Download CombiSump, Instruction Manual

Transcript
CombiSump
7.12
Mounting the delivery pipe
1 Fit the pump casing (1100) and, if there, the suction strainer (1160).
2 Fit the flange of the delivery pipe together with the gasket (8030) to the base plate.
3 Fit the flange of the delivery pipe together with the gasket (8030) to the pump casing.
!
The delivery pipe should always be mounted stress-free!
4 If the pump has intermediate bearings: Fit the pipe fasteners (7120) with bolts (7130)
and nuts (7135).
5 Mount the straight delivery pipe (8010), or the 90° bent delivery pipe (8020)
including gasket (8035) with the fixing bolts (8070).
6 Versions S3 and M2: Mount the flushing pipe (2130 or 2230).
CS/EN (1212) 5.3
Disassembly and assembly
39