Tejas network, India
1.
2.
Request for postponing the pre-bid meeting and
the bid submission date.
Pre bid meeting cannot be postponed however the bid
submission date will be on May 14, 2009( 1500 hours).
The bids will be opened on the same day at 1530 hours.
It will be online.
Please confirm whether required UPS (UPS , 1
phase (5 kVA output, 4 hours backup) is
"ONLINE/OFFLINE" .
Page 10 of 19
3.
4.
Our understanding is that there is no requirement
for Fractional E1’s. In the BOQ also we did not
see any requirement for fractional E1’s. We
request you to remove this from the mandatory
requirement
Our understanding is that the STM-4 mux should
support E1/DS-1,E3, FE, Fx,STM-1, GE
interfaces. Please confirm.
Fractional E1’s is a requirement as per Power utility
requirement. The request to remove fractional E1’s cannot
be entertained. However, we are open to being provided
additional Multiplexer to cater to the fractional E1
In addition to your understanding, we have requested for
Native IP and fractional E1.
Please confirm if the up gradability to STM-16 is
mandatory?
The upgradability is mandatory.
5.
6.
Please confirm if 1+1 redundancy is mandatory
for XCC and PSU modules?
1+1 redundant system is mandatory. This is to achieve a
100% online system. The 1+1 redundancy is only for
critical cards and not all the cards in the system.
STM-4 up-gradable to STM 16 connection is required.
7.
Our understanding is that the interconnection
between the nodes (For ex Semtokha – Chumdo)
is STM-4 connection. Please confirm.
Our understanding is that the E1 termination is
120 Ohm. Please confirm.
8.
9.
Kindly refer to Clause 4.3 of the technical specifications.
The table describing the optical and electrical
characteristics with the description “ Tributary, Electrical
Interface – Per ITU-T G703, 75 ohm” stands amended.
All E1 termination will be 120 ohm.
No more spec for GPS? If we provide OSA 5230 The specification looks acceptable to us. However, the
GPS synchronisation receiver – Rubidium in a specifications for the GPS and the Rubidium clock
19" sub-rack, 2U high, rear facing connectors , - 1 provided must minimize data losses in the network and
x E1/MHz aux input,- Rubidium RMO, ±5eallow for reliable operation of the network.
11/month ,- 8 x E1/2.048 MHz/10 MHz/1 PPS
outputs , - 18-60 VDC power supply, - RS-232
local management , - Factory Acceptance Tests
(FAT), - User Manual on CD-ROM , Drawing
No 945.523.040 will it be OK?
Page 11 of 19
Your requirement DC Power Supply single phase,
output -48 V (15Amp, 24 hours back-up) – 1No
10.
The DC power supply system includes the battery and the
For the DC power plant you have mentioned
specification should meet the DC power supply
24Hr back up. Shall I understand that your total
load is 15 A, to run 15A load you need a DC back requirement for the supplied system at the NOC.
up of 24Hrs . Shall I design Power plant on that
basis ? or you need a power plant of 48V/15A
(n+1). Will you provide battery ?
Name of the Bidder: Telecommunications Consultants India Limited
1.
2.
3.
Kindly refer Section I, Clause 11 – Bid Prices and
Section II, Clause 26, Taxes and Duties. Kindly
intimate the applicable taxes and duties in Bhutan
that have to be taken into account while preparing
the bid.
A foreign Contractors Tax ( FCT) of 3% and for
Domestic Contractors a 2% tax is mandatory. Over and
above that a Bhutan Sales Tax ( BST) is applicable for
goods originating in India and for goods originating from
other countries, both Customs Duty (CD) and the Bhutan
Sales tax becomes applicable. Either tax exemptions for
BST and CD will be provided or else BST and CD will be
refunded after proper documentations are submitted.
Kindly refer Section I, Clause 12 – Bid currencies Goods from outside India will have to be supported by
; Most of the equipments we intend to quote are proper invoice and bill of lading. USD payment will only
from outside India. So we would like to quote be made to third country banks.
these items in US dollars and get the payment of
these items from M/s Bhutan Power Corporation
in US dollars. Kindly clarify whether this will be
acceptable to M/s Bhutan Power Corporation.
Kindly refer Section II, Clause 14 – Payment : No letter of credit will be opened by BPC.
