Download User`s Manual
Transcript
User's Manual 3 Series Coriolis Mass Flow and Density Meter Integral Type RCCT3 Remote Type RCCF31 + RCCS3 European MID Custody Transfer Type (/Q01) IM 01R04B07-00E-E, additional manual to IM 01R04B04-00x-E Rota Yokogawa GmbH & Co. KG Rheinstr. 8 D-79664 Wehr Germany IM 01R04B07-00E-E December 2009 (Rü) 3rd edition, July 2013 (Rü) ©Copyright Blank Page CONTENTS Contents 1. About Rotamass MID Custody Transfer Type (/Q01).........................1-1 2. INSTALLATION......................................................................................2-1 2.1 General ........................................................................................................................................... 2-1 2.2 Hardware Write Protect....................................................................................2-1 2.3 Sealing..............................................................................................................2-2 3. PARAMETER DESCRIPTION...............................................................3-1 3.1 Overview...........................................................................................................3-1 3.2 Parameter list...................................................................................................3-2 3.3 Parameter tree, Display menu......................................................................3-21 3.4 Parameter tree, HART menu.........................................................................3-52 3.5 Mass flow functions (Basic or Detailed Setup)..........................................3-84 3.6 Volume flow functions (Basic or Detailed Setup).......................................3-85 3.7 Density functions (Basic or Detailed Setup)..............................................3-86 3.8 Temperature functions (Basic or Detailed Setup)......................................3-88 3.9 Velocity functions (Detailed Setup)..............................................................3-88 3.10 Analog 1 functions (Basic or Detailed Setup)..........................................3-89 3.11 Pulse/Status output 1 functions (Basic or Detailed Setup).....................3-90 3.12 Pulse/Status output 2 functions (Basic or Detailed Setup)......................3-94 3.13 Status input functions (Basic or Detailed Setup).....................................3-95 3.14 HART output (Detailed Setup)....................................................................3-96 3.15 Totalizer functions (Basic or Detailed Setup)...........................................3-97 3.16 Flow direction function (Detailed Setup)...................................................3-98 3.17 Concentration measurement (Detailed Setup)..........................................3-99 3.18 Net flow (Detailed Setup)..........................................................................3-100 3.19 Slug detection (Detailed Setup)................................................................ 3-101 3.20 Empty pipe detection (Detailed Setup)....................................................3-102 3.21 Corrosion detection (Detailed Setup)......................................................3-103 3.22 Detector data (Detailed Setup).................................................................3-103 3.23 Reading maximum fluid temperature (Detailed Setup)..........................3-104 All Rights Reserved. Copyright © 2009, Rota Yokogawa i IM 01R04B07-00E-E 3rd edition July 01, 2013-00 CONTENTS Blank Page IM 01R04B07-00E-E 3rd edition July 01, 2013-00 ii All Rights Reserved. Copyright © 2009, Rota Yokogawa 1. ABOUT ROTAMASS CUSTODY TRANSFER TYPE 1. About Rotamass MID Custody Transfer Type (/Q01) This user manual is additional to IM 01R04B04-00x-E for standard Rotamass 3 series. This manual describes the special conditions for european MID custody transfer type (option /Q01) which deviate from the standard flowmeter. Chapters 1, 2, 3, 5, 6, 8, 9, 10, and 11 of IM 01R04B04-00x-E are also valid for Custody Transfer Type. Chapter 2 of this manual replaces chapter 4 of IM 01R04B04-00x-E. Chapter 3 of this manual replaces chapter 7 of IM 01R04B04-00x-E. IMPORTANT For explosion protected instruments and instructions for PED (Pressure Equipment Directive) see IM 01R04B04-00x-E. Rotamass with custody transfer option for liquids others than water (tested according OIML R 117-1) is suitable for - - - measuring liquids, liquids with solid content, multi-phase mixtures simultaneous measurement of density, temperature and cumulated mass and volume connection to controllers and process control systems ROTAMASS provides the following I/O-connections and can be configured for a wide variety of different measurement applications (controlling, checking, monitoring, metering, mixing, filling). - 1 passive double pulse output (90 degrees phase shifted according DIN EN 6551) for custody transfer of total mass or volume - 1 analog output for density (tested for custody transfer applications) - 1 passive pulse output / status output - 1 status input The firmware is the same as in standard type. The Custody Transfer type contains the same menu tree as standard type. But some parameters can generally not be used or can only not be used with custody transfer application. NOTE Parameter which generally can not be used (e.g. because the necessary hardware is not available) are highlighted in grey in the parameter list and in the menu trees. Parameter which require special settings or where settings are restricted with custody transfer application are marked with a star " *) ". For using the Rotamass with option /Q01 for custody transfer the flowmeter must be calibrated at a certified calibration site. All Rights Reserved. Copyright © 2009, Rota Yokogawa 1-1 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 1. ABOUT ROTAMASS CUSTODY TRANSFER TYPE Initial verification: - Before calibration all necessary adjustments must be done via menu setting. - Hardware Write Protect must be set (see chapter 2.7). - The flowmeter must be sealed (see chapter 2.8). - Special density and flow DAKKS- calibration with water - No density adjustment Measuring ranges in custody transfer mode: RCCx34 RCCx36 RCCx38 RCCx39 Qmin / Qmax in kg/h 300 / 4020 780 / 15600 2400 / 49800 10020 / 132000 Minimum measured quantity in kg 20 20 100 200 Operating conditions: Maximum process pressure: Process temperature range: Ambient temperature range: Environmental class: Accuracy class: Density range: Mass flow low cut in kg/h 60 156 480 2004 20 bar -40°C ... +55°C -40°C ... +55°C M3 (e.g. truck mounting) E3 (e.g. vehicle battery supply) 0.3; 0.5 (0.7 ... 1.4) kg/l Outputs / Inputs in custody transfer mode: Current output: 1 active, 4-20 mA Pulse output: 1 passive, 2 channels A and B: 90° shifted pulse packets with pulse width 0.05 ms or 1 ms, optional NAMUR level Status output: 1 passive, off-state to indicate faults and power loss Status input: 1 passive Measurement variables in custody transfer mode: Mass (output on pulse output 1) Volume (output on pulse output 1) Density ((output on current output) Since only one pulse output is available mass and volume can not be measured simultaneously! Documentation for custody transfer: Test Report RCCF31 RCCS34 RCCS36 RCCS38 RCCS39 CPC-601228-01 CPC-900389-01 CPC-809370-01 CPC-809370-02 CPC-900389-01 Certificate TC 7531 TC 7532 TC 7532 TC 7532 TC 7532 Documentation Folder TC 7531 TC 7532 TC 7532 TC 7532 TC 7532 Test reports, certificates and special documentation folders for national type approvals are available on request. The numbers of the evaluation certificates of detector and converter according OIML R 117-1 and european directive 2004/22/EC on measuring instruments (MID) are indicated on the name plates. For integral type RCCT3x always order also the documentation for converter RCCF31. IM 01R04B07-00E-E 3rd edition July 01, 2013-00 1-2 All Rights Reserved. Copyright © 2009, Rota Yokogawa 2. INSTALLATION 2. INSTALLATION 2.1 General For installation see chapter 4 of IM 01R04B04-00E-E. Additional regard the following chapters 2.2 and 2.3 of this manual. 2.2 Hardware Write Protect For use in custody transfer application the hardware write protection must be set after setup: • Open the cover of the converter. • Unscrew the 4 screws of the display and move the display aside. • Set the jumper on JP1 of CPU-board as shown in the following picture. • Screw the display and close the cover. CPU Board JP1 Cable to display Enable Protect F64.EPS The hardware write protection is prior to any other write protection, and cannot be released by HART or other software means. NOTE If the Hardware Write Protect jumper is in the "Protect" position then all parameters and commands of the list in chapter 3.2 and the menu trees in 3.3 and 3.4 can only be read in "Read only" mode. Any writing or execution is impossible (message "Write protect"). Also Autozero is not possible. Apply the correct value for density offset before sealing the housing! This hardware protection can not be removed without breaking the sealing. All Rights Reserved. Copyright © 2009, Rota Yokogawa 2-1 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 2. INSTALLATION 2.3 Sealing Sealing is done by blocking the front window cover of the converter using the attached wire seal. The wire of the wire seal is put through the holes of the cover and the housing as shown in the figure below and then the wire is pulled through the seal again for fixing. wire seal IM 01R04B07-00E-E 3rd edition july 01, 2013-00 F44.EPS holes 2-2 All Rights Reserved. Copyright © 2009, Rota Yokogawa Mass flow unit Vol flow unit Density unit Temperature unit Velocity unit Hot key (6.3) Mass flow (7.5) Volume flow (7.6) Density (7.7)) Temperature (7.8) Velocity (7.9) Analog Output 1 (7.10) Analog Output 2 (7.11) All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-1 IM 01R04B07-00E-E Sensor model *) Distributor Poll address Detector data (7.23) Device data HART data Num req preams Tag Num resp preams Long Tag Sensor S/N Net flow (7.19) Concentration measurement (7.18) Flow direction (7.17) *) Special functions Sensor constants *) Zero adjustment (5.6) Input/ Output Test (8.4) Self test/ status (8.3) Diag/Service (8) Dips. period Total mass unit Disp. contrast Total flex unit TV is Display select Total flex select Totalizer (7.16) SV is Pulse 2 unit Pulse 1 unit *) Analog 1 low LMT Analog 2 low LMT Temperature LRV Density LRV Vol flow LRV Mass flow LRV New Password HART Display (5) PV is SI active mode SI function HART Output (7.15) Pulse 2 select Pulse/ Stat 2 select Pulse/Status out 2 (7.13) Status input (7.14) Pulse 1 select *) Pulse/ Stat 1 select *) Pulse/Status out 1 (7.12) Analog 1 alarm out Analog 2 alarm out Temperature format Density format Vol flow format Mass flow format Enable wrt 10min. HART Master reset Descriptor Slug detection (7.20) *) Autozero (7.24) Language Total volume unit QV is Pulse 2 rate Pulse 1 rate *) Analog 1 high LMT Analog 2 high LMT Temperature URV Density URV Vol flow URV Mass flow URV Software seal HART Message Empty pipe detection (7.21) Output trim (8.5) Total net unit Pulse 2 active mode Pulse 1 active mode Temperature damping Density damping Vol flow damping Mass flow damping Key Status HART Date Corrosion detection (7.22) History overview (8.2) Total energy unit Pulse 2 width Pulse 1 width *) Temperature alm 1 sel Density lowcut *) Vol flow lowcut *) Mass flow lowcut *) Dev id Fluid max. Temp. (7.25) Error history (8.2) Heat of combustion Pulse 2 at alarm Pulse 1 at alarm Temperature alm 1 crit Mass flow alm 1sel Vol flow alm 1 sel Density alm 1 sel Universal rev Gas measurement (7.26) *) Heat of combustion unit SO2 function SO1 function *) Fld dev rev Total switch select SO2 active mode SO1 active mode *) Temperature alm 2 crit Software rev Total limit switch Temperature fix val select *) Density alm 2 crit Density alm 2 sel Density alm 1 crit Temperature alm 2 sel Vol flow alm 2 crit Mass flow alm 2 crit Vol flow alm 2 sel Mass flow alm 2 sel Vol flow alm 1 crit Mass flow alm1 crit Hardware Write Protect (6.4) Parameters Hardware rev Total at alarm Temperature fixed value *) Ref. Density sel *) MF fix val sel *) Device S/W version Total reset cntrl Temperature Gain adjust *) Reference density *) MF fixed value *) Device S/W date Total reset Density offset *) Static pressure control Not available for Custody Transfer type Analog 2 select Analog 1 select *) Write Protect HART Topic 3. PARAMETER DESCRIPTION 3. PARAMETER DESCRIPTION 3.1 Overview The table below shows an overview of functions of ROTAMASS RCCT3/RCCF31/RCCR31. In brackets the related chapters in this manual are indicated. *) = Not for Custody Transfer type or special setting requested 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Differences between display and HART setting The ROTAMASS software is continuously improved. This leads to functions, which are different in HART (DD version 0402) and display setting (software version from 1.08.20) NOTE For ROTAMASS with software version 1.08.xx (xx < 20) the parameters marked with "**)" are not available. Parameters marked with "***)" are not available in software version 1.08.20. 