6) STEP/DIR mode settings:
a. Overwrite enable input. When it is checked, controller ignores
STEP/DIR D-SUB15 connectors 3 pin (see “7.7 STEP/DIR
INTERFACE connector pin out.”) logic level. User can choose to
enable/disable motor in STEP/DIR operating mode.
b. Overwrite DIR input. When checked, controller ignores STEP/DIR
D-SUB15 connectors 2 pin (see “7.7 STEP/DIR INTERFACE
connector pin out.”) logic level. User can choose in which direction
motor turns when operating in STEP/DIR mode.
NOTE: By default this settings is turned off.
7) STEP/DIR current. When in STEP/DIR mode user can select current
value.
8) Read settings. Program reads settings from device.
9) Save settings. When user set desired values, it is saved in program, but
only for time when device is turned on. When device is turned off, it
automatically changes values to last saved. By clicking this button user
saves all setting in device, and they do not change if device is turned off.
NOTE: When user made some modifications in settings and it gives desired
effect, user must save it, because modified settings can be lost.
NOTE: User can reload default settings from a file (see “5. Firmware
upgrade”).
21