37 3.2.6. PTZ Check the below items for proper P/T/Z operation. Check if the protocol of the connected PTZ camera is correct. Check if the communication setting including baud rate of the connected PTZ camera is in accordance with the assigned value for that P/T/Z protocol. Check if the address of the connected PTZ camera is correct. Check if wiring to P/T/Z controllers is correct. Procedure How to setup PTZ camera with Pelco-D protocol (example) 1) Make sure of serial communication with the PTZ camera through RS-485 port. 2) Select “Pelco-D” in the protocol list, and set address & baud rate. 3) Click “Save” button to confirm this configuration. PROTOCOL Select the proper protocol of the connected PTZ camera. BAUD RATE User can select the baud rate level from 2,400bps up to 57,600bps. ADDRESS Set the P/T/Z driver address of the connected camera. CONTROL When the SET button is clicked, OSD menu of the PTZ camera will be shown on the monitor. User can set the PTZ such as speed, preset, tour, autopan and so on. PRESET The system supports the number of preset from 1 to 255. But it can be restricted by the number that PTZ camera supports.