3.2 Parameter list Parameter Write protect Data form Select Data range No Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default - Yes Enable WRT 10 min Acc. To HART - - R/W X Disable New Password ASCII 8 characters - - R/W X Space Software Seal Select Break - - R/W - - R/W - - R/W - - R/W - Keep Master reset Select Not Execute X Not Execute Execute Key Status Select Language Select Enable Enable Inhibit English X English German French Russian Mass Flow Decimal - 0 to 5 Mass flow unit R - - Volume Flow Decimal - 0 to 5 Vol flow unit R - - Density Decimal - 0 to 5 Density unit R - - Temperature Decimal - 0 to 5 Temperature unit R - - F-Total flex Decimal - Auto Total flex unit R X - - R-Total flex Decimal - Auto Total flex unit R X - - D-Total flex Decimal - Auto Total flex unit R X - - F-Total mass Decimal - Auto Total mass unit R X - - R-Total mass Decimal - Auto Total mass unit R X - - D-Total mass Decimal - Auto Total mass unit R X - - F-Total vol Decimal - Auto Total volume unit R X - - R-Total vol Decimal - Auto Total volume unit R X - - D-Total vol Decimal - Auto Total volume unit R X - - F-Total net Decimal - Auto Total net unit R X - - R-Total net Decimal - Auto Total net unit R X - - D-Total net Decimal - Auto R X - - Concentration meas Decimal 0 to 110 0 to 5 - - Net flow Decimal - 0 to 5 Total net unit Concentration meas unit Mass flow unit - - F-Total energy Decimal - Auto Total unit energy R - - Velocity Decimal - Auto Velocity unit R - - Drive gain Decimal 0 to 11 (typ.) R - - Decimal - As sel. Var. R - - Analog output 1% Decimal - 3 As sel. Var. 2 V Analog output 1 % R - - Analog output 1 mA Decimal - 2 mA R - - IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-2 R R X All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter Data form Data range Dec. point Analog output 2 Decimal - Analog output 2% Decimal - as sel. Var. 2 Analog output 2 mA Decimal - Pulse output 1 Decimal - Status output 1 ASCII Pulse output 2 Status output 2 Unit R : read W : write Exe : execute Reset Master Reset Power on Default as sel. Var. R - - % R - - 2 mA R - - 1 Hz R - - - - - R - - Decimal - 1 Hz R - - ASCII - - - R - - View input ASCII - - - R - - Self Test Select Not Execute - - R/W X Not Execute Execute Status ASCII Results of last self test - - R - - Hist Overview ord ASCII - - - R - - Hist Overview abs ASCII - - - R - - Error History ASCII - - - R - - Analog output 1 (Test) Decimal 2.0 to 22.0 2 mA W X X 4 Analog output 2 (Test) Decimal 2.0 to 22.0 2 mA W X X 4 Pulse output 1 (Test) Decimal 0 to 10000 1 Hz W X X 1000 Status Output 1 (Test) *) Select On Active - - W X X On Active Off Active Pulse output 2 (Test) Decimal 0 to 2000 1 Hz W X X 1000 Status Output 2 (Test) Select On Active - - W X X On Active Off Active Status input (Test) ASCII Open/Short - - R - - Autozero tuning Select Inhibit - - R/W X X Inhibit - - R/W X X 3 min - - Exe X X Not Execute Enable Autozero Time Select 3 min 30 s Autozero Exe Select Not Execute Execute Autozero Value Decimal depends on size 3 kg/h R X Autozero History ASCII - - - R X - - Autozero initial Decimal depends on size 3 kg/h R X - - Autozero range Decimal depends on size 3 kg/h R - - Autozero fluctuation range Decimal depends on size 3 kg/h R - - Output Trim AO 1 trim 4mA Decimal ACC To HART - - R/W - 0 Output Trim AO 2 trim 4mA Decimal ACC To HART - - R/W - 0 Output Trim AO 1 trim 20mA Decimal ACC To HART - - R/W - 0 Output Trim AO 2 trim 20mA Decimal ACC To HART - - R/W - 0 Tag ASCII 8 characters - - R/W Space Long Tag ASCII 22 characters - - R/W Space All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-3 X IM 01R04B07-00E-E 0 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter Disp select 1 Data form Select Data range Mass flow Dec. point Unit - - R : read W : write Exe : execute R/W - - R/W Reset Master Reset Power on Default X Mass flow X Density Volume flow Density Temperature Concentration Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain Disp select 2 Select Mass flow Volume flow Density Temperature Concentration Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-4 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter Disp select 3 Data form Select Data range Mass flow Dec. point Unit - - R : read W : write Exe : execute R/W - - R/W Reset Master Reset Power on Default X Temperature X F-Total mass Volume flow Density Temperature Concentration Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None Disp select 4 Select Mass flow Volume flow Density Temperature Concentration Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-5 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter Data form Disp contrast Select Data range -5 Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default - - R/W X 1.0 s - - R/W X Forward - - R/W X RCCS30LR …33: l/h X 0 -4 -3 -2 -1 0 1 2 3 4 5 Disp Period Select 0.5 s 1.0 s 2.0 s Flow direction *) Select Forward Reverse Mass flow unit Select g/s g/min RCCS34…39/ XR: m³/h g/h kg/s kg/min kg/h kg/d t/min t/h t/d lb/s lb/min lb/h lb/d Mass flow format Select xxxxxxx - - R/W X xxxx.XX xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Mass flow LRV Decimal -Qmax to Qmax 0 to 5 Mass flow unit R/W X 0 Mass flow URV Decimal -Qmax to Qmax 0 to 5 Mass flow unit R/W X Qnom Mass flow damping Decimal 0 to 200 1 Sec. R/W X 3 Mass flow lowcut *) Decimal -Qmax to Qmax 0 to 5 Mass flow unit R/W X 0 Mass flow alm 1 sel Select No function - - R/W X No function More than Less than Mass flow alm 1 crit Decimal -110% to 110% of URV 0 to 5 Mass flow unit R/W X 0 Mass flow alm 2 sel Select No function - - R/W X No function More than Less than Mass flow alm 2 crit Decimal -110% to 110% of URV 0 to 5 Mass flow unit R/W X 10 Mass flow fix val sel *) Select Inhibit - - R/W X Inhibit 0 to 5 Mass flow unit R/W X 0 Enable Mass flow fixed val *) IM 01R04B07-00E-E Decimal 0 to Qnom 3rd edition July 01, 2013-00 3-6 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter Vol flow unit Data form Select Data range cm³/s Dec. point - Unit - R : read W : write Exe : execute R/W Reset Master X cm³/min Reset Power on Default RCCS30LR …33: l/h RCCS34…39/ XR: m³/h cm³/h l/s l/min l/h l/d m³/s m³/min m³/h m³/d gal/s gal/min gal/h gal/d Cuft/s Cuft/min Cuft/h Cuft/d bbl/s bbl/min bbl/h bbl/d lmpgal/s lmpgal/min lmpgal/h Impgal/d l(N)/s *) l(N)/min *) l(N)/h *) l(N)/d *) m³(N)/s *) m³(N)/min *) m³(N)/h *) m³(N)/d *) Sl/s *) Sl/min *) Sl/h *) Sl/d *) Scuft/s *) Scuft/min *) Scuft/h *) Scuft/d *) Sm³/s *) Sm³/min *) Sm³/h *) Sm³/d *) Vol flow format Select xxxxxxx - - R/W X xxxx.XX xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-7 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter Data form Data range Dec. point Unit Vol flow LRV Decimal -Qvmax to Qvmax 0 to 5 Vol flow unit R : read W : write Exe : execute R/W Reset Master Reset Power on Default Vol flow URV Decimal -Qvmax to Qvmax 0 to 5 Vol flow unit R/W X Qvnom Vol flow damping Decimal 0 to 200 1 Sec. R/W X 3 Vol flow lowcut *) Decimal -Qvmax to Qvmax 0 to 5 Vol flow unit R/W X 0 Vol flow alm 1 sel Select No function - - R/W X No function X 0 More than Less than Vol flow alm 1 crit Decimal -110% to 110% of URV 0 to 5 Vol flow unit R/W X 0 Vol flow alm 2 sel Select No function - - R/W X No function More than Less than Vol flow alm 2 crit Decimal -110% to 110% of URV 0 to 5 Vol flow unit R/W X 10 Density unit Select g/ml - - R/W X kg/l - - R/W X xx.XXXX kg/l kg/m³ lb/gal lb/Cuft g/cm³ g/l °Bé hv *) °Bé lt *) °API *) Density format Select xxxxxxx xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Density LRV Decimal 0 to 5 kg/l 0 to 5 Density unit R/W X 0.0 Density URV Decimal 0 to 5 kg/l 0 to 5 Density unit R/W X 1.5 Density damping Decimal 0 to 200 1 Sec. R/W X 15.0 Density lowcut *) Decimal 0 to 5 kg/l 0 to 5 Density unit R/W X 0.0 Density alm 1 sel Select No function - - R/W X No function More than Less than Density alm1 crit Decimal 0 to 5 kg/l 0 to 5 Density unit R/W X LRV Density alm 2 sel Select No function - - R/W X No function More than Less than Density alm 2 crit Decimal 0 to 5 kg/l 0 to 5 Density unit R/W X URV Ref. Density sel *) **) Select Inhibit - - R/W X Inhibit - - R/W X Inhibit Fixed Calculated Density fix val sel *) ***) Select Inhibit Enable *) Reference Density *) Decimal 0 to 5 kg/l 0 to 5 Density unit R/W X 1.0 Density offset *) Decimal -9999.99 to +9999.99 2 g/l R/W X 0 Pressure Decimal 0 to 400 2 bar R/W 0 Pressure unit Select bar - - R/W bar psi MPa IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-8 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter Temperature unit Data form Select Data range degC Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default - - R/W X xxxxxx.X 0 to 5 Temperature unit R/W X -200 0 to 5 Temperature unit R/W X 230 X degC degF K Temperature format Select xxxxxxx xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Temperature LRV Decimal Standard: -200 to 230°C High Temp.: 0 to 400°C Temperature URV Decimal Standard: -200 to 230°C High Temp.: 0 to 400°C Temperature damping Decimal 0 to 200 1 Sec. R/W X 3 Temp alm 1 sel Select No function - - R/W X No function More than Less than Temp alm 1 crit Decimal Standard: -200 to 200°C 0 to 5 Temperature unit R/W X LRV Temp alm 2 sel Select No function - - R/W X No function 0 to 5 Temperature unit R/W X URV - - R/W X X Inhibit 1 Temperature unit R/W X X 30 More than Less than Temp alm 2 crit Decimal Standard: -200 to 230°C High Temp.: 0 to 400°C Temp fix val select *) Select Inhibit Enable Temp fixed val *) Decimal Standard: -200 to 230°C High Temp.: 0 to 400°C Temp gain *) Decimal 0.8 to 1.2 3 - R/W Velocity unit Select m/s - - R/W X 1 m/s - - R/W X Mass flow - - R/W X <3.6mA ft/s Analog 1 select *) Select Mass flow Volume flow Density Temperature Concentration meas Net flow None Analog 1 alarm out Select <2.4mA <3.6mA 4.0mA >21mA >21.6mA Hold Measured Value Analog 1 low LMT Decimal 2.4 to 21.6 mA 2 mA R/W X 3.8 Analog 1 high LMT Decimal 2.4 to 21.6 mA 2 mA R/W X 20.5 Analog 2 select Select Mass flow - - R/W X Density Volume flow Density Temperature Concentration meas Net flow None All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-9 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter Analog 2 alarm out Data form Select Data range <2.4mA Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default X <3.6mA <3.6mA 4.0mA >21mA >21.6mA Hold Measured Value Analog 2 low LMT Decimal 2.4 to 21.6 mA 2 mA R/W X 3.8 Analog 2 high LMT Decimal 2.4 to 21.6 mA 2 mA R/W X 20.5 Pulse/Stat 1 select *) Select Pulse - - R/W X Pulse - - R/W X F-Total mass - - R/W X kg/P Status out *) No function *) Pulse 1 select *) Select Mass flow Volume flow Density Temperature Concentration Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net *) R-Total net *) Pulse 1 unit *) Select Hz g/P kg/P *) t/P *) lb/P *) cm³/P l/P *) m³/P *) gal/P *) kgal/P *) Cuft/P *) bbl/P *) lmpgal/P *) klmpgal/P *) l(N)/P *) m³(N)/P *) SI/P *) Scuft/P *) Sm³/P *) Pulse 1 rate *) *) Decimal 0 to 11000 Unit/ P 0 to 10000 Hz 0 to 5 0 Pulse 1 unit R/W X 1 kg/P Pulse 1 active mode Select On Active - - R/W X On Active Off Active IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-10 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter Pulse 1 width *) Data form Select Data range 0.05ms Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default - - R/W X 0P/Hz - - R/W X No function - - R/W X On Active - - R/W X Status out X 1ms 0.1ms *) 0.5ms *) 1ms 5ms *) 10ms *) 50ms *) 100ms *) 500ms *) 1000ms *) Pulse 1 at alarm Select 0P/0Hz Measured Value Hold SO 1 function *) Select No function Flow-Direction Total limit switch Mass flow alm 1 Mass flow alm 2 Mass flow alm 1+2 Vol flow alm 1 Vol flow alm 2 Vol flow alm 1+2 Density alm 1 Density alm 2 Density alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Concentr. meas alm 1 Concentr. meas alm 2 Concentr. meas alm 1+2 Net flow alm 1 Net flow alm 2 Net flow alm 1+2 Slug alarm Empty alarm Corrosion alarm All alarms All errors All alarms & errors SO 1 active mode *) Select On Active Off Active Pulse/Stat 2 select Select Pulse Status out No function All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-11 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter Pulse 2 select Data form Select Data range Mass flow Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default - - R/W X Hz X Temperature Volume flow Density Temperature Concentration Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net R-Total net Pulse 2 unit Select Hz g/P kg/P t/P lb/P cm³/P l/P m³/P gal/P kgal/P Cuft/P bbl/P lmpgal/P klmpgal/P l(N)/P *) m³(N)/P *) SI/P *) Scuft/P *) Sm³/P *) Pulse 2 rate Decimal 0 to 11000 Unit/P 0 to 2000 Hz 0 to 5 0 Pulse 2 unit R/W X 2000 Hz Pulse 2 active mode Select On Active - - R/W X On Active - - R/W - - R/W Off Active Pulse 2 width Select 0.05ms 1ms 0.1ms 0.5ms 1ms 5ms 10ms 50ms 100ms 500ms 1000ms Pulse 2 at alarm Select 0P/0Hz X 0P/0Hz Measured Value Hold IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-12 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter SO 2 function Data form Select Data range No function Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default - - R/W X On active - - R/W X Mass flow X No Function Flow-Direction Total limit switch Mass flow alm 1 Mass flow alm 2 Mass flow alm 1+2 Vol flow alm 1 Vol flow alm 2 Vol flow alm 1+2 Density alm 1 Density alm 2 Density alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Concentr. meas alm 1 Concentr. meas alm 2 Concentr. meas alm 1+2 Net flow alm 1 Net flow alm 2 Net flow alm 1+2 Slug alarm Empty alarm Corrosion alarm All alarms All errors All alarms & errors SO 2 active mode Select On active Off active PV is Select Mass flow Volume flow Density Temperature Concentration meas Net flow None All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-13 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter SV is Data form Select Data range Mass flow Dec. point Unit - - R : read W : write Exe : execute R/W - - R/W Reset Master Reset Power on Default X Density X F-Total mass Volume flow Density Temperature Concentration meas Net flow None F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain TV is Select Mass flow Volume flow Density Temperature Concentration meas Net flow None F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-14 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter QV is Data form Select Data range Mass flow Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default - - R/W X No function - - R/W X On Active - - R/W X Flex total X Temperature Volume flow Density Temperature Concentration meas Net flow None F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain SI function Select No function Autozero Reset flex totals Reset mass totals Reset volume totals Reset net totals Reset all totals 0% Signal lock SI Active mode Select On active Off active Total flex select Select Flex total Mass total Volume total Net total All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-15 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter Total flex unit Data form Select Data range g Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default - - R/W X kg - - R/W X l - - R/W X kg - - R/W X Mass X kg kg t lb cm³ l m³ gal kgal Cuft bbl Impgal klmpgal I(N) *) m³(N) *) SI *) Scuft *) MMscuft *) Sm³ *) Total mass unit Select g kg t lb Total volume unit Select cm³ l m³ gal kgal Cuft bbl Impgal klmpgal I(N) *) m³(N) *) SI *) Scuft *) MMscuft *) Sm³ *) Total net unit Select g kg t lb cm³ l m³ gal kgal Cuft bbl Impgal klmpgal Total switch select Select Mass Volume Net IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-16 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter Data form Data range Dec. point Unit Total limit switch Decimal 0 to 9999999 0 to 5 Total unit R : read W : write Exe : execute R/W Total unit energy Select MJ - - R/W Reset Master Reset Power on Default X 0 X MJ Btu Energy factor/ heat of combustion Energy factor/ heat of combust unit Decimal 0 to 100000 0 to 5 heat of combust unit R/W Select MJ/kg - - R/W X MJ/kg - - R/W X Hold - - R/W X Inhibit - - R/W X 10 Btu/lb MJ/m³(N) *) Btu/Scuft *) Total at alarm Select Hold Continue Total Total reset cntrl Select Inhibit Enable