Download G620 GPRS Module AT Command User Manual - Premier
Transcript
The following table shows the +CPOL parameters. <Parameter> Description <indexn> Order number of network operator in the SIM preferred operator list <format> Defines the <oper> format: <oper> 0 Long alphanumeric format (up to 16 characters) (default) 1 Short alphanumeric format (up to 8 characters) 2 Numeric Name of the network operator Note1: If <index> is given but <oper> is left out, entry is deleted. If <oper> is given but <index> is left out, <oper> is put in the next free location. If only <format> is given, the format of the <oper> in the read command is changed. Note2: User is prevented from editing index No. 0. This index is reserved for the HPLMN record and can not be modified. When entering a new item with an <index> to a full list, the G620 deletes the last item, stores the new item in the requested entry, and shifts the rest of the list down. When entering a new item without an <index> to a full list, the G620 replaces the last entry with the new item. Note3: MT may also update the User controlled PLMN selector with Access Technology list - EFPLMNwAcT, automatically when new networks are selected. Note4: The Operator controlled PLMN selector with Access Technology EFOPLMNwAcT and HPLMN selector with Access Technology - EFHPLMNwAcT can not be written since the access conditions is Administrative. Note5: The command is implemented according to 3GPP TS 27.007 without acceptance in attention the <GSM_AcT2>, <GSM_Compact_AcT2>, <UTRAN_AcT2>] bits since the G620 device not using this bits to get the best PLMN. Example: AT+CPOL=? +CPOL: (001-032),(000-002) G600 GPRS Module AT Command User Manual Page 120 of 198