Download User`s Manual

Transcript
User's
Manual
3 Series
Coriolis Mass Flow and Density Meter
Integral Type RCCT3
Remote Type RCCF31 + RCCS3
European MID Custody Transfer Type (/Q01)
IM 01R04B07-00E-E, additional manual to IM 01R04B04-00x-E
Rota Yokogawa GmbH & Co. KG
Rheinstr. 8
D-79664 Wehr
Germany
IM 01R04B07-00E-E
December 2009 (Rü)
3rd edition, July 2013 (Rü)
©Copyright
Blank Page
CONTENTS
Contents
1. About Rotamass MID Custody Transfer Type (/Q01).........................1-1
2. INSTALLATION......................................................................................2-1
2.1 General ........................................................................................................................................... 2-1
2.2 Hardware Write Protect....................................................................................2-1
2.3 Sealing..............................................................................................................2-2
3. PARAMETER DESCRIPTION...............................................................3-1
3.1 Overview...........................................................................................................3-1
3.2 Parameter list...................................................................................................3-2
3.3 Parameter tree, Display menu......................................................................3-21
3.4 Parameter tree, HART menu.........................................................................3-52
3.5 Mass flow functions (Basic or Detailed Setup)..........................................3-84
3.6 Volume flow functions (Basic or Detailed Setup).......................................3-85
3.7 Density functions (Basic or Detailed Setup)..............................................3-86
3.8 Temperature functions (Basic or Detailed Setup)......................................3-88
3.9 Velocity functions (Detailed Setup)..............................................................3-88
3.10 Analog 1 functions (Basic or Detailed Setup)..........................................3-89
3.11 Pulse/Status output 1 functions (Basic or Detailed Setup).....................3-90
3.12 Pulse/Status output 2 functions (Basic or Detailed Setup)......................3-94
3.13 Status input functions (Basic or Detailed Setup).....................................3-95
3.14 HART output (Detailed Setup)....................................................................3-96
3.15 Totalizer functions (Basic or Detailed Setup)...........................................3-97
3.16 Flow direction function (Detailed Setup)...................................................3-98
3.17 Concentration measurement (Detailed Setup)..........................................3-99
3.18 Net flow (Detailed Setup)..........................................................................3-100
3.19 Slug detection (Detailed Setup)................................................................ 3-101
3.20 Empty pipe detection (Detailed Setup)....................................................3-102
3.21 Corrosion detection (Detailed Setup)......................................................3-103
3.22 Detector data (Detailed Setup).................................................................3-103
3.23 Reading maximum fluid temperature (Detailed Setup)..........................3-104
All Rights Reserved. Copyright © 2009, Rota Yokogawa
i
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
CONTENTS
Blank Page
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
ii
All Rights Reserved. Copyright © 2009, Rota Yokogawa
1. ABOUT ROTAMASS CUSTODY TRANSFER TYPE
1. About Rotamass MID Custody Transfer
Type (/Q01)
This user manual is additional to IM 01R04B04-00x-E for standard Rotamass 3 series.
This manual describes the special conditions for european MID custody transfer type (option /Q01) which
deviate from the standard flowmeter.
Chapters 1, 2, 3, 5, 6, 8, 9, 10, and 11 of IM 01R04B04-00x-E are also valid for Custody Transfer Type.
Chapter 2 of this manual replaces chapter 4 of IM 01R04B04-00x-E.
Chapter 3 of this manual replaces chapter 7 of IM 01R04B04-00x-E.
IMPORTANT
For explosion protected instruments and instructions for PED (Pressure Equipment Directive) see
IM 01R04B04-00x-E.
Rotamass with custody transfer option for liquids others than water (tested according OIML R 117-1) is
suitable for
-
-
-
measuring liquids, liquids with solid content, multi-phase mixtures
simultaneous measurement of density, temperature and cumulated mass and volume
connection to controllers and process control systems
ROTAMASS provides the following I/O-connections and can be configured for a wide variety of different
measurement applications (controlling, checking, monitoring, metering, mixing, filling).
- 1 passive double pulse output (90 degrees phase shifted according DIN EN 6551) for custody transfer
of total mass or volume
- 1 analog output for density (tested for custody transfer applications)
-
1 passive pulse output / status output
-
1 status input
The firmware is the same as in standard type. The Custody Transfer type contains the same menu tree as
standard type. But some parameters can generally not be used or can only not be used with custody transfer
application.
NOTE
Parameter which generally can not be used (e.g. because the necessary hardware is not available) are
highlighted in grey in the parameter list and in the menu trees.
Parameter which require special settings or where settings are restricted with custody transfer application are marked with a star " *) ".
For using the Rotamass with option /Q01 for custody transfer the flowmeter must be calibrated at a certified
calibration site.
All Rights Reserved. Copyright © 2009, Rota Yokogawa
1-1
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
1. ABOUT ROTAMASS CUSTODY TRANSFER TYPE
Initial verification:
- Before calibration all necessary adjustments must be done via menu setting.
- Hardware Write Protect must be set (see chapter 2.7).
- The flowmeter must be sealed (see chapter 2.8).
- Special density and flow DAKKS- calibration with water
- No density adjustment
Measuring ranges in custody transfer mode:
RCCx34
RCCx36
RCCx38
RCCx39
Qmin / Qmax
in kg/h
300 / 4020
780 / 15600
2400 / 49800
10020 / 132000
Minimum measured
quantity in kg
20
20
100
200
Operating conditions:
Maximum process pressure:
Process temperature range:
Ambient temperature range:
Environmental class:
Accuracy class:
Density range:
Mass flow low cut
in kg/h
60
156
480
2004
20 bar
-40°C ... +55°C
-40°C ... +55°C
M3 (e.g. truck mounting)
E3 (e.g. vehicle battery supply)
0.3; 0.5
(0.7 ... 1.4) kg/l
Outputs / Inputs in custody transfer mode:
Current output:
1 active, 4-20 mA
Pulse output:
1 passive, 2 channels A and B: 90° shifted pulse packets with pulse width 0.05 ms or 1 ms, optional NAMUR level
Status output:
1 passive, off-state to indicate faults and power loss
Status input:
1 passive
Measurement variables in custody transfer mode:
Mass (output on pulse output 1)
Volume (output on pulse output 1)
Density ((output on current output)
Since only one pulse output is available mass and volume can not be measured simultaneously!
Documentation for custody transfer:
Test Report
RCCF31
RCCS34
RCCS36
RCCS38
RCCS39
CPC-601228-01
CPC-900389-01
CPC-809370-01
CPC-809370-02
CPC-900389-01
Certificate
TC 7531
TC 7532
TC 7532
TC 7532
TC 7532
Documentation
Folder
TC 7531
TC 7532
TC 7532
TC 7532
TC 7532
Test reports, certificates and special documentation folders for national type approvals are available on
request. The numbers of the evaluation certificates of detector and converter according OIML R 117-1 and
european directive 2004/22/EC on measuring instruments (MID) are indicated on the name plates.
For integral type RCCT3x always order also the documentation for converter RCCF31.
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
1-2
All Rights Reserved. Copyright © 2009, Rota Yokogawa
2. INSTALLATION
2. INSTALLATION
2.1 General
For installation see chapter 4 of IM 01R04B04-00E-E.
Additional regard the following chapters 2.2 and 2.3 of this manual.
2.2 Hardware Write Protect
For use in custody transfer application the hardware write protection must be set after setup:
• Open the cover of the converter.
• Unscrew the 4 screws of the display and move the display aside.
• Set the jumper on JP1 of CPU-board as shown in the following picture.
• Screw the display and close the cover.
CPU Board
JP1
Cable to display
Enable
Protect
F64.EPS
The hardware write protection is prior to any other write protection, and cannot be released by HART or
other software means.
NOTE
If the Hardware Write Protect jumper is in the "Protect" position then all parameters and commands of the
list in chapter 3.2 and the menu trees in 3.3 and 3.4 can only be read in "Read only" mode.
Any writing or execution is impossible (message "Write protect"). Also Autozero is not possible.
Apply the correct value for density offset before sealing the housing!
This hardware protection can not be removed without breaking the sealing.
All Rights Reserved. Copyright © 2009, Rota Yokogawa
2-1
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
2. INSTALLATION
2.3 Sealing
Sealing is done by blocking the front window cover of the converter using the attached wire seal.
The wire of the wire seal is put through the holes of the cover and the housing as shown in the figure
below and then the wire is pulled through the seal again for fixing.
wire seal
IM 01R04B07-00E-E
3rd edition july 01, 2013-00
F44.EPS
holes
2-2
All Rights Reserved. Copyright © 2009, Rota Yokogawa
Mass
flow unit
Vol flow
unit
Density
unit
Temperature
unit
Velocity
unit
Hot key
(6.3)
Mass flow
(7.5)
Volume
flow (7.6)
Density
(7.7))
Temperature
(7.8)
Velocity
(7.9)
Analog
Output 1
(7.10)
Analog
Output 2
(7.11)
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-1
IM 01R04B07-00E-E
Sensor
model *)
Distributor
Poll
address
Detector
data (7.23)
Device
data
HART
data
Num req
preams
Tag
Num resp
preams
Long Tag
Sensor
S/N
Net flow
(7.19)
Concentration measurement
(7.18)
Flow
direction
(7.17) *)
Special
functions
Sensor
constants *)
Zero adjustment
(5.6)
Input/
Output Test
(8.4)
Self test/
status
(8.3)
Diag/Service (8)
Dips.
period
Total
mass unit
Disp.
contrast
Total flex
unit
TV is
Display
select
Total flex
select
Totalizer
(7.16)
SV is
Pulse 2
unit
Pulse 1
unit *)
Analog 1
low
LMT
Analog 2
low
LMT
Temperature
LRV
Density
LRV
Vol flow
LRV
Mass flow
LRV
New
Password
HART
Display
(5)
PV is
SI active
mode
SI
function
HART Output (7.15)
Pulse 2
select
Pulse/
Stat 2
select
Pulse/Status out 2
(7.13)
Status
input
(7.14)
Pulse 1
select *)
Pulse/
Stat 1
select *)
Pulse/Status out 1
(7.12)
Analog 1
alarm
out
Analog 2
alarm
out
Temperature
format
Density
format
Vol flow
format
Mass flow
format
Enable wrt
10min.
HART
Master
reset
Descriptor
Slug
detection
(7.20) *)
Autozero
(7.24)
Language
Total
volume
unit
QV is
Pulse 2
rate
Pulse 1
rate *)
Analog 1
high
LMT
Analog 2
high
LMT
Temperature
URV
Density
URV
Vol flow
URV
Mass
flow URV
Software
seal
HART
Message
Empty
pipe
detection
(7.21)
Output
trim
(8.5)
Total
net unit
Pulse 2
active
mode
Pulse 1
active
mode
Temperature
damping
Density
damping
Vol flow
damping
Mass
flow
damping
Key Status
HART
Date
Corrosion
detection
(7.22)
History
overview
(8.2)
Total
energy
unit
Pulse 2
width
Pulse 1
width *)
Temperature
alm 1 sel
Density
lowcut *)
Vol flow
lowcut *)
Mass
flow
lowcut *)
Dev id
Fluid
max.
Temp.
(7.25)
Error
history
(8.2)
Heat of
combustion
Pulse 2
at alarm
Pulse 1
at alarm
Temperature
alm 1 crit
Mass
flow alm
1sel
Vol flow
alm 1
sel
Density
alm
1 sel
Universal
rev
Gas
measurement
(7.26) *)
Heat of
combustion unit
SO2
function
SO1
function *)
Fld dev
rev
Total
switch
select
SO2 active mode
SO1
active
mode *)
Temperature
alm 2 crit
Software
rev
Total limit
switch
Temperature fix val
select *)
Density
alm
2 crit
Density
alm
2 sel
Density
alm
1 crit
Temperature
alm 2 sel
Vol flow
alm 2 crit
Mass flow
alm 2 crit
Vol flow
alm 2 sel
Mass flow
alm
2 sel
Vol flow
alm 1 crit
Mass flow
alm1 crit
Hardware Write Protect
(6.4)
Parameters
Hardware
rev
Total at
alarm
Temperature fixed
value *)
Ref. Density sel *)
MF fix val
sel *)
Device S/W
version
Total
reset cntrl
Temperature
Gain adjust *)
Reference
density *)
MF fixed
value *)
Device
S/W date
Total
reset
Density
offset *)
Static
pressure
control
Not available for Custody Transfer type
Analog 2
select
Analog 1
select *)
Write
Protect
HART
Topic
3. PARAMETER DESCRIPTION
3. PARAMETER DESCRIPTION
3.1 Overview
The table below shows an overview of functions of ROTAMASS RCCT3/RCCF31/RCCR31.
In brackets the related chapters in this manual are indicated.
*) = Not for Custody Transfer type or special setting requested
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Differences between display and HART setting
The ROTAMASS software is continuously improved. This leads to functions, which are different in
HART (DD version 0402) and display setting (software version from 1.08.20)
NOTE
For ROTAMASS with software version 1.08.xx (xx < 20) the parameters marked with "**)" are not
available. Parameters marked with "***)" are not available in software version 1.08.20.
3.2 Parameter list
Parameter
Write protect
Data form
Select
Data range
No
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
-
Yes
Enable WRT 10 min
Acc. To HART
-
-
R/W
X
Disable
New Password
ASCII
8 characters
-
-
R/W
X
Space
Software Seal
Select
Break
-
-
R/W
-
-
R/W
-
-
R/W
-
-
R/W
-
Keep
Master reset
Select
Not Execute
X
Not Execute
Execute
Key Status
Select
Language
Select
Enable
Enable
Inhibit
English
X
English
German
French
Russian
Mass Flow
Decimal
-
0 to 5
Mass flow unit
R
-
-
Volume Flow
Decimal
-
0 to 5
Vol flow unit
R
-
-
Density
Decimal
-
0 to 5
Density unit
R
-
-
Temperature
Decimal
-
0 to 5
Temperature unit
R
-
-
F-Total flex
Decimal
-
Auto
Total flex unit
R
X
-
-
R-Total flex
Decimal
-
Auto
Total flex unit
R
X
-
-
D-Total flex
Decimal
-
Auto
Total flex unit
R
X
-
-
F-Total mass
Decimal
-
Auto
Total mass unit
R
X
-
-
R-Total mass
Decimal
-
Auto
Total mass unit
R
X
-
-
D-Total mass
Decimal
-
Auto
Total mass unit
R
X
-
-
F-Total vol
Decimal
-
Auto
Total volume unit
R
X
-
-
R-Total vol
Decimal
-
Auto
Total volume unit
R
X
-
-
D-Total vol
Decimal
-
Auto
Total volume unit
R
X
-
-
F-Total net
Decimal
-
Auto
Total net unit
R
X
-
-
R-Total net
Decimal
-
Auto
Total net unit
R
X
-
-
D-Total net
Decimal
-
Auto
R
X
-
-
Concentration meas
Decimal
0 to 110
0 to 5
-
-
Net flow
Decimal
-
0 to 5
Total net unit
Concentration
meas unit
Mass flow unit
-
-
F-Total energy
Decimal
-
Auto
Total unit energy
R
-
-
Velocity
Decimal
-
Auto
Velocity unit
R
-
-
Drive gain
Decimal
0 to 11 (typ.)
R
-
-
Decimal
-
As sel. Var.
R
-
-
Analog output 1%
Decimal
-
3
As sel.
Var.
2
V
Analog output 1
%
R
-
-
Analog output 1 mA
Decimal
-
2
mA
R
-
-
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-2
R
R
X
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
Data form
Data range
Dec.
point
Analog output 2
Decimal
-
Analog output 2%
Decimal
-
as sel.
Var.
2
Analog output 2 mA
Decimal
-
Pulse output 1
Decimal
-
Status output 1
ASCII
Pulse output 2
Status output 2
Unit
R : read
W : write
Exe :
execute
Reset
Master
Reset
Power on
Default
as sel. Var.