Total reset Select Not Execute X Not Execute Reset flex totals Reset mass totals Reset volume totals Reset net totals Reset all totals SK20 *) Decimal 0 to 5 MHz×kg/h R/W 124 SKT *) Decimal 0 to 5 E-4×1/K R/W -7,34 SKTK *) Decimal 0 to 5 E-7×1/K2 R/W 19,6 RV *) Decimal 0 to 5 %/(kg/l) R/W 0,24 Qnom *) Decimal auto Mass flow unit R 10 KD *) Decimal 0 to 5 kg/l R/W 4,4 fl20 *) Decimal 0 to 5 Hz R/W 177,1 FTC1 *) Decimal 0 to 5 E-4×1/K R/W -2,179 FTCK *) Decimal 0 to 5 E-7×1/K2 R/W -0,539 SKP *) Decimal 0 to 5 E-4×1/bar R/W -0,346 SKPT *) Decimal 0 to 5 E-7×1/(bar×K) R/W 0 FPC *) Decimal 0 to 5 E-4×1/bar R/W 0,173 FPTC *) Decimal 0 to 5 E-7×1/(bar×K) R/W 0,02 FQC1 *) Decimal 0 to 5 E-10×s/g R/W 0 FQC2 *) Decimal 0 to 5 E-13×(s/g)2 R/W -40,8 Poll Adress Decimal 0 - R/W 0 Num req pream Decimal 0 - R 5 Num resp pream Decimal 0 - R/W Reference temperature Decimal 1 Temperature unit R/W X 25 Ref. density carrier Decimal 0 to 5 Density unit R/W X 0,997 Temp. coeff. a carrier Decimal 0 to 5 E-3×(1/Temp unit) R/W X -0,261 Temp. coeff. b carrier Decimal 0 to 5 E-5×(1/Temp unit2) R/W X -0,36 Ref. density product Decimal 0 to 5 Density unit R/W X 0 Temp. coeff. a product Decimal 0 to 5 E-3×(1/Temp unit) R/W X 0 Temp. coeff. b product Decimal 0 to 5 E-5×(1/Temp unit2) R/W X 0 Temp. coeff. a **) Decimal 0 to 5 E-3×(1/Temp unit) R/W X 0 Temp. coeff. b **) Decimal 0 to 5 E-5×(1/Temp unit2) R/W X 0 Concentration meas unit Select - - R/W X Wt-% 0 to 15 5 to 20 °Brix 5 Wt -% sol X Vol % sol X Wt -% X Vol % X All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-17 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter Data form Concentration meas format Select Data range xxxxxxx Dec. point - Unit - R : read W : write Exe : execute R/W Reset Master X xxxxx.X X xxxx.XX X xxx.XXX X xx.XXXX X x.XXXXX Reset Power on Default xxxx.XX X Concentration meas LRV Decimal 0 to 110 0 to 5 Concentration meas unit Concentration meas URV Decimal 0 to 110 0 to 5 Concentration meas unit R/W X 100 Concentration meas Damp Decimal 0 to 200 1 Sec R/W X 10 Concentration meas lowcut Decimal 0 to 10% 0 to 5 Concentration meas unit R/W Conc meas alm 1 sel Select No function - - R/W X No function R/W X 0 0 More than Less than Conc meas alm 1 crit Decimal 0 to 110% of URV 0 to 5 Concentration meas unit R/W X LRV Conc meas alm 2 sel Select No function - - R/W X No function More than Less than Conc meas alm 2 crit Decimal 0 to 110% of URV 0 to 5 Concentration meas unit R/W X URV Net flow select Select Mass - - R/W X Mass Volume IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-18 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Parameter Net flow unit Data form Select Data range g/s Dec. point - Unit - R : read W : write Exe : execute R/W Reset Master X g/min Reset Power on Default RCCS30LR-33: kg/h RCCS34-39/ XR: t/h g/h kg/s kg/min kg/h t/min t/h lb/s lb/min lb/h cm³/s cm³/min cm³/h l/s l/min l/h l/d m³/s m³/min m³/h m³/d gal/s gal/min gal/h gal/d Cuft/s Cuft/min Cuft/h Cuft/d bbl/s bbl/min bbl/h bbl/d lmpgal/s lmpgal/min lmpgal/h Impgal/d Net flow format Select xxxxxxx - - R/W X xxxx.XX xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Net flow LRV Decimal -Qmax to Qmax 0 to 5 Net flow unit R/W X 0 Net flow URV Decimal -Qmax to Qmax 0 to 5 Net flow unit R/W X Qnom Net flow damping Decimal 0 to 200 1 Sec R/W X 3 Net flow lowcut Decimal -Qmax to Qmax 0 to 5 Net flow unit R/W X 0.0 Net flow alm 1 sel Select No function - - R/W X No function 0 to 5 Net flow unit R/W X LRV More than Less than Net flow alm 1 crit Decimal -110% to 110% of URV All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-19 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Parameter Net flow alm 2 sel Data form Select Data range No function Dec. point Unit - - R : read W : write Exe : execute R/W Reset Master Reset Power on Default X No function X URV More than Less than Net flow alm 2 crit Decimal -110% to 110% of URV 0 to 5 Net flow unit R/W Measuring range Select Namur - - R - - R/W Namur Not Namur Slug alarm select *) Select Not Apply X Not Apply Apply Drive gain *) Decimal 0 to 11 (typ.) 3 V R Slug criteria *) Decimal 0 to 13.3 3 V R/W X 11 Slug duration *) Decimal 0 to 120 0 Sec. R/W X After slug Select Measured value - - R/W X 1 Measured value Drive gain damping Decimal 0 to 200 1 Sec. R/W X 1 Empty pipe alm sel Select Not Apply - - R/W X Not Apply Hold Apply Empty pipe crit Decimal 0 to Density URV 0 to 5 Density unit R/W X 0 After empty pipe Select Massflow=Zero - - R/W X Massflow= Measured value Zero Hold Corrosion alm sel Select Not Apply - - R/W X Not Apply Apply Corrosion criteria Decimal 0 to Density URV 0 to 5 Density unit R/W X 1,5 Corrosion damp Decimal 0 to 10 1 h R/W X 10 Fluid max temp Decimal - 1 Temperature unit R - Distributor ASCII - - - R Yokogawa Descriptor ASCII 16 characters - - R/W Space Message ASCII 32 characters - - R/W Space Date ASCII dd/mm/yyyy - - R/W 01/01/2011 Sensor model *) Select RCCS30LR *) - - R/W RCCS36 RCCS30 *) RCCS31 *) RCCS32 *) RCCS33 *) RCCS34 RCCS36 RCCS38 RCCS39 RCCS39/IR *) RCCS39/XR *) Sensor S/N Decimal 7 digits - - R 0 (not used) Assembly number Decimal 7 digits - - R 0 (not used) Serial no. Converter ASCII 16 char. - - R fix Serial no. Detector ASCII 16 char. - - R fix Universal rev Decimal 7 digits - - R fix Fld. dev rev. Decimal 3 digits - - R fix Software rev Decimal 3 digits - - R fix Hardware rev Decimal 3 digits - - R fix Device id Decimal 7 digits - - R Device S/W version ASCII 20 char. - - R Device S/W date ASCII dd/mm/yyyy - - R 7xxxxxx RCCT3 Vx.xx.xx Rx-x-x xx/xx/xxxx IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-20 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION 3.3 Parameter tree, Display menu Language English German French Russian Process View fld dev vars Variables View outputs Mass flow R Volume flow R Density R Temperature R Concentration meas R Net flow R F-Total flex R R-Total flex R D-Total flex R F-Total mass R R-Total mass R D-Total mass R F-Total volume R R-Total volume R D-Total volume R F-Total net R R-Total net R D-Total net R F-Total energy R Velocity R Drive gain R Analog output 1 Analog output 2 Pulse/Status out 1 Pulse/Status out 2 Analog Output 1 R Analog Output 1% R Analog Output 1mA R Analog Output 2 R Analog Output 2% R Analog Output 2mA R Pulse output 1 R Status output 1 R Pulse output 2 R Status output 2 R View input Totalizer R Total reset cntrl Inhibit Sel Enable Total reset All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-21 Not Execute Reset flex totals EXE Reset mass totals EXE Reset volume totals EXE Reset net totals EXE Reset all totals EXE IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Diag/Service Self test/Status Self Test Status Hist Overfiew ord Hist Overfiew abs Input/Output test Auto zero check Autozero LCD Test EXE Self Test EXE Key Test EXE Event Overview R Error R Alarm R Warning R Hist Overview ord R Clear History EXE Hist Overview abs R Error R Alarm R Warning R Clear History EXE Error History R Analog output 1 R/W Analog output 2 R/W Pulse output 1 R/W Status output 1 *) R/W Pulse output 2 R/W Status output 2 R/W Status input R Autozero history R Autozero initial R Autozero range R Autozero fluctuation range R Zero tuning Inhibit Sel Enable Autozero time 3min Sel 30s Output trim IM 01R04B07-00E-E Autozero Exe EXE Autozero value R AO 1 trim 4mA EXE AO 1 trim 20mA EXE AO 2 trim 4mA EXE AO 2 trim 20mA EXE 3rd edition July 01, 2013-00 3-22 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup Tag R/W Long Tag R/W Display config Disp select 1 Mass flow Sel Volume flow Density Temperature Concentration meas Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain Disp select 2 Mass flow Sel Volume flow Density Temperature Concentration meas Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-23 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Basic Setup Disp select 3 Mass flow Sel Volume flow Density Temperature Concentration meas Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None Disp select 4 Mass flow Sel Volume flow Density Temperature Concentration meas Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-24 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup Display contrast -5 Sel -4 -3 -2 -1 0 +1 +2 +3 +4 +5 Mass flow Mass flow unit g/s Sel g/min g/h kg/s kg/min kg/h kg/d t/min t/h t/d lb/s lb/min lb/h lb/d Density Mass flow LRV R/W Mass flow URV R/W Mass flow damping R/W Density unit g/ml Sel kg/l kg/m³ lb/gal lb/Cuft g/cm³ g/l °Bé hv *) °Bé lt *) °API *) Density LRV R/W Density URV R/W Density damping R/W All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-25 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Basic Setup Temperature Temperature unit degC Sel degF K Analog 1 select *) Temperature LRV R/W Temperature URV R/W Temperature damping R/W Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None Analog 2 select Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None Pulse/Status out 1 Pulse/Stat 1 select Pulse Sel Status Out *) No Function *) Pulse 1 select Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net R-Total net IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-26 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup Pulse 1 unit Hz Sel g/P kg/P *) t/P *) lb/P *) cm³/P l/P *) m³/P *) gal/P *) kgal/P *) Cuft/P *) bbl/P *) Impgal/P *) klmpgal/P *) I(N)/P *) m³(N)/P *) SI/P *) Scuft/P *) Sm³/P *) Pulse 1 rate SO 1 function *) R/W No Function Sel Flow direction Total limit switch Mass flow alm 1 Mass flow alm 2 Mass flow alm 1+2 Vol flow alm 1 Vol flow alm 2 Vol flow alm 1+2 Density alm 1 Density alm 2 Density alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Concentr. meas alm 1 Concentr. meas alm 2 Concentr. meas alm 1+2 Net flow alm 1 Net flow alm 2 Net flow alm 1+2 Slug Alarm Empty alarm Corrosion Alarm All alarms All errors All alarms & errors All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-27 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Basic Setup Pulse/Status out 2 Pulse/Stat 2 select Pulse Sel Status Out No Function Pulse 2 select Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net R-Total net Pulse 2 unit Hz Sel g/P kg/P t/P lb/P cm³/P l/P m³/P gal/P kgal/P Cuft/P bbl/P Impgal/P klmpgal/P I(N)/P m³(N)/P SI/P Scuft/P *) Sm³/P *) Pulse 2 rate IM 01R04B07-00E-E 3rd edition July 01, 2013-00 R/W 3-28 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup SO 2 function No Function Sel Flow direction Total limit switch Mass flow alm 1 Mass flow alm 2 Mass flow alm 1+2 Vol flow alm 1 Vol flow alm 2 Vol flow alm 1+2 Density alm 1 Density alm 2 Density alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Concentr. meas alm 1 Concentr. meas alm 2 Concentr. meas alm 1+2 Net flow alm 1 Net flow alm 2 Net flow alm 1+2 Slug Alarm Empty alarm Corrosion Alarm All alarms All errors All alarms & errors SI function No function Sel Autozero Reset flex totals Reset mass totals Reset volume totals Reset net totals Reset all totals 0% signal lock Totalizer Total flex select Mass Sel Volume Net All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-29 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Basic Setup Total flex unit g Sel kg t lb cm³ l m³ gal kgal Cuft bbl Impgal Klmpgal I(N) m³(N) SI Scuft MMscuft Sm³ Total mass unit g Sel kg t lb Total volume unit cm³ Sel l m³ gal kgal Cuft bbl Impgal Klmpgal I(N) *) m³(N) *) SI *) Scuft *) MMscuft *) Sm³ *) IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-30 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup Total net unit g kg t lb cm³ l m³ gal kgal Cuft bbl Impgal Klmpgal Total switch select Flex total Sel Mass total Volume total Net total Detailed Setup Display config Disp select 1 Mass flow Sel Volume flow Density Temperature Concentration meas Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-31 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Disp select 2 Mass flow Sel Volume flow Density Temperature Concentration meas Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None Disp select 3 Mass flow Sel Volume flow Density Temperature Concentration meas Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-32 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Disp select 4 Mass flow Sel Volume flow Density Temperature Concentration meas Net flow F-Total flex R-Total flex D-Total flex F-Total mass R-Total mass D-Total mass F-Total volume R-Total volume D-Total volume F-Total net R-Total net D-Total net F-Total energy Velocity Drive gain None Display contrast -5 Sel -4 -3 -2 -1 0 +1 +2 +3 +4 +5 Disp period 0.5s Sel 1.0s 2.0s Language English Sel German French Russian All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-33 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Sensor model RCCS30LR *) Sel RCCS30 *) RCCS31 *) RCCS32 *) RCCS33 *) RCCS34 RCCS36 RCCS38 RCCS39 RCCS39/IR *) RCCS39/XR *) Sensor constants *) Mass flow Density Config fld variables Flow direction *) SK20 R/W SKT R/W SKTK R/W RV R/W Qnom R SKP R/W SKPT R/W KD R/W fl20 R/W FTC1 R/W FTCK R/W FPC R/W FPTC R/W FQC1 R/W FQC2 R/W Forward Sel Reverse IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-34 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Mass flow Mass flow unit g/s Sel g/min g/h kg/s kg/min kg/h kg/d t/min t/h t/d lb/s lb/min lb/h lb/d Mass flow format xxxxxxx Sel xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Mass flow LRV R/W Mass flow URV R/W Mass flow damping R/W Mass flow lowcut *) R/W Mass flow alm 1 sel No function Sel More than Less than Mass flow alm 1 crit Mass flow alm 2 sel R/W No function Sel More than Less than Mass flow alm 2 crit Mass flow fix val sel R/W Inhibit Sel Enable *) Mass flow fixed val *) All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-35 R/W IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Volume flow Vol flow unit cm³/s Sel cm³/min cm³/h l/s l/min l/h l/d m³/s m³/min m³/h m³/d gal/s gal/min gal/h gal/d Cuft/s Cuft/min Cuft/h Cuft/d bbl/s bbl/min bbl/h bbl/d Impgal/s Impgal/min Impgal/h Impgal/d I(N)/s *) I(N)/min *) I(N)/h *) l(N)/d *) m³(N)/s *) m³(N)/min *) m³(N)/h *) m³(N)/d *) SI/s *) SI/min *) SI/h *) Sl/d *) Scuft/s *) Scuft/min *) Scuft/h *) Scuft/d *) Sm³/s *) Sm³/min *) Sm³/h *) Sm³/d *) IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-36 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Vol flow format xxxxxxx Sel xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Vol flow LRV R/W Vol flow URV R/W Vol flow damping R/W Vol flow lowcut *) R/W Vol flow alm 1 sel No function Sel More than Less than Vol flow alm 1 crit Vol flow alm 2 sel R/W No function Sel More than Less than Vol flow alm 2 crit Density Density unit R/W g/ml Sel kg/l kg/m³ lb/gal lb/Cuft g/cm³ g/l °Bé hv *) °Bé lt *) °API *) Density format xxxxxxx Sel xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX All Rights Reserved. Copyright © 2009, Rota Yokogawa Density LRV R/W Density URV R/W Density damping R/W 3-37 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Density lowcut *) R/W No function Density alm 1 sel Sel More than Less than Density alm 1 crit R/W No function Density alm 2 sel Sel More than Less than Density alm 2 crit R/W Ref. Density sel **) Inhibit Sel Fixed Calculated Reference density R/W Reference density setup Reference Temperature R/W **) Density fix val sel ***) Temp. coeff. a R/W Temp. coeff. b R/W Inhibit Sel Enable *) Density offset *) R/W bar Pressure Unit Sel psi MPa Pressure Temperature R/W degC Temperature unit Sel degF K Temperature format xxxxxxx Sel xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Temperature LRV IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-38 R/W All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Temperature URV R/W Temperature damping R/W Temp alm 1 sel No function Sel More than Less than Temp alm 1 crit Temp alm 2 sel R/W No function Sel More than Less than Temp alm 2 crit Temp fix val select R/W Inhibit Sel Enable *) Velocity unit Temp fixed value *) R/W Temp gain *) R/W m/s Sel ft/s Config Output/Input Analog output 1 Analog 1 select *) Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None Analog 1 alarm Out <2.4 mA Sel <3.6 mA <4.0 mA >21.0 mA >21.6 mA Hold Measured value All Rights Reserved. Copyright © 2009, Rota Yokogawa Analog 1 low LMT R/W Analog 1 high LMT R/W 3-39 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Analog output 2 Analog 2 select Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None Analog 2 alarm Out <2.4 mA Sel <3.6 mA <4.0 mA >21.0 mA >21.6 mA Hold Measured value Pulse/Status out 1 Analog 2 low LMT R/W Analog 2 high LMT R/W Pulse/Stat 1 select Pulse Sel Status out *) No function *) Pulse 1 select Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net R-Total net IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-40 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Pulse 1 unit Hz Sel g/P kg/P *) t/P *) lb/P *) cm³/P l/P *) m³/P *) gal/P *) kgal/P *) Cuft/P *) bbl/P *) lmpgal/P *) klmpgal/P *) I(N)/P *) m³(N)/P *) SI/P *) Scuft/P *) Sm³/P *) Pulse 1 rate *) Pulse 1 active mode R/W On Active Sel Off Active Pulse 1 width 0.05ms Sel 0.1ms *) 0.5ms *) 1ms 5ms *) 10ms *) 50ms *) 100ms *) 50ms *) 1000ms *) Pulse 1 at alarm 0P/0Hz Sel Measured value Hold All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-41 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup No Function SO 1 function *) Sel Flow direction Mass flow alm 1 Mass flow alm 2 Mass flow alm 1+2 Vol flow alm 1 Vol flow alm 2 Vol flow alm 1+2 Density alm 1 Density alm 2 Density alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Concentr. meas alm 1 Concentr. meas alm 2 Concentr. meas alm 1+2 Net flow alm 1 Net flow alm 2 Net flow alm 1+2 Slug Alarm Empty alarm Corrosion Alarm All alarms All errors All alarms & errors SO1 active mode *) On Active Sel Off Active Pulse/Status out 2 Pulse/Stat 2 select Pulse Sel Status out No function Pulse 2 select Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net R-Total net IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-42 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Pulse 2 unit Hz Sel g/P kg/P t/P lb/P cm³/P l/P m³/P gal/P kgal/P Cuft/P bbl/P lmpgal/P klmpgal/P I(N)/P *) m³(N)/P *) SI/P *) Scuft/P *) Sm³/P *) Pulse 2 rate Pulse 2 active mode R/W On Active Sel Off Active Pulse 2 width 0.05ms Sel 0.1ms 0.5ms 1ms 5ms 10ms 50ms 100ms 50ms 1000ms Pulse 2 at alarm 0P/0Hz Sel Measured value Hold All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-43 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup SO2 function No Function Sel Flow direction Total limit switch Mass flow alm 1 Mass flow alm 2 Mass flow alm 1+2 Vol flow alm 1 Vol flow alm 2 Vol flow alm 1+2 Density alm 1 Density alm 2 Density alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Concentr. meas alm 1 Concentr. meas alm 2 Concentr. meas alm 1+2 Net flow alm 1 Net flow alm 2 Net flow alm 1+2 Slug Alarm Empty alarm Corrosion Alarm All alarms All errors All alarms & errors SO2 active mode On Active Sel Off Active Status input SI function No function Sel Autozero Reset flex totals Reset mass totals Reset volume totals Reset net totals Reset all totals 0% signal lock SI active mode On Active Sel Off Active IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-44 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup HART output PV is Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None SV is Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net R-Total net F-Total flex R-Total flex D-Total mass D-Total volume D-Total net D-Total flex F-Total energy Velocity Drive gain TV is Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net R-Total net F-Total flex R-Total flex D-Total mass D-Total volume D-Total net D-Total flex F-Total energy Velocity Drive gain All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-45 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup QV is Mass flow Sel Volume flow Density Temperature Concentration meas Net flow None F-Total mass R-Total mass F-Total volume R-Total volume F-Total net R-Total net F-Total flex R-Total flex D-Total mass D-Total volume D-Total net D-Total flex F-Total energy Velocity Drive gain Totalizer Total flex select Mass Sel Volume Net Total flex unit g Sel kg t lb cm³ l m³ gal kgal Cuft bbl Impgal Klmpgal I(N) *) m³(N) *) SI *) Scuft *) MMscuft *) Sm³ *) Total mass unit g Sel kg t lb IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-46 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Total volume unit cm³ Sel l m³ gal kgal Cuft bbl Impgal kimpgal I(N) *) m³(N) *) SI *) Scuft *) MMscuft *) Sm³ *) Total net unit g kg t lb cm³ l m³ gal kgal Cuft bbl Impgal kimpgal Total unit energy MJ Sel Btu Energy factor Heat of combustion R/W Heat of combustion unit MJ/kg Sel Btu/lb MJ/m³(N) *) Btu/Scuft *) Total switch select Flex total Sel Mass total Volume total Net total Total limit switch Total at alarm R/W Hold Sel Continue total Total reset cntrl Inhibit Sel Enable All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-47 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Total reset Not Execute Reset flex totals Exe Reset mass totals Exe Reset volume totals Exe Reset net totals Exe Reset all totals Exe HART communication Poll addr Concentration setup Concentration meas R/W Num req pream R/W Num resp pream R/W Master reset Exe Reference Temperature R/W Ref. density carrier R/W Temp. coeff. a carrier R/W Temp. coeff. b carrier R/W Ref. density product R/W Temp. coeff. a product R/W Temp. coeff. b product R/W Concentr. meas unit °Brix Sel Wt-% sol Vol% sol Vol% Wt-% Concentr. meas format xxxxxxx Sel xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX IM 01R04B07-00E-E Concentr.meas LRV R/W Concentr. meas URV R/W Concentr. meas Damp R/W Concentr. meas Lowcut R/W 3rd edition July 01, 2013-00 3-48 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Conc meas alm 1 Sel No function Sel More than Less than Conc meas alm 1 Crit Conc meas alm 2 Sel R/W No function Sel More than Less than Conc meas alm 2 crit Net flow Net flow select R/W Mass Sel Volume Net flow unit g/s Sel g/min g/h kg/s kg/min kg/h kg/d t/min t/h t/d lb/s lb/min lb/h lb/d cm³/s cm³/min cm³/h l/s l/min l/h l/d m³/s m³/min m³/h m³/d gal/s gal/min gal/h gal/d Cuft/s Cuft/min Cuft/h Cuft/d bbl/s bbl/min bbl/h All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-49 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION bbl/d Detailed Setup Impgal/s Impgal/min Impgal/h Impgal/d Net flow format xxxxxxx Sel xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Net flow LRV R/W Net flow URV R/W Net flow damping R/W Net flow lowcut R/W Net flow Alm 1 Sel No function Sel More than Less than Net flow Alm 1 Crit Net flow Alm 2 Sel R/W No function Sel More than Less than Net flow Alm 2 Crit R/W Measuring range Slug detection R Slug alarm select Not apply Sel Apply *) Drive gain *) R Slug criteria *) R/W Slug duration *) R/W After slug *) Measured value *) Sel Holdv Drive gain damping *) IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-50 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Empty pipe detect Empty pipe alm sel Not apply Sel Apply Empty pipe crit After empty pipe R/W Massflow=Zero Sel Measured Value Hold Corrosion detect Corrosion alm sel Not apply Sel Apply Corrosion crit R/W Corrosion damp R/W Fluid max temp Device information R Distributor R Tag R/W Long Tag R/W Descriptor R/W Message R/W Date R/W Sensor model R Sensor S/N R Assembly number R Serial no. converter R Serial no. detector R Device S/W Device S/W version R Device S/W date R Device id R Universal rev R Fld dev rev R Software rev R Hardware rev R All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-51 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.4 Parameter tree, HART menu Online Device setup PV PV AO Review Service Set parameters for Rotamass (see below) Display process value in engineering unit Display analogue output in mA Review parameters for Rotamass (see below) Not open Device setup Language English German French Russian Process variables View fld dev vars Mass flo Volume flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain View Outputs Analog output 1 Analog 1 select PV PV AO % rnge R R R R Analog output 2 Analog 2 select SV SV AO % rnge R R R R Pulse/Status out 1 Pulse 1 select TV TV Freq SO 1 function *) SO 1 mode *) No function R R R R R R IM 01R04B07-00E-E Sel 3rd edition July 01, 2013-00 R R R R R R R R R R R R R R R R R R R R R 3-52 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Pulse/Status out 2 Diag/ Service Pulse 2 select QV QV Freq SO 2 function SO 2 mode No function R R R R R R View Input Input function Totalizer Total res cntrl Inhibit Enable Sel Total reset Not execute Reset flex totals Reset mass totals Reset volume totals Reset net totals Reset all totals Exe Exe Exe Exe Exe Exe Self test LCD/Key Test Self Test Exe Exe Status Event overview Error Alarm Warning R R R R Hist Overview ord Hist Overview ord Clear History ord Self test/Status Hist Overview abs R History Set History Set menu Not execute Execute Abs Set 1 : Set 10 R R History Set Hist overview H. error H. Alarm H. Warning R R R R R Clear History abs Input/Output test R Exe Analog Out 1 Analog Out 2 Pulse Out 1 Status Out 1 *) Pulse Out 2 Status Out 2 Status Input All Rights Reserved. Copyright © 2009, Rota Yokogawa R Sel R/W R/W R/W R/W R/W R/W R 3-53 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Diag/ Service Auto zero check Autozero Loop trim Autozero history Data Set 1 Newest 2 3 4 5 Oldest Initial R Date R Val R Dens R Temp R AZ range R AZ fluctuation R Zero tuning Inhibit Enable Autozero Autozero duration Sel 3min 30s Sel Perform auto zero Exe Autozero value R Trim output 1 Exe Trim output 2 Exe Tag R/W Long Tag R/W IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-54 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup Display config Disp select 1 Mass flo Vol flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain Sel Disp select 2 Mass flo Vol flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain None Sel All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-55 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Basic Setup Display contrast IM 01R04B07-00E-E Disp select 3 Mass flo Vol flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain None Sel Disp select 4 Mass flo Vol flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain None Sel -5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5 3rd edition July 01, 2013-00 Sel 3-56 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup Mass flo Dens Mass flo unit g/s g/min g/h kg/s kg/min kg/h kg/d t/min t/h t/d lb/s lb/min lb/h lb/d Sel Mass flo LRV R/W Mass flo URV R/W Mass flo Damping R/W Dens unit g/mL kg/L kg/m3 lb/gal Sel lb/Cuft g/cm3 g/L °Bé hv *) °Bé lt *) °API *) Temp Analog 1 select *) Density LRV R/W Density URV R/W Density damping R/W Temp unit degC degF K Sel Temp LRV R/W Temp URV R/W Temp Damping R/W Mass flo Vol flo Density Temperature Conc meas Net flo None Sel All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-57 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Basic Setup Analog 2 select Pulse/Status out 1 Mass flo Vol flo Density Temperature Conc meas Net flo None Sel Pulse/Stat 1 select *) Pulse Status out *) No function Sel Pulse out 1 Pulse 1 select Mass flo Vol flo Dens Temp Conc meas Net flo None F-Totl mass R-Totl mass F-Totl vol R-Totl vol F-Totl net *) R-Totl net *) Sel TV Pls unit Hz g/P kg/p *) t/P *) lb/P *) cm3/P L/P *) m3/P *) gal/P *) kgal/P *) Cuft/P *) bbl/P *) Impgal/P *) klmpgal/P *) L(N)/P *) m3(N)/P *) L(Std)/P *) StdCuft/P *) m3(Std)/P *) Sel TV Pls rate IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-58 R/W All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup Pulse/Status out 2 Status out 1 *) SO 1 function Pulse/Stat 2 select Pulse Status out No function Pulse out 2 Pulse 2 select All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-59 No Function Flow direction Total Switch Mass flo alm 1 Mass flo alm 2 Mass flo alm 1+2 Vol flo alm 1 Vol flo alm 2 Vol flo alm 1+2 Dens alm 1 Dens alm 2 Dens alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Conc alm 1 Conc alm 2 Conc alm 1+2 Net flo alm 1 Net flo alm 2 Net flo alm 1+2 Slug Alarm Empty Alarm Corrosion Alarm All Alarms All Errors All Alarms & Errors Sel Sel Mass flo Vol flo Dens Temp Conc meas Net flo None F-Totl mass R-Totl mass F-Totl vol R-Totl vol F-Totl net R-Totl net IM 01R04B07-00E-E Sel 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Basic Setup QV Pls unit Hz g/P kg/p t/P lb/P cm3/P L/P m3/P gal/P kgal/P Cuft/P bbl/P Impgal/P klmpgal/P L(N)/P *) m3(N)/P *) L(Std)/P *) StdCuft/P *) m3(Std)/P *) QV Pls rate Status out 2 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 SO 2 function 3-60 Sel R/W No Function Flow direction Total Switch Mass flo alm 1 Mass flo alm 2 Mass flo alm 1+2 Vol flo alm 1 Vol flo alm 2 Vol flo alm 1+2 Dens alm 1 Dens alm 2 Dens alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Conc alm 1 Conc alm 2 Conc alm 1+2 Net flo alm 1 Net flo alm 2 Net flo alm 1+2 Slug Alarm Empty Alarm Corrosion Alarm All Alarms All Errors All Alarms & Errors Sel All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Basic Setup Input function Totalizer No function Autozero Reset flex totals Reset mass totals Reset volume totals Reset net totals Reset all totals 0% Signal lock Sel Total flex select Mass Volume Net F-Totl flex Unit g kg t lb cm3 L