Download INSTALLATION AND SERVICING

Transcript
GENERAL
Table 1 - General Data
Boiler Size
HE15HE18HE24HE30HE36
Gas Supply Connection
Rc 1/2
in. BSP
Flow and Return Connections
Rc 1/2
22mm copper 22mm copper
Rc 1/2
Rc 1/2
Rc 1/2
22mm copper
22mm copper
22mm copper
maximum Static Water Head
m (ft.)
30.5 (100)
30.5 (100)
30.5 (100)
30.5 (100)
30.5 (100)
MINIMUM Static Water Head
m (ft.)
0.45 (1.5)
0.45 (1.5)
0.45 (1.5)
0.45 (1.5)
0.45 (1.5)
Electrical Supply
230V - 50Hz
230V - 50Hz
230V - 50Hz
230V - 50Hz
230V - 50Hz
Power Consumption
38W
38W
38W
42W
42W
Fuse RatingExternal : 3A internal T3.15A L250V
Water Content
litre (gal.)
2.0 (0.44)
2.0 (0.44)
2.0 (0.44)
4.7 (1.0)
4.7 (1.0)
Packaged Weight
kg. (lb.)
55.4 (122.4)
55.4 (122.4)
55.4 (122.4)
69 (152)
69 (152)
Maximum Inst Weight
kg. (lb.)
52 (114.6)
52 (114.6)
52 (114.6)
68 (150)
68 (150)
Boiler Size
Height
mm (in.)
850 (33.5)
850 (33.5)
850 (33.5)
850 (33.5)
850 (33.5)
Width
mm (in.)
450 (17.7)
450 (17.7)
450 (17.7)
450 (17.7)
450 (17.7)
Depth
mm (in.)
530 (20.9)
530 (20.9)
530 (20.9)
530 (20.9)
530 (20.9)
Gas Type
I2H-G20
I2H-G20
I2H-G20
I2H-G20
I2H-G20
Gas Supply Pressure
20mb
20mb
20mb
20mb
20mb
100 (4)
100 (4)
100 (4)
100 (4)
100 (4)
6
6
6
3
3
Flue duct diameter
mm (in.)
Flue horizontal duct length (max)
m
Table 2 - Performance Data
Boiler Size
HE15HE18HE24HE30HE36HE15-24HE30-36
max maxmaxmaxmax min min
Input ‘Q’ Nett CV
Gross CV
kW (Btu/h)
kW (Btu/h)
Gas Consumption l/s (cu.ft/h)
15.1 (51,500) 18.7 (63,800) 24.4 (83,300) 30.7 (104,700) 37.5 (128,000)
9.1 (31,000)
10.6 (36,200)
16.8 (57,200) 20.7 (70,800) 27.1 (92,500) 34.0 (116,000) 41.6 (142,000) 10.1 (34,400)
11.8 (40,300)
0.43 (54.7)
0.53 (68.0)
Output ‘P’ 70oc Mean Water temp. kW (Btu/h)14.6 (50,000) 18.2 (62,300)
40oc Mean Water temp. kW (Btu/h)15.5 (53,000) 19.2 (65,700)
Seasonal efficiency (SEDBUK) *
Band A
[90.4]%
0.70 (89.7)
0.26 (33.3)
0.30 (38.4)
23.4 (80,000) 30.1 (102,700) 37.0 (126,200)
8.8 (30,000)
10.6 (36,200)
25.1 (85,700) 32.8 (111,800) 39.8 (135,800)
9.6 (32,800)
11.4 (38,900)
-
-
[90.3]%
[90.2]%
NOx classification
*
0.88 (111.9)
[90.4]%
1.07 (136.0)
[90.7]%
Class 5
The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by a notified body.
Key to symbols
Note.
Gas consumption is calculated using a calorific value of
38.7 MJ/m3 (1038 Btu/ft3) gross or 34.9 MJ/m3 (935 Btu/ft3)
nett. To obtain the gas consumption at a different calorific
value:-
GB = United KingdomIE = Ireland (Countries of destination)
PMS=Maximum operating pressure of water
C13 c33
=
A room sealed appliance designed for connection
via ducts to a horizontal or vertical terminal which admits
fresh air to the burner and discharges the products of
combustion to the outside through orifices which, in
this case, are concentric. The fan is up stream of the
combustion chamber.
I2H
An appliance designed for use on 2nd Family gas, Group
H only.
a. For l/s- divide the gross heat input (kW) by the gross
C.V. of the gas (MJ/m3)
b. For ft3/h - divide the gross heat input (Btu/h) by the
gross C.V. of the gas (Btu/ft3)
c. For m /h - multiply l/s by 3.6
3
=
Caution.
To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance, care should be taken when handling edges of sheet steel components.
4
201787-9.indd 4
mexico HE - Installation & Servicing
25/03/2013 13:53:15