R
-
-
%
R
-
-
2
mA
R
-
-
1
Hz
R
-
-
-
-
-
R
-
-
Decimal
-
1
Hz
R
-
-
ASCII
-
-
-
R
-
-
View input
ASCII
-
-
-
R
-
-
Self Test
Select
Not Execute
-
-
R/W
X
Not Execute
Execute
Status
ASCII
Results of last self test
-
-
R
-
-
Hist Overview ord
ASCII
-
-
-
R
-
-
Hist Overview abs
ASCII
-
-
-
R
-
-
Error History
ASCII
-
-
-
R
-
-
Analog output 1 (Test)
Decimal
2.0 to 22.0
2
mA
W
X
X
4
Analog output 2 (Test)
Decimal
2.0 to 22.0
2
mA
W
X
X
4
Pulse output 1 (Test)
Decimal
0 to 10000
1
Hz
W
X
X
1000
Status Output 1 (Test) *)
Select
On Active
-
-
W
X
X
On Active
Off Active
Pulse output 2 (Test)
Decimal
0 to 2000
1
Hz
W
X
X
1000
Status Output 2 (Test)
Select
On Active
-
-
W
X
X
On Active
Off Active
Status input (Test)
ASCII
Open/Short
-
-
R
-
-
Autozero tuning
Select
Inhibit
-
-
R/W
X
X
Inhibit
-
-
R/W
X
X
3 min
-
-
Exe
X
X
Not Execute
Enable
Autozero Time
Select
3 min
30 s
Autozero Exe
Select
Not Execute
Execute
Autozero Value
Decimal
depends on size
3
kg/h
R
X
Autozero History
ASCII
-
-
-
R
X
-
-
Autozero initial
Decimal
depends on size
3
kg/h
R
X
-
-
Autozero range
Decimal
depends on size
3
kg/h
R
-
-
Autozero fluctuation range
Decimal
depends on size
3
kg/h
R
-
-
Output Trim AO 1 trim 4mA
Decimal
ACC To HART
-
-
R/W
-
0
Output Trim AO 2 trim 4mA
Decimal
ACC To HART
-
-
R/W
-
0
Output Trim AO 1 trim
20mA
Decimal
ACC To HART
-
-
R/W
-
0
Output Trim AO 2 trim
20mA
Decimal
ACC To HART
-
-
R/W
-
0
Tag
ASCII
8 characters
-
-
R/W
Space
Long Tag
ASCII
22 characters
-
-
R/W
Space
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-3
X
IM 01R04B07-00E-E
0
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
Disp select 1
Data form
Select
Data range
Mass flow
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
-
-
R/W
Reset
Master
Reset
Power on
Default
X
Mass flow
X
Density
Volume flow
Density
Temperature
Concentration
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
Disp select 2
Select
Mass flow
Volume flow
Density
Temperature
Concentration
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-4
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
Disp select 3
Data form
Select
Data range
Mass flow
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
-
-
R/W
Reset
Master
Reset
Power on
Default
X
Temperature
X
F-Total mass
Volume flow
Density
Temperature
Concentration
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
Disp select 4
Select
Mass flow
Volume flow
Density
Temperature
Concentration
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-5
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
Data form
Disp contrast
Select
Data range
-5
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
-
-
R/W
X
1.0 s
-
-
R/W
X
Forward
-
-
R/W
X
RCCS30LR
…33: l/h
X
0
-4
-3
-2
-1
0
1
2
3
4
5
Disp Period
Select
0.5 s
1.0 s
2.0 s
Flow direction *)
Select
Forward
Reverse
Mass flow unit
Select
g/s
g/min
RCCS34…39/
XR: m³/h
g/h
kg/s
kg/min
kg/h
kg/d
t/min
t/h
t/d
lb/s
lb/min
lb/h
lb/d
Mass flow format
Select
xxxxxxx
-
-
R/W
X
xxxx.XX
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Mass flow LRV
Decimal
-Qmax to Qmax
0 to 5
Mass flow unit
R/W
X
0
Mass flow URV
Decimal
-Qmax to Qmax
0 to 5
Mass flow unit
R/W
X
Qnom
Mass flow damping
Decimal
0 to 200
1
Sec.
R/W
X
3
Mass flow lowcut *)
Decimal
-Qmax to Qmax
0 to 5
Mass flow unit
R/W
X
0
Mass flow alm 1 sel
Select
No function
-
-
R/W
X
No function
More than
Less than
Mass flow alm 1 crit
Decimal
-110% to 110% of URV
0 to 5
Mass flow unit
R/W
X
0
Mass flow alm 2 sel
Select
No function
-
-
R/W
X
No function
More than
Less than
Mass flow alm 2 crit
Decimal
-110% to 110% of URV
0 to 5
Mass flow unit
R/W
X
10
Mass flow fix val sel *)
Select
Inhibit
-
-
R/W
X
Inhibit
0 to 5
Mass flow unit
R/W
X
0
Enable
Mass flow fixed val *)
IM 01R04B07-00E-E
Decimal
0 to Qnom
3rd edition July 01, 2013-00
3-6
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
Vol flow unit
Data form
Select
Data range
cm³/s
Dec.
point
-
Unit
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
X
cm³/min
Reset
Power on
Default
RCCS30LR
…33: l/h
RCCS34…39/
XR: m³/h
cm³/h
l/s
l/min
l/h
l/d
m³/s
m³/min
m³/h
m³/d
gal/s
gal/min
gal/h
gal/d
Cuft/s
Cuft/min
Cuft/h
Cuft/d
bbl/s
bbl/min
bbl/h
bbl/d
lmpgal/s
lmpgal/min
lmpgal/h
Impgal/d
l(N)/s *)
l(N)/min *)
l(N)/h *)
l(N)/d *)
m³(N)/s *)
m³(N)/min *)
m³(N)/h *)
m³(N)/d *)
Sl/s *)
Sl/min *)
Sl/h *)
Sl/d *)
Scuft/s *)
Scuft/min *)
Scuft/h *)
Scuft/d *)
Sm³/s *)
Sm³/min *)
Sm³/h *)
Sm³/d *)
Vol flow format
Select
xxxxxxx
-
-
R/W
X
xxxx.XX
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-7
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
Data form
Data range
Dec.
point
Unit
Vol flow LRV
Decimal
-Qvmax to Qvmax
0 to 5
Vol flow unit
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
Vol flow URV
Decimal
-Qvmax to Qvmax
0 to 5
Vol flow unit
R/W
X
Qvnom
Vol flow damping
Decimal
0 to 200
1
Sec.
R/W
X
3
Vol flow lowcut *)
Decimal
-Qvmax to Qvmax
0 to 5
Vol flow unit
R/W
X
0
Vol flow alm 1 sel
Select
No function
-
-
R/W
X
No function
X
0
More than
Less than
Vol flow alm 1 crit
Decimal
-110% to 110% of URV
0 to 5
Vol flow unit
R/W
X
0
Vol flow alm 2 sel
Select
No function
-
-
R/W
X
No function
More than
Less than
Vol flow alm 2 crit
Decimal
-110% to 110% of URV
0 to 5
Vol flow unit
R/W
X
10
Density unit
Select
g/ml
-
-
R/W
X
kg/l
-
-
R/W
X
xx.XXXX
kg/l
kg/m³
lb/gal
lb/Cuft
g/cm³
g/l
°Bé hv *)
°Bé lt *)
°API *)
Density format
Select
xxxxxxx
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Density LRV
Decimal
0 to 5 kg/l
0 to 5
Density unit
R/W
X
0.0
Density URV
Decimal
0 to 5 kg/l
0 to 5
Density unit
R/W
X
1.5
Density damping
Decimal
0 to 200
1
Sec.
R/W
X
15.0
Density lowcut *)
Decimal
0 to 5 kg/l
0 to 5
Density unit
R/W
X
0.0
Density alm 1 sel
Select
No function
-
-
R/W
X
No function
More than
Less than
Density alm1 crit
Decimal
0 to 5 kg/l
0 to 5
Density unit
R/W
X
LRV
Density alm 2 sel
Select
No function
-
-
R/W
X
No function
More than
Less than
Density alm 2 crit
Decimal
0 to 5 kg/l
0 to 5
Density unit
R/W
X
URV
Ref. Density sel *) **)
Select
Inhibit
-
-
R/W
X
Inhibit
-
-
R/W
X
Inhibit
Fixed
Calculated
Density fix val sel *) ***)
Select
Inhibit
Enable *)
Reference Density *)
Decimal
0 to 5 kg/l
0 to 5
Density unit
R/W
X
1.0
Density offset *)
Decimal
-9999.99 to +9999.99
2
g/l
R/W
X
0
Pressure
Decimal
0 to 400
2
bar
R/W
0
Pressure unit
Select
bar
-
-
R/W
bar
psi
MPa
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-8
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
Temperature unit
Data form
Select
Data range
degC
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
-
-
R/W
X
xxxxxx.X
0 to 5
Temperature unit
R/W
X
-200
0 to 5
Temperature unit
R/W
X
230
X
degC
degF
K
Temperature format
Select
xxxxxxx
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Temperature LRV
Decimal
Standard: -200 to 230°C
High Temp.: 0 to 400°C
Temperature URV
Decimal
Standard: -200 to 230°C
High Temp.: 0 to 400°C
Temperature damping
Decimal
0 to 200
1
Sec.
R/W
X
3
Temp alm 1 sel
Select
No function
-
-
R/W
X
No function
More than
Less than
Temp alm 1 crit
Decimal
Standard: -200 to 200°C
0 to 5
Temperature unit
R/W
X
LRV
Temp alm 2 sel
Select
No function
-
-
R/W
X
No function
0 to 5
Temperature unit
R/W
X
URV
-
-
R/W
X
X
Inhibit
1
Temperature unit
R/W
X
X
30
More than
Less than
Temp alm 2 crit
Decimal
Standard: -200 to 230°C
High Temp.: 0 to 400°C
Temp fix val select *)
Select
Inhibit
Enable
Temp fixed val *)
Decimal
Standard: -200 to 230°C
High Temp.: 0 to 400°C
Temp gain *)
Decimal
0.8 to 1.2
3
-
R/W
Velocity unit
Select
m/s
-
-
R/W
X
1
m/s
-
-
R/W
X
Mass flow
-
-
R/W
X
<3.6mA
ft/s
Analog 1 select *)
Select
Mass flow
Volume flow
Density
Temperature
Concentration meas
Net flow
None
Analog 1 alarm out
Select
<2.4mA
<3.6mA
4.0mA
>21mA
>21.6mA
Hold
Measured Value
Analog 1 low LMT
Decimal
2.4 to 21.6 mA
2
mA
R/W
X
3.8
Analog 1 high LMT
Decimal
2.4 to 21.6 mA
2
mA
R/W
X
20.5
Analog 2 select
Select
Mass flow
-
-
R/W
X
Density
Volume flow
Density
Temperature
Concentration meas
Net flow
None
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-9
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
Analog 2 alarm out
Data form
Select
Data range
<2.4mA
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
X
<3.6mA
<3.6mA
4.0mA
>21mA
>21.6mA
Hold
Measured Value
Analog 2 low LMT
Decimal
2.4 to 21.6 mA
2
mA
R/W
X
3.8
Analog 2 high LMT
Decimal
2.4 to 21.6 mA
2
mA
R/W
X
20.5
Pulse/Stat 1 select *)
Select
Pulse
-
-
R/W
X
Pulse
-
-
R/W
X
F-Total mass
-
-
R/W
X
kg/P
Status out *)
No function *)
Pulse 1 select *)
Select
Mass flow
Volume flow
Density
Temperature
Concentration
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net *)
R-Total net *)
Pulse 1 unit *)
Select
Hz
g/P
kg/P *)
t/P *)
lb/P *)
cm³/P
l/P *)
m³/P *)
gal/P *)
kgal/P *)
Cuft/P *)
bbl/P *)
lmpgal/P *)
klmpgal/P *)
l(N)/P *)
m³(N)/P *)
SI/P *)
Scuft/P *)
Sm³/P *)
Pulse 1 rate *) *)
Decimal
0 to 11000 Unit/ P
0 to 10000 Hz
0 to 5
0
Pulse 1 unit
R/W
X
1 kg/P
Pulse 1 active mode
Select
On Active
-
-
R/W
X
On Active
Off Active
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-10
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
Pulse 1 width *)
Data form
Select
Data range
0.05ms
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
-
-
R/W
X
0P/Hz
-
-
R/W
X
No function
-
-
R/W
X
On Active
-
-
R/W
X
Status out
X
1ms
0.1ms *)
0.5ms *)
1ms
5ms *)
10ms *)
50ms *)
100ms *)
500ms *)
1000ms *)
Pulse 1 at alarm
Select
0P/0Hz
Measured Value
Hold
SO 1 function *)
Select
No function
Flow-Direction
Total limit switch
Mass flow alm 1
Mass flow alm 2
Mass flow alm 1+2
Vol flow alm 1
Vol flow alm 2
Vol flow alm 1+2
Density alm 1
Density alm 2
Density alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Concentr. meas alm 1
Concentr. meas alm 2
Concentr. meas alm 1+2
Net flow alm 1
Net flow alm 2
Net flow alm 1+2
Slug alarm
Empty alarm
Corrosion alarm
All alarms
All errors
All alarms & errors
SO 1 active mode *)
Select
On Active
Off Active
Pulse/Stat 2 select
Select
Pulse
Status out
No function
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-11
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
Pulse 2 select
Data form
Select
Data range
Mass flow
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
-
-
R/W
X
Hz
X
Temperature
Volume flow
Density
Temperature
Concentration
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net
R-Total net
Pulse 2 unit
Select
Hz
g/P
kg/P
t/P
lb/P
cm³/P
l/P
m³/P
gal/P
kgal/P
Cuft/P
bbl/P
lmpgal/P
klmpgal/P
l(N)/P *)
m³(N)/P *)
SI/P *)
Scuft/P *)
Sm³/P *)
Pulse 2 rate
Decimal
0 to 11000 Unit/P
0 to 2000 Hz
0 to 5
0
Pulse 2 unit
R/W
X
2000 Hz
Pulse 2 active mode
Select
On Active
-
-
R/W
X
On Active
-
-
R/W
-
-
R/W
Off Active
Pulse 2 width
Select
0.05ms
1ms
0.1ms
0.5ms
1ms
5ms
10ms
50ms
100ms
500ms
1000ms
Pulse 2 at alarm
Select
0P/0Hz
X
0P/0Hz
Measured Value
Hold
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-12
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
SO 2 function
Data form
Select
Data range
No function
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
-
-
R/W
X
On active
-
-
R/W
X
Mass flow
X
No Function
Flow-Direction
Total limit switch
Mass flow alm 1
Mass flow alm 2
Mass flow alm 1+2
Vol flow alm 1
Vol flow alm 2
Vol flow alm 1+2
Density alm 1
Density alm 2
Density alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Concentr. meas alm 1
Concentr. meas alm 2
Concentr. meas alm 1+2
Net flow alm 1
Net flow alm 2
Net flow alm 1+2
Slug alarm
Empty alarm
Corrosion alarm
All alarms
All errors
All alarms & errors
SO 2 active mode
Select
On active
Off active
PV is
Select
Mass flow
Volume flow
Density
Temperature
Concentration meas
Net flow
None
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-13
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
SV is
Data form
Select
Data range
Mass flow
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
-
-
R/W
Reset
Master
Reset
Power on
Default
X
Density
X
F-Total mass
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
TV is
Select
Mass flow
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-14
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
QV is
Data form
Select
Data range
Mass flow
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
-
-
R/W
X
No function
-
-
R/W
X
On Active
-
-
R/W
X
Flex total
X
Temperature
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
SI function
Select
No function
Autozero
Reset flex totals
Reset mass totals
Reset volume totals
Reset net totals
Reset all totals
0% Signal lock
SI Active mode
Select
On active
Off active
Total flex select
Select
Flex total
Mass total
Volume total
Net total
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-15
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
Total flex unit
Data form
Select
Data range
g
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
-
-
R/W
X
kg
-
-
R/W
X
l
-
-
R/W
X
kg
-
-
R/W
X
Mass
X
kg
kg
t
lb
cm³
l
m³
gal
kgal
Cuft
bbl
Impgal
klmpgal
I(N) *)
m³(N) *)
SI *)
Scuft *)
MMscuft *)
Sm³ *)
Total mass unit
Select
g
kg
t
lb
Total volume unit
Select
cm³
l
m³
gal
kgal
Cuft
bbl
Impgal
klmpgal
I(N) *)
m³(N) *)
SI *)
Scuft *)
MMscuft *)
Sm³ *)
Total net unit
Select
g
kg
t
lb
cm³
l
m³
gal
kgal
Cuft
bbl
Impgal
klmpgal
Total switch select
Select
Mass
Volume
Net
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-16
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
Data form
Data range
Dec.