m3 gal kgal Cuft bbl Impgal klmpgal L(N) *) m3(N) *) L(Std) *) StdCuft *) MMscuft *) m3(Std) *) F-Totl mass Unit g kg t lb Sel F-Totl vol Unit cm3 L m3 gal kgal Cuft bbl Impgal klmpgal L(N) *) m3(N) *) L(Std) *) StdCuft *) MMscuft *) m3(Std) *) Sel All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-61 Sel IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Basic Setup Detailed Setup Display config IM 01R04B07-00E-E F-Totl net Unit g kg t lb cm3 L m3 gal kgal Cuft bbl Impgal klmpgal L(N) *) m3(N) *) L(Std) *) StdCuft *) MMscuft *) m3(Std) *) Sel Total switch select Flex total Mass total Volume total Net total Sel Disp Select 1 Mass flo Vol flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain Sel 3rd edition July 01, 2013-00 3-62 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Disp Select 2 Mass flo Vol flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain None Sel Disp Select 3 Mass flo Vol flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain None Sel All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-63 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Sensor model IM 01R04B07-00E-E Disp Select 4 Mass flo Vol flo Dens Temp Conc meas Net flo F-Totl flex R-Totl flex D-Totl flex F-Totl mass R-Totl mass D-Totl mass F-Totl vol R-Totl vol D-Totl vol F-Totl net R-Totl net D-Totl net F-Totl energy Velocity Drive Gain None Sel Display contrast -5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5 R/W Display period 0.5s 1.0s 2.0s Sel Language English German French Russian Sel RCCS30LR *) RCCS30 *) RCCS31 *) RCCS32 *) RCCS33 *) RCCS34 RCCS36 RCCS38 RCCS39 RCCS39/IR *) RCCS39/XR *) 3rd edition July 01, 2013-00 Sel 3-64 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Sensor constants *) Mass flo SK20 R/W SKT R/W SKTK R/W RV R/W Qnom R SKP R/W SKPT R/W KD R/W Fl20 R/W FTC1 R/W FTCK R/W FPC R/W FPTC R/W FQC1 R/W FQC2 R/W Flow direction *) Forward Reverse Sel Mass flo Mass flo unit g/s g/min g/h kg/s kg/min kg/h kg/d t/min t/h td lb/s lb/min lb/h lb/d Sel Mass flo format xxxxxxx xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Sel Density Config fld var All Rights Reserved. Copyright © 2009, Rota Yokogawa Mass flo LRV R/W Mass flo URV R/W 3-65 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Mass flo damping R/W Mass flo lowcut *) R/W Mass flo alm 1 sel No function More than Less than Mass flo alm 1 crit Mass flow alm 2 sel R/W No function More than Less than Mass flo alm 2 crit Vol flo IM 01R04B07-00E-E 3rd edition July 01, 2013-00 Sel Sel R/W Mass flo fix sel Inhibit Enable *) Sel Mass flo fix menu *) Mass flo fixed val R/W Vol flo Unit cm3/s cm3/min cm3/h L/s L/min L/h L/d m3/s m3/min m3/h m3/d gal/s gal/min gal/h gal/d Cuft/s Cuft/min Cuft/h Cuft/d bbl/s bbl/min bbl/h bbl/d Impgal/s Impgal/min Impgal/h Impgal/d L(N)/s *) L(N)/min *) L(N)/h *) L(N)/d *) m3(N)/s *) m3(N)/min *) m3(N)/h *) m3(N)/d *) Sel 3-66 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup L(Std)/s *) L(Std)/min *) L(Std)/h *) L(Std)/d *) StdCuft/s *) StdCuft/min *) StdCuft/h *) StdCuft/d *) m3(Std)/s *) m3(Std)/min *) m3(Std)/h *) m3(Std)/d *) Vol flo Format xxxxxxx xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Vol flo LRV R/W Vol flo URV R/W Vol flo damping R/W Vol flo Lowcut *) R/W Vol flo alm 1 sel No function More than Less than Vol flo alm 1 crit Vol flow alm 2 sel All Rights Reserved. Copyright © 2009, Rota Yokogawa Sel R/W No function More than Less than Vol flo alm 2 crit Dens Sel Sel R/W Dens Unit g/mL kg/L kg/m3 lb/gal lb/Cuft g/cm3 g/L °Bé hv °Bé lt °API Sel Dens Format xxxxxxx xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Sel 3-67 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Dens LRV R/W Dens URV R/W Dens damping R/W Dens lowcut *) R/W Dens alm 1 sel No function More than Less than Dens alm 1 crit Dens alm 2 sel R/W No function More than Less than Dens alm 2 crit Ref. Density sel *) **) Inhibit Fixed Calculated Sel Fixed ref dens menu *) **) Reference density R/W Ref density setup *) **) Ref. temperature R/W Temp. coeff a R/W Temp. coeff b R/W Dens fix val sel ***) Inhibit Enable *) Sel Dens fix menu ***) Reference density R/W Pressure Unit R/W bar psi MPa Pressure 3rd edition July 01, 2013-00 Sel R/W Temp Unit degC degF K Sel Temp Format xxxxxxx xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Sel Temp LRV IM 01R04B07-00E-E Sel R/W Density offset Temp Sel 3-68 R/W All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Temp URV R/W Temp damping R/W Temp alm 1 sel No function More than Less than Temp alm 1 crit Temp alm 2 sel R/W No function More than Less than Temp alm 2 crit Config Output/Input Sel Sel R/W Temp fix val sel Inhibit Enable Sel Temp fix menu Temp fixed value Temp gain adjust R/W Velocity unit m/s ft/s Sel Analog output 1 Analog 1 select *) Mass flo Vol flo Dens Temp Conc meas Net flo None Sel Analog 1 alarm Out <2.4mA <3.6mA <4.0mA >21.0mA >21.6mA Hold Measured value Sel Analog 1 low LMT Analog 1 high LMT Analog output 2 All Rights Reserved. Copyright © 2009, Rota Yokogawa R/W R/W Analog 2 select Mass flo Vol flo Dens Temp Conc meas Net flo None Sel SV Analog 2 alarm Out <2.4mA <3.6mA <4.0mA >21.0mA >21.6mA Hold Measured value Sel 3-69 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Analog 2 low LMT Analog 2 high LMT Detailed Setup IM 01R04B07-00E-E Pulse/Status 1 3rd edition July 01, 2013-00 R/W R/W Pulse/Stat 1 sel Pulse Status out *) No function *) Pulse/freq out 1 Pulse 1 select Mass flo Vol flo Dens Temp Conc meas Net flo None F-Totl mass R-Totl mass F-Totl vol R-Totl vol F-Totl net R-Totl net Sel Freq/Pulse out 1 TV Pls unit Hz g/P kg/P *) t/P *) lb/P *) cm3/P L/P *) m3/P *) gal/P *) kgal/P *) Cuft/P *) bbl/P *) Impgal/P *) kImpgal/P *) L(N)/P *) m3(N)/P *) L(Std)/P *) StdCuft/P *) m3(Std)/P *) Sel TV Pls rate *) R/W TV Pls mode On Active Off Active Sel TV Pls width 0.05ms 0.1ms *) 0.5ms *) 1ms 5ms *) 10ms *) 50ms *) 100ms *) 500ms *) 1000ms *) Sel 3-70 Sel All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup TV Pls alarm 0 Hz / 0 Pulses Hold Measured value Status out 1 *) Pulse/Status 2 All Rights Reserved. Copyright © 2009, Rota Yokogawa SO 1 function No function Sel Flow direction Total switch Mass flo alm 1 Mass flo alm 2 Mass flo alm 1+2 Vol flo alm 1 Vol flo alm 2 Vol flo alm 1+2 Dens alm 1 Dens alm 2 Dens alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Conc alm 1 Conc alm 2 Conc alm 1+2 Net flo alm 1 Net flo alm 2 Net flo alm 1+2 Slug Alarm Empty Alarm Corrosion Alarm All alarms All errors All alarms & errors SO 1 active mode On Active Off Active Pulse/Stat 2 sel Pulse Status out No function Pulse/freq out 2 Pulse 2 select 3-71 Sel Sel Sel Mass flo Vol flo Dens Temp Conc meas Net flo None F-Totl mass R-Totl mass F-Totl vol R-Totl vol F-Totl net R-Totl net IM 01R04B07-00E-E Sel 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup IM 01R04B07-00E-E Freq/Pulse out 2 3rd edition July 01, 2013-00 3-72 QV Pls unit Hz g/P kg/P t/P lb/P cm3/P L/P m3/P gal/P kgal/P Cuft/P bbl/P Impgal/P kImpgal/P L(N)/P m3(N)/P L(Std)/P StdCuft/P m3(Std)/P Sel QV Pls rate R/W QV Pls mode On Active Off Active Sel QV Pls width 0.05ms 0.1ms 0.5ms 1ms 5ms 10ms 50ms 100ms 500ms 1000ms Sel QV Pls alarm 0 Hz / 0 Pulses Hold Measured value Sel All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Status out 2 Status input All Rights Reserved. Copyright © 2009, Rota Yokogawa SO 2 function No function Sel Flow direction Total switch Mass flo alm 1 Mass flo alm 2 Mass flo alm 1+2 Vol flo alm 1 Vol flo alm 2 Vol flo alm 1+2 Dens alm 1 Dens alm 2 Dens alm 1+2 Temp alm 1 Temp alm 2 Temp alm 1+2 Conc alm 1 Conc alm 2 Conc alm 1+2 Net flo alm 1 Net flo alm 2 Net flo alm 1+2 Slug alarm Empty alarm Corrosion alarm All alarms All errors All alarms & errors SO 2 active mode On Active Off Active Sel Input function No Function Autozero Reset flex totals Reset mass totals Reset volume totals Reset net totals Reset all totals 0% signal lock Sel SI active mode On Active Off Active Sel 3-73 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup IM 01R04B07-00E-E HART Output 3rd edition July 01, 2013-00 PV is Mass flo Vol flo Dens Temp Conc meas Net flo None SV is Mass flo Vol flo Dens Temp Conc meas Net flo None F-Totl mass R-Totl mass F-Totl vol R-Totl vol F-Totl net R-Totl net F-Totl flex R-Totl flex D-Totl mass D-Totl vol D-Totl net D-Totl flex F-Totl energy Velocity Drive Gain TV is Mass flo Vol flo Dens Temp Conc meas Net flo None F-Totl mass R-Totl mass F-Totl vol R-Totl vol F-Totl net R-Totl net F-Totl flex R-Totl flex D-Totl mass D-Totl vol D-Totl net D-Totl flex F-Totl energy Velocity Drive Gain 3-74 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup QV is Totalizer Total flex select Mass Volume Net F-Totl flex Unit g kg t lb cm3 L m3 gal kgal Cuft bbl Impgal klmpgal L(N) *) m3(N) *) L(Std) *) StdCuft *) MMscuft *) m3(Std) *) F-Totl mass Unit g kg t lb All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-75 Mass flo Vol flo Dens Temp Conc meas Net flo None F-Totl mass R-Totl mass F-Totl vol R-Totl vol F-Totl net R-Totl net F-Totl flex R-Totl flex D-Totl mass D-Totl vol D-Totl net D-Totl flex F-Totl energy Velocity Drive Gain Sel IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup F-Totl vol Unit cm3 L m3 gal kgal Cuft bbl Impgal klmpgal L(N) *) m3(N) *) L(Std) *) StdCuft *) MMscuftv m3(Std)v Sel F-Totl net Unit g kg t lb cm3 L m3 gal kgal Cuft bbl Impgal klmpgal L(Std) *) StdCuft *) MMscuft *) m3(Std) *) Sel F-Totl energy Unit MJ Btu Sel Energy factor Heat of combust unit Total switch select Sel Heat of combustion R/W Flex Mass Volume Net Sel Total limit switch IM 01R04B07-00E-E MJ/kg Btu/lb MJ/Nm3 *) Btu/Scuft *) R/W Total at alarm Hold continue Sel Total res cntrl Inhibit Enable Sel 3rd edition July 01, 2013-00 3-76 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Total reset HART communication Conc meas setup Conc meas Not execute Reset flex total Reset mass total Reset volume total Reset net total Reset all totals Exe Exe Exe Exe Exe Exe Poll addr R/W Num req pream R/W Num resp preams R/W Master reset Exe Ref. temperature R/W Ref. dens. carrier R/W Coeff. a carrier R/W Coeff b carrier R/W Ref. dens. product R/W Coeff. a product R/W Coeff. b product R/W Conc meas unit degBrix % sol-wt % sol-vol Wt-% Vol-% Sel Conc meas Format xxxxxxx xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Sel Conc meas LRV R/W Conc meas URV R/W Conc meas Damp R/W Conc meas Lowcut R/W Conc meas alm 1 sel No function More than Less than Sel Conc meas alm 1 crit All Rights Reserved. Copyright © 2009, Rota Yokogawa R/W 3-77 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Conc meas alm 2 sel No function More than Less than Conc meas alm 2 crit Net flo IM 01R04B07-00E-E Net flow select Sel R/W Mass Volume Not applicable Sel Net flo Unit g/s g/min g/h kg/s kg/min kg/h kg/d t/min t/h t/d lb/s lb/min lb/h lb/d cm3/s cm3/min cm3/h L/s L/min L/h L/d m3/s m3/min m3/h m3/d gal/s gal/min gal/h gal/d Cuft/s Cuft/min Cuft/h Cuft/d bbl/s bbl/min bbl/h bbl/d Impgal/s Impgal/min Impgal/h Impgal/d Sel Net flo Format xxxxxxx xxxxx.X xxxx.XX xxx.XXX xx.XXXX x.XXXXX Sel 3rd edition July 01, 2013-00 3-78 R All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Detailed Setup Net flo LRV R/W Net flo URV R/W Net flo Damp R/W Net flo lowcut R/W Net flo alm 1 sel No function More than Less than Sel Net flo alm 1 crit Net flo alm 2 sel R/W No function More than Less than Sel Net flo alm 2 crit R/W Measuring Range Slug detection *) R Slug alarm select Not apply Apply Sel Slug detection Drive gain R Slug criteria R/W Slug duration R/W After slug Measured value Hold Sel Drive gain damping Empty pipe detect Empty pipe alm sel Not apply Apply Sel Empty pipe detect Empty pipe crit R/W After empty pipe Corrosion detect Massflow =Zero Measured Value Hold Sel Corrosion alm sel Not apply Apply Sel Corrosion detect Corrosion crit R/W Corrosion damp R/W Fluid max temp All Rights Reserved. Copyright © 2009, Rota Yokogawa R 3-79 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Detailed Setup Review Device info Device information Tag R/W Long Tag R/W Descriptor R/W Message R/W Date R/W Sensor model R Sensor S/N R Final asmbly num R S/N Converter R S/N Detector R Revision #‘s Universal rev Fld dev rev Software rev Hardware rev R R R R Device S/W Device S/W version Device S/W date R R Distributor Sensor model Sensor S/N Final asmbly num R R R R Tag Long Tag Describtor Message Date R R R R R Dev id Universal rev Fld dev rev Software rev Hardware rev R R R R R Device S/W version Device S/W date S/N Converter S/N Detector R R R R IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-80 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Review Sensor SK20 *) SKT *) SKTKv RV *) Qnom *) SKP *) SKPT *) R R R R R R R KD *) fl20 *) FTC1 *) FTCK *) FPC *) FPTC *) FQC1 *) FQC2 *) R R R R R R R R Autozero value R Rev Fld Dev Flow direction *) vars 1 Mass flo unit Mass flo LRV Mass flo URV Mass flo damp Mass flo lowcut *) Mass flo alm 1 sel Mass flo alm 1 crit Mass flo alm 2 sel Mass flo alm 2 crit Mass flo fixed value *) R R R R R R R R R R R Vol flo unit Vol flo LRV Vol flo URV Vol flo damp Vol flo lowcut *) Vol flo alm 1 sel Vol flo alm 1 crit Vol flo alm 2 sel Vol flo alm 2 crit R R R R R R R R R Dens unit Dens LRV Dens URV Dens damp Dens lowcut *) Dens alm 1 sel Dens alm 1 crit Dens alm 2 sel Dens alm 2 crit Reference density *) Density offset Pressure Pressure unit R R R R R R R R R All Rights Reserved. Copyright © 2009, Rota Yokogawa R R R R 3-81 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Rev Fld Dev Temperature unit vars 1 Temp LRV Temp URV Temp damp Temp range select Temp alm 1 select Temp alm 1 crit Temp alm 2 select Temp alm 2 crit Temp fixed value *) R R R R R R R R R R Velocity unit R Rev Fld Dev Conc meas Unit vars 2 Conc meas LRV Conc meas URV Conc meas damp Conc meas lowcut Conc alm 1 select Conc alm 1 crit Conc alm 2 sel Conc alm 2 crit R R R R R R R R R Net flo select Net flo unit Net flo LRV Net flo URV Net flo damping Net flo lowcut Net flo alm 1 sel Net flo alm 1 crit Net flo alm 2 sel Net flo alm 2 crit R R R R R R R R R R Rev Outputs Analog 1 select *) /Input PV Alarm 1 select PV Analog 1 low LMT PV Analog 1 high LMT R R R R Analog 2 select SV Alarm 2 select SV Analog 2 low LMT SV Analog 2 high LMT R R R R Pulse/Stat 1 sel Pulse 1 select *) Pls Unit Pls Rate *) Pls Mode Pls Width *) Pls Alarm SO 1 function *) SO 1 active mode *) R R R R R R R R Pulse/Stat 2 select Pulse 2 select Pls Unit R R R IM 01R04B07-00E-E 3rd edition July 01, 2013-00 R 3-82 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Rev HART Pls Rate Pls Mode Pls Width Pls Alarm SO 2 function SO 2 active mode R R R R R R Input function SI active