There is no mention about opening letter of credit
for payments to be made to the supplier. Kindly
confirm that no letter of credit will be opened by
M/s Bhutan Power Corporation for effecting
payments under this tender.
Page 12 of 19
4.
5.
6.
7.
8.
9.
Kindly refer Section III, Clause 4.7 : Please Kindly refer to Clause 4.3 of the technical specifications.
specify the following :
The table describing the optical and electrical
STM -1 : Electrical or Optical is required for all characteristics with the description “ Tributary, Electrical
stations.
Interface – Per ITU-T G703, 75 ohm” stands amended.
All E1 termination will be 120 ohm.
E1 : 75 ohm or 120 Ohm.
Kindly refer Section II, Clause 14 – Payment : Refer amendment document
Kindly clarify how the payments shall be effected
i.e the percentage of payments to be released and
at what stage.
Optical fiber lengths to and from Semtokha are Refer revised Table 1.1 & Fig. 1.1of the amendment
not specified in the tender
document for revised distances and network diagram.
With reference to SDH network diagram (figure
1.1 of tender) and optical fiber length table (table
1.1) need more clarification on how Chumdo is
connected to Thimphu.
SDH network diagram shows Malbase is
connected directly to Siliguri (India) whereas
optical fiber length table shows Malbase is
connected to Bhutan India Border need more
clarification here.
Refer revised Table 1.1 & Fig. 1.1of the amendment
document for revised distances and network diagram.
. Thimphu is connected to Chumdo via Semtokha.
The distance between Malbase and Siliguri is about 140
Kms and the distance from Malbase to the Bhutan India
border is about 28 Kms, so 112 Kms of the distance
between Siliguri and Malbase lies on the India side.
Fractional E1’s with the following interfaces are required
per station :
Kindly refer section 3, Technical specification V 35 – 16 Nos.
clause no. 1.0 (d). Requirement of fractional E1 ( V 24 – 16 Nos.
Nx64) has been indicated. However this
requirement is not confirmed in Clause 4.7.
kindly confirm that fractional E1s are required by
M/s BPC.
Page 13 of 19
Name of the Bidder: InfoCare india
1.
2.
3.
4.
5.
What CORE you are using for fiber optic?
What bandwidth you will be using?
BPC optical fiber network is generally a 24 core fiber
network
The requirement is STM 4, upgradable to STM 16
How much MBPS line you will be using?
The requirement is STM 4, upgradable to STM 16
Where the place Mux installation?
The Multiplexers will be installed in BPC’s existing
Power Substations and BPC headquarter building.
This is will be in line with the work station and server
connectivity
5 licenses are required for the NMS
How many points for LAN you will be using?
6.
How many license you want for operating
system?
What is the data transfer rate and data transfer
speed?
The requirement is STM 4, upgradable to STM 16
7.
This will be as per site requirement.
8.
What kind of patch cord you want to use for fiber
optic?
What is the specification for exciting fiber optic?
This has been specified in the Tender Document
What are the numbers of SDH you want to install
along with this place?
This has been specified in the Tender Document
What are the applications you want to use?
The applications vary from International IP Bandwidth, IP
lease circuit, SCADA applications etc.
The NMS system is not expected to be connected to the
Domain Server.
Various terminal/interfaces are required and have been
specified in the tender document and the amendment.
9.
10.
11.
12.
Do you have any Doman server and do you want
to connect with this Doman?
13.
What type of terminal you want to use?
Page 14 of 19
14.
15.
What type of switch you want to use?
How many type of switch you want to use?
16.
What type of security you want (is it hardware
base/ software base)?
17.
Who will provide the Local Area Network
diagram?
As per site requirement with some spares for future up
gradations.
As per site requirement with some spares for future up
gradations.
Licensed copies of both Antivirus and Spy wares are to be
provided both for the server and the work stations
CAT 6
This will be discussed and informed to the successful
bidder
Other issues that were raised and discussed during the Prebid meeting held on April 20, 2009
18.
1
2
3
4
5
6
7
Any network policy ?
Payment after supply of equipment and not after
the commission of the equipment. ( Referred
clause : 14 Section II- Conditions of contract )
Specifications for Server, work station and Craft
terminal ( referred clause : Clause 5.4 to Clause
5.7.3 of Section 3- Technical Specifications )
Requirement of work stations ( Referred Clause :
5.4, III b –Workstations- “ At least one work
station shall be provided”
No. of client users for the NMS
Is there a need to have DDF for 63 E1 in all the
stations.