point
Unit
Total limit switch
Decimal
0 to 9999999
0 to 5
Total unit
R : read
W : write
Exe :
execute
R/W
Total unit energy
Select
MJ
-
-
R/W
Reset
Master
Reset
Power on
Default
X
0
X
MJ
Btu
Energy factor/ heat of
combustion
Energy factor/ heat of
combust unit
Decimal
0 to 100000
0 to 5
heat of combust
unit
R/W
Select
MJ/kg
-
-
R/W
X
MJ/kg
-
-
R/W
X
Hold
-
-
R/W
X
Inhibit
-
-
R/W
X
10
Btu/lb
MJ/m³(N) *)
Btu/Scuft *)
Total at alarm
Select
Hold
Continue Total
Total reset cntrl
Select
Inhibit
Enable
Total reset
Select
Not Execute
X
Not Execute
Reset flex totals
Reset mass totals
Reset volume totals
Reset net totals
Reset all totals
SK20 *)
Decimal
0 to 5
MHz×kg/h
R/W
124
SKT *)
Decimal
0 to 5
E-4×1/K
R/W
-7,34
SKTK *)
Decimal
0 to 5
E-7×1/K2
R/W
19,6
RV *)
Decimal
0 to 5
%/(kg/l)
R/W
0,24
Qnom *)
Decimal
auto
Mass flow unit
R
10
KD *)
Decimal
0 to 5
kg/l
R/W
4,4
fl20 *)
Decimal
0 to 5
Hz
R/W
177,1
FTC1 *)
Decimal
0 to 5
E-4×1/K
R/W
-2,179
FTCK *)
Decimal
0 to 5
E-7×1/K2
R/W
-0,539
SKP *)
Decimal
0 to 5
E-4×1/bar
R/W
-0,346
SKPT *)
Decimal
0 to 5
E-7×1/(bar×K)
R/W
0
FPC *)
Decimal
0 to 5
E-4×1/bar
R/W
0,173
FPTC *)
Decimal
0 to 5
E-7×1/(bar×K)
R/W
0,02
FQC1 *)
Decimal
0 to 5
E-10×s/g
R/W
0
FQC2 *)
Decimal
0 to 5
E-13×(s/g)2
R/W
-40,8
Poll Adress
Decimal
0
-
R/W
0
Num req pream
Decimal
0
-
R
5
Num resp pream
Decimal
0
-
R/W
Reference temperature
Decimal
1
Temperature unit
R/W
X
25
Ref. density carrier
Decimal
0 to 5
Density unit
R/W
X
0,997
Temp. coeff. a carrier
Decimal
0 to 5
E-3×(1/Temp unit)
R/W
X
-0,261
Temp. coeff. b carrier
Decimal
0 to 5
E-5×(1/Temp unit2)
R/W
X
-0,36
Ref. density product
Decimal
0 to 5
Density unit
R/W
X
0
Temp. coeff. a product
Decimal
0 to 5
E-3×(1/Temp unit)
R/W
X
0
Temp. coeff. b product
Decimal
0 to 5
E-5×(1/Temp unit2)
R/W
X
0
Temp. coeff. a **)
Decimal
0 to 5
E-3×(1/Temp unit)
R/W
X
0
Temp. coeff. b **)
Decimal
0 to 5
E-5×(1/Temp unit2)
R/W
X
0
Concentration meas unit
Select
-
-
R/W
X
Wt-%
0 to 15
5 to 20
°Brix
5
Wt -% sol
X
Vol % sol
X
Wt -%
X
Vol %
X
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-17
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
Data form
Concentration meas format
Select
Data range
xxxxxxx
Dec.
point
-
Unit
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
X
xxxxx.X
X
xxxx.XX
X
xxx.XXX
X
xx.XXXX
X
x.XXXXX
Reset
Power on
Default
xxxx.XX
X
Concentration meas LRV
Decimal
0 to 110
0 to 5
Concentration
meas unit
Concentration meas URV
Decimal
0 to 110
0 to 5
Concentration
meas unit
R/W
X
100
Concentration meas Damp
Decimal
0 to 200
1
Sec
R/W
X
10
Concentration meas lowcut
Decimal
0 to 10%
0 to 5
Concentration
meas unit
R/W
Conc meas alm 1 sel
Select
No function
-
-
R/W
X
No function
R/W
X
0
0
More than
Less than
Conc meas alm 1 crit
Decimal
0 to 110% of URV
0 to 5
Concentration
meas unit
R/W
X
LRV
Conc meas alm 2 sel
Select
No function
-
-
R/W
X
No function
More than
Less than
Conc meas alm 2 crit
Decimal
0 to 110% of URV
0 to 5
Concentration
meas unit
R/W
X
URV
Net flow select
Select
Mass
-
-
R/W
X
Mass
Volume
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-18
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Parameter
Net flow unit
Data form
Select
Data range
g/s
Dec.
point
-
Unit
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
X
g/min
Reset
Power on
Default
RCCS30LR-33:
kg/h
RCCS34-39/
XR: t/h
g/h
kg/s
kg/min
kg/h
t/min
t/h
lb/s
lb/min
lb/h
cm³/s
cm³/min
cm³/h
l/s
l/min
l/h
l/d
m³/s
m³/min
m³/h
m³/d
gal/s
gal/min
gal/h
gal/d
Cuft/s
Cuft/min
Cuft/h
Cuft/d
bbl/s
bbl/min
bbl/h
bbl/d
lmpgal/s
lmpgal/min
lmpgal/h
Impgal/d
Net flow format
Select
xxxxxxx
-
-
R/W
X
xxxx.XX
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Net flow LRV
Decimal
-Qmax to Qmax
0 to 5
Net flow unit
R/W
X
0
Net flow URV
Decimal
-Qmax to Qmax
0 to 5
Net flow unit
R/W
X
Qnom
Net flow damping
Decimal
0 to 200
1
Sec
R/W
X
3
Net flow lowcut
Decimal
-Qmax to Qmax
0 to 5
Net flow unit
R/W
X
0.0
Net flow alm 1 sel
Select
No function
-
-
R/W
X
No function
0 to 5
Net flow unit
R/W
X
LRV
More than
Less than
Net flow alm 1 crit
Decimal
-110% to 110% of URV
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-19
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Parameter
Net flow alm 2 sel
Data form
Select
Data range
No function
Dec.
point
Unit
-
-
R : read
W : write
Exe :
execute
R/W
Reset
Master
Reset
Power on
Default
X
No function
X
URV
More than
Less than
Net flow alm 2 crit
Decimal
-110% to 110% of URV
0 to 5
Net flow unit
R/W
Measuring range
Select
Namur
-
-
R
-
-
R/W
Namur
Not Namur
Slug alarm select *)
Select
Not Apply
X
Not Apply
Apply
Drive gain *)
Decimal
0 to 11 (typ.)
3
V
R
Slug criteria *)
Decimal
0 to 13.3
3
V
R/W
X
11
Slug duration *)
Decimal
0 to 120
0
Sec.
R/W
X
After slug
Select
Measured value
-
-
R/W
X
1
Measured
value
Drive gain damping
Decimal
0 to 200
1
Sec.
R/W
X
1
Empty pipe alm sel
Select
Not Apply
-
-
R/W
X
Not Apply
Hold
Apply
Empty pipe crit
Decimal
0 to Density URV
0 to 5
Density unit
R/W
X
0
After empty pipe
Select
Massflow=Zero
-
-
R/W
X
Massflow=
Measured value
Zero
Hold
Corrosion alm sel
Select
Not Apply
-
-
R/W
X
Not Apply
Apply
Corrosion criteria
Decimal
0 to Density URV
0 to 5
Density unit
R/W
X
1,5
Corrosion damp
Decimal
0 to 10
1
h
R/W
X
10
Fluid max temp
Decimal
-
1
Temperature unit
R
-
Distributor
ASCII
-
-
-
R
Yokogawa
Descriptor
ASCII
16 characters
-
-
R/W
Space
Message
ASCII
32 characters
-
-
R/W
Space
Date
ASCII
dd/mm/yyyy
-
-
R/W
01/01/2011
Sensor model *)
Select
RCCS30LR *)
-
-
R/W
RCCS36
RCCS30 *)
RCCS31 *)
RCCS32 *)
RCCS33 *)
RCCS34
RCCS36
RCCS38
RCCS39
RCCS39/IR *)
RCCS39/XR *)
Sensor S/N
Decimal
7 digits
-
-
R
0 (not used)
Assembly number
Decimal
7 digits
-
-
R
0 (not used)
Serial no. Converter
ASCII
16 char.
-
-
R
fix
Serial no. Detector
ASCII
16 char.
-
-
R
fix
Universal rev
Decimal
7 digits
-
-
R
fix
Fld. dev rev.
Decimal
3 digits
-
-
R
fix
Software rev
Decimal
3 digits
-
-
R
fix
Hardware rev
Decimal
3 digits
-
-
R
fix
Device id
Decimal
7 digits
-
-
R
Device S/W version
ASCII
20 char.
-
-
R
Device S/W date
ASCII
dd/mm/yyyy
-
-
R
7xxxxxx
RCCT3
Vx.xx.xx
Rx-x-x
xx/xx/xxxx
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-20
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
3.3 Parameter tree, Display menu
Language
English
German
French
Russian
Process
View fld dev vars
Variables
View outputs
Mass flow
R
Volume flow
R
Density
R
Temperature
R
Concentration meas
R
Net flow
R
F-Total flex
R
R-Total flex
R
D-Total flex
R
F-Total mass
R
R-Total mass
R
D-Total mass
R
F-Total volume
R
R-Total volume
R
D-Total volume
R
F-Total net
R
R-Total net
R
D-Total net
R
F-Total energy
R
Velocity
R
Drive gain
R
Analog output 1
Analog output 2
Pulse/Status out 1
Pulse/Status out 2
Analog Output 1
R
Analog Output 1%
R
Analog Output 1mA
R
Analog Output 2
R
Analog Output 2%
R
Analog Output 2mA
R
Pulse output 1
R
Status output 1
R
Pulse output 2
R
Status output 2
R
View input
Totalizer
R
Total reset cntrl
Inhibit
Sel
Enable
Total reset
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-21
Not Execute
Reset flex totals
EXE
Reset mass totals
EXE
Reset volume totals
EXE
Reset net totals
EXE
Reset all totals
EXE
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Diag/Service
Self test/Status
Self Test
Status
Hist Overfiew ord
Hist Overfiew abs
Input/Output test
Auto zero check
Autozero
LCD Test
EXE
Self Test
EXE
Key Test
EXE
Event Overview
R
Error
R
Alarm
R
Warning
R
Hist Overview ord
R
Clear History
EXE
Hist Overview abs
R
Error
R
Alarm
R
Warning
R
Clear History
EXE
Error History
R
Analog output 1
R/W
Analog output 2
R/W
Pulse output 1
R/W
Status output 1 *)
R/W
Pulse output 2
R/W
Status output 2
R/W
Status input
R
Autozero history
R
Autozero initial
R
Autozero range
R
Autozero fluctuation
range
R
Zero tuning
Inhibit
Sel
Enable
Autozero time
3min
Sel
30s
Output trim
IM 01R04B07-00E-E
Autozero Exe
EXE
Autozero value
R
AO 1 trim 4mA
EXE
AO 1 trim 20mA
EXE
AO 2 trim 4mA
EXE
AO 2 trim 20mA
EXE
3rd edition July 01, 2013-00
3-22
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup
Tag
R/W
Long Tag
R/W
Display config
Disp select 1
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
Disp select 2
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-23
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Basic Setup
Disp select 3
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
Disp select 4
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-24
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup
Display contrast
-5
Sel
-4
-3
-2
-1
0
+1
+2
+3
+4
+5
Mass flow
Mass flow unit
g/s
Sel
g/min
g/h
kg/s
kg/min
kg/h
kg/d
t/min
t/h
t/d
lb/s
lb/min
lb/h
lb/d
Density
Mass flow LRV
R/W
Mass flow URV
R/W
Mass flow damping
R/W
Density unit
g/ml
Sel
kg/l
kg/m³
lb/gal
lb/Cuft
g/cm³
g/l
°Bé hv *)
°Bé lt *)
°API *)
Density LRV
R/W
Density URV
R/W
Density damping
R/W
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-25
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Basic Setup
Temperature
Temperature unit
degC
Sel
degF
K
Analog 1 select *)
Temperature LRV
R/W
Temperature URV
R/W
Temperature damping
R/W
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
Analog 2 select
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
Pulse/Status out 1
Pulse/Stat 1 select
Pulse
Sel
Status Out *)
No Function *)
Pulse 1 select
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net
R-Total net
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-26
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup
Pulse 1 unit
Hz
Sel
g/P
kg/P *)
t/P *)
lb/P *)
cm³/P
l/P *)
m³/P *)
gal/P *)
kgal/P *)
Cuft/P *)
bbl/P *)
Impgal/P *)
klmpgal/P *)
I(N)/P *)
m³(N)/P *)
SI/P *)
Scuft/P *)
Sm³/P *)
Pulse 1 rate
SO 1 function *)
R/W
No Function
Sel
Flow direction
Total limit switch
Mass flow alm 1
Mass flow alm 2
Mass flow alm 1+2
Vol flow alm 1
Vol flow alm 2
Vol flow alm 1+2
Density alm 1
Density alm 2
Density alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Concentr. meas alm 1
Concentr. meas alm 2
Concentr. meas alm
1+2
Net flow alm 1
Net flow alm 2
Net flow alm 1+2
Slug Alarm
Empty alarm
Corrosion Alarm
All alarms
All errors
All alarms & errors
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-27
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Basic Setup
Pulse/Status out 2
Pulse/Stat 2 select
Pulse
Sel
Status Out
No Function
Pulse 2 select
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net
R-Total net
Pulse 2 unit
Hz
Sel
g/P
kg/P
t/P
lb/P
cm³/P
l/P
m³/P
gal/P
kgal/P
Cuft/P
bbl/P
Impgal/P
klmpgal/P
I(N)/P
m³(N)/P
SI/P
Scuft/P *)
Sm³/P *)
Pulse 2 rate
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
R/W
3-28
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup
SO 2 function
No Function
Sel
Flow direction
Total limit switch
Mass flow alm 1
Mass flow alm 2
Mass flow alm 1+2
Vol flow alm 1
Vol flow alm 2
Vol flow alm 1+2
Density alm 1
Density alm 2
Density alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Concentr. meas alm 1
Concentr. meas alm 2
Concentr. meas alm
1+2
Net flow alm 1
Net flow alm 2
Net flow alm 1+2
Slug Alarm
Empty alarm
Corrosion Alarm
All alarms
All errors
All alarms & errors
SI function
No function
Sel
Autozero
Reset flex totals
Reset mass totals
Reset volume totals
Reset net totals
Reset all totals
0% signal lock
Totalizer
Total flex select
Mass
Sel
Volume
Net
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-29
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Basic Setup
Total flex unit
g
Sel
kg
t
lb
cm³
l
m³
gal
kgal
Cuft
bbl
Impgal
Klmpgal
I(N)
m³(N)
SI
Scuft
MMscuft
Sm³
Total mass unit
g
Sel
kg
t
lb
Total volume unit
cm³
Sel
l
m³
gal
kgal
Cuft
bbl
Impgal
Klmpgal
I(N) *)
m³(N) *)
SI *)
Scuft *)
MMscuft *)
Sm³ *)
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-30
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup
Total net unit
g
kg
t
lb
cm³
l
m³
gal
kgal
Cuft
bbl
Impgal
Klmpgal
Total switch select
Flex total
Sel
Mass total
Volume total
Net total
Detailed Setup Display config
Disp select 1
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-31
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup
Disp select 2
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
Disp select 3
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-32
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
Disp select 4
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
F-Total flex
R-Total flex
D-Total flex
F-Total mass
R-Total mass
D-Total mass
F-Total volume
R-Total volume
D-Total volume
F-Total net
R-Total net
D-Total net
F-Total energy
Velocity
Drive gain
None
Display contrast
-5
Sel
-4
-3
-2
-1
0
+1
+2
+3
+4
+5
Disp period
0.5s
Sel
1.0s
2.0s
Language
English
Sel
German
French
Russian
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-33
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup Sensor model
RCCS30LR *)
Sel
RCCS30 *)
RCCS31 *)
RCCS32 *)
RCCS33 *)
RCCS34
RCCS36
RCCS38
RCCS39
RCCS39/IR *)
RCCS39/XR *)
Sensor constants *)
Mass flow
Density
Config fld variables
Flow direction *)
SK20
R/W
SKT
R/W
SKTK
R/W
RV
R/W
Qnom
R
SKP
R/W
SKPT
R/W
KD
R/W
fl20
R/W
FTC1
R/W
FTCK
R/W
FPC
R/W
FPTC
R/W
FQC1
R/W
FQC2
R/W
Forward
Sel
Reverse
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-34
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
Mass flow
Mass flow unit
g/s
Sel
g/min
g/h
kg/s
kg/min
kg/h
kg/d
t/min
t/h
t/d
lb/s
lb/min
lb/h
lb/d
Mass flow format
xxxxxxx
Sel
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Mass flow LRV
R/W
Mass flow URV
R/W
Mass flow damping
R/W
Mass flow lowcut *)
R/W
Mass flow alm 1 sel
No function
Sel
More than
Less than
Mass flow alm 1 crit
Mass flow alm 2 sel
R/W
No function
Sel
More than
Less than
Mass flow alm 2 crit
Mass flow fix val sel
R/W
Inhibit
Sel
Enable *)
Mass flow fixed val *)
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-35
R/W
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup
Volume flow
Vol flow unit
cm³/s
Sel
cm³/min
cm³/h
l/s