mode R R PV is SV is TV is QV is R R R R Total flex select F-Totl flex Unit F-Totl mass Unit F-Totl vol Unit F-Totl net Unit R R R R R F-Totl energy Unit Heat of combust unit Heat of combustion R R R Total switch sel Total limit switch Total at alarm Total res cntrl R R R R Poll addr Num req pream Num resp pream R R R All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-83 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.5 Mass flow functions (Basic or Detailed Setup) Mass flow To set the functions of mass flow measurement. Mass flow unit Select: g/s, g/min, g/h, kg/s, kg/min, kg/h, kg/d, t/min, t/h, t/d, lb/s, lb/min, lb/h, lb/d Mass flow format Select: xxxxxxx,xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX Mass flow LRV (low range value) Set a mass flow value to the 4 mA or 0 Hz. LRV can also be negative to measure reverse flow. Mass flow URV (upper range value) Set a mass flow value to the 20 mA or xxxxxHz. Abs(URV-LRV) ≥ 5% of Qnom for liquids and 1% for gases Mass flow damping Set the damping time in s. Damping time affects outputs and display. After 5 times damping time the given value is displayed (t=63%). Mass flow lowcut Set the low cut. Low cut affects outputs and display and applies to negative and positive flow. A hysteresis of 0.05% of Qnom is given by the system. Mass flow alm 1 sel Select: No function, More than, Less than Mass flow alm 1 crit Select a mass flow alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13). Mass flow alm 2 sel Select: No function, More than, Less than Mass flow alm 2 sel Restrictions: All alarms have to be in 0-110% of URV-LRV. Alarm criteria 2 must always be larger than alarm criteria 1. Select a mass flow alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13). Mass flow fix val sel Select: Inhibit, Enable Mass flow fixed value Select a fix Mass flow value (only for test purpose or in case of maintenance). The set value is added to the actual value. In case of no flow it will vary with the zero fluctuation. IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-84 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION 3.6 Volume flow functions (Basic or Detailed Setup) Volume flow To set the functions of volume flow measurement. Notice: Volume flow is derived density and mass flow measurement. Errors in density measurement (e.g. from gas bubbles) effects the accuracy of volume flow. For liquid it is recommended to use mass flow as original measurement. Density below roh = 0.3 kg/l volume flow is set to zero (for liquids) Vol flow unit Select: cm³/s, cm³/min, cm³/h, l/s, l/min, l/h, l/d, m³/s, m³/min, m³/h, m³/d, gal/s, gal/min, gal/h, gal/d, Cuft/s, Cuft/min, Cuft/h, Cuft/d, bbl/s, bbl/min, bbl/h, bbl/d, Impgal/s, Impgal/min, Impgal/h, Impgal/d, I(N)/s, I(N)/min, I(N)/h, l(N)/d, m³(N)/s, m³(N)/min, m³(N)/h, m³(N)/d, SI/s, SI/min, SI/h, Sl/d, Scuft/s, Scuft/min, Scuft/h, Scuft/d, Sm³/s, Sm³/min, Sm³/h, Sm³/d I(N)/s, I(N)/min, I(N)/h, l(N)/d, m³(N)/s, m³(N)/min, m³(N)/h, m³(N)/d only for gas application. SI/s, SI/min, SI/h, Sl/d, Scuft/s, Scuft/min, Scuft/h, Scuft/d, Sm³/s, Sm³/min, Sm³/h, Sm³/d only for gas application or if Reference density value is selected. Vol flow format Select; xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX Vol flow LRV (low range value) Set a volume flow value to the 4 mA or 0 Hz. LRV can also be negative to measure reverse flow. Vol flow URV (upper range value) Set a volume flow value to the 20 mA or xxxxx Hz. Abs(URV-LRV) ≥ 5% of Qvnom for liquids. For gas application Abs(URV-LRV) ≥ 1% Vol flow damping Set the damping time in s. Damping time affects outputs and display. After 5 times damping time the given value is displayed (t=63%) Vol flow lowcut Set the low cut. Low cut affects outputs and display. Any low cut on mass flow will affect volume flow also. A hysteresis of 0.05% of Qnom on mass flow is given by the system. Vol flow alm 1 sel Select: No function, More than, Less than Vol flow alm 1 crit Select a volume flow alarm level. What happens in case of an alarm has to be defined in Status (3.12, 3.13). Vol flow alm 2 sel Select: No function, More than, Less than Vol flow alm 2 crit Restrictions: All alarms have to be in 0-110% of URV-LRV. Alarm criteria 2 must always be larger than alarm criteria 1. Select a volume flow alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13). All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-85 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.7 Density functions (Basic or Detailed Setup) Density To set the functions of density measurement. Notice: Density measurement is only reliable if there is no gas in the liquid. For liquid measurement a density lower 0.3 kg/l is displayed as 0.0 kg/l. For gas measurement set a fixed density value. Density unit Select: g/ml, kg/l, kg/m³, lb/gal, lb/Cuft, g/cm³, g/l, °Bé hv, °Bé lt, °API °Bé hv, °Bé lt, °API only with option /CST Density format Select: xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX Density LRV (low range value) Set a density value to the 4 mA or 0 Hz. Density URV (upper range value) Set a density value to the 20 mA or xxxxx Hz. Abs(URV-LRV) ≥ 0.05 kg/l Density damping Set the damping time in s. Damping time affects outputs and display. After 5 times damping time the given value is displayed (t=63%) Density lowcut Set the low cut. Low cut affects outputs and display. Density alm 1 sel Select: No function, More than, Less than Density alm 1 crit Select a density alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13). Density alm 2 sel Select: No function, More than, Less than Density alm 2 crit Restrictions: All alarms have to be in 0-110% of URV-LRV Alarm criteria 2 must always be larger than alarm criteria 1. Select a density alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13). Density Fix val sel (only software revision lower than 1.8.20) Select: Inhibt, Enable Ref. Density sel (from software revision 1.8.20) Select: Inhibit, Fixed, Calculated If Fixed or Calculated is selected, reference density and corrected volume flow is output. Otherwise measured density and volume flow is output. Calculated reference density is not available if concentration measurement (option /Cxx) or gas measurement (option /GA) is activated. Reference density IM 01R04B07-00E-E Set a fixed reference density value. For gas measurement (option / GA) set here your actual density for output of volume flow. For output of standard or normal volume flow set the standard or normal density of your gas accordingly. For liquid measurement this parameter can also be used to enter the standard density of your liquid for output of standard volume flow or for the actual density in case of density disturbances. 3rd edition July 01, 2013-00 3-86 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Reference density setup (from software revision 1.8.20) To setup the coefficients used for calculating the reference density. ρref = ρ (1 + a Δt + b Δt²) ; Δt = t - tref ρref : density at reference temperature ρ : measured density t : measured temperature tref : reference temperature a : linear thermal expansion coefficient b : quadratic thermal expansion coefficient Reference temperature (from software revision 1.8.20) Set the reference temperature for the reference density calculation. Temp. coeff. a (from software revision 1.8.20) Set the linear thermal expansion coefficient of the liquid for the reference density calculation. Temp. coeff. b (from software revision 1.8.20) Set the quadratic thermal expansion coefficient of the liquid for the reference density calculation. Density offset If the Rotamass detector is installed horizontally (bend down) the value from the following table must be entered according to the concerning sensor model. RCCS30LR 5.25 g/l RCCS30 2.70 g/l RCCS31 1.80 g/l RCCS32 2.00 g/l RCCS33 0.60 g/l RCCx34 0.90 g/l RCCx36 0.35 g/l RCCx38 to 39/XR 0 g/l (default) ROTAMASS is density-calibrated vertically. If the ROTAMASS detector is installed horizontal an density offset value from the above table has to be entered to the parameter reference density. As positive values if the tubes are down and as negative value if the tubes are up. Pressure Set the average static line pressure. Static pressure effect on density and mass flow will be corrected automatically. Pressure unit Select: bar, psi, MPa All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-87 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.8 Temperature functions (Basic or Detailed Setup) Temperature To set the functions of temperature measurement. Notice: Standard range: -200 to 230°C High temp. range (/HT): 0 to 400°C Temperature Unit Select: degC, degF, K Temperature format Select: xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX Temperature LRV (low range value) Set a temperature value to the 4 mA or 0 Hz Temperature URV (upper range value) Set a temperature value to the 20 mA or xxxxx Hz. Abs(URV-LRV) ≥ 10K Temperature damping Set the damping time in s. Damping time affects outputs and display. After 5 times damping time the given value is displayed (t=63%). Temperature alm 1 sel Select: No function, More than, Less than Temperature alm 1 crit Select a temperature alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13). Temperature alm 2 sel Select: No function, More than, Less than Temperature alm 2 crit Select a temperature alarm level. Restrictions: What happens in case of an alarm has to be defined in Status out (3.12, All alarms have to be in 0-110% 3.13). of URV-LRV Alarm criteria 2 must always be larger than alarm criteria 1. Temperature fix val select Select: Inhibit, Enable Temperature fixed value Select a temperature value in case of malfunction of the built in temperature sensor. Temperature gain Change the gain by setting a factor different from 1. The ROTAMASS temperature sensor is installed outside of the measuring tubes. So at high or low fluid temperature the temperature measurement may show a deviation as a function of the quality of heat insulation. This function allows correcting temperature measurement for better accuracy in mass flow and density. Note: It is not recommended to use this function unless correct measurement over the complete process temperature range can be confirmed. It is not sufficient to proof correct measurement at one temperature or in a very narrow temperature range unless the process operates exclusively within this range. 3.9 Velocity functions (Detailed Setup) Velocity To set the function of the medium velocity. Not available for gas measurement (/GA) Velocity is not calculated if reference density is enabled. Velocity unit Select: m/s, ft/s IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-88 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION 3.10 Analog 1 functions (Basic or Detailed Setup) Analog output 1 To set the current output 1. This output provides HART communication. Analog 1 select Select: Mass flow (0), Volume flow (1), Density (2), Temperature (3), Concentration meas (4), Net flow (5), None (6) Numbers may be displayed if selected via HART. If None is selected, output is 4 mA, HART communication is available. Analog 1 alarm out (Detailed setup, configure output/input) Select: <2.4 mA, <3.6 mA, <4 mA, >21 mA, >21.6 mA Analog 1 low LMT Default: 3.8mA (low limit) Setting range: 3.8 - 20.5 mA (Detailed setup, configure output/ input) The alarm is active if the measured value is lower than the low limit. Analog 1 high LMT Default: 20.5mA (high limit) Setting range: 3.8 - 20.5 mA (Detailed setup, Configure output/ input) The alarm is active if the measured value is higher than the high limit. Example for Bi-directional flow (NAMUR): 110 21.6 100 20 High-LMT 20.5 mA 18.4 90 16.8 LRV < 0 (e.g. -100% of flow) 70 15.2 60 13.6 50 12 40 10.4 30 8.8 20 7.2 5.6 10 possible Low cut 0 -110 -10 -90 -70 -50 -30 -10 0 10 30 Reverse ← Flow [%] → Forward All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-89 50 Output current [mA] Output current [%] 80 70 90 4 Low-LMT 3.8 mA 1102.4 T76a.EPS IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.11 Pulse/Status output 1 functions (Basic or Detailed Setup) Pulse/Status out 1 To set the pulse/status output 1. Pulse/Stat 1 select Select: Pulse out, Status out, No function If Pulse is selected, Status out 1 (SO) is not available. If Status out is selected, pulse parameters are not available. Pulse 1 select Select: Mass flow (0), Volume flow (1), Density (2), Temperature (3), Concentration meas (4), Net flow (5), None (6), F-Total mass (7), R-Total mass (8), F-Total volume (9), R-Total volume (10), F-Total net (11), R-Total net (12) Numbers may be displayed if selected via HART. If F-Total mass, F-Total volume or F-Total net are selected, pulse output only works at forward flow. If R-Total mass, R-Total volume or R-Total net are selected, pulse output only works at reverse flow. Pulse 1 unit Select: Hz, g/P, kg/P, t/P, lb/P, cm³/P, l/P, m³/P, gal/P, kgal/P, Cuft/P, bbl/P, Impgal/P, kImpgal/P, I(N)/P, m³(N)/P, SI/P, Scuft/P, Sm³/P NOTE To select the pulse output mass or volume has to be selected. If mass flow or volume flow is selected the output delivers only frequency. If Pulse 1 select is Mass flow, Volume flow, Density, Temperature or Concentration meas, only Hz can be selected. If Pulse 1 select is F-Total mass, R-Total mass, F-Total volume, R-Total volume, F-Total net or R-Total net only unit/P can be selected. I(N)/P, m³(N)/P only for gas application. SI/P, Scuft/P, Sm³/P only for gas application or if reference density value is selected. Pulse 1 rate The Pulse rate can be set according to the unit set in Pulse 1 unit. Pulse rate is 0 to 10000 Hz. Minimum output 20 Hz. Pulse 1 active mode Select: On Active, Off Active The output levels depending on this parameter are shown on page 7-91. Pulse 1 width Select: 0.05ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms Pulse 1 at alarm Select: 0P/0Hz, Measured value, Hold If 0P/0Hz is selected, in case of alarm the pulse output is stopped. If Measured value is selected, the pulse output keeps on measuring. If Hold is selected, the pulse output keeps the value before entering the alarm/error state. IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-90 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION SO 1 function Select: No Function, Flow direction, Total limit switch, Mass flow alm 1, Mass flow alm 2, Mass flow alm 1+2, Vol flow alm 1, Vol flow alm 2, Vol flow alm 1+2, Density alm 1,Density alm 2, Density alm 1+2, Temp alm 1, Temp alm 2, Temp alm 1+2, Concentration meas alm 1, Concentration meas alm 2, Concentration meas alm 1+2, Net flow alm 1, Net flow alm 2, Net flow alm 1+2, Slug alarm, Empty alarm, Corrosion alarm, All