GPH-3300 Help for Linux ulSmplNum Specifies the event interval according to the count of output update from 1 through 16777215. When DA_TRG_SMPLNUM is specified to ulStopTrigCondition, analog output update will be stopped when the event is occurred. The default setting value is 1. UlStartTrigCondition Specifies start-trigger condition of analog output. One of the following *1 codes must be set exclusively. Code Description DA_TRG_FREERUN No trigger (default setting) DA_TRG_EXTTRG External trigger DA_TRG_ATRG Analog trigger DA_TRG_SIGTIMER Interval timer DA_TRG_AD_START AD start DA_TRG_AD_STOP AD stop DA_TRG_AD_PRETRG AD pre-trigger DA_TRG_AD_POSTTRG AD post-trigger ulStopTrigCondition Specifies stop-trigger condition of analog output. One of the following *1 codes must be set exclusively. Code Description DA_TRG_FREERUN No trigger DA_TRG_EXTTRG External trigger DA_TRG_ATRG Analog trigger DA_TRG_SIGTIMER Interval timer DA_TRG_AD_START AD start DA_TRG_AD_STOP AD stop DA_TRG_AD_PRETRG AD pre-trigger DA_TRG_AD_POSTTRG AD post-trigger DA_TRG_SMPLNUM The specified number of data are output. DA_TRG_FIFO_EMPTY FIFO empty (default setting)*2 The following codes are ORed with the stop-trigger condition. Code Description *3 DA_RETRG Retrigger DA_FIFO_RESET Resets FIFO.*4 Copyright 2002, 2003 Interface Corporation. All rights reserved. 100