l/min
l/h
l/d
m³/s
m³/min
m³/h
m³/d
gal/s
gal/min
gal/h
gal/d
Cuft/s
Cuft/min
Cuft/h
Cuft/d
bbl/s
bbl/min
bbl/h
bbl/d
Impgal/s
Impgal/min
Impgal/h
Impgal/d
I(N)/s *)
I(N)/min *)
I(N)/h *)
l(N)/d *)
m³(N)/s *)
m³(N)/min *)
m³(N)/h *)
m³(N)/d *)
SI/s *)
SI/min *)
SI/h *)
Sl/d *)
Scuft/s *)
Scuft/min *)
Scuft/h *)
Scuft/d *)
Sm³/s *)
Sm³/min *)
Sm³/h *)
Sm³/d *)
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-36
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
Vol flow format
xxxxxxx
Sel
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Vol flow LRV
R/W
Vol flow URV
R/W
Vol flow damping
R/W
Vol flow lowcut *)
R/W
Vol flow alm 1 sel
No function
Sel
More than
Less than
Vol flow alm 1 crit
Vol flow alm 2 sel
R/W
No function
Sel
More than
Less than
Vol flow alm 2 crit
Density
Density unit
R/W
g/ml
Sel
kg/l
kg/m³
lb/gal
lb/Cuft
g/cm³
g/l
°Bé hv *)
°Bé lt *)
°API *)
Density format
xxxxxxx
Sel
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
All Rights Reserved. Copyright © 2009, Rota Yokogawa
Density LRV
R/W
Density URV
R/W
Density damping
R/W
3-37
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup
Density lowcut *)
R/W
No function
Density alm 1 sel
Sel
More than
Less than
Density alm 1 crit
R/W
No function
Density alm 2 sel
Sel
More than
Less than
Density alm 2 crit
R/W
Ref. Density sel **)
Inhibit
Sel
Fixed
Calculated
Reference density
R/W
Reference density setup
Reference Temperature R/W
**)
Density fix val sel ***)
Temp. coeff. a
R/W
Temp. coeff. b
R/W
Inhibit
Sel
Enable *)
Density offset *)
R/W
bar
Pressure Unit
Sel
psi
MPa
Pressure
Temperature
R/W
degC
Temperature unit
Sel
degF
K
Temperature format
xxxxxxx
Sel
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Temperature LRV
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-38
R/W
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
Temperature URV
R/W
Temperature damping
R/W
Temp alm 1 sel
No function
Sel
More than
Less than
Temp alm 1 crit
Temp alm 2 sel
R/W
No function
Sel
More than
Less than
Temp alm 2 crit
Temp fix val select
R/W
Inhibit
Sel
Enable *)
Velocity unit
Temp fixed value *)
R/W
Temp gain *)
R/W
m/s
Sel
ft/s
Config Output/Input
Analog output 1
Analog 1 select *)
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
Analog 1 alarm Out
<2.4 mA
Sel
<3.6 mA
<4.0 mA
>21.0 mA
>21.6 mA
Hold
Measured value
All Rights Reserved. Copyright © 2009, Rota Yokogawa
Analog 1 low LMT
R/W
Analog 1 high LMT
R/W
3-39
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup
Analog output 2
Analog 2 select
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
Analog 2 alarm Out
<2.4 mA
Sel
<3.6 mA
<4.0 mA
>21.0 mA
>21.6 mA
Hold
Measured value
Pulse/Status out 1
Analog 2 low LMT
R/W
Analog 2 high LMT
R/W
Pulse/Stat 1 select
Pulse
Sel
Status out *)
No function *)
Pulse 1 select
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net
R-Total net
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-40
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
Pulse 1 unit
Hz
Sel
g/P
kg/P *)
t/P *)
lb/P *)
cm³/P
l/P *)
m³/P *)
gal/P *)
kgal/P *)
Cuft/P *)
bbl/P *)
lmpgal/P *)
klmpgal/P *)
I(N)/P *)
m³(N)/P *)
SI/P *)
Scuft/P *)
Sm³/P *)
Pulse 1 rate *)
Pulse 1 active mode
R/W
On Active
Sel
Off Active
Pulse 1 width
0.05ms
Sel
0.1ms *)
0.5ms *)
1ms
5ms *)
10ms *)
50ms *)
100ms *)
50ms *)
1000ms *)
Pulse 1 at alarm
0P/0Hz
Sel
Measured value
Hold
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-41
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup
No Function
SO 1 function *)
Sel
Flow direction
Mass flow alm 1
Mass flow alm 2
Mass flow alm 1+2
Vol flow alm 1
Vol flow alm 2
Vol flow alm 1+2
Density alm 1
Density alm 2
Density alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Concentr. meas alm 1
Concentr. meas alm 2
Concentr. meas alm
1+2
Net flow alm 1
Net flow alm 2
Net flow alm 1+2
Slug Alarm
Empty alarm
Corrosion Alarm
All alarms
All errors
All alarms & errors
SO1 active mode *)
On Active
Sel
Off Active
Pulse/Status out 2
Pulse/Stat 2 select
Pulse
Sel
Status out
No function
Pulse 2 select
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net
R-Total net
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-42
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
Pulse 2 unit
Hz
Sel
g/P
kg/P
t/P
lb/P
cm³/P
l/P
m³/P
gal/P
kgal/P
Cuft/P
bbl/P
lmpgal/P
klmpgal/P
I(N)/P *)
m³(N)/P *)
SI/P *)
Scuft/P *)
Sm³/P *)
Pulse 2 rate
Pulse 2 active mode
R/W
On Active
Sel
Off Active
Pulse 2 width
0.05ms
Sel
0.1ms
0.5ms
1ms
5ms
10ms
50ms
100ms
50ms
1000ms
Pulse 2 at alarm
0P/0Hz
Sel
Measured value
Hold
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-43
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup
SO2 function
No Function
Sel
Flow direction
Total limit switch
Mass flow alm 1
Mass flow alm 2
Mass flow alm 1+2
Vol flow alm 1
Vol flow alm 2
Vol flow alm 1+2
Density alm 1
Density alm 2
Density alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Concentr. meas alm 1
Concentr. meas alm 2
Concentr. meas alm
1+2
Net flow alm 1
Net flow alm 2
Net flow alm 1+2
Slug Alarm
Empty alarm
Corrosion Alarm
All alarms
All errors
All alarms & errors
SO2 active mode
On Active
Sel
Off Active
Status input
SI function
No function
Sel
Autozero
Reset flex totals
Reset mass totals
Reset volume totals
Reset net totals
Reset all totals
0% signal lock
SI active mode
On Active
Sel
Off Active
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-44
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
HART output
PV is
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
SV is
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net
R-Total net
F-Total flex
R-Total flex
D-Total mass
D-Total volume
D-Total net
D-Total flex
F-Total energy
Velocity
Drive gain
TV is
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net
R-Total net
F-Total flex
R-Total flex
D-Total mass
D-Total volume
D-Total net
D-Total flex
F-Total energy
Velocity
Drive gain
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-45
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup
QV is
Mass flow
Sel
Volume flow
Density
Temperature
Concentration meas
Net flow
None
F-Total mass
R-Total mass
F-Total volume
R-Total volume
F-Total net
R-Total net
F-Total flex
R-Total flex
D-Total mass
D-Total volume
D-Total net
D-Total flex
F-Total energy
Velocity
Drive gain
Totalizer
Total flex select
Mass
Sel
Volume
Net
Total flex unit
g
Sel
kg
t
lb
cm³
l
m³
gal
kgal
Cuft
bbl
Impgal
Klmpgal
I(N) *)
m³(N) *)
SI *)
Scuft *)
MMscuft *)
Sm³ *)
Total mass unit
g
Sel
kg
t
lb
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-46
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
Total volume unit
cm³
Sel
l
m³
gal
kgal
Cuft
bbl
Impgal
kimpgal
I(N) *)
m³(N) *)
SI *)
Scuft *)
MMscuft *)
Sm³ *)
Total net unit
g
kg
t
lb
cm³
l
m³
gal
kgal
Cuft
bbl
Impgal
kimpgal
Total unit energy
MJ
Sel
Btu
Energy factor
Heat of combustion
R/W
Heat of combustion unit MJ/kg
Sel
Btu/lb
MJ/m³(N) *)
Btu/Scuft *)
Total switch select
Flex total
Sel
Mass total
Volume total
Net total
Total limit switch
Total at alarm
R/W
Hold
Sel
Continue total
Total reset cntrl
Inhibit
Sel
Enable
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-47
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed Setup
Total reset
Not Execute
Reset flex totals
Exe
Reset mass totals
Exe
Reset volume totals
Exe
Reset net totals
Exe
Reset all totals
Exe
HART communication Poll addr
Concentration setup
Concentration meas
R/W
Num req pream
R/W
Num resp pream
R/W
Master reset
Exe
Reference Temperature
R/W
Ref. density carrier
R/W
Temp. coeff. a carrier
R/W
Temp. coeff. b carrier
R/W
Ref. density product
R/W
Temp. coeff. a product
R/W
Temp. coeff. b product
R/W
Concentr. meas unit
°Brix
Sel
Wt-% sol
Vol% sol
Vol%
Wt-%
Concentr. meas format
xxxxxxx
Sel
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
IM 01R04B07-00E-E
Concentr.meas LRV
R/W
Concentr. meas URV
R/W
Concentr. meas Damp
R/W
Concentr. meas Lowcut
R/W
3rd edition July 01, 2013-00
3-48
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup
Conc meas alm 1 Sel
No function
Sel
More than
Less than
Conc meas alm 1 Crit
Conc meas alm 2 Sel
R/W
No function
Sel
More than
Less than
Conc meas alm 2 crit
Net flow
Net flow select
R/W
Mass
Sel
Volume
Net flow unit
g/s
Sel
g/min
g/h
kg/s
kg/min
kg/h
kg/d
t/min
t/h
t/d
lb/s
lb/min
lb/h
lb/d
cm³/s
cm³/min
cm³/h
l/s
l/min
l/h
l/d
m³/s
m³/min
m³/h
m³/d
gal/s
gal/min
gal/h
gal/d
Cuft/s
Cuft/min
Cuft/h
Cuft/d
bbl/s
bbl/min
bbl/h
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-49
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
bbl/d
Detailed Setup
Impgal/s
Impgal/min
Impgal/h
Impgal/d
Net flow format
xxxxxxx
Sel
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Net flow LRV
R/W
Net flow URV
R/W
Net flow damping
R/W
Net flow lowcut
R/W
Net flow Alm 1 Sel
No function
Sel
More than
Less than
Net flow Alm 1 Crit
Net flow Alm 2 Sel
R/W
No function
Sel
More than
Less than
Net flow Alm 2 Crit
R/W
Measuring range
Slug detection
R
Slug alarm select
Not apply
Sel
Apply *)
Drive gain *)
R
Slug criteria *)
R/W
Slug duration *)
R/W
After slug *)
Measured value *)
Sel
Holdv
Drive gain damping *)
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-50
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed Setup Empty pipe detect
Empty pipe alm sel
Not apply
Sel
Apply
Empty pipe crit
After empty pipe
R/W
Massflow=Zero
Sel
Measured Value
Hold
Corrosion detect
Corrosion alm sel
Not apply
Sel
Apply
Corrosion crit
R/W
Corrosion damp
R/W
Fluid max temp
Device information
R
Distributor
R
Tag
R/W
Long Tag
R/W
Descriptor
R/W
Message
R/W
Date
R/W
Sensor model
R
Sensor S/N
R
Assembly number
R
Serial no. converter
R
Serial no. detector
R
Device S/W
Device S/W version
R
Device S/W date
R
Device id
R
Universal rev
R
Fld dev rev
R
Software rev
R
Hardware rev
R
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-51
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.4 Parameter tree, HART menu
Online
Device setup
PV
PV AO
Review
Service
Set parameters for Rotamass (see below)
Display process value in engineering unit
Display analogue output in mA
Review parameters for Rotamass (see below)
Not open
Device
setup
Language
English
German
French
Russian
Process
variables
View fld dev vars
Mass flo
Volume flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
View Outputs
Analog output 1
Analog 1 select
PV
PV AO
% rnge
R
R
R
R
Analog output 2
Analog 2 select
SV
SV AO
% rnge
R
R
R
R
Pulse/Status out 1
Pulse 1 select
TV
TV Freq
SO 1 function *)
SO 1 mode *)
No function
R
R
R
R
R
R
IM 01R04B07-00E-E
Sel
3rd edition July 01, 2013-00
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
3-52
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Pulse/Status out 2
Diag/
Service
Pulse 2 select
QV
QV Freq
SO 2 function
SO 2 mode
No function
R
R
R
R
R
R
View Input
Input function
Totalizer
Total res cntrl
Inhibit
Enable
Sel
Total reset
Not execute
Reset flex totals
Reset mass totals
Reset volume totals
Reset net totals
Reset all totals
Exe
Exe
Exe
Exe
Exe
Exe
Self test
LCD/Key Test
Self Test
Exe
Exe
Status
Event overview
Error
Alarm
Warning
R
R
R
R
Hist Overview ord
Hist Overview ord
Clear History ord
Self test/Status
Hist Overview abs
R
History Set
History Set menu
Not execute
Execute
Abs
Set 1
:
Set 10
R
R
History Set
Hist overview
H. error
H. Alarm
H. Warning
R
R
R
R
R
Clear History abs
Input/Output test
R
Exe
Analog Out 1
Analog Out 2
Pulse Out 1
Status Out 1 *)
Pulse Out 2
Status Out 2
Status Input
All Rights Reserved. Copyright © 2009, Rota Yokogawa
R
Sel
R/W
R/W
R/W
R/W
R/W
R/W
R
3-53
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Diag/
Service
Auto zero check
Autozero
Loop trim
Autozero history
Data Set
1 Newest
2
3
4
5 Oldest
Initial
R
Date
R
Val
R
Dens
R
Temp
R
AZ range
R
AZ fluctuation
R
Zero tuning
Inhibit
Enable
Autozero
Autozero duration
Sel
3min
30s
Sel
Perform auto zero
Exe
Autozero value
R
Trim output 1
Exe
Trim output 2
Exe
Tag
R/W
Long Tag
R/W
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-54
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup Display config
Disp select 1
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
Sel
Disp select 2
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
None
Sel
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-55
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Basic Setup
Display contrast
IM 01R04B07-00E-E
Disp select 3
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
None
Sel
Disp select 4
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
None
Sel
-5
-4
-3
-2
-1
0
+1
+2
+3
+4
+5
3rd edition July 01, 2013-00
Sel
3-56
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup Mass flo
Dens
Mass flo unit
g/s
g/min
g/h
kg/s
kg/min
kg/h
kg/d
t/min
t/h
t/d
lb/s
lb/min
lb/h
lb/d
Sel
Mass flo LRV
R/W
Mass flo URV
R/W
Mass flo Damping
R/W
Dens unit
g/mL
kg/L
kg/m3
lb/gal
Sel
lb/Cuft
g/cm3
g/L
°Bé hv *)
°Bé lt *)
°API *)
Temp
Analog 1 select *)
Density LRV
R/W
Density URV
R/W
Density damping
R/W
Temp unit
degC
degF
K
Sel
Temp LRV
R/W
Temp URV
R/W
Temp Damping
R/W
Mass flo
Vol flo
Density
Temperature
Conc meas
Net flo
None
Sel
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-57
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Basic Setup Analog 2 select
Pulse/Status out 1
Mass flo
Vol flo
Density
Temperature
Conc meas
Net flo
None
Sel
Pulse/Stat 1 select *) Pulse
Status out *)
No function
Sel
Pulse out 1
Pulse 1 select
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
F-Totl mass
R-Totl mass
F-Totl vol
R-Totl vol
F-Totl net *)
R-Totl net *)
Sel
TV Pls unit
Hz
g/P
kg/p *)
t/P *)
lb/P *)
cm3/P
L/P *)
m3/P *)
gal/P *)
kgal/P *)
Cuft/P *)
bbl/P *)
Impgal/P *)
klmpgal/P *)
L(N)/P *)
m3(N)/P *)
L(Std)/P *)
StdCuft/P *)
m3(Std)/P *)
Sel
TV Pls rate
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-58
R/W
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup
Pulse/Status out 2
Status out 1 *)
SO 1 function