alarms, All errors, All alarms & errors If Flow direction is selected, status output becomes active for forward flow and not active for reverse flow, if parameter flow direction set to forward. It is the other way round, if parameter flow direction is set to reverse (see 3.17). If Total limit switch is selected, status output becomes active, when the totalizer reaches the value set to parameter Total limit switch (see 3.17). If an alarm function is selected, status output becomes active, if the concerning alarm occurs. If All alarms is selected, status output becomes active, if at least one alarm occurs. The same applies for errors with the setting All errors. For All alarms & errors the status output becomes active, if at least one alarm or one error occurs. SO1 active mode Select: On Active, Off Active The output levels depending on this parameter are shown on page 7-94. If Pulse is selected, under Basis Setup the Pulse unit and Pulse rate have to be defined. Under ´Detailed Setup´ Pulse unit Pulse rate Pulse active mode and Pulse width have to be defined. If the pulse output is set under Basic Setup, the pulse width is the width set under Detailed Setup If the pulse width is not configured under Detailed Setup menu the pulse width will be set default to 1ms. If ´frequency´ is selected the frequency generated at URV (upper range value) has to be defined. Default is URV = 1000Hz. Differences between Pulse and Frequency output For pulse output the mass (or volume) is internally totalized and if the increment is reached, one pulse is sent. For a frequency output the measured value is calculated in actual frequency according to the definition of the user (e.g. 10000 Hz = 54321 kg/h) with 50% duty cycle. Set as frequency output the pulse length is changing with the change of the measured value. How to set status, pulse or frequency output (using the display keys, equivalent via HART) Status Basic Setup or Detailed Setup Pulse/Status out 1 Pulse/Stat 1 select Select : Status out Pulse or Frequency Basic Setup or Detailed Setup Pulse/Status out 1 Pulse/Stat 1 select Select : Pulse Pulse 1 select F-Total mass → Pulse R-Total mass → Pulse F-Total volume → Pulse R-Total volume → Pulse F-Total net → Pulse R-Total net → Pulse Mass Flow → Frequency Volume Flow → Frequency Net Flow → Frequency Density → Frequency Temperature → Frequency Concentration meas.→ Frequency Notice : By selecting a variable (mass or volume) which can be totalized automatically the pulse output is selected. All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-91 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION If the flow is higher than max.Q pulses will be lost. Therefore it is mandatory to choose the pulse width/rate so, that the calculated max.Q is always 10% higher than the maximum expected flowrate. NOTE At frequencies above 500 Hz, frequency output 1 inserts gaps in the pulse train. Therefore it is required to use a minimum pulse integration time of 10 sec. to get accurate frequency measurements. If shorter pulse integration time is necessary e.g. for batching applications, it is recommended to use frequency output 1 up to max. 500 Hz. 10% higher is recommended because the duty cycle is not always exact 50%. For certain pulse widths the duty cycle at max.Q is larger than 50% so fewer pulses can be generated. These pulses are delivered later when the flowrate is again below max.Q minus 10%. To avoid this situation it is recommended to keep the flowrate always 10% below max.Q. Example : Flowrate : 11 t/h Pulse unit : kg Pulse rate : 0.1 kg/P Time factor (related to s) = 3600 P/h Check : Lowest pulse width = 0.5 s*pulse rate* time factor/ max. flow rate = 0.5 s*0.1 kg/P *3600 P/h /(11000 kg/h) = 16.4 ms → customer should select 10 ms pulse width or lower. Max. Q = 18000 kg/h 11000 kg/h < 18000 kg/h - 10% Result : Pulse width = 10 ms Pulse rate = 0.1 kg/P For a first orientation the max. Q for certain pulse widths and units for a pulse rate of 0.1, 1 and 10 are given in the table 7-1. Set as a pulse output the pulse length is constant but the time between the pulses varies. Even at constant flow the time between the pulses might vary because the microprocessor has to find a suitable gap in its timing to send the pulse. Typical pattern for frequency output : Typical pattern for pulse output (50 ms; 0.1 kg/P; 2580 kg/h) : Max. flow restriction : flow Setting the pulse output Because the duty cycle of pulses is max. 50%, the max. flowrate is restricted by the pulse width, the unit and the pulse rate : Max. flow rate = 1s/(pulse width*2) *pulse rate *time factor Example : Max. Q should be calculated in kg/min Pulse width = 50 ms Pulse rate = 0.1 kg/P Time factor (related to s) = 60 P/min Max. Q = 1s/(0.05s *2) *0.1kg/P * 60P/min = 60kg/min IM 01R04B07-00E-E 3rd edition July 01, 2013-00 this amount will be lost Max flow from pulse width, unit, rate Grey zone t 3-92 F3.EPS All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION Table 7-1: Max. flowrate for different pulse settings reduced by 10%: Pulse Unit g g g kg kg kg t t t Pulse rate 0.1 1 10 0.1 1 10 0.1 1 10 1000 500 0.45 0.9 Pulse Width in ms 100 50 10 5 1 0.5 0.1 ** Max. pulse sending frequency for the different pulse settings in P/s 4.5 9 45 90 450 900 4500 0.05 ** 9000 Maximum Flow Rate * 162 g/h 1.62 kg/h 16.2 kg/h 162 kg/h 1.62 t/h 16.2 t/h 162 t/h 1620 t/h 16200 t/h 324 g/h 3.24 kg/h 32.4 kg/h 324 kg/h 3.24 t/h 32.4 t/h 324 t/h 3240 t/h --- 1.62 kg/h 16.2 kg/h 162 kg/h 1.62 t/h 16.2 t/h 162 t/h 1620 t/h 16200 t/h --- 3.24 kg/h 32.4 kg/h 324 kg/h 3.24 t/h 32.4 t/h 324 t/h 3240 t/h ----- 16.2 kg/h 32.4 kg/h 162 kg/h 324 kg/h 1.62 t/h 3.24 t/h 162 kg/h 324 kg/h 1.62 t/h 3.24 t/h 16.2 t/h 32.4 t/h 1.62 t/h 3.24 t/h 16.2 t/h 32.4 t/h 162 t/h 324 t/h 16.2 t/h 32.4 t/h 162 t/h 324 t/h 1620 t/h 3240 t/h 162 t/h 324 t/h 1620 t/h 3240 t/h 16200 t/h --1620 t/h 3240 t/h 16200 t/h ------16200 t/h ----------------------------------- *) Maximum Flow rate is also limited by sensor size ** Note for pulse output 2: Pulse width 0.1 ms & 0.05 ms are only implemented for convenience. Due to the limited bandwidth proper function can not be guaranteed. The following tables show the physical output levels of the pulse / status outputs depending on the setting of parameter Pulse 1/2 active mode or SO 1/2 active mode. Output Situation On active Output transistor Pulse/Status out 1 No Alarm/No Pulse Alarm/Pulse open (OFF) closed (ON) Level Pout+ Passive High (Us)* Low (≤ 1 V) Pulse/Status out 2 No Alarm/No Pulse Alarm/Pulse open (OFF) closed (ON) Level Sout+ High (Us)* Low (≤ 1 V) Output Situation Off active Output transistor Pulse/Status out 1 No Alarm/No Pulse Alarm/Pulse closed (ON) open (OFF) Level Pout+ Passive Low (≤ 1 V) High (Us)* Pulse/Status out 2 No Alarm/No Pulse Alarm/Pulse closed (ON) open (OFF) Level Sout+ Low (≤ 1 V) High (Us)* Level Pout+ Active (/AP) High (15 VDC) Low (≤ 1 V) Level Pout+ Active (/AP) Low (≤ 1 V) High (15 VDC) *) Us is the external power supply voltage of the pulse / status output All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-93 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.12 Pulse/Status output 2 functions (Basic or Detailed Setup) Pulse/Status out 2 To set the pulse/status output 2. Pulse/Stat 2 select Select: Pulse out, Status out, No function If Pulse is selected, Status out 2 (SO) is not available. If Status out is selected, pulse parameters are not available. Pulse 2 select Select: Mass flow (0), Volume flow (1), Density (2), Temperature (3), Concentration meas (4), Net flow (5), None (6), F-Total mass (7), R-Total mass (8), F-Total volume (9), R-Total volume (10), F-Total net (11), R-Total net (12) Numbers may be displayed if selected via HART. If F-Total mass, F-Total volume or F-Total net are selected, pulse output only works at forward flow. If R-Total mass, R-Total volume or R-Total net are selected, pulse output only works at reverse flow. Pulse 2 unit Select: Hz, g/P, kg/P, t/P, lb/P, cm³/P, l/P, m³/P, gal/P, kgal/P, Cuft/P, bbl/P, Impgal/P, kImpgal/P, I(N)/P, m³(N)/P, SI/P, Scuft/P, Sm³/P NOTE If Pulse 2 select is Mass flow, Volume flow, Density, Temperature or Concentration meas, only Hz can be selected. To select the pulse output mass or volume has to be selected. If mass flow or volume flow is selected the output delivers only frequency. If Pulse 2 select is F-Total mass, R-Total mass, F-Total volume, R-Total volume, F-Total net or R-Total net only unit/P can be selected. I(N)/P, m³(N)/P only for gas application. SI/P, Scuft/P, Sm³/P only for gas application or if Reference density value is selected. Pulse 2 rate The Pulse rate can be set according to the unit set in Pulse 2 unit. Pulse rate is 0 to 2000 Hz. Minimum output 20 Hz. Pulse 2 active mode Select: On Active, Off Active The output levels depending on this parameter are shown on page 7-91. Pulse 2 width Select: 0.05ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms Pulse 2 at alarm Select: 0P/0Hz, Measured value, Hold If 0P/0Hz is selected, in case of alarm the pulse output is stopped. If Measured value is selected, the pulse output keeps on measuring. If Hold is selected, the pulse output keeps the value before entering the alarm/error state. IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-94 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION SO 2 function Select: No Function, Flow direction, Total limit switch, Mass flow alm 1, Mass flow alm 2, Mass flow alm 1+2, Vol flow alm 1, Vol flow alm 2, Vol flow alm 1+2, Density alm 1,Density alm 2, Density alm 1+2, Temp alm 1, Temp alm 2, Temp alm 1+2, Concentration meas alm 1, Concentration meas alm 2, Concentration meas alm 1+2, Net flow alm 1, Net flow alm 2, Net flow alm 1+2, Slug alarm, Empty alarm, Corrosion alarm, All alarms, All errors, All alarms & errors If Flow direction is selected, status output becomes active for forward flow and not active for reverse flow, if parameter flow direction set to forward. It is the other way round, if parameter flow direction is set to reverse (see 3.17). If Total limit switch is selected, status output becomes active, when the totalizer reaches the value set to parameter Total limit switch (see 3.17). If an alarm function is selected, status output becomes active, if the concerning alarm occurs. If All alarms is selected, status output becomes active, if at least one alarm occurs. The same applies for errors with the setting All errors. For All alarms & errors the status output becomes active, if at least one alarm or one error occurs. SO2 active mode Select: On Active, Off Active The output levels depending on this parameter are shown on page 7-94. Detailed information about using the pulse and status output see chapter 3.12. 3.13 Status input functions (Basic or Detailed Setup) Status input To set the status input. SI function Select: No function, Autozero, Reset flex totals, Reset mass totals, Reset volume totals, Reset net totals, Reset all totals, 0% signal lock If Autozero is selected, active status input starts autozero procedure. If 0% signal lock is selected, analog outputs 1 and 2 are fixed to 4 mA while status input is active. If parameter Total reset cntrl is enabled: -If Reset flex totals is selected, active status input sets flex totalizer to zero. -If Reset mass totals is selected, active status input sets mass totalizer to zero. -If Reset volume totals is selected, active status input sets volume totalizer to zero. -If Reset net totals is selected, active status input sets net totalizer to zero. -If Reset all totals is selected, active status input sets all totalizer to zero. SI active mode Select: On Active, Off Active If On Active is selected, the status input is closed active. If Off Active is selected, the status input is open active. All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-95 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.14 HART output (Detailed Setup) HART output To set the assignments of HART device variables which are reported via HART Universal Command 3. PV is Set the assignment of Primary variable (PV). PV is linked to Analog output 1. Changing of PV will change the assignment of Analog output 1 and vice versa. Select: Mass flow, Volume flow, Density, Temperature, Concentration meas, Net flow, None SV is Set the assignment of Secondary variable (SV). SV is linked to Analog output 2. Changing of SV will change the assignment of Analog output 2 and vice versa. Select: Mass flow, Volume flow, Density, Temperature, Concentration meas, Net flow, None If Analog output 2 is not available (option /KF2) an extended selection is available, see “HART Variable list” below. TV is Set the assignment of Tertiary variable (TV). TV is linked to Pulse output 1 if Pulse/Stat 1 sel is set to Pulse. In this case changing of TV will change the assignment of Pulse output 1 and vice versa. Select: Mass flow, Volume flow, Density, Temperature, Concentration meas, Net flow, None, F-Total mass, R-Total mass, F-Total volume, R-Total volume, F-Total net, R-Total net If Pulse/Stat 1 sel is set to Status out or No function an extended selection is available, see “HART Variable list” below . This selection is stored separately from the selection for “Pulse”. QV is Set the assignment of Quaternary variable (QV). QV is linked to Pulse output 2 if Pulse/Stat 2 sel is set to Pulse. In this case changing of QV will change the assignment of Pulse output 2 and vice versa. Select: Mass flow, Volume flow, Density, Temperature, Concentration meas, Net flow, None, F-Total mass, R-Total mass, F-Total volume, R-Total volume, F-Total net, R-Total net If Pulse output 2 is not available (option /KF2 ) or Pulse/Stat 2 sel is set to Status out or No function an extended selection is available, see “HART Variable list” below. This selection is stored separately from the selection for “Pulse”. HART Variable list (For HART- communication: Variables which are not allowed will be rejected by "Invalid Selection") IM 01R04B07-00E-E Mass flow, Volume flow, Density, Temperature, Concentration meas, Net flow, None, F-Total mass, R-Total mass, F-Total volume, R-Total volume, F-Total net, R-Total net, F-Total flex, R-Total flex, D-Total mass, D-Total volume, D-Total net, D-Total flex, F-Total energy, Velocity, Drive Gain 3rd edition July 01, 2013-00 3-96 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION 3.15 Totalizer functions (Basic or Detailed Setup) Totalizer Total flex select Total flex unit Total mass unit Total volume unit Total net unit To set totalizer function. Totalizer increments the forward flow if flow direction is forward or the reverse flow if flow direction is reverse. Flex totalizer is available as a secondary total for mass, volume or net. Select: Mass, Volume, Net If assignment is changed Flex totalizer will be set to zero, Total flex unit will be set to default. When Total flex select is set to Mass or Net, the Total flex unit g, kg, t, lb can be selected. When Total flex select is set to Volume or Net, the Total flex unit cm³, l, m³, gal, kgal, Cuft, bbl, Impgal, kImpgal, l(N), m³(N), Sl, Scuft, MMscuft, Sm³ can be selected. l(N), m³(N) only for gas application. Sl, Scuft, MMscuft, Sm³ only for gas application or if Reference density value is selected. Select: g, kg, t, lb For Total volume unit cm³, l, m³, gal, kgal, Cuft, bbl, Impgal, kImpgal, l(N), m³(N), Sl, Scuft, MMscuft, Sm³ can be selected. l(N), m³(N) only for gas application. Sl, Scuft, MMscuft, Sm³ only for gas application or if Reference density value is selected. For option /CST: When Net flow select is set to Mass, the Total net unit g, kg, t, lb can be selected. When Net flow select is set to Volume, the Total net unit cm³, l, m³, gal, kgal, Cuft, bbl, Impgal, kImpgal can be selected. Total energy unit Energy factor/Heat of combustion Total switch select Total limit switch Total at alarm Total reset cntrl All Rights Reserved. Copyright © 2009, Rota Yokogawa For option /Cxx: Selection depends from concentration unit. Select: MJ, Btu Set the calorific value of the medium with the unit Energy factor/ Heat of combust. unit. The totalized energy of the medium can be indicated on display by F-Total energy. Heat of combust. unit MJ/kg, Btu/lb, MJ/m³(N) and Btu/Scuft can be selected. Select: Flex Total, Mass Total, Volume Total, Net Total A totalizer limit can be set only to the forward totalizer selected in Total select. If status output is set to Total switch, status output is set active, if the totalizer reaches this value. Total switch is not active if set to 0.0. Select: Hold, Continue Total Characteristic of totalizer selected in Total select in case of the Total switch is active. If Hold is selected forward and reverse totalising stops. Select: Inhibit, Enable Enables or inhibits total reset. 