Download Neutron Engineering Inc.

Transcript
Neutron Engineering Inc.
5.9.6 TEST RESULTS
E.U.T :
Temperature :
Pressure :
Test Mode :
3.5” SATA Mobile Rack
22℃
1015 hPa
SYSTEM LOAD
Model Name :
T-7-SA
Relative Humidity : 50%
Test Voltage :
AC 230V/50Hz
Test Mode
Test Level
Antenna
aspect
Duration
(s)
Perform
Criteria
Results
Enclosure
1 A/m
X
60 s
A
A
PASS
Enclosure
1 A/m
Y
60 s
A
A
PASS
Enclosure
1 A/m
Z
60 s
A
A
PASS
Judgment
Note:
1) N/A - denotes test is not applicable in this test report
2) Criteria A: There was no change operated with initial operating during the test.
3) Criteria B: The EUT function loss during the test, but self-recoverable after the test.
4) Criteria C: The system shut down during the test.
Report No.: NEI-EMC-1-0703C143A
Page 43 of 48