Download MCPRO manual - Jorgensen, William L.

Transcript
IPRNT determines the verbosity of written output (0–6, least to most):
IPRNT = 0
IPRNT = 1
IPRNT = 2
IPRNT = 3
IPRNT = 4
IPRNT = 5
IPRNT = 6
Usual
Cases.
Also print solute coordinates.
Includes high-energy non-bonded pairs and SASA’s for all solute atoms.
Includes residue–residue and solvent–residue lists (use sparingly).
Includes non-bonded pairs list, residues without internal variations, and
energy information for each move (use VERY sparingly with small
MXCON!). For debugging only.
Includes solvent coordinates (ditto).
The next variable is MXCON (the 100000) which specifies the number of configurations for this run.
Keep it constant during averaging, i.e. after NEWRUN = 1. It is often advisable to perform some very
short runs at the beginning for a new system just to check that everything has been set up properly. For
example, with a 114 start just run 100 configurations or so (MXCON) and check the system graphically
by displaying the resultant plt file. Then restart with 011, if all is okay. Also, the initial energy may be
very high due to some overly short interatomic contacts. These are typically relieved within ca. 10K
configurations. It is also advisable not to perform volume moves initially (set NVCHG = 999999 in the
parameter file), e.g., for the first 300K of equilibration, since undesirable volume expansion may occur
to relieve the short contacts.
If ICALC = 2, MXCON has a different meaning. In this case, it is the maximum number of geometry
optimization cycles to be performed.
The final three variables (0.15 0.00 0.30) are RC0, RC1 and RC2 which define the reference and
two perturbed systems for free energy calculations. Normally, they range from 0 to 1, though other
values may be convenient for potential-of-mean-force computations. Geometrical and potential function
parameters are scaled linearly between initial and final values indicated in the ZMAT file as RC goes
from 0 to 1. RC0 is for the reference solute and RC1 and RC2 are for the two perturbed solutes that are
treated by the program. Thus, perturbations can be made in two directions (double-wide sampling). If a
free energy perturbation is being performed, the parameter and Z-matrix files can be set up so that for
new increments (change of RC0) only the command file requires change.
For complete perturbations, the command file needs three sections: equilibration, averaging, and
submission of the next job. The later typically includes copying the current in file to be the in file for the
next perturbation window. Test Job FEPaq illustrates this. For Linux/Unix only one command file is
needed, while for Windows a series of command files is required with one submitting the next. If a free
energy calculation is not being performed, set RC0 = RC1 = RC2.
14