Pulse/Stat 2 select
Pulse
Status out
No function
Pulse out 2
Pulse 2 select
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-59
No Function
Flow direction
Total Switch
Mass flo alm 1
Mass flo alm 2
Mass flo alm 1+2
Vol flo alm 1
Vol flo alm 2
Vol flo alm 1+2
Dens alm 1
Dens alm 2
Dens alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Conc alm 1
Conc alm 2
Conc alm 1+2
Net flo alm 1
Net flo alm 2
Net flo alm 1+2
Slug Alarm
Empty Alarm
Corrosion Alarm
All Alarms
All Errors
All Alarms &
Errors
Sel
Sel
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
F-Totl mass
R-Totl mass
F-Totl vol
R-Totl vol
F-Totl net
R-Totl net
IM 01R04B07-00E-E
Sel
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Basic Setup
QV Pls unit
Hz
g/P
kg/p
t/P
lb/P
cm3/P
L/P
m3/P
gal/P
kgal/P
Cuft/P
bbl/P
Impgal/P
klmpgal/P
L(N)/P *)
m3(N)/P *)
L(Std)/P *)
StdCuft/P *)
m3(Std)/P *)
QV Pls rate
Status out 2
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
SO 2 function
3-60
Sel
R/W
No Function
Flow direction
Total Switch
Mass flo alm 1
Mass flo alm 2
Mass flo alm 1+2
Vol flo alm 1
Vol flo alm 2
Vol flo alm 1+2
Dens alm 1
Dens alm 2
Dens alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Conc alm 1
Conc alm 2
Conc alm 1+2
Net flo alm 1
Net flo alm 2
Net flo alm 1+2
Slug Alarm
Empty Alarm
Corrosion Alarm
All Alarms
All Errors
All Alarms &
Errors
Sel
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Basic Setup Input function
Totalizer
No function
Autozero
Reset flex totals
Reset mass totals
Reset volume totals
Reset net totals
Reset all totals
0% Signal lock
Sel
Total flex select
Mass
Volume
Net
F-Totl flex Unit
g
kg
t
lb
cm3
L
m3
gal
kgal
Cuft
bbl
Impgal
klmpgal
L(N) *)
m3(N) *)
L(Std) *)
StdCuft *)
MMscuft *)
m3(Std) *)
F-Totl mass Unit
g
kg
t
lb
Sel
F-Totl vol Unit
cm3
L
m3
gal
kgal
Cuft
bbl
Impgal
klmpgal
L(N) *)
m3(N) *)
L(Std) *)
StdCuft *)
MMscuft *)
m3(Std) *)
Sel
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-61
Sel
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Basic Setup
Detailed
Setup
Display config
IM 01R04B07-00E-E
F-Totl net Unit
g
kg
t
lb
cm3
L
m3
gal
kgal
Cuft
bbl
Impgal
klmpgal
L(N) *)
m3(N) *)
L(Std) *)
StdCuft *)
MMscuft *)
m3(Std) *)
Sel
Total switch select
Flex total
Mass total
Volume total
Net total
Sel
Disp Select 1
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
Sel
3rd edition July 01, 2013-00
3-62
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
Disp Select 2
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
None
Sel
Disp Select 3
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
None
Sel
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-63
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed
Setup
Sensor model
IM 01R04B07-00E-E
Disp Select 4
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
F-Totl flex
R-Totl flex
D-Totl flex
F-Totl mass
R-Totl mass
D-Totl mass
F-Totl vol
R-Totl vol
D-Totl vol
F-Totl net
R-Totl net
D-Totl net
F-Totl energy
Velocity
Drive Gain
None
Sel
Display contrast
-5
-4
-3
-2
-1
0
+1
+2
+3
+4
+5
R/W
Display period
0.5s
1.0s
2.0s
Sel
Language
English
German
French
Russian
Sel
RCCS30LR *)
RCCS30 *)
RCCS31 *)
RCCS32 *)
RCCS33 *)
RCCS34
RCCS36
RCCS38
RCCS39
RCCS39/IR *)
RCCS39/XR *)
3rd edition July 01, 2013-00
Sel
3-64
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
Sensor constants *) Mass flo
SK20
R/W
SKT
R/W
SKTK
R/W
RV
R/W
Qnom
R
SKP
R/W
SKPT
R/W
KD
R/W
Fl20
R/W
FTC1
R/W
FTCK
R/W
FPC
R/W
FPTC
R/W
FQC1
R/W
FQC2
R/W
Flow direction *)
Forward
Reverse
Sel
Mass flo
Mass flo unit
g/s
g/min
g/h
kg/s
kg/min
kg/h
kg/d
t/min
t/h
td
lb/s
lb/min
lb/h
lb/d
Sel
Mass flo format
xxxxxxx
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Sel
Density
Config fld var
All Rights Reserved. Copyright © 2009, Rota Yokogawa
Mass flo LRV
R/W
Mass flo URV
R/W
3-65
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed
Setup
Mass flo damping
R/W
Mass flo lowcut *)
R/W
Mass flo alm 1 sel
No function
More than
Less than
Mass flo alm 1 crit
Mass flow alm 2 sel
R/W
No function
More than
Less than
Mass flo alm 2 crit
Vol flo
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
Sel
Sel
R/W
Mass flo fix sel
Inhibit
Enable *)
Sel
Mass flo fix menu *)
Mass flo fixed val
R/W
Vol flo Unit
cm3/s
cm3/min
cm3/h
L/s
L/min
L/h
L/d
m3/s
m3/min
m3/h
m3/d
gal/s
gal/min
gal/h
gal/d
Cuft/s
Cuft/min
Cuft/h
Cuft/d
bbl/s
bbl/min
bbl/h
bbl/d
Impgal/s
Impgal/min
Impgal/h
Impgal/d
L(N)/s *)
L(N)/min *)
L(N)/h *)
L(N)/d *)
m3(N)/s *)
m3(N)/min *)
m3(N)/h *)
m3(N)/d *)
Sel
3-66
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
L(Std)/s *)
L(Std)/min *)
L(Std)/h *)
L(Std)/d *)
StdCuft/s *)
StdCuft/min *)
StdCuft/h *)
StdCuft/d *)
m3(Std)/s *)
m3(Std)/min *)
m3(Std)/h *)
m3(Std)/d *)
Vol flo Format
xxxxxxx
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Vol flo LRV
R/W
Vol flo URV
R/W
Vol flo damping
R/W
Vol flo Lowcut *)
R/W
Vol flo alm 1 sel
No function
More than
Less than
Vol flo alm 1 crit
Vol flow alm 2 sel
All Rights Reserved. Copyright © 2009, Rota Yokogawa
Sel
R/W
No function
More than
Less than
Vol flo alm 2 crit
Dens
Sel
Sel
R/W
Dens Unit
g/mL
kg/L
kg/m3
lb/gal
lb/Cuft
g/cm3
g/L
°Bé hv
°Bé lt
°API
Sel
Dens Format
xxxxxxx
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Sel
3-67
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed
Setup
Dens LRV
R/W
Dens URV
R/W
Dens damping
R/W
Dens lowcut *)
R/W
Dens alm 1 sel
No function
More than
Less than
Dens alm 1 crit
Dens alm 2 sel
R/W
No function
More than
Less than
Dens alm 2 crit
Ref. Density sel *) **)
Inhibit
Fixed
Calculated
Sel
Fixed ref dens menu
*) **)
Reference density
R/W
Ref density setup *)
**)
Ref. temperature
R/W
Temp. coeff a
R/W
Temp. coeff b
R/W
Dens fix val sel ***)
Inhibit
Enable *)
Sel
Dens fix menu ***)
Reference density
R/W
Pressure Unit
R/W
bar
psi
MPa
Pressure
3rd edition July 01, 2013-00
Sel
R/W
Temp Unit
degC
degF
K
Sel
Temp Format
xxxxxxx
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Sel
Temp LRV
IM 01R04B07-00E-E
Sel
R/W
Density offset
Temp
Sel
3-68
R/W
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
Temp URV
R/W
Temp damping
R/W
Temp alm 1 sel
No function
More than
Less than
Temp alm 1 crit
Temp alm 2 sel
R/W
No function
More than
Less than
Temp alm 2 crit
Config Output/Input
Sel
Sel
R/W
Temp fix val sel
Inhibit
Enable
Sel
Temp fix menu
Temp fixed value
Temp gain adjust
R/W
Velocity unit
m/s
ft/s
Sel
Analog output 1
Analog 1 select *)
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
Sel
Analog 1 alarm Out
<2.4mA
<3.6mA
<4.0mA
>21.0mA
>21.6mA
Hold
Measured value
Sel
Analog 1 low LMT
Analog 1 high LMT
Analog output 2
All Rights Reserved. Copyright © 2009, Rota Yokogawa
R/W
R/W
Analog 2 select
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
Sel
SV Analog 2 alarm Out
<2.4mA
<3.6mA
<4.0mA
>21.0mA
>21.6mA
Hold
Measured value
Sel
3-69
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Analog 2 low LMT
Analog 2 high LMT
Detailed
Setup
IM 01R04B07-00E-E
Pulse/Status 1
3rd edition July 01, 2013-00
R/W
R/W
Pulse/Stat 1 sel
Pulse
Status out *)
No function *)
Pulse/freq out 1
Pulse 1 select
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
F-Totl mass
R-Totl mass
F-Totl vol
R-Totl vol
F-Totl net
R-Totl net
Sel
Freq/Pulse out 1
TV Pls unit
Hz
g/P
kg/P *)
t/P *)
lb/P *)
cm3/P
L/P *)
m3/P *)
gal/P *)
kgal/P *)
Cuft/P *)
bbl/P *)
Impgal/P *)
kImpgal/P *)
L(N)/P *)
m3(N)/P *)
L(Std)/P *)
StdCuft/P *)
m3(Std)/P *)
Sel
TV Pls rate *)
R/W
TV Pls mode
On Active
Off Active
Sel
TV Pls width
0.05ms
0.1ms *)
0.5ms *)
1ms
5ms *)
10ms *)
50ms *)
100ms *)
500ms *)
1000ms *)
Sel
3-70
Sel
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
TV Pls alarm
0 Hz / 0 Pulses
Hold
Measured value
Status out 1 *)
Pulse/Status 2
All Rights Reserved. Copyright © 2009, Rota Yokogawa
SO 1 function
No function
Sel
Flow direction
Total switch
Mass flo alm 1
Mass flo alm 2
Mass flo alm 1+2
Vol flo alm 1
Vol flo alm 2
Vol flo alm 1+2
Dens alm 1
Dens alm 2
Dens alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Conc alm 1
Conc alm 2
Conc alm 1+2
Net flo alm 1
Net flo alm 2
Net flo alm 1+2
Slug Alarm
Empty Alarm
Corrosion Alarm
All alarms
All errors
All alarms &
errors
SO 1 active mode
On Active
Off Active
Pulse/Stat 2 sel
Pulse
Status out
No function
Pulse/freq out 2
Pulse 2 select
3-71
Sel
Sel
Sel
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
F-Totl mass
R-Totl mass
F-Totl vol
R-Totl vol
F-Totl net
R-Totl net
IM 01R04B07-00E-E
Sel
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed
Setup
IM 01R04B07-00E-E
Freq/Pulse out 2
3rd edition July 01, 2013-00
3-72
QV Pls unit
Hz
g/P
kg/P
t/P
lb/P
cm3/P
L/P
m3/P
gal/P
kgal/P
Cuft/P
bbl/P
Impgal/P
kImpgal/P
L(N)/P
m3(N)/P
L(Std)/P
StdCuft/P
m3(Std)/P
Sel
QV Pls rate
R/W
QV Pls mode
On Active
Off Active
Sel
QV Pls width
0.05ms
0.1ms
0.5ms
1ms
5ms
10ms
50ms
100ms
500ms
1000ms
Sel
QV Pls alarm
0 Hz / 0 Pulses
Hold
Measured value
Sel
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
Status out 2
Status input
All Rights Reserved. Copyright © 2009, Rota Yokogawa
SO 2 function
No function
Sel
Flow direction
Total switch
Mass flo alm 1
Mass flo alm 2
Mass flo alm 1+2
Vol flo alm 1
Vol flo alm 2
Vol flo alm 1+2
Dens alm 1
Dens alm 2
Dens alm 1+2
Temp alm 1
Temp alm 2
Temp alm 1+2
Conc alm 1
Conc alm 2
Conc alm 1+2
Net flo alm 1
Net flo alm 2
Net flo alm 1+2
Slug alarm
Empty alarm
Corrosion alarm
All alarms
All errors
All alarms &
errors
SO 2 active mode
On Active
Off Active
Sel
Input function
No Function
Autozero
Reset flex totals
Reset mass totals
Reset volume
totals
Reset net totals
Reset all totals
0% signal lock
Sel
SI active mode
On Active
Off Active
Sel
3-73
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed
Setup
IM 01R04B07-00E-E
HART Output
3rd edition July 01, 2013-00
PV is
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
SV is
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
F-Totl mass
R-Totl mass
F-Totl vol
R-Totl vol
F-Totl net
R-Totl net
F-Totl flex
R-Totl flex
D-Totl mass
D-Totl vol
D-Totl net
D-Totl flex
F-Totl energy
Velocity
Drive Gain
TV is
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
F-Totl mass
R-Totl mass
F-Totl vol
R-Totl vol
F-Totl net
R-Totl net
F-Totl flex
R-Totl flex
D-Totl mass
D-Totl vol
D-Totl net
D-Totl flex
F-Totl energy
Velocity
Drive Gain
3-74
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
QV is
Totalizer
Total flex select
Mass
Volume
Net
F-Totl flex Unit
g
kg
t
lb
cm3
L
m3
gal
kgal
Cuft
bbl
Impgal
klmpgal
L(N) *)
m3(N) *)
L(Std) *)
StdCuft *)
MMscuft *)
m3(Std) *)
F-Totl mass Unit
g
kg
t
lb
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-75
Mass flo
Vol flo
Dens
Temp
Conc meas
Net flo
None
F-Totl mass
R-Totl mass
F-Totl vol
R-Totl vol
F-Totl net
R-Totl net
F-Totl flex
R-Totl flex
D-Totl mass
D-Totl vol
D-Totl net
D-Totl flex
F-Totl energy
Velocity
Drive Gain
Sel
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed
Setup
F-Totl vol Unit
cm3
L
m3
gal
kgal
Cuft
bbl
Impgal
klmpgal
L(N) *)
m3(N) *)
L(Std) *)
StdCuft *)
MMscuftv
m3(Std)v
Sel
F-Totl net Unit
g
kg
t
lb
cm3
L
m3
gal
kgal
Cuft
bbl
Impgal
klmpgal
L(Std) *)
StdCuft *)
MMscuft *)
m3(Std) *)
Sel
F-Totl energy Unit
MJ
Btu
Sel
Energy factor
Heat of combust unit
Total switch select
Sel
Heat of combustion
R/W
Flex
Mass
Volume
Net
Sel
Total limit switch
IM 01R04B07-00E-E
MJ/kg
Btu/lb
MJ/Nm3 *)
Btu/Scuft *)
R/W
Total at alarm
Hold
continue
Sel
Total res cntrl
Inhibit
Enable
Sel
3rd edition July 01, 2013-00
3-76
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
Total reset
HART
communication
Conc meas setup
Conc meas
Not execute
Reset flex total
Reset mass total
Reset volume total
Reset net total
Reset all totals
Exe
Exe
Exe
Exe
Exe
Exe
Poll addr
R/W
Num req pream
R/W
Num resp preams
R/W
Master reset
Exe
Ref. temperature
R/W
Ref. dens. carrier
R/W
Coeff. a carrier
R/W
Coeff b carrier
R/W
Ref. dens. product
R/W
Coeff. a product
R/W
Coeff. b product
R/W
Conc meas unit
degBrix
% sol-wt
% sol-vol
Wt-%
Vol-%
Sel
Conc meas Format
xxxxxxx
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Sel
Conc meas LRV
R/W
Conc meas URV
R/W
Conc meas Damp
R/W
Conc meas Lowcut
R/W
Conc meas alm 1 sel
No function
More than
Less than
Sel
Conc meas alm 1 crit
All Rights Reserved. Copyright © 2009, Rota Yokogawa
R/W
3-77
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed
Setup
Conc meas alm 2 sel
No function
More than
Less than
Conc meas alm 2 crit
Net flo
IM 01R04B07-00E-E
Net flow select
Sel
R/W
Mass
Volume
Not applicable
Sel
Net flo Unit
g/s
g/min
g/h
kg/s
kg/min
kg/h
kg/d
t/min
t/h
t/d
lb/s
lb/min
lb/h
lb/d
cm3/s
cm3/min
cm3/h
L/s
L/min
L/h
L/d
m3/s
m3/min
m3/h
m3/d
gal/s
gal/min
gal/h
gal/d
Cuft/s
Cuft/min
Cuft/h
Cuft/d
bbl/s
bbl/min
bbl/h
bbl/d
Impgal/s
Impgal/min
Impgal/h
Impgal/d
Sel
Net flo Format
xxxxxxx
xxxxx.X
xxxx.XX
xxx.XXX
xx.XXXX
x.XXXXX
Sel
3rd edition July 01, 2013-00
3-78
R
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Detailed
Setup
Net flo LRV
R/W
Net flo URV
R/W
Net flo Damp
R/W
Net flo lowcut
R/W
Net flo alm 1 sel
No function
More than
Less than
Sel
Net flo alm 1 crit
Net flo alm 2 sel
R/W
No function
More than
Less than
Sel
Net flo alm 2 crit
R/W
Measuring Range
Slug detection *)
R
Slug alarm select
Not apply
Apply
Sel
Slug detection
Drive gain
R
Slug criteria
R/W
Slug duration
R/W
After slug
Measured value
Hold
Sel
Drive gain damping
Empty pipe detect
Empty pipe alm sel
Not apply
Apply
Sel
Empty pipe detect
Empty pipe crit
R/W
After empty pipe
Corrosion detect
Massflow =Zero
Measured Value
Hold
Sel
Corrosion alm sel
Not apply
Apply
Sel
Corrosion detect
Corrosion crit
R/W
Corrosion damp
R/W
Fluid max temp
All Rights Reserved. Copyright © 2009, Rota Yokogawa
R
3-79
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Detailed
Setup
Review
Device info
Device information
Tag
R/W
Long Tag
R/W
Descriptor
R/W
Message
R/W
Date
R/W
Sensor model
R
Sensor S/N
R
Final asmbly num
R
S/N Converter
R
S/N Detector
R
