Download MCX312 User`s Manual
Transcript
MCX312 – M62 NOVA electronics Inc. RR4 RR5 H D15 D14 D13 D12 X- LM- X- LM+ X- IN5 X- IN4 D15 D14 D13 D12 Y- LM- Y- LM+ Y- IN5 D11 D10 D9 D8 X- IN3 X- IN2 X- IN1 X- IN0 D11 D10 D9 D8 Y- IN3 Y- IN2 Y- IN1 H Y- IN4 Y- IN0 D7 D6 D5 D4 L X - ALM X - INP X - EX - X - EX+ D7 D6 D5 D4 D3 D2 ENG X- ST2 L D3 Y - ALM Y - INP Y - EX - Y - EX+ - Bit Name Input Signal Bit Name Input Signal n-ST0 n-STOP0 n-IN0 nIN0 n-ST1 n-STOP1 n-IN1 nIN1 n-ST2 n-STOP2 n-IN2 nIN2 EMG EMGN n-IN3 nIN3 n-EX+ nEXPP n-IN4 nIN4 n-EX- nEXPM n-IN5 nIN5 n-INP nINPOS n-LM+ nLMTP n-ALM nALARM n-LM- nLMTM D2 D1 D0 X- ST1 X- ST0 D1 D0 Y - ST2 Y - ST1 Y - ST0 4.15 Data-Read Register: RR6 / RR7 According to the data-read command, the data of internal registers will be set into registers RR6 and RR7. The low word 16 bits (D15 ~ D0) is set in RR6 register, and the high word 16 bits (D31 ~ D16) is set in RR7 register for data reading. RR6 RR7 D15 D14 D13 D12 RD15 RD14 RD13 RD12 D15 D14 D13 D12 RD31 RD30 RD29 RD28 H H D11 D10 D9 D8 D7 D6 D5 RD11 RD10 RD9 RD8 RD7 RD6 RD5 D11 D10 D9 D8 D7 D6 D5 RD27 RD26 RD25 RD24 RD23 RD22 RD21 The data is binary formatted; 2’ s complement is for negatives. – 62 – D4 L RD4 D4 RD20 L D3 D2 D1 D0 RD3 RD2 RD1 RD0 D3 D2 D1 D0 RD19 RD18 RD17 RD16