Skantherm Turn: Installation and User Manual 1. Technical Data 2 2. PRE-Installation 3 3. Installation 5 4. Operation 9 5. TestING 10 Keep for future use Oblica 200 Argyle St Fitzroy VIC 3065 03 9416 0400 1. Technical Data Weight and dimensions: Dimensions Firebox weight Flue kit W1150 x H852 x D382mm 213kg Standard 6” Determined under test conditions: Nominal thermal output Efficiency 5kW 78,4% FLUE 852 Standard 6” 1150 oblica | turn Installation and User Manual page 2 2. Pre-INSTALLATION Congratulations on your purchase of the Turn. This appliance should be installed and checked by a qualified professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or concerns please contact Oblica on 03 9416 0400. The installation process is outlined below: – Determine position of firebox and flue carefully observing the clearances described within this section – Install the external flue – Install the internal flue and engage the firebox – Ensure the floor has adequate protection Caution: Using components or parts other than those provided by the manufacturer or modifying the specification of components may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the first instance. Warning: • The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the relevant building code or codes. • Any modification of the appliance that has not been approved in writing by the testing authority will be in breach of the approval granted for compliance with AS/NZS 4013. • Once the flue has been installed and approved by a professional installer, the flue must not be modified in any way. oblica | turn Installation and User Manual page 3 2. Pre-INSTALLATION (CONTINUED) MINIMUM CLEARANCE – INTERNAL 2.1 Clearance from non-combustible surfaces (eg masonry) 2.3 Clearance from combustible surfaces (eg timber joist & concrete) 100mm minimum clearance is required from fully non-combustible surfaces. Clearances may be reduced with the application of heat shielding to walls in accordance to the Australian Building Code. Combustible Non Combustible 280 100 For information on heat shielding please contact our office on 03 9416 0400 or email [email protected]. Co m st ib le 420 bu st ib Co m bu le Co st ib l Co e m bu 0 le bu st ib le m bu st ib 0 le Co 0 14 bu st Com ib bu le st ib m Co 14 m bu 14 st ib le m Co 0 14 14 0 0 0 IMPORTANT: Frames must also be considered. Timber window frames must be treated as combustible surfaces (see 2.3). Aluminium frames can be treated as non-combustible surfaces (see 2.2). oblica | turn Installation and User Manual Combustible Combustible 420 14 400 0 400 14 400 400 400 400 420 Configuration 2 – Corner installation 14 Glass Glass (frameless or aluminium frame) (frameless or aluminium frame) Glass (frameless or aluminium frame) Glass (frameless or aluminium frame) 400 400 Glass (frameless or aluminium frame) Glass (frameless or aluminium frame) Combustible Combustible 500mm minimum clearanceGlass is required from normal (frameless or aluminium 100 frame) non-combustible glass. 350mm minimum clearance is required from toughened glass. Glass (frameless or aluminium frame) Combustible 280 Non Combustible 100 Combustible 280 Non Combustible 100 100 2.2 Clearance from glass 420 Combustible Non Combustible 100 Non Combustible Configuration 1 – Parallel installation 280 100 Non Combustible Non Combustible 100 Non Combustible page 4 3. InstallATION 3.1 Typical flue kit installation Cowl (Chinaman Hat) 8” Outer Case 10” Outer Case RUBBER DEKTITE FLASHING 6” Active Flue 8” Outer Case 10” Outer Case CEILING RING 8” Outer decorative casing 6” Active Flue Crimped end up on dec outer case 8” Outer decorative casing FIREBOX oblica | turn Installation and User Manual page 5 3. InstallATION (CONTINUED) 3.2 Installing the external flue 1.Place the connection piece inside the suspension bracket. This will join the single skin flue below the bracket and the triple skin flue above the bracket which have different diameters. 