Download Modicon TSX Micro - Steven Engineering
Transcript
Modicon TSX Micro automation platform Characteristics (continued) 1 TSX 37 05/08/10/21/22 PLCs Processor chracteristics 1 Type of PLc No. of slots Functions (Max.no.) TSX 37 05 2 – 60 (28 I/O) 92 Basic With extension rack, 2 slots Discrete I/ Screw terminal block O(1) HE10 connector 64 channel modules Integrated Modules Type of modules Regulation Counting Integrated channels (2) Modules Type of modules Discrete I/O Integrated Serial link connections Type of links Networks Ethernet TCP/IP and bus Fipway network, connections Modbus Plus AS-Interface bus CANopen bus Modbus bus, Uni-Telway, Characters string Extension by Nano base and Nano extension (200 m maxi) Internal RAM which can be backed up Program and constants Data storage Max. data Internal bits %Mi storage size Internal words %MWi Constants words %KWi Application structure Master task Fast task Event processing Execution time Without Boolean for 1 instruction PCMCIA On word or fixed-point card arithmetic With Boolean PCMCIA On word or fixed-point card arithmetic No. of Without 100 % boolean K instructions PCMCIA executed by ms card 65 % boolean and 35 % numerical With 100 % boolean PCMCIA card 65 % boolean and 35 % numerical Overhead système Master task 88 (56 I/O) 120 TSX 37 10 2 4 124 (28 I/O) 184 (28 or 64 I/ O) 2 TSX 37 21 3 5 160 (–) 248 (–) TSX 37 22 1 3 – 8 I et 1 O 2 4 Half format module 4 or 8 I, 2 or 4 O, 4 I/O The number of loops is limited by the number of analogue modules and by the size of memory – 2 channel 10 kHz 2 2 (3) 4 (3) Half format module 1 or 2 channel 40/500 kHz, 1 channel SSI 1 MHz 2 channels 500 Hz 1 link with 1connector (TER) 19.2 Kbit/s 1 link with 2 connectors (TER and AUX) 19,2 Kbit/s Uni-Telway master/slave Modbus slave RTU Modbus master/slave RTU Character mode Character mode – 1 (Ethernet TCP/IP external module or RS 232 Modem) – 1 (4) Analog I/O Real time clock Memory Max. capacity TSX 37 08 3 – – – 1 Half format module (profil M2) (5) 1 (4) 1 (4) 1 (4) – 1 half-format module (5) for 96 discrete I/O or 12 analogue I/O (4 Nano bases 24 I/O or 3 analogue extensions 3 I/1 O) – Kwords 11 Kwords Kwords bits Kwords Words 14 20 128 with PCMCIA card 128 µs µs – – 256 1 (6) 128 (6) 1 1 8 0,25 4,81 µs µs – – 0,19 4,50 Kinst/ ms Kinst/ ms Kinst/ ms Kinst/ ms ms 3,03 5,88 0,25 0,27 – 4,00 – 0,266 1,9 1,6 1 (6), 17,5 with PCMCIA card 16 (where 1 has priority) 0,13 4,50 2,3 (1) The value in bracket and in italics corresponds to number of I/O providing with the basic PLC configuration. (2) Maximum number of couting/positioning channels, see page 3/16. (3) TSX CTZpp counting/positioning modules, only in the TSX Micro base. (4) PCMCIA to insert in the communication card slot (5) The remote discrete I/O extension modules and AS-Interface bus modules are installed in position 4 which means that their use is mutually exclusive. (6) Default size, can be extended, but will have an adverse effect on the size of the application program. Functions: pages 1/8 and 1/9 References: pages 1/15 and 1/16 Dimensions, mounting: page 1/17 1/14 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com