Download Digital Super Hybrid System Programming Guide
Transcript
3.1 • • • • Manager Programming 30 through 39 are effective as MSN's. The extension user can call any terminal equipment on the ISDN S0 bus with MSN individually. Pressing "30" calls all extensions on the ISDN S0 bus simultaneously. Port numbers 01 through 06 are for the Master System, and 07 through 12 are for the Slave, if available. An extension number is invalid if the first or second digit does not match with the setting in programme [100] Flexible Numbering, 1st through 16th hundred extension blocks. Double entry and incompatible entry for these numbers are invalid. Valid entry example: 10 and 11, 10 and 110. Invalid entry example: 10 and 106, 210 and 21. To avoid making an invalid entry, check the other extension numbers. The default of each extension number is as follows: [003] Extension Number Set KX-TD816 – 101 through 116, 201 through 216 KX-TD1232 – 101 through 164, 201 through 264 [118] VM Extension Number Set KX-TD816 – 165 through 170, 177, 178, 181 through 184 KX-TD1232 – 165 through 188 [124] Phantom Extension Number Set Not stored. [813] Floating Number Assignment KX-TD816 – 191 through 194, 196, 198, 291 through 294, 298, 299 KX-TD1232 – 191 through 194, 196 through 198, 291 through 294, 296 through 299 Programme [013] ISDN Extension Name Set is used to give names to the extension numbers. Features Guide References Integrated Services Digital Network (ISDN) Extension ISDN Programming 285