1.5 Transport & Storage conditions
The following specifications apply
Description
Details
Drop with packing conforming to
IEC 60068-2-31
Drop with out packing
Temperature
Relative Humidity
Altitude
Sinusoidal vibration conforming to
IEC 60068-2-6
10 drops from 60cm on 1 corner,
3 edges, 6 surfaces
Nil
-20 0C to + 60 0C
10% to 90%, no condensation
2000 meters maximum
5 to 10 Hz: 3.5 mm amplitude
10 to 150 Hz: 2g 1oct/min. 40
sweeps
Shock conforming to IEC 60068-2- 3 shocks per direction 11ms 15g
29
Best conditions for storage of LCD display modules
1. Room ambient temperature 15 0 to 35 0 C and 65% RH or less.
2. Do not store in surroundings containing organic solvent or corrosive gas.
3. Store HMI in anti-electrostatic container or bag.
1.6 Operating conditions
Description
Details
0 0C to + 50 0C
10% to 90%, no condensation
2000 meters maximum
Degree 2
10 to 58Hz: 0.75mm amplitude
58 to 150Hz: 1g 1oct/min. 1
sweep
Shock conforming to IEC 60068-2- 3 shocks per direction 11ms 10g
29
Temperature
Relative Humidity
Altitude
Pollution
Sinusoidal vibration conforming to
IEC 60068-2-6
In the case of temperatures below 0 OC, the response time of liquid crystal
becomes slower and color of the display will be darker than normal. Do not operate HMI
in ambient temperature less than 0 OC.
7