3-97 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION Total reset Select: Not Execute, Reset flex totals, Reset mass totals, Reset volume totals, Reset net totals, Reset all totals After execution of reset totals, forward and reverse total of the selected totalizer will be set to zero. If the total value 9999999 is reached, the indication changes to exponential type. During exponential indication the resolution is lower. If full accuracy is needed, total reset must be executed to reach precise indication. 3.16 Flow direction function (Detailed Setup) Flow direction Select: Forward, Reverse See 3.12 and 3.13 according influence on status output (SO 1/2 function = Flow direction) If Reverse is selected, the flow direction in the other direction of the arrow on the detector is used as positive values of flow. IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-98 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION 3.17 Concentration measurement (Detailed Setup) Concentration meas (only for option/CST or /Cxx) To set the functions of concentration measurement. For xx=00 to 99 a customer specific or defined table is stored in the converter in factory. For /CST temperature coefficients have to be determined by the customer. Concentration meas unit (only available for option/CST) Select: °Brix, Wt-% sol, Vol% sol, Wt-%, Vol% Concentration meas format Select: xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX Concentration meas LRV (low range value) Set a concentration value to the 4 mA or 0 Hz Concentration meas (upper range value) Set a concentration value to the 20 mA or xxxxx = Hz. Abs(URV-LRV) ≥ 10% Concentration meas damping Set the damping time in s. Damping time affects outputs and display. After 5 times damping time the given value is displayed (t=63%). Concentration meas lowcut Set the low cut. Low cut affects outputs and display. Concentration meas alm 1 sel Select: No function, More than, Less than Concentration meas alm 1 crit Select a concentration alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13). Concentration meas alm 2 sel Select: No function, More than, Less than Concentration meas alm 2 crit Select a concentration alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13). Restrictions: All alarms have to be in 0-110% of URV-LRV Alarm criteria 2 must always be larger than alarm criteria 1. Concentration meas setup (only for option /CST) To setup the coefficients used for calculation of concentration using the Standard Concentration Measurement. Reference temperature Set the temperature where the reference density of both components of the mixture has been determined. Ref. density carrier Set the density of the carrier liquid determined at the reference temperature. Temp. coeff. a carrier Set the linear temperature coefficient of the density of the carrier liquid. Temp. coeff. b carrier Set the squared temperature coefficient of the density of the carrier liquid. Ref. density product Set the density of the product determined at the reference temperature. Temp. coeff. a product Set the linear temperature coefficient of the density of the product. Temp. coeff. b product Set the squared temperature coefficient of the density of the product. For more information on concentration measurement see TI "Concentration Measurement" TI 01R04B04-04E-E. All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-99 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.18 Net flow (Detailed Setup) Net flow To set the functions of net flow measurement. Net flow is only available if concentration measurement is activated (option /Cxx or /CST). The actual flow is multiplied with the concentration). Net flow select (only available for option /CST) Select: Mass, Volume Net flow unit When Net flow select is set to Mass: g/s, g/min, g/h, kg/s, kg/min, kg/h, kg/d, t/min, t/h, t/d, lb/s, lb/min, lb/h, lb/d can be selected When Net flow select is set to Volume: cm³/s, cm³/min, cm³/h, l/s, l/min, l/h, l/d, m³/s, m³/min, m³/h, m³/d, gal/s, gal/min, gal/h, gal/d, Cuft/s, Cuft/min, Cuft/h, Cuft/d, bbl/s, bbl/min, bbl/h, bbl/d, Impgal/s, Impgal/min, Impgal/h, Impgal/d can be selected Net flow format Select: xxxxxxx, xxxxx.X, xxxx.XX, xxx.XXX, xx.XXXX, x.XXXXX Net flow LRV (low range value) Set a net flow value to the 4 mA or 0 Hz. Net flow URV (upper range value) Set a net flow value to the 20 mA or xxxxx = Hz. Abs(URV-LRV) ≥ 5% of Qnom. Net flow damping Set the damping time in s. Damping time effects outputs and display. After 5 times damping time the given value is displayed (t=63%). Net flow lowcut Set the low cut effects output and display. A hysteresis of 0.05% of Qnom is given by the system. Net flow alm 1 sel Select: No function, More than, Less than Net flow alm 1 crit Select a net flow alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13) Net flow alm 2 sel Select: No function, More than, Less than Net flow alm 2 crit Select a net flow alarm level. What happens in case of an alarm has to be defined in Status out (3.12, 3.13) Restrictions: All alarms have to be in 0-110% of URV-LRV Alarm criteria 2 must always be larger than alarm criteria 1. IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3-100 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION 3.19 Slug detection (Detailed Setup) Slug detection Detection of bubble flow. Not available if gas measurement After slug criteria has been reached, slug is supervised during slug is ordered. duration. If slug is still detected after slug duration has expired, the selected action in After slug is taken. See below table. Slug alarm select Select: Not apply, Apply Drive gain To read drive gain. To set a suitable slug criteria the customer must know the drive gain level of normal flow condition and of slug flow condition. This function is suitable to evaluate this level. Slug criteria Above this drive gain level slug flow is assumed. Slug duration Duration time is designed to ignore short gas bubbles. Only after Slug duration has expired the setting in After slug will be taken in account. In normal slug application set slug duration to zero. After slug Select: Measured value, Hold If Hold is selected mass flow and density keep their value before occurrence of the slug alarm and as long as slug alarm is detected. Drive gain damping Set drive gain damping time to get a constant drive gain level. Gas application? Yes No Slug alarm select = Apply? Yes No Drive gain > Slug criteria? Yes No Duration active? Slug detection off Yes After duration Function active Alarm off Measurement continued Slug detection On Alarm on Measurement continued or value hold Slug detection off Slug detection off Alarm off Influence of slug on mass flow, density and drive gain : mass flow, if Hold mass flow, if Measured value duration time mass flow density drive gain single bubble All Rights Reserved. Copyright © 2009, Rota Yokogawa slug flow time T88.EPS 3-101 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.20 Empty pipe detection (Detailed Setup) Empty pipe detection Detection of empty pipe Not available if gas measurement (option /GA) is ordered. Not working if fixed reference density is enabled. After Empty pipe crit has been reached, alarm output is activated if selected. This function can also be used to detect tube failure (see chapter 8.8). Empty pipe alm sel Select: Not apply, Apply Empty pipe crit Set density value as criteria when empty pipe alarm should happen. If Empty pipe crit is smaller than Density URV (or LRV, whichever is higher), alarm appears if density is lower than Empty pipe crit. If Empty pipe crit is equal or greater than Density URV (or LRV, whichever is higher), alarm appears if density is higher than Empty pipe crit. After empty pipe Select the behaviour of the outputs after empty pipe has happened. Select: Massflow = Zero, Measured Value, Hold With this function the outputs can be set to zero if the detector runs empty during maintenance. It is also useful for batching if the batch starts with an empty pipe. In such case please install the detector vertically. Gas application? Yes No Empty pipe alm sel = Apply? Yes Empty pipe crit < Density URV? (or LRV, whichever is higher) Empty pipe OFF No Empty pipe crit ≥ Density URV? (or LRV, whichever is higher) Yes No Yes No Empty pipe ON Empty pipe OFF Empty pipe ON Empty pipe OFF Empty pipe OFF Alarm On if density < empty pipe crit Alarm off Alarm On if density ≥ empty pipe crit Alarm off Alarm off Alarm off Outputs either Measured Value, Hold or 4mA/0Hz IM 01R04B07-00E-E 3rd edition July 01, 2013-00 Outputs either Measured Value, Hold or 4mA/0Hz 3-102 All Rights Reserved. Copyright © 2009, Rota Yokogawa 3. PARAMETER DESCRIPTION 3.21 Corrosion detection (Detailed Setup) Corrosion detection Detection of corrosion in pipe. Not available if gas measurement is ordered. Not working if fixed reference density is enabled. This function is useful if the max. density of the fluid is known and corrosion may happen. As alternative to this function the user can watch density periodically. After density value stored in Corrosion crit has been reached, alarm output is activated if selected. Corrosion alm sel Select: Not apply, Apply Corrosion crit Set density value up to Density URV or Density LRV (whichever is higher) Corrosion damp Set damping on density for comparison with Corrosion crit, up to 10h. This function is only good for liquids with relative constant density. Set an upper density level. If this density level is reached permanently, a warning occurs. 3.22 Detector data (Detailed Setup) The sensor model is defined in Parameter Detailed Setup / Sensor model : WARNING The function Sensor model is only for changing a converter in case of maintenance. Never change the sensor model if the sensor is not changed. The sensor constants for the selected detector are stored in parameters Detailed Setup / Sensor constants. You find the main sensor constants on the name plate. In case of doubt of the measured value please confirm that the proper sensor constants are stored. The serial number of the converter is stored in ´Detailed Setup / Device Information / Serial no. Converter´. The serial number of the detector is stored in ´Detailed Setup / Device Information / Serial no. Detector´. For compact version RCCT3 there is only one serial number. The tag number, if provided by the customer (option /BG), is stored in Basic setup / Tag. For integral type RCCT3x and remote type RCCF31 / RCCR31 combined ordered with RCCS3x the detector data are factory stored in the concerning parameters. For not combined remote type RCCF31 with option /NC see chapter 5.5. If the parameter Detailed setup / Sensor model is changed to another type, the following parameters are changed to new default values corresponding to the selected model : Qnom, Mass flow unit, Mass flow LRV, Mass flow URV, Vol flow unit, Vol flow LRV, Vol flow URV, Autozero range, Autozero fluctuation range and the sensor constants. In this case the sensor constants, the detector serial number and, if available, the tag number must be set to the values corresponding to the used detector as described above. All Rights Reserved. Copyright © 2009, Rota Yokogawa 3-103 IM 01R04B07-00E-E 3rd edition July 01, 2013-00 3. PARAMETER DESCRIPTION 3.23 Reading maximum fluid temperature (Detailed Setup) Fluid max. temp IM 01R04B07-00E-E 3rd edition July 01, 2013-00 The highest measured medium temperature ever reached can be read in this parameter. This parameter can not be reset or changed by the user. 3-104 All Rights Reserved. Copyright © 2009, Rota Yokogawa All Rights Reserved. Copyright © 2009, Rota Yokogawa IM 01R04B07-00E-E 3rd edition July 01, 2013-00 YOKOGAWA ELECTRIC CORPORATION World Headquarters 9-32, Nakacho 2-chome, Musashino-shi Tokyo 180-8750 Japan www.yokogawa.com YOKOGAWA ELECTRIC ASIA Pte. LTD. 5 Bedok South Road Singapore 469270 Singapore www.yokogawa.com/sg YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan GA 30265 USA www.yokogawa.com/us YOKOGAWA CHINA CO. LTD. 3F Tower D Cartelo Crocodile Building No.568 West Tianshan Road Changing District Shanghai, China www.yokogawa.com/cn Euroweg 2 3825 HD AMERSFOORT The Netherlands www.yokogawa.com/eu YOKOGAWA MIDDLE EAST B.S.C.(c) P.O. Box 10070, Manama Building 577, Road 2516, Busaiteen 225 Muharraq, Bahrain www.yokogawa.com/bh IM 01R04B07-00E-E 3rd edition July 01, 2013-00 Yokogawa has an extensive sales and distribution network. Please refer to the European website (www.yokogawa.com/eu) to contact your nearest representative. All Rights Reserved. Copyright © 2009, Rota Yokogawa Subject to change without notice