GENERAL Table 1 - General Data Boiler Size HE15HE18HE24HE30HE36 Gas Supply Connection Rc 1/2 in. BSP Flow and Return Connections Rc 1/2 22mm copper 22mm copper Rc 1/2 Rc 1/2 Rc 1/2 22mm copper 22mm copper 22mm copper maximum Static Water Head m (ft.) 30.5 (100) 30.5 (100) 30.5 (100) 30.5 (100) 30.5 (100) MINIMUM Static Water Head m (ft.) 0.45 (1.5) 0.45 (1.5) 0.45 (1.5) 0.45 (1.5) 0.45 (1.5) Electrical Supply 230V - 50Hz 230V - 50Hz 230V - 50Hz 230V - 50Hz 230V - 50Hz Power Consumption 38W 38W 38W 42W 42W Fuse RatingExternal : 3A internal T3.15A L250V Water Content litre (gal.) 2.0 (0.44) 2.0 (0.44) 2.0 (0.44) 4.7 (1.0) 4.7 (1.0) Packaged Weight kg. (lb.) 55.4 (122.4) 55.4 (122.4) 55.4 (122.4) 69 (152) 69 (152) Maximum Inst Weight kg. (lb.) 52 (114.6) 52 (114.6) 52 (114.6) 68 (150) 68 (150) Boiler Size Height mm (in.) 850 (33.5) 850 (33.5) 850 (33.5) 850 (33.5) 850 (33.5) Width mm (in.) 450 (17.7) 450 (17.7) 450 (17.7) 450 (17.7) 450 (17.7) Depth mm (in.) 530 (20.9) 530 (20.9) 530 (20.9) 530 (20.9) 530 (20.9) Gas Type I2H-G20 I2H-G20 I2H-G20 I2H-G20 I2H-G20 Gas Supply Pressure 20mb 20mb 20mb 20mb 20mb 100 (4) 100 (4) 100 (4) 100 (4) 100 (4) 6 6 6 3 3 Flue duct diameter mm (in.) Flue horizontal duct length (max) m Table 2 - Performance Data Boiler Size HE15HE18HE24HE30HE36HE15-24HE30-36 max maxmaxmaxmax min min Input ‘Q’ Nett CV Gross CV kW (Btu/h) kW (Btu/h) Gas Consumption l/s (cu.ft/h) 15.1 (51,500) 18.7 (63,800) 24.4 (83,300) 30.7 (104,700) 37.5 (128,000) 9.1 (31,000) 10.6 (36,200) 16.8 (57,200) 20.7 (70,800) 27.1 (92,500) 34.0 (116,000) 41.6 (142,000) 10.1 (34,400) 11.8 (40,300) 0.43 (54.7) 0.53 (68.0) Output ‘P’ 70oc Mean Water temp. kW (Btu/h)14.6 (50,000) 18.2 (62,300) 40oc Mean Water temp. kW (Btu/h)15.5 (53,000) 19.2 (65,700) Seasonal efficiency (SEDBUK) * Band A [90.4]% 0.70 (89.7) 0.26 (33.3) 0.30 (38.4) 23.4 (80,000) 30.1 (102,700) 37.0 (126,200) 8.8 (30,000) 10.6 (36,200) 25.1 (85,700) 32.8 (111,800) 39.8 (135,800) 9.6 (32,800) 11.4 (38,900) - - [90.3]% [90.2]% NOx classification * 0.88 (111.9) [90.4]% 1.07 (136.0) [90.7]% Class 5 The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from which it has been calculated have been certified by a notified body. Key to symbols Note. Gas consumption is calculated using a calorific value of 38.7 MJ/m3 (1038 Btu/ft3) gross or 34.9 MJ/m3 (935 Btu/ft3) nett. To obtain the gas consumption at a different calorific value:- GB = United KingdomIE = Ireland (Countries of destination) PMS=Maximum operating pressure of water C13 c33 = A room sealed appliance designed for connection via ducts to a horizontal or vertical terminal which admits fresh air to the burner and discharges the products of combustion to the outside through orifices which, in this case, are concentric. The fan is up stream of the combustion chamber. I2H An appliance designed for use on 2nd Family gas, Group H only. a. For l/s- divide the gross heat input (kW) by the gross C.V. of the gas (MJ/m3) b. For ft3/h - divide the gross heat input (Btu/h) by the gross C.V. of the gas (Btu/ft3) c. For m /h - multiply l/s by 3.6 3 = Caution. To avoid the possibility of injury during the installation, servicing or cleaning of this appliance, care should be taken when handling edges of sheet steel components. 4 201787-9.indd 4 mexico HE - Installation & Servicing 25/03/2013 13:53:15