H3000 Pilot Handbook___________________________________________________ Fault 110 - No Optimum Wind Data Fault Description No Optimum Wind Angle data is being received via the Fastnet network. Remedial Action 1) Check the Optimum Wind Angle (OPT W/A) data displayed on the instrument system. 2) Check connections to instrument system. Fault 111 - Current Trip: Drive or Clutch Fault Description The current limiting circuit for the drive motor (25A on ACP1, 40A on ACP2) or the clutch (2A) has tripped. Remedial Action 1) Check the installation and wiring for short circuits or loose connections. 2) Check the current to the clutch, if this exceeds the maximum value the fault will occur immediately. 3) Check the current to the drive motor, if this exceeds the maximum value the fault will occur immediately. 102 HB-3001-01