Garment Maintenance Schedule Work to Be Performed Prior to Use Interval After each Annually use Every 2 years X Check by Wearer Cleaning X Garment Inspection X X Inflation Test (Level A) X X X X Exhaust Valve Diaphragm Inspection (Level A) Exhaust Valve Diaphragm Replacement (Level A) X As required Closure Lubrication Closure Lubricants You can lubricate a zipper or closure that is difficult to operate. You should apply paraffin wax or YKK Zippy Cool Lubricant lightly on the teeth of the closure. After lubrication, the zipper should be closed and opened a number of times to ensure smooth function and to remove excess lubricant. NOTE: EXCESSIVE FORCE OR IMPROPER TECHNIQUE CAN DAMAGE THE GAS-TIGHT ZIPPERS IN LEVEL A SUITS. When opening or closing the zipper, use one hand to hold the zipper assembly near the slider while pulling the slider in a direction that is parallel, close to and along the line of the zipper assembly. Excessive force and not pulling the slider in line with the zipper can lead to permanent damage to the zipper. Garment Inspection (applies to all categories of Tychem® garments) Tychem® Garment Inspection You must inspect all Tychem® garments at the following times: 1. Upon receipt from supplier 2. Before it is worn 7