Revision #‘s
Universal rev
Fld dev rev
Software rev
Hardware rev
R
R
R
R
Device S/W
Device S/W version
Device S/W date
R
R
Distributor
Sensor model
Sensor S/N
Final asmbly num
R
R
R
R
Tag
Long Tag
Describtor
Message
Date
R
R
R
R
R
Dev id
Universal rev
Fld dev rev
Software rev
Hardware rev
R
R
R
R
R
Device S/W version
Device S/W date
S/N Converter
S/N Detector
R
R
R
R
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-80
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Review
Sensor
SK20 *)
SKT *)
SKTKv
RV *)
Qnom *)
SKP *)
SKPT *)
R
R
R
R
R
R
R
KD *)
fl20 *)
FTC1 *)
FTCK *)
FPC *)
FPTC *)
FQC1 *)
FQC2 *)
R
R
R
R
R
R
R
R
Autozero value
R
Rev Fld Dev Flow direction *)
vars 1
Mass flo unit
Mass flo LRV
Mass flo URV
Mass flo damp
Mass flo lowcut *)
Mass flo alm 1 sel
Mass flo alm 1 crit
Mass flo alm 2 sel
Mass flo alm 2 crit
Mass flo fixed value
*)
R
R
R
R
R
R
R
R
R
R
R
Vol flo unit
Vol flo LRV
Vol flo URV
Vol flo damp
Vol flo lowcut *)
Vol flo alm 1 sel
Vol flo alm 1 crit
Vol flo alm 2 sel
Vol flo alm 2 crit
R
R
R
R
R
R
R
R
R
Dens unit
Dens LRV
Dens URV
Dens damp
Dens lowcut *)
Dens alm 1 sel
Dens alm 1 crit
Dens alm 2 sel
Dens alm 2 crit
Reference density
*)
Density offset
Pressure
Pressure unit
R
R
R
R
R
R
R
R
R
All Rights Reserved. Copyright © 2009, Rota Yokogawa
R
R
R
R
3-81
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Rev Fld Dev Temperature unit
vars 1
Temp LRV
Temp URV
Temp damp
Temp range select
Temp alm 1 select
Temp alm 1 crit
Temp alm 2 select
Temp alm 2 crit
Temp fixed value *)
R
R
R
R
R
R
R
R
R
R
Velocity unit
R
Rev Fld Dev Conc meas Unit
vars 2
Conc meas LRV
Conc meas URV
Conc meas damp
Conc meas lowcut
Conc alm 1 select
Conc alm 1 crit
Conc alm 2 sel
Conc alm 2 crit
R
R
R
R
R
R
R
R
R
Net flo select
Net flo unit
Net flo LRV
Net flo URV
Net flo damping
Net flo lowcut
Net flo alm 1 sel
Net flo alm 1 crit
Net flo alm 2 sel
Net flo alm 2 crit
R
R
R
R
R
R
R
R
R
R
Rev Outputs Analog 1 select *)
/Input
PV Alarm 1 select
PV Analog 1 low LMT
PV Analog 1 high LMT
R
R
R
R
Analog 2 select
SV Alarm 2 select
SV Analog 2 low LMT
SV Analog 2 high LMT
R
R
R
R
Pulse/Stat 1 sel
Pulse 1 select *)
Pls Unit
Pls Rate *)
Pls Mode
Pls Width *)
Pls Alarm
SO 1 function *)
SO 1 active mode
*)
R
R
R
R
R
R
R
R
Pulse/Stat 2 select
Pulse 2 select
Pls Unit
R
R
R
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
R
3-82
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Rev HART
Pls Rate
Pls Mode
Pls Width
Pls Alarm
SO 2 function
SO 2 active mode
R
R
R
R
R
R
Input function
SI active mode
R
R
PV is
SV is
TV is
QV is
R
R
R
R
Total flex select
F-Totl flex Unit
F-Totl mass Unit
F-Totl vol Unit
F-Totl net Unit
R
R
R
R
R
F-Totl energy Unit
Heat of combust unit
Heat of combustion
R
R
R
Total switch sel
Total limit switch
Total at alarm
Total res cntrl
R
R
R
R
Poll addr
Num req pream
Num resp pream
R
R
R
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-83
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.5 Mass flow functions (Basic or Detailed Setup)
Mass flow
To set the functions of mass flow measurement.
Mass flow unit
Select: g/s, g/min, g/h, kg/s, kg/min, kg/h, kg/d, t/min, t/h, t/d, lb/s,
lb/min, lb/h, lb/d
Mass flow format
Select: xxxxxxx,xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX
Mass flow LRV
(low range value)
Set a mass flow value to the 4 mA or 0 Hz. LRV can also be negative to
measure reverse flow.
Mass flow URV
(upper range value)
Set a mass flow value to the 20 mA or xxxxxHz.
Abs(URV-LRV) ≥ 5% of Qnom for liquids and 1% for gases
Mass flow damping
Set the damping time in s. Damping time affects outputs and display.
After 5 times damping time the given value is displayed (t=63%).
Mass flow lowcut
Set the low cut. Low cut affects outputs and display and applies to
negative and positive flow. A hysteresis of 0.05% of Qnom is given by
the system.
Mass flow alm 1 sel
Select: No function, More than, Less than
Mass flow alm 1 crit
Select a mass flow alarm level. What happens in case of an alarm has
to be defined in Status out (3.12, 3.13).
Mass flow alm 2 sel
Select: No function, More than, Less than
Mass flow alm 2 sel
Restrictions:
All alarms have to be in 0-110%
of URV-LRV.
Alarm criteria 2 must always be
larger than alarm criteria 1.
Select a mass flow alarm level. What happens in case of an alarm has
to be defined in Status out (3.12, 3.13).
Mass flow fix val sel
Select: Inhibit, Enable
Mass flow fixed value
Select a fix Mass flow value (only for test purpose or in case of
maintenance).
The set value is added to the actual value. In case of no flow it will vary
with the zero fluctuation.
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-84
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
3.6 Volume flow functions (Basic or Detailed Setup)
Volume flow
To set the functions of volume flow measurement. Notice: Volume flow
is derived density and mass flow measurement.
Errors in density measurement (e.g. from gas bubbles) effects the
accuracy of volume flow. For liquid it is recommended to use mass flow
as original measurement. Density below roh = 0.3 kg/l volume flow is
set to zero (for liquids)
Vol flow unit
Select:
cm³/s, cm³/min, cm³/h, l/s, l/min, l/h, l/d, m³/s, m³/min, m³/h, m³/d,
gal/s, gal/min, gal/h, gal/d, Cuft/s, Cuft/min, Cuft/h, Cuft/d, bbl/s,
bbl/min, bbl/h, bbl/d, Impgal/s, Impgal/min, Impgal/h, Impgal/d,
I(N)/s, I(N)/min, I(N)/h, l(N)/d, m³(N)/s, m³(N)/min, m³(N)/h, m³(N)/d,
SI/s, SI/min, SI/h, Sl/d, Scuft/s, Scuft/min, Scuft/h, Scuft/d, Sm³/s,
Sm³/min, Sm³/h, Sm³/d
I(N)/s, I(N)/min, I(N)/h, l(N)/d, m³(N)/s, m³(N)/min, m³(N)/h, m³(N)/d
only for gas application.
SI/s, SI/min, SI/h, Sl/d, Scuft/s, Scuft/min, Scuft/h, Scuft/d, Sm³/s,
Sm³/min, Sm³/h, Sm³/d only for gas application or if Reference density
value is selected.
Vol flow format
Select; xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX
Vol flow LRV
(low range value)
Set a volume flow value to the 4 mA or 0 Hz. LRV can also be negative
to measure reverse flow.
Vol flow URV
(upper range value)
Set a volume flow value to the 20 mA or xxxxx Hz.
Abs(URV-LRV) ≥ 5% of Qvnom for liquids.
For gas application Abs(URV-LRV) ≥ 1%
Vol flow damping
Set the damping time in s. Damping time affects outputs and display.
After 5 times damping time the given value is displayed (t=63%)
Vol flow lowcut
Set the low cut. Low cut affects outputs and display. Any low cut on
mass flow will affect volume flow also. A hysteresis of 0.05% of Qnom
on mass flow is given by the system.
Vol flow alm 1 sel
Select: No function, More than, Less than
Vol flow alm 1 crit
Select a volume flow alarm level. What happens in case of an alarm has
to be defined in Status (3.12, 3.13).
Vol flow alm 2 sel
Select: No function, More than, Less than
Vol flow alm 2 crit
Restrictions:
All alarms have to be in 0-110%
of URV-LRV.
Alarm criteria 2 must always be
larger than alarm criteria 1.
Select a volume flow alarm level. What happens in case of an alarm has
to be defined in Status out (3.12, 3.13).
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-85
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.7 Density functions (Basic or Detailed Setup)
Density
To set the functions of density measurement.
Notice: Density measurement is only reliable if there is no gas in the
liquid. For liquid measurement a density lower 0.3 kg/l is displayed as
0.0 kg/l. For gas measurement set a fixed density value.
Density unit
Select:
g/ml, kg/l, kg/m³, lb/gal, lb/Cuft, g/cm³, g/l, °Bé hv, °Bé lt, °API
°Bé hv, °Bé lt, °API only with option /CST
Density format
Select: xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX
Density LRV
(low range value)
Set a density value to the 4 mA or 0 Hz.
Density URV
(upper range value)
Set a density value to the 20 mA or xxxxx Hz.
Abs(URV-LRV) ≥ 0.05 kg/l
Density damping
Set the damping time in s. Damping time affects outputs and display.
After 5 times damping time the given value is displayed (t=63%)
Density lowcut
Set the low cut. Low cut affects outputs and display.
Density alm 1 sel
Select: No function, More than, Less than
Density alm 1 crit
Select a density alarm level. What happens in case of an alarm has to
be defined in Status out (3.12, 3.13).
Density alm 2 sel
Select: No function, More than, Less than
Density alm 2 crit
Restrictions:
All alarms have to be in 0-110%
of URV-LRV
Alarm criteria 2 must always be
larger than alarm criteria 1.
Select a density alarm level. What happens in case of an alarm has to
be defined in Status out (3.12, 3.13).
Density Fix val sel
(only software revision lower
than 1.8.20)
Select: Inhibt, Enable
Ref. Density sel
(from software revision 1.8.20)
Select: Inhibit, Fixed, Calculated
If Fixed or Calculated is selected, reference density and corrected volume flow is output. Otherwise measured density and volume flow is
output.
Calculated reference density is not available if concentration measurement (option /Cxx) or gas measurement (option /GA) is activated.
Reference density
IM 01R04B07-00E-E
Set a fixed reference density value. For gas measurement (option /
GA) set here your actual density for output of volume flow. For output of
standard or normal volume flow set the standard or normal density of
your gas
accordingly. For liquid measurement this parameter can also be used to
enter the standard density of your liquid for output of standard volume
flow or for the actual density in case of density disturbances.
3rd edition July 01, 2013-00
3-86
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Reference density setup
(from software revision 1.8.20)
To setup the coefficients used for calculating the reference density.
ρref = ρ (1 + a Δt + b Δt²) ; Δt = t - tref
ρref : density at reference temperature
ρ : measured density
t : measured temperature
tref : reference temperature
a : linear thermal expansion coefficient
b : quadratic thermal expansion coefficient
Reference temperature
(from software revision 1.8.20)
Set the reference temperature for the reference density calculation.
Temp. coeff. a
(from software revision 1.8.20)
Set the linear thermal expansion coefficient of the liquid for the reference density calculation.
Temp. coeff. b
(from software revision 1.8.20)
Set the quadratic thermal expansion coefficient of the liquid for the reference density calculation.
Density offset
If the Rotamass detector is installed horizontally (bend down) the value
from the following table must be entered according to the concerning
sensor model.
RCCS30LR
5.25 g/l
RCCS30
2.70 g/l
RCCS31
1.80 g/l
RCCS32
2.00 g/l
RCCS33
0.60 g/l
RCCx34
0.90 g/l
RCCx36
0.35 g/l
RCCx38 to 39/XR
0 g/l (default)
ROTAMASS is density-calibrated vertically. If the ROTAMASS detector is
installed horizontal an density
offset value from the above table has to be entered to the parameter reference density. As positive values if the tubes are down and as negative
value if the tubes are up.
Pressure
Set the average static line pressure.
Static pressure effect on density and mass flow will be corrected automatically.
Pressure unit
Select: bar, psi, MPa
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-87
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.8 Temperature functions (Basic or Detailed Setup)
Temperature
To set the functions of temperature measurement.
Notice: Standard range:
-200 to 230°C
High temp. range (/HT): 0 to 400°C
Temperature Unit
Select: degC, degF, K
Temperature format
Select: xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX
Temperature LRV
(low range value)
Set a temperature value to the 4 mA or 0 Hz
Temperature URV
(upper range value)
Set a temperature value to the 20 mA or xxxxx Hz.
Abs(URV-LRV) ≥ 10K
Temperature damping
Set the damping time in s. Damping time affects outputs and display.
After 5 times damping time the given value is displayed (t=63%).
Temperature alm 1 sel
Select: No function, More than, Less than
Temperature alm 1 crit
Select a temperature alarm level.
What happens in case of an alarm has to be defined in Status out (3.12,
3.13).
Temperature alm 2 sel
Select: No function, More than, Less than
Temperature alm 2 crit
Select a temperature alarm level.
Restrictions:
What happens in case of an alarm has to be defined in Status out (3.12,
All alarms have to be in 0-110% 3.13).
of URV-LRV Alarm criteria 2
must always be larger than alarm
criteria 1.
Temperature fix val select
Select: Inhibit, Enable
Temperature fixed value
Select a temperature value in case of malfunction of the built in
temperature sensor.
Temperature gain
Change the gain by setting a factor different from 1.
The ROTAMASS temperature sensor is installed outside of the measuring
tubes. So at high or low fluid temperature the temperature measurement
may show a deviation as a function of the quality of heat insulation. This
function allows correcting temperature measurement for better accuracy
in mass flow and density.
Note: It is not recommended to use this function unless correct
measurement over the complete process temperature range can be
confirmed. It is not sufficient to proof correct measurement at one
temperature or in a very narrow temperature range unless the process
operates exclusively within this range.
3.9 Velocity functions (Detailed Setup)
Velocity
To set the function of the medium velocity.
Not available for gas measurement (/GA)
Velocity is not calculated if reference density is enabled.
Velocity unit
Select: m/s, ft/s
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-88
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
3.10 Analog 1 functions (Basic or Detailed Setup)
Analog output 1
To set the current output 1. This output provides HART communication.
Analog 1 select
Select: Mass flow (0), Volume flow (1), Density (2), Temperature (3),
Concentration meas (4), Net flow (5), None (6)
Numbers may be displayed if selected via HART.
If None is selected, output is 4 mA, HART communication is available.