2.Ensure the triple skin flue is installed as per Australian standards (see diagrams below). Pitched roof installation The top of the flue must be 400mm higher than the highest point of the roof. Alternatively, there must be a minimum distance of 8 meters from any higher section of roof. –> 40 cm –> 40 cm > –8m > 40 – cm –> 40 cm > –8m > 40 – cm –> 40 cm cm –> 120 Flat roof installation (less than 5˚ pitch) –> 120 cm > –8m > – 120 cm The top of the flue must be 1200mm above the roofline. Alternatively, there must be a minimum distance of 8 meters from any higher section of roof. –> 120 cm –> 120 cm oblica | turn Installation and User Manual > –8m > – 120 cm page 6 3. InstallATION (CONTINUED) 3.3 Protecting the floor •Any combustible floor beneath a fireplace must have a floor protector that extends 300mm beyond the diameter of the firebox in all directions. •If installed directly on combustible material, the floor protector must be made of a minimum 6mm thick cement sheet. Non-combustible finishes can be applied to the floor protector (tiles, steel sheet, light concrete, etc). • If the combustible floor is installed on concrete, you can replace the combustible material with noncombustible material laid directly onto the concrete. Floor protector laID on timber floor Insulative board (6mm) + non combustible finish Insulative board (6mm) + non combustible finish Combustible floor (eg. timber) Combustible floor (eg. timber) Combustible floor (eg. timber) Combustible floor (eg. timber) Joist Concrete Joist Concrete Floor protector laId on Joist 1200mm 1200mm 80mm Combustible floor (eg. timber) Combustible floor (eg. timber) Insulative board (6mm) + non combustible finish Insulative board (6mm) + non combustible finish 1180mm 1180mm 80mm Joist Joist oblica | turn Installation and User Manual page 7 Floor protector lAID on CONCRETE Combustible floor (eg. timber) Non combustible finish (eg.tiles) 140mm Combustible floor (eg. timber) Non combustible finish (eg.tiles) Concrete 140mm 1200mm Concrete 80mm 80mm TOP VIEW 1200mm ) h 80mm 80mm 1180mm ) h 3. InstallATION (CONTINUED) C 1180mm Floor protector Combustible floor (eg: Timber) Floor protector Combustible floor (eg: Timber) oblica | turn Installation and User Manual page 8 4. OPERATION 4.1 What you should burn • Untreated, air dried hardwood •Split logs with a humidity content of less than 20% 4.2 Do not burn • Trash • Painted plastic • Coated or preservative treated wood • Waste or black coal •Inflammable liquids • Fire gels • Moist wood with a residual humidity content of more than 20% (this may cause soothing of the chimney). IMPORTANT: • Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee. • The maximum load capacity for the Turn is 10kg of wood. • Burning only seasoned hardwood helps to protect the environment and lower emissions. For details of a wood supplier in your area please call our office on 03 9416 0400 or email [email protected]. Warning: • Do not use flammable liquids or aerosols to start or rekindle the fire. • Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating. • Do not store fuel within prescribed installation clearance distances. • The use of some types of preservative-treated woods as a fuel can be hazardous. oblica | turn Installation and User Manual page 9 5. Testing Test report No 30A-13-0024-TRP-335261-0 TESTING LABORATORY: Vipac Engineers & Scientists Port Melbourne VIC 3207 MANUFACTURER: Skantherm GMBH MODEL: Turn fireplace WORK REQUESTED: Assessment of appliance to AS/NZS 4012:1999 for determination of Power Output and Efficiency and AS/NZS 4013:1999 for Flue Gas Emission using hardwood fuel. Test Dates: 29/10/2013 to 18/11/2013 INVESTIGATING OFFICERS: Christian Schmidt, Rebecca Searcy RESULTS: The appliance particulate emission factor established in testing is 2.9g/kg of dry wood, within the maximum specification of 4.0g/kg of dry wood. CONCLUSION: This appliance does comply with the requirements of AS/NZS 4013:1999 for the configuration tested. oblica | turn Installation and User Manual page 10