Specification of the Rack/cabinet required for the
STM equipment.
Is Bank Guarantee from Bhunta Development
Finance Corporation ( BDFC) acceptable?
Refer amendment document
Refer amendment document
The requirement for workstations stands amended as 2
nos.
The minimum number of client users for the NMS is 5
nos.
The DDF requirement will be as per the no of E1’s
required in each substation as specified in Clause 4.7 of
Section 3- Technical Specifications.
Refer Appendix – G for the specification.
Bank Guarantee from BDFC is acceptable.
Page 15 of 19
REVISED PRICE SCHEDULES
Revised Price Schedule for supply of equipment ( 1 of 2)
(Section IV B)
Sl. No.
A
1
i.
ii.
iii.
iv.
v.
vi.
vii.
viii.
ix.
x.
xi.
2
i.
Item Description
Telecom Equipment
SDH Add/Drop MUX (STM-4)
including all cards and
accessories needed for the
specified SDH/PDH
tributary/synchronous interfaces
for the folowing stations:
Malbase
Phuentsholing
Gedu
Chhukha
Watcha
Chumdo
Paro
Semtokha
Rurichhu
Dajey
Thimphu BPC HQ
DDF for E1
DDF for 10 E1
Unit
Pro. Qty.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
1
1
1
1
1
1
1
1
1
1
1
Nos.
3
Currency
Page 16 of 19
Unit Price
FAS
ExIncluding
works
BST/CD
Total
FAS
excl.
BST/C
D
Provision for
BST/CD
Rate
BST
Rate
CD
Value
Total
FAS
Incl.
BST/C
D
ii.
iii.
iv.
v.
3
4
5
B
1
2
3
4
5
6
7
DDF for 20 E1
DDF for 30 E1
DDF for 40 E1
DDF for 63 E1
Cabinet to house the SDH
equipment
GPS & Rubidium clock
Spare cards for the complete
setup for one location, including
CPU, tributary, synchronous
interfaces etc. (Note : break out
price for individual cards should
be furnished)
Requirements at NOC
NMS soft ware complete with
five client user capability
Server for NMS
work stations
Craft Terminal
Laser Printer
DC Power Supply single phase,
output -48 V (6 hours back-up)
UPS , 1 phase (5 kVA output, 4
hours backup)
Total
Nos.
Nos.
Nos.
Nos.
3
3
1
1
Nos.
11
Nos.
2
set
1
Nos.
1
Nos.
Nos.
Nos.
Nos.
1
2
2
1
Nos.
1
Nos.
2
Page 17 of 19
Revised price Schedule for installation, testing and Commissioning ( 2 of 2)
( Section IV B)
Sl. No.
Item Description
A
Telecom Equipment
Unit
Pro.
Qty.
1
SDH Add/Drop MUX (STM-4) including all
cards and accessories needed for the specified
SDH/PDH tributary/synchronous interfaces.
i.
Malbase
Nos.
1
ii.
Phuentsholing
Nos.
1
iii.
iv.
v.
vi.
vii.
viii.
ix.
x.
Gedu
Chhukha
Watcha
Chumdo
Paro
Semtokha
Rurichhu
Dajey
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
1
1
1
1
1
1
1
1
xi.
Thimphu BPC HQ
Nos.
1
2
DDF for E1
i.
ii.
iii.
iv.
v.
DDF for
DDF for
DDF for
DDF for
DDF for
Nos.
Nos.
Nos.
Nos.
Nos.
3
3
3
1
1
10 E1
20 E1
30 E1
40 E1
63 E1
Page 18 of 19
Currency
Unit Price
Amount
3
Cabinet to house the SDH equipment
Nos.
11
4
GPS & Rubidium clock
Nos.
1
B
Requirements at NOC
Nos.
1
2
3
NMS soft ware complete with five client user
capability
Server for NMS
work stations
Nos.
Nos.
1
2
4
Craft Terminal
Nos.
2
5
Laser Printer
Nos.
1
6
DC Power Supply single phase, output -48 V ( 6
hours back-up)
Nos.
1
7
UPS , 1 phase ( 4 hours backup)
Nos.
2
1
Total
Total in words……..
Page 19 of 19