Analog 1 alarm out
(Detailed setup, configure
output/input)
Select: <2.4 mA, <3.6 mA, <4 mA, >21 mA, >21.6 mA
Analog 1 low LMT
Default: 3.8mA
(low limit)
Setting range: 3.8 - 20.5 mA
(Detailed setup, configure
output/ input)
The alarm is active if the
measured value is lower than the
low limit.
Analog 1 high LMT
Default: 20.5mA
(high limit)
Setting range: 3.8 - 20.5 mA
(Detailed setup, Configure output/
input)
The alarm is active if the
measured value is higher than
the high limit.
Example for Bi-directional flow (NAMUR):
110
21.6
100
20 High-LMT 20.5 mA
18.4
90
16.8
LRV < 0 (e.g. -100% of flow)
70
15.2
60
13.6
50
12
40
10.4
30
8.8
20
7.2
5.6
10
possible Low cut
0
-110
-10
-90
-70
-50
-30
-10 0 10
30
Reverse ← Flow [%] → Forward
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-89
50
Output current [mA]
Output current [%]
80
70
90
4 Low-LMT 3.8 mA
1102.4
T76a.EPS
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.11 Pulse/Status output 1 functions (Basic or Detailed
Setup)
Pulse/Status out 1
To set the pulse/status output 1.
Pulse/Stat 1 select
Select: Pulse out, Status out, No function
If Pulse is selected, Status out 1 (SO) is not available.
If Status out is selected, pulse parameters are not available.
Pulse 1 select
Select: Mass flow (0), Volume flow (1), Density (2), Temperature (3),
Concentration meas (4), Net flow (5), None (6), F-Total mass (7),
R-Total mass (8), F-Total volume (9), R-Total volume (10),
F-Total net (11), R-Total net (12)
Numbers may be displayed if selected via HART.
If F-Total mass, F-Total volume or F-Total net are selected, pulse
output only works at forward flow.
If R-Total mass, R-Total volume or R-Total net are selected, pulse
output only works at reverse flow.
Pulse 1 unit
Select: Hz, g/P, kg/P, t/P, lb/P, cm³/P, l/P, m³/P, gal/P, kgal/P, Cuft/P,
bbl/P, Impgal/P, kImpgal/P, I(N)/P, m³(N)/P, SI/P, Scuft/P, Sm³/P
NOTE
To select the pulse output mass
or volume has to be selected.
If mass flow or volume flow is
selected the output delivers only
frequency.
If Pulse 1 select is Mass flow, Volume flow, Density, Temperature
or Concentration meas, only Hz can be selected.
If Pulse 1 select is F-Total mass, R-Total mass, F-Total volume,
R-Total volume, F-Total net or R-Total net only unit/P can be selected.
I(N)/P, m³(N)/P only for gas application.
SI/P, Scuft/P, Sm³/P only for gas application or if reference density
value is selected.
Pulse 1 rate
The Pulse rate can be set according to the unit set in Pulse 1 unit.
Pulse rate is 0 to 10000 Hz. Minimum output 20 Hz.
Pulse 1 active mode
Select: On Active, Off Active
The output levels depending on this parameter are shown on page 7-91.
Pulse 1 width
Select: 0.05ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms,
500ms, 1000ms
Pulse 1 at alarm
Select: 0P/0Hz, Measured value, Hold
If 0P/0Hz is selected, in case of alarm the pulse output is stopped.
If Measured value is selected, the pulse output keeps on measuring.
If Hold is selected, the pulse output keeps the value before entering the
alarm/error state.
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-90
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
SO 1 function
Select: No Function, Flow direction, Total limit switch, Mass flow
alm 1, Mass flow alm 2, Mass flow alm 1+2, Vol flow alm 1, Vol flow
alm 2, Vol flow alm 1+2, Density alm 1,Density alm 2, Density alm
1+2, Temp alm 1, Temp alm 2, Temp alm 1+2, Concentration meas
alm 1, Concentration meas alm 2, Concentration meas alm 1+2,
Net flow alm 1, Net flow alm 2, Net flow alm 1+2, Slug alarm, Empty
alarm, Corrosion alarm, All alarms, All errors, All alarms & errors
If Flow direction is selected, status output becomes active for forward
flow and not active for reverse flow, if parameter flow direction set to
forward. It is the other way round, if parameter flow direction is set to
reverse (see 3.17).
If Total limit switch is selected, status output becomes active, when the
totalizer reaches the value set to parameter Total limit switch (see 3.17).
If an alarm function is selected, status output becomes active, if the
concerning alarm occurs.
If All alarms is selected, status output becomes active, if at least one
alarm occurs. The same applies for errors with the setting All errors.
For All alarms & errors the status output becomes active, if at least
one alarm or one error occurs.
SO1 active mode
Select: On Active, Off Active
The output levels depending on this parameter are shown on page 7-94.
If Pulse is selected, under Basis Setup the
Pulse unit and
Pulse rate
have to be defined.
Under ´Detailed Setup´
Pulse unit
Pulse rate
Pulse active mode and
Pulse width
have to be defined.
If the pulse output is set under Basic Setup, the
pulse width is the width set under Detailed Setup
If the pulse width is not configured under Detailed
Setup menu the pulse width will be set default to
1ms.
If ´frequency´ is selected the frequency generated
at URV (upper range value) has to be defined.
Default is URV = 1000Hz.
Differences between Pulse and Frequency
output
For pulse output the mass (or volume) is internally
totalized and if the increment is reached, one
pulse is sent.
For a frequency output the measured value is
calculated in actual frequency according to the
definition of the user (e.g. 10000 Hz = 54321 kg/h)
with 50% duty cycle.
Set as frequency output the pulse length is changing
with the change of the measured value.
How to set status, pulse or frequency
output (using the display keys, equivalent via HART)
Status
Basic Setup or Detailed Setup
Pulse/Status out 1
Pulse/Stat 1 select
Select : Status out
Pulse or Frequency
Basic Setup or Detailed Setup
Pulse/Status out 1
Pulse/Stat 1 select
Select : Pulse
Pulse 1 select
F-Total mass
→
Pulse
R-Total mass
→
Pulse
F-Total volume
→
Pulse
R-Total volume
→
Pulse
F-Total net
→
Pulse
R-Total net
→
Pulse
Mass Flow
→
Frequency
Volume Flow
→
Frequency
Net Flow
→
Frequency
Density
→
Frequency
Temperature
→
Frequency
Concentration meas.→
Frequency
Notice : By selecting a variable (mass or volume)
which can be totalized automatically the pulse
output is selected.
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-91
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
If the flow is higher than max.Q pulses will be
lost. Therefore it is mandatory to choose the
pulse width/rate so, that the calculated max.Q
is always 10% higher than the maximum expected flowrate.
NOTE
At frequencies above 500 Hz, frequency output 1
inserts gaps in the pulse train. Therefore it is
required to use a minimum pulse integration time
of 10 sec. to get accurate frequency measurements.
If shorter pulse integration time is necessary e.g.
for batching applications, it is recommended to
use frequency output 1 up to max. 500 Hz.
10% higher is recommended because the duty
cycle is not always exact 50%. For certain pulse
widths the duty cycle at max.Q is larger than 50%
so fewer pulses can be generated. These pulses
are delivered later when the flowrate is again
below max.Q minus 10%. To avoid this situation it
is recommended to keep the flowrate always 10%
below max.Q.
Example :
Flowrate : 11 t/h
Pulse unit : kg
Pulse rate : 0.1 kg/P
Time factor (related to s) = 3600 P/h
Check :
Lowest pulse width
= 0.5 s*pulse rate* time factor/ max. flow rate
= 0.5 s*0.1 kg/P *3600 P/h /(11000 kg/h)
= 16.4 ms
→ customer should select 10 ms pulse width or lower.
Max. Q = 18000 kg/h
11000 kg/h < 18000 kg/h - 10%
Result :
Pulse width = 10 ms
Pulse rate = 0.1 kg/P
For a first orientation the max. Q for certain pulse
widths and units for a pulse rate of 0.1, 1 and 10
are given in the table 7-1.
Set as a pulse output the pulse length is constant
but the time between the pulses varies. Even at
constant flow the time between the pulses might
vary because the microprocessor has to find a
suitable gap in its timing to send the pulse.
Typical pattern for frequency output :
Typical pattern for pulse output
(50 ms; 0.1 kg/P; 2580 kg/h) :
Max. flow restriction :
flow
Setting the pulse output
Because the duty cycle of pulses is max. 50%,
the max. flowrate is restricted by the pulse width,
the unit and the pulse rate :
Max. flow rate =
1s/(pulse width*2) *pulse rate *time factor
Example :
Max. Q should be calculated in kg/min
Pulse width = 50 ms
Pulse rate = 0.1 kg/P
Time factor (related to s) = 60 P/min
Max. Q = 1s/(0.05s *2) *0.1kg/P * 60P/min = 60kg/min
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
this amount will
be lost
Max flow from pulse width, unit, rate
Grey zone
t
3-92
F3.EPS
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
Table 7-1: Max. flowrate for different pulse settings reduced by 10%:
Pulse
Unit
g
g
g
kg
kg
kg
t
t
t
Pulse
rate
0.1
1
10
0.1
1
10
0.1
1
10
1000
500
0.45
0.9
Pulse Width in ms
100
50
10
5
1
0.5
0.1 **
Max. pulse sending frequency for the different pulse settings in P/s
4.5
9
45
90
450
900
4500
0.05 **
9000
Maximum Flow Rate *
162 g/h
1.62 kg/h
16.2 kg/h
162 kg/h
1.62 t/h
16.2 t/h
162 t/h
1620 t/h
16200 t/h
324 g/h
3.24 kg/h
32.4 kg/h
324 kg/h
3.24 t/h
32.4 t/h
324 t/h
3240 t/h
---
1.62 kg/h
16.2 kg/h
162 kg/h
1.62 t/h
16.2 t/h
162 t/h
1620 t/h
16200 t/h
---
3.24 kg/h
32.4 kg/h
324 kg/h
3.24 t/h
32.4 t/h
324 t/h
3240 t/h
-----
16.2 kg/h 32.4 kg/h 162 kg/h 324 kg/h 1.62 t/h 3.24 t/h
162 kg/h 324 kg/h 1.62 t/h 3.24 t/h 16.2 t/h 32.4 t/h
1.62 t/h 3.24 t/h 16.2 t/h 32.4 t/h
162 t/h
324 t/h
16.2 t/h 32.4 t/h
162 t/h
324 t/h 1620 t/h 3240 t/h
162 t/h
324 t/h 1620 t/h 3240 t/h 16200 t/h
--1620 t/h 3240 t/h 16200 t/h
------16200 t/h
-----------------------------------
*) Maximum Flow rate is also limited by sensor size
** Note for pulse output 2: Pulse width 0.1 ms & 0.05 ms are only implemented for convenience. Due to the limited bandwidth proper function can not be guaranteed.
The following tables show the physical output levels of the pulse / status outputs depending on the setting
of parameter Pulse 1/2 active mode or SO 1/2 active mode.
Output
Situation
On active
Output transistor
Pulse/Status out 1
No Alarm/No Pulse
Alarm/Pulse
open (OFF)
closed (ON)
Level Pout+
Passive
High (Us)*
Low (≤ 1 V)
Pulse/Status out 2
No Alarm/No Pulse
Alarm/Pulse
open (OFF)
closed (ON)
Level Sout+
High (Us)*
Low (≤ 1 V)
Output
Situation
Off active
Output transistor
Pulse/Status out 1
No Alarm/No Pulse
Alarm/Pulse
closed (ON)
open (OFF)
Level Pout+
Passive
Low (≤ 1 V)
High (Us)*
Pulse/Status out 2
No Alarm/No Pulse
Alarm/Pulse
closed (ON)
open (OFF)
Level Sout+
Low (≤ 1 V)
High (Us)*
Level Pout+
Active (/AP)
High (15 VDC)
Low (≤ 1 V)
Level Pout+
Active (/AP)
Low (≤ 1 V)
High (15 VDC)
*) Us is the external power supply voltage of the pulse / status output
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-93
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.12 Pulse/Status output 2 functions (Basic or Detailed
Setup)
Pulse/Status out 2
To set the pulse/status output 2.
Pulse/Stat 2 select
Select: Pulse out, Status out, No function
If Pulse is selected, Status out 2 (SO) is not available.
If Status out is selected, pulse parameters are not available.
Pulse 2 select
Select: Mass flow (0), Volume flow (1), Density (2), Temperature (3),
Concentration meas (4), Net flow (5), None (6), F-Total mass (7),
R-Total mass (8), F-Total volume (9), R-Total volume (10),
F-Total net (11), R-Total net (12)
Numbers may be displayed if selected via HART.
If F-Total mass, F-Total volume or F-Total net are selected, pulse
output only works at forward flow.
If R-Total mass, R-Total volume or R-Total net are selected, pulse
output only works at reverse flow.
Pulse 2 unit
Select: Hz, g/P, kg/P, t/P, lb/P, cm³/P, l/P, m³/P, gal/P, kgal/P, Cuft/P,
bbl/P, Impgal/P, kImpgal/P, I(N)/P, m³(N)/P, SI/P, Scuft/P, Sm³/P
NOTE
If Pulse 2 select is Mass flow, Volume flow, Density, Temperature
or Concentration meas, only Hz can be selected.
To select the pulse output mass
or volume has to be selected.
If mass flow or volume flow is
selected the output delivers only
frequency.
If Pulse 2 select is F-Total mass, R-Total mass, F-Total volume,
R-Total volume, F-Total net or R-Total net only unit/P can be selected.
I(N)/P, m³(N)/P only for gas application.
SI/P, Scuft/P, Sm³/P only for gas application or if Reference density
value is selected.
Pulse 2 rate
The Pulse rate can be set according to the unit set in Pulse 2 unit.
Pulse rate is 0 to 2000 Hz. Minimum output 20 Hz.
Pulse 2 active mode
Select: On Active, Off Active
The output levels depending on this parameter are shown on page 7-91.
Pulse 2 width
Select: 0.05ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms,
500ms, 1000ms
Pulse 2 at alarm
Select: 0P/0Hz, Measured value, Hold
If 0P/0Hz is selected, in case of alarm the pulse output is stopped.
If Measured value is selected, the pulse output keeps on measuring.
If Hold is selected, the pulse output keeps the value before entering the
alarm/error state.
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-94
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
SO 2 function
Select: No Function, Flow direction, Total limit switch, Mass flow
alm 1, Mass flow alm 2, Mass flow alm 1+2, Vol flow alm 1, Vol flow
alm 2, Vol flow alm 1+2, Density alm 1,Density alm 2, Density alm
1+2, Temp alm 1, Temp alm 2, Temp alm 1+2, Concentration meas
alm 1, Concentration meas alm 2, Concentration meas alm 1+2,
Net flow alm 1, Net flow alm 2, Net flow alm 1+2, Slug alarm, Empty
alarm, Corrosion alarm, All alarms, All errors, All alarms & errors
If Flow direction is selected, status output becomes active for forward
flow and not active for reverse flow, if parameter flow direction set to
forward. It is the other way round, if parameter flow direction is set to
reverse (see 3.17).
If Total limit switch is selected, status output becomes active, when the
totalizer reaches the value set to parameter Total limit switch (see 3.17).
If an alarm function is selected, status output becomes active, if the
concerning alarm occurs.
If All alarms is selected, status output becomes active, if at least one
alarm occurs. The same applies for errors with the setting All errors.
For All alarms & errors the status output becomes active, if at least
one alarm or one error occurs.
SO2 active mode
Select: On Active, Off Active
The output levels depending on this parameter are shown on page 7-94.
Detailed information about using the pulse and status output see chapter 3.12.
3.13 Status input functions (Basic or Detailed Setup)
Status input
To set the status input.
SI function
Select: No function, Autozero, Reset flex totals, Reset mass totals,
Reset volume totals, Reset net totals, Reset all totals, 0% signal
lock
If Autozero is selected, active status input starts autozero procedure.
If 0% signal lock is selected, analog outputs 1 and 2 are fixed to 4 mA
while status input is active.
If parameter Total reset cntrl is enabled:
-If Reset flex totals is selected, active status input sets flex
totalizer to zero.
-If Reset mass totals is selected, active status input sets mass
totalizer to zero.
-If Reset volume totals is selected, active status input sets
volume totalizer to zero.
-If Reset net totals is selected, active status input sets
net totalizer to zero.
-If Reset all totals is selected, active status input sets all
totalizer to zero.
SI active mode
Select: On Active, Off Active
If On Active is selected, the status input is closed active.
If Off Active is selected, the status input is open active.
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-95
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.14 HART output (Detailed Setup)
HART output
To set the assignments of HART device variables which are reported via
HART Universal Command 3.
PV is
Set the assignment of Primary variable (PV).
PV is linked to Analog output 1. Changing of PV will change the
assignment of Analog output 1 and vice versa.
