Download CHAPTER 1 - - InverterDelta
Transcript
Chapter 6 - Parameter Description [FU2] FU2-40~46 [Motor parameters] is automatically determined by FU2-40 [Motor selection]. Most suitable motor capacity corresponding inverter capacity is set as factory setting, but the following parameters can be adjusted if necessary. ▣ Use a motor capacity that is equal to or one horsepower level lower than the inverter capacity. ▣ Two types of motor parameters can be set for one inverter, but use only one type for sensorless control. ▣ Use a LG 220V/440V(0.4kW~30kW) class motor. If other makers’ motor or a LG 220V/380V dual rating motor is used, utilize the auto tuning feature in FU2-61 [Auto tuning] before starting. ▣ Set appropriate values for the electronic thermal function, the overload limit function and the stall prevention. The set values should exceed 100% of the rated motor current. ▣ When DRV–04 [Frequency Mode] is set to “V1”, “V1S”, “I”, or “V1+I”, wiring should be conducted to eliminate potential noise influence with the frequency reference. ▣ Pole number of the motor should be 2 pole, 4 pole, or 6 pole. ▣ The distance between the inverter and the motor should not exceed 100m (328 ft). FU2-40~46 [Motor related parameters for Slip Compensation] Code FU2-40 FU2-42 FU2-43 LCD Display Description Motor select Select motor capacity Rated-Slip Motor rated slip (Hz) Rated-Curr Motor rated current (rms) FU2-44 Noload-Curr Motor no load current (rms) FU2-45 Efficiency Motor efficiency (%) FU2-46 Inertia rate Motor inertia rate Note: Incorrectly set FU2-44 [Motor No-load Current] value may weaken the Sensorless control. ◈ Sensorless (Sensorless vector speed control) operation: Use it when 1) high starting torque is needed at low speed 2) load fluctuation is high 3) rapid response is needed. To use this function, set FU2-40~46 [Motor parameters] and FU2-60 [Control mode select] properly. If not using LG 220V/440V Class motor: Set “Yes” in FU2-61 [Auto tuning] first before using this control. [Cautions on Sensorless Vector Control] Related parameters: FU2-40~46, FU2-60, FU262~66 Code LCD display Parameter FU2-62 RS Stator resistance FU2-63 Leakage inductance Lsigma FU2-65 SL P-gain Sensorless P gain FU2-66 SL I-gain Sensorless I gain [Guide for Optimal Use of Sensorless Vector Control] For optimal use of the sensorless control, the following conditions should be met. If one of the following conditions is not satisfied, the inverter may malfunction due to insufficient torque, irregular rotation, or excessive motor noise. In this case, it is recommended to use V/F control. 6-31 ▣ Forced-cooling should be used for the motor when the average operating speed is under 20Hz and more than 100% load is used constantly. ▣ Motor may rotate 0.5% faster than the maximum speed if the motor temperature does not reach normal operating temperature. ▣ Utilize the auto-tuning feature when the motor reaches normal temperature (average temperature where the motor normally operates). ▣ Output torque may be reduced when an output filter option is used between the inverter and the motor. ▣ Overcurrent trip may occur if FU2-62 [Stator