Download Installation Guide for Schrödinger Software Release
Transcript
install_guide.book Page 88 Thursday, May 22, 2014 10:28 AM Chapter 7: Preparing for Job Submission 3. Compute nodes must be able to open socket connections to each other and to the manager node. They should also be able to connect to a node or host from which jobs can be submitted. 4. Passwordless SSH must be enabled: a. from the job submission host to the manager node; b. from the compute nodes to the manager node. For parallel Jaguar, the following are required in addition: • The user’s home directory has to be mounted on the compute nodes. • Passwordless SSH has to be enabled between compute nodes. 7.5.2 Secure Channel Communication and Firewalls Job Control uses an SSH tunnel for data transfer between the job submission host and the queue host to ensure secure transfer, by default (the “secure channel”). This applies to communication to and from a cluster. Within a cluster, Job Control uses ports above 1024 for communication between the manager node and the compute nodes, using socket connections. To configure the manager node for secure channel access: 1. Block ports above 1024 in the firewall on the externally facing network. 2. Leave ports above 1024 open on the cluster’s internal network. If you want to leave some ports above 1024 on the externally facing network open for other applications, you should do the following: 1. Choose a port range that you can block, and block these ports. Ensure that there are sufficient ports in the range for all users’ jobs, e.g. a few hundred. 2. For each cluster entry in the hosts file, add a proxyport entry that specifies this port range. If you want to turn off encrypted data transfer you can do so, but you should ensure that you trust the network on which the clusters to which you submit jobs are connected. For clusters on your trusted network, you can create securezone entries in the hosts file—see Section 7.1.11 on page 58 for information. If all your clusters are on a trusted network, you can set the environment variable SCHRODINGER_SECURE_TRANSFERS to 0, to disable all secure channel communication. You can also set this environment variable to 1 to enforce secure channel communication regardless of the securezone settings. If you want to enforce this policy globally, you can use a site configuration file—see Appendix D. Note: 88 The secure channel mechanism is not available for job submission from Windows. Schrödinger Software Release 2014-2