Download User manual
Transcript
KRALmeter-3 NAMEPLATE DESCRIPTION (example) Trademark Test output, LED RL Symbols: - three-phase system - accuracy class - standards compliance - reverse running stop Standard application RL TECHNICAL DATA Type designation KRALmeter Drehstromzähler IS-C 35.65LE MXX 3 x 230/400V, 0,25-5(65)A, 50Hz RL/RA = 1,0Wh/Imp.: 3K6 M2/E2 Schaltung 4600 (DIN 43856); V1.4 B EN 50470 DE-08-MI003-PTB003 XXXX Výrobní číslo - rok výroby EU conformity mark, type approval MID, module B The measured value (5.2 or 6.1 places) kWh Voltage, current, frequency LED pulses constant and pulse output Number of connection type Type test approval number Applied construction standards Type of connection to the electricity network DE 07-MI003 PTB003 EN 50470-1:2006 and EN 50470-3:2006 No. 4600 or 4702 according to DIN EN 43856 standard Reference voltage and frequency Un = 3×230/400 (1 ± 10 %)V, fn = 50 (1 ± 2 %)Hz Ist = 0,02A, Imin = 0,25A, Itr = 0,5A, Iref = 5A, Imax = (65)80A class B (± 1% ), alternatively class A ( ± 2%) Current limits Accuracy class (see meter imprint) Operation display / test output - optical flashing red LED Standstill / reverse running stop Display / register / memory optical LED, red permanent lighting LCD or electromechanical register 6 digits - full places for kWh and 1 decimal place (0.1 x kWh) Number of places (see meter) Pulse constant, optical (see meter imprint) Pulse constant, electrical (see meter imprint) Number of pulses / clock period accuracy Pulse output - passive electric Pulse constant - electrical Tariff control voltage (only IS-C 35.XX LD) Extended operating voltage range; conditions Measured current (see meter) Extended operating frequency range Internal power consumption in voltage circuit Apparent power consumption in voltage circuit Apparent power consumption in current circuit Actual starting current (three-/singlephase) Standard 1000 imp/kWh (1 Wh/imp) Standard 1000 imp/kWh (1 Wh/imp) At least one pulse with an integration time of 5 seconds Potential-free according to DIN EN 62053-31 standard class A and B Umax = 30VDC, Imax = 30mA , tmin = 30ms, reverse polarity protection 230 (1 ± 10%)V, 50Hz 180V up to 265V, three-phase voltage, clockwise 0,25…5(80)A, 0,25…5(65)A, 0,5…10(60)A, 0,5…10(80)A 45Hz up to 60Hz at Un and fn ≤ 0.9W per phase at Un and fn ≤ 8.0VA per phase, cosφ 0.11k at Iref ≤ 0.1VA, at Imax ≤ 2.5VA I ≈ 18 mA per phase at Un, fn and cosφ1 Higher harmonic frequencies accepted up to 4 kHz 3K6; -25°C up to +55°C, Working temperature range indoor installation annually average ≤ 75%, Maximum air humidity short-term 95%, non-condensing Environmental conditions mechanical M2, electro-magnetic E2 Electrical protection class II, Electrical protection protection insulation meter cover IP51 when closed terminal Electrical protection degree covers Design size 2, depth 55 mm, 5 units on Dimensions and meter size DIN rail (5-TE) 89.6 mm width, 92.5 mm height, 60.2 External meter dimensions mm depth on DIN rail according to EN DIN 50022 Fixing and installation standard, position-independent Internal power supply three-phase capacitor power supply Polycarbonate blended with 6 % of the Housing material fibers >PC-GF6< Size of connection wires for terminals 1 2.5 mm², max.: flexible wire 16 mm², up to 11 solid wire 25 mm² © KRALgroup Meinlinova 309 CZ-190 16 Praha 9 - Koloděje +420 602 360 502 +420 602 360 501 +420 281 970 988 http://www.kralgroup.cz [email protected] [email protected] 003TP.03