Huahuan
Beijing Huahuan Electronics Co., Ltd
Fig. 4-3
PWR-IN Card
4.2.2 Power Card (PWR)
The power card converts -48VDC power supply to 5VDC internal voltage. Each card
can supply 100 watts which is enough for a full LMX system power consumption. That is,
the LMX can be powered with a single power card. But for higher operation reliability, it is
recommended to use two power cards in 1+1 redundancy. Each power card has its own
power switch.
H9MO-LMX.PWR
5V
LED1
Power Switch
PWR
Fig. 4-4 Power Card
4.2.3 Auxiliary I/O Card (AUX-IO)
The AUX-IO card holds external clock ports, shelf alarm output pot, and orderwire
telephone jack. The upper 3 BNC connectors are for external clocks, 2 clock inputs denoted
INA and INB, and an output connector denoted OUT. In the middle is the shelf alarm
output connector. The upper post is the prompt alarm pin, and the lower post is the differed
alarm pin. When alarms present, the respective alarm output pin is earthed, otherwise it is
floated. The RJ11 port at the bottom is the phone jack for orderwire telephone. This
telephone is also used as a hand held input device for LCD menu selection.
- 14 -