Maintenance & Troubleshooting Condition Description Cond. Type Sev. Cards in cause Description o Action When false CRC-4 values rate of the total number (1000) during 1s, is higher or equal than the Threshold selected Dead EQPT MJ All The system is not able to communicate with the card EGC Link Broken LNKBRK MJ EGC-A, EGC-B No signal at all is received by the EGC card EGC Link Signal Failure LNKSIG MJ EGC-A, EGC-B One signal is not received by the SGC card External Alarm EXT CR, MJ, MN, N/A EXT1…EXT-10 Fast Start FSTSYNC N/A THC External alarms coming from third party equipment connected to the input port alarm on the Management tile. EXT-1..3=CR; EXT-4..6=MJ; EXT7..9=MN; EXT-10=N/A The THC card is in fast-start mode in order to synchronize its system against the input signal selected rapidly. Free Run FRNGSYNC MJ THC OSA 5548C SSU-E60 - User Manual - Revision P - October 2013 The THC card has not been fed with input signal reference since it has been powered-up 8-31 1. Initialize the card in question 2. Pull it out and reinsert it 3. If the above action did not clear this alarm, return the card for repair Check the cable connected to LINK A and/or LINK B connector on Management Tile. Check the cable connected to LINK A and/or LINK B connector on Management Tile. Check the device connected to the alarm input which presents an alarm. No action needed, leave the THC ending their fast start procedure. If this behavior was not excepted, follow this procedure: 1. Check the INC cards