Select: Mass flow, Volume flow, Density, Temperature,
Concentration meas, Net flow, None
SV is
Set the assignment of Secondary variable (SV).
SV is linked to Analog output 2. Changing of SV will change the
assignment of Analog output 2 and vice versa.
Select: Mass flow, Volume flow, Density, Temperature,
Concentration meas, Net flow, None
If Analog output 2 is not available (option /KF2) an extended selection is
available, see “HART Variable list” below.
TV is
Set the assignment of Tertiary variable (TV).
TV is linked to Pulse output 1 if Pulse/Stat 1 sel is set to Pulse. In this
case changing of TV will change the assignment of Pulse output 1 and
vice versa.
Select: Mass flow, Volume flow, Density, Temperature,
Concentration meas, Net flow, None, F-Total mass, R-Total mass,
F-Total volume, R-Total volume, F-Total net, R-Total net
If Pulse/Stat 1 sel is set to Status out or No function an extended
selection is available, see “HART Variable list” below . This selection is
stored separately from the selection for “Pulse”.
QV is
Set the assignment of Quaternary variable (QV).
QV is linked to Pulse output 2 if Pulse/Stat 2 sel is set to Pulse. In this
case changing of QV will change the assignment of Pulse output 2 and
vice versa.
Select: Mass flow, Volume flow, Density, Temperature,
Concentration meas, Net flow, None, F-Total mass, R-Total mass,
F-Total volume, R-Total volume, F-Total net, R-Total net
If Pulse output 2 is not available (option /KF2 ) or Pulse/Stat 2 sel is set to
Status out or No function an extended selection is available, see “HART
Variable list” below.
This selection is stored separately from the selection for “Pulse”.
HART Variable list
(For HART- communication:
Variables which are not
allowed will be rejected by
"Invalid Selection")
IM 01R04B07-00E-E
Mass flow, Volume flow, Density, Temperature,
Concentration meas, Net flow, None,
F-Total mass, R-Total mass,
F-Total volume, R-Total volume,
F-Total net, R-Total net,
F-Total flex, R-Total flex,
D-Total mass, D-Total volume,
D-Total net, D-Total flex,
F-Total energy, Velocity, Drive Gain
3rd edition July 01, 2013-00
3-96
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
3.15 Totalizer functions (Basic or Detailed Setup)
Totalizer
Total flex select
Total flex unit
Total mass unit
Total volume unit
Total net unit
To set totalizer function.
Totalizer increments the forward flow if flow direction is forward or
the reverse flow if flow direction is reverse.
Flex totalizer is available as a secondary total for mass, volume or net.
Select: Mass, Volume, Net
If assignment is changed Flex totalizer will be set to zero, Total flex
unit will be set to default.
When Total flex select is set to Mass or Net,
the Total flex unit g, kg, t, lb can be selected.
When Total flex select is set to Volume or Net,
the Total flex unit cm³, l, m³, gal, kgal, Cuft, bbl, Impgal,
kImpgal, l(N), m³(N), Sl, Scuft, MMscuft, Sm³ can be selected.
l(N), m³(N) only for gas application.
Sl, Scuft, MMscuft, Sm³ only for gas application or if Reference
density value is selected.
Select: g, kg, t, lb
For Total volume unit
cm³, l, m³, gal, kgal, Cuft, bbl, Impgal, kImpgal, l(N), m³(N), Sl,
Scuft, MMscuft, Sm³
can be selected.
l(N), m³(N) only for gas application.
Sl, Scuft, MMscuft, Sm³ only for gas application or if Reference
density value is selected.
For option /CST:
When Net flow select is set to Mass,
the Total net unit g, kg, t, lb can be selected.
When Net flow select is set to Volume,
the Total net unit cm³, l, m³, gal, kgal, Cuft, bbl, Impgal, kImpgal
can be selected.
Total energy unit
Energy factor/Heat of combustion
Total switch select
Total limit switch
Total at alarm
Total reset cntrl
All Rights Reserved. Copyright © 2009, Rota Yokogawa
For option /Cxx:
Selection depends from concentration unit.
Select: MJ, Btu
Set the calorific value of the medium with the unit Energy factor/
Heat of combust. unit.
The totalized energy of the medium can be indicated on display by
F-Total energy.
Heat of combust. unit MJ/kg, Btu/lb, MJ/m³(N) and Btu/Scuft can
be selected.
Select: Flex Total, Mass Total, Volume Total, Net Total
A totalizer limit can be set only to the forward
totalizer selected in Total select. If status output is set to Total
switch, status output is set active, if the totalizer reaches this value.
Total switch is not active if set to 0.0.
Select: Hold, Continue Total
Characteristic of totalizer selected in Total select in case of the
Total switch is active.
If Hold is selected forward and reverse totalising stops.
Select: Inhibit, Enable
Enables or inhibits total reset.
3-97
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
Total reset
Select: Not Execute, Reset flex totals,
Reset mass totals, Reset volume totals,
Reset net totals, Reset all totals
After execution of reset totals, forward and reverse total of the
selected totalizer will be set to zero.
If the total value 9999999 is reached, the indication changes to exponential type. During exponential
indication the resolution is lower. If full accuracy is needed, total reset must be executed to reach precise
indication.
3.16 Flow direction function (Detailed Setup)
Flow direction
Select: Forward, Reverse
See 3.12 and 3.13 according influence on status output
(SO 1/2 function = Flow direction)
If Reverse is selected, the flow direction in the other direction of the
arrow on the detector is used as positive values of flow.
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-98
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
3.17 Concentration measurement (Detailed Setup)
Concentration meas
(only for option/CST or /Cxx)
To set the functions of concentration measurement.
For xx=00 to 99 a customer specific or defined table is stored in the
converter in factory.
For /CST temperature coefficients have to be determined by the customer.
Concentration meas unit
(only available for option/CST)
Select: °Brix, Wt-% sol, Vol% sol, Wt-%, Vol%
Concentration meas format
Select: xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX
Concentration meas LRV (low
range value)
Set a concentration value to the 4 mA or 0 Hz
Concentration meas
(upper range value)
Set a concentration value to the 20 mA or xxxxx = Hz.
Abs(URV-LRV) ≥ 10%
Concentration meas damping
Set the damping time in s. Damping time affects outputs and display.
After 5 times damping time the given value is displayed (t=63%).
Concentration meas lowcut
Set the low cut. Low cut affects outputs and display.
Concentration meas alm 1 sel
Select: No function, More than, Less than
Concentration meas alm 1 crit
Select a concentration alarm level. What happens in case of an alarm
has to be defined in Status out (3.12, 3.13).
Concentration meas alm 2 sel
Select: No function, More than, Less than
Concentration meas alm 2 crit
Select a concentration alarm level. What happens in case of an alarm
has to be defined in Status out (3.12, 3.13).
Restrictions:
All alarms have to be in 0-110%
of URV-LRV
Alarm criteria 2 must always be
larger than alarm criteria 1.
Concentration meas setup
(only for option /CST)
To setup the coefficients used for calculation of concentration using the
Standard Concentration Measurement.
Reference temperature
Set the temperature where the reference density of both components of
the mixture has been determined.
Ref. density carrier
Set the density of the carrier liquid determined at the reference temperature.
Temp. coeff. a carrier
Set the linear temperature coefficient of the density of the carrier liquid.
Temp. coeff. b carrier
Set the squared temperature coefficient of the density of the carrier liquid.
Ref. density product
Set the density of the product determined at the reference temperature.
Temp. coeff. a product
Set the linear temperature coefficient of the density of the product.
Temp. coeff. b product
Set the squared temperature coefficient of the density of the product.
For more information on concentration measurement see TI "Concentration Measurement" TI 01R04B04-04E-E.
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-99
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.18 Net flow (Detailed Setup)
Net flow
To set the functions of net flow measurement.
Net flow is only available if concentration measurement is activated
(option /Cxx or /CST). The actual flow is multiplied with the concentration).
Net flow select
(only available for option /CST)
Select: Mass, Volume
Net flow unit
When Net flow select is set to Mass:
g/s, g/min, g/h, kg/s, kg/min, kg/h, kg/d, t/min, t/h, t/d, lb/s, lb/min,
lb/h, lb/d can be selected
When Net flow select is set to Volume:
cm³/s, cm³/min, cm³/h, l/s, l/min, l/h, l/d, m³/s, m³/min, m³/h, m³/d,
gal/s, gal/min, gal/h, gal/d, Cuft/s, Cuft/min, Cuft/h, Cuft/d, bbl/s,
bbl/min, bbl/h, bbl/d, Impgal/s, Impgal/min, Impgal/h, Impgal/d
can be selected
Net flow format
Select: xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX
Net flow LRV
(low range value)
Set a net flow value to the 4 mA or 0 Hz.
Net flow URV
(upper range value)
Set a net flow value to the 20 mA or xxxxx = Hz.
Abs(URV-LRV) ≥ 5% of Qnom.
Net flow damping
Set the damping time in s. Damping time effects outputs and display.
After 5 times damping time the given value is displayed (t=63%).
Net flow lowcut
Set the low cut effects output and display. A hysteresis of 0.05% of
Qnom is given by the system.
Net flow alm 1 sel
Select: No function, More than, Less than
Net flow alm 1 crit
Select a net flow alarm level. What happens in case of an alarm has to
be defined in Status out (3.12, 3.13)
Net flow alm 2 sel
Select: No function, More than, Less than
Net flow alm 2 crit
Select a net flow alarm level. What happens in case of an alarm has to
be defined in Status out (3.12, 3.13)
Restrictions:
All alarms have to be in 0-110% of
URV-LRV
Alarm criteria 2 must always be
larger than alarm criteria 1.
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3-100
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
3.19 Slug detection (Detailed Setup)
Slug detection
Detection of bubble flow.
Not available if gas measurement After slug criteria has been reached, slug is supervised during slug
is ordered.
duration. If slug is still detected after slug duration has expired, the
selected action in After slug is taken.
See below table.
Slug alarm select
Select: Not apply, Apply
Drive gain
To read drive gain.
To set a suitable slug criteria the customer must know the drive gain
level of normal flow condition and of slug flow condition. This function is
suitable to evaluate this level.
Slug criteria
Above this drive gain level slug flow is assumed.
Slug duration
Duration time is designed to ignore short gas bubbles. Only after Slug
duration has expired the setting in After slug will be taken in account.
In normal slug application set slug duration to zero.
After slug
Select: Measured value, Hold
If Hold is selected mass flow and density keep their value before
occurrence of the slug alarm and as long as slug alarm is detected.
Drive gain damping
Set drive gain damping time to get a constant drive gain level.
Gas application?
Yes
No
Slug alarm select = Apply?
Yes
No
Drive gain > Slug criteria?
Yes
No
Duration active?
Slug detection off
Yes
After duration
Function active
Alarm off
Measurement
continued
Slug detection On
Alarm on
Measurement
continued
or value hold
Slug detection off
Slug detection off
Alarm off
Influence of slug on mass flow, density and drive gain :
mass flow, if
Hold
mass flow, if
Measured value
duration time
mass flow
density
drive gain
single
bubble
All Rights Reserved. Copyright © 2009, Rota Yokogawa
slug flow
time
T88.EPS
3-101
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.20 Empty pipe detection (Detailed Setup)
Empty pipe detection
Detection of empty pipe
Not available if gas measurement
(option /GA) is ordered.
Not working if fixed reference density is enabled.
After Empty pipe crit has been reached, alarm
output is activated if selected.
This function can also be used to detect tube failure
(see chapter 8.8).
Empty pipe alm sel
Select: Not apply, Apply
Empty pipe crit
Set density value as criteria when empty pipe alarm
should happen. If Empty pipe crit is smaller than
Density URV (or LRV, whichever is higher), alarm
appears if density is lower than Empty pipe crit.
If Empty pipe crit is equal or greater than Density
URV (or LRV, whichever is higher), alarm appears if
density is higher than Empty pipe crit.
After empty pipe
Select the behaviour of the outputs after empty pipe
has happened.
Select: Massflow = Zero, Measured Value, Hold
With this function the outputs can be set to zero if the
detector runs empty during maintenance. It is also
useful for batching if the batch starts with an empty
pipe. In such case please install the detector vertically.
Gas application?
Yes
No
Empty pipe alm sel = Apply?
Yes
Empty pipe crit < Density URV?
(or LRV, whichever is higher)
Empty pipe OFF
No
Empty pipe crit ≥ Density URV?
(or LRV, whichever is higher)
Yes
No
Yes
No
Empty pipe
ON
Empty pipe
OFF
Empty pipe
ON
Empty pipe
OFF
Empty pipe
OFF
Alarm On
if density <
empty pipe crit
Alarm off
Alarm On
if density ≥
empty pipe crit
Alarm off
Alarm off
Alarm off
Outputs either
Measured
Value, Hold or
4mA/0Hz
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
Outputs either
Measured
Value, Hold or
4mA/0Hz
3-102
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3. PARAMETER DESCRIPTION
3.21 Corrosion detection (Detailed Setup)
Corrosion detection
Detection of corrosion in pipe.
Not available if gas measurement
is ordered. Not working if fixed
reference density is enabled. This
function is useful if the max. density of the fluid is known and corrosion may happen. As alternative
to this function the user can watch
density periodically.
After density value stored in Corrosion crit has been reached, alarm
output is activated if selected.
Corrosion alm sel
Select: Not apply, Apply
Corrosion crit
Set density value up to Density URV or Density LRV (whichever is
higher)
Corrosion damp
Set damping on density for comparison with Corrosion crit, up to 10h.
This function is only good for liquids with relative constant density.
Set an upper density level. If this density level is reached permanently,
a warning occurs.
3.22 Detector data (Detailed Setup)
The sensor model is defined in Parameter Detailed Setup / Sensor model :
WARNING
The function Sensor model is only for changing a converter in case of maintenance.
Never change the sensor model if the sensor is not changed.
The sensor constants for the selected detector are stored in parameters Detailed Setup / Sensor constants.
You find the main sensor constants on the name plate. In case of doubt of the measured value please
confirm that the proper sensor constants are stored.
The serial number of the converter is stored in ´Detailed Setup / Device Information / Serial no. Converter´.
The serial number of the detector is stored in ´Detailed Setup / Device Information / Serial no. Detector´.
For compact version RCCT3 there is only one serial number.
The tag number, if provided by the customer (option /BG), is stored in Basic setup / Tag.
For integral type RCCT3x and remote type RCCF31 / RCCR31 combined ordered with RCCS3x the detector
data are factory stored in the concerning parameters. For not combined remote type RCCF31 with option
/NC see chapter 5.5.
If the parameter Detailed setup / Sensor model is changed to another type, the following parameters are
changed to new default values corresponding to the selected model :
Qnom, Mass flow unit, Mass flow LRV, Mass flow URV, Vol flow unit, Vol flow LRV,
Vol flow URV, Autozero range, Autozero fluctuation range and the sensor constants.
In this case the sensor constants, the detector serial number and, if available, the tag number must be set
to the values corresponding to the used detector as described above.
All Rights Reserved. Copyright © 2009, Rota Yokogawa
3-103
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
3. PARAMETER DESCRIPTION
3.23 Reading maximum fluid temperature (Detailed Setup)
Fluid max. temp
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
The highest measured medium temperature ever reached can be read
in this parameter.
This parameter can not be reset or changed by the user.
3-104
All Rights Reserved. Copyright © 2009, Rota Yokogawa
All Rights Reserved. Copyright © 2009, Rota Yokogawa
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
YOKOGAWA ELECTRIC CORPORATION
World Headquarters
9-32, Nakacho 2-chome, Musashino-shi
Tokyo 180-8750
Japan
www.yokogawa.com
YOKOGAWA ELECTRIC ASIA Pte. LTD.
5 Bedok South Road
Singapore 469270
Singapore
www.yokogawa.com/sg
YOKOGAWA CORPORATION OF AMERICA
2 Dart Road
Newnan GA 30265
USA
www.yokogawa.com/us
YOKOGAWA CHINA CO. LTD.
3F Tower D Cartelo Crocodile Building
No.568 West Tianshan Road Changing District
Shanghai, China
www.yokogawa.com/cn
Euroweg 2
3825 HD AMERSFOORT
The Netherlands
www.yokogawa.com/eu
YOKOGAWA MIDDLE EAST B.S.C.(c)
P.O. Box 10070, Manama
Building 577, Road 2516, Busaiteen 225
Muharraq, Bahrain
www.yokogawa.com/bh
IM 01R04B07-00E-E
3rd edition July 01, 2013-00
Yokogawa has an extensive sales and
distribution network.
Please refer to the European website
(www.yokogawa.com/eu) to contact your
nearest representative.
All Rights Reserved. Copyright © 2009, Rota Yokogawa
Subject to change without notice