Download pilot User`s Manual
Transcript
AW00015119000 12.5.3 Features Free Selection Sequence Advance Mode When the free selection sequence advance mode is selected the advance from one sequence set to the next as frame start triggers are received does not adhere to a specific preset sequence: The sequence sets can be selected at will using the states of input lines: The states of the input lines set the sequence set addresses. These correspond to the sequence set index numbers and accordingly, the related sequence set is selected. For details about selecting sequence sets via the sequence set address, see the "Selecting Sequence Sets" section. The states of two input lines are checked if more than two sequence sets are available. The states of one input line is checked when only two sequence sets are available. The Sequence Set Total Number parameter specifies the total number of different sequence sets that are available. The maximum number is 4. 12.5.3.1 Operation Operating the Sequencer The following use case (see also Figure 64) illustrates the operation of the sequencer in free selection sequence advance mode. In this use case, the Sequence Set Total Number parameter was set to four. Accordingly, the sequence set index numbers range from 0 through 3. Input line 1 sets bit 0 of the sequence set address. Input line 2 sets bit 1 of the sequence set address. Both input lines are not set for invert. The frame start trigger is set for rising edge triggering. Assuming that the camera is in the process of continuously capturing images, the sequencer feature operates as follows: When the sequencer feature becomes enabled and a frame start trigger was received, the camera checks the states of input lines 1 and 2. Input line 1 is found to be high and input line 2 is found to be low. This corresponds to the address of sequence set 1. Accordingly, sequence set 1 is selected. Its parameter values are loaded into the active set and are used for the image acquisition. Note that the state of input line 1 went high well ahead of the frame start trigger. To ensure reliable selection of a sequence set, allow the elapse of at least one microsecond between setting the states of the input lines and the rise of the frame start trigger signal. Also, maintain the states of the input lines at least for one microsecond after the frame start trigger signal has risen. Note also that the camera briefly exits the "waiting for frame start trigger" status while an input line changes its state. This happened, for example, when input line 1 changed its state before the first frame start trigger was received (see also Figure 